3000W 24V PowMr Solar Inverter Installation Video - POW LVM3K 24V H

  Рет қаралды 9,281

Solar System

Solar System

Жыл бұрын

POW LVM3K 24V-H is an upgraded version of the original model POW LVM3K 24V.
Amazon Link:www.amazon.com/dp/B08R3MSXTG
3000W Pure sine Wave Inverter
24V DC to 120V /110V AC, built-in 80A Mppt charge controller
Max.PV input: 4000W, 13A, 450V
Starting voltage 150V
Fit for Lead-Acid(seal, AGM, Gel, Flooded) and Lithium battery.
Support Utility/Generator/Solar Charge
4 Charging Mode +3 Load Working Mode
Battery Four Charging Mode:
CSO: Source Priority: Solar
CUB: Source Priority: Utility
SNU (Default): Solar energy and utility will charge the battery at the same time;
OSO: Solar energy will be the only charging source even if utility is available.
Three-Load Working Mode:
SOL: Priority: Solar---Battery---Utility;
UTI (Default): Priority: Utility---Solar---Battery;
SBU: Battery power load first, then Utility

Пікірлер: 60
@woobensbienaime9766
@woobensbienaime9766 Жыл бұрын
Well done and I love it You are so clever
@temank2741
@temank2741 Жыл бұрын
1. The grounding of 3000W24V AC output shares the same grounding port as the AC input terminal 2. The grounding screw on the shell of the solar inverter is connected to the ground with a wire
@architectrobo5772
@architectrobo5772 Ай бұрын
Thank you so much, a very professional guide 👍
@temank2741
@temank2741 Ай бұрын
Thanks
@deumerguy
@deumerguy 11 ай бұрын
Hello, One Question please: In europe, Mono 220 volts only , Hybrid converter for 48 volts batteries; What is the "empty consumption" (at night without much load f.i.) of your 6200 or 8200 or 10.200 watt machines? Thanks
@temank2741
@temank2741 11 ай бұрын
No Load Power Consumption: 50W(6200), 70W(8200), 72W(10200)
@Yankee802
@Yankee802 9 ай бұрын
I'm installing in a van, the A/C out uses only 2 wires, is the 3rd wire (ground) not used?
@temank2741
@temank2741 9 ай бұрын
The third grounding wire of the AC output can be connected to the grounding wire terminal of the AC input
@dontforget2020
@dontforget2020 6 ай бұрын
The installation booklet on my new model no. HF2430U60 says "for PV to charge 24v battery banks, you will need a minimum PV VOC of 120VDC". How do I calculate that? I have four, 100W 24volt panels that I will be running in series. Will that be enough?
@temank2741
@temank2741 6 ай бұрын
The HF2430U60 model has a maximum input PV voltage of 100 V. We suggest you to check the label on the inverter case to see if the Max.PV Open Voltage is 100 V or 450 V. If it's 100 V, the startup voltage needs to be more than 30V. If it's 450 V, the first startup voltage needs to be more than 150V, and the subsequent voltages can start up as long as they have 120V. Then check what the open circuit voltage of your solar panel is. Assuming it is 32V, 32V*4=128V, which is not enough to start for the wide voltage version of the inverter, you need to increase the solar panel. But for the low-voltage version of the inverter, just 30V is enough to start. You consider 4 solar panels in parallel. Or 2 series 2 parallel.
@mikemcdonald5147
@mikemcdonald5147 9 ай бұрын
can I use the inverter without the ac in? I want to be off grid and only have solar in. I hope that makes sense.
@temank2741
@temank2741 8 ай бұрын
Yes, you can use the inverter without the AC in Note: The initial start-up voltage of the PV of this inverter needs to be greater than 150V Afterwards, the voltage just greater than 120V can the inverter be started.
@runneryg
@runneryg Жыл бұрын
where do you connect the ground from the investor to where? you did not show this.
@sugarpuffextrem
@sugarpuffextrem Жыл бұрын
The ground chassi plug would go to an literal earth ground rod.
@someoneyoudontknow8020
@someoneyoudontknow8020 11 ай бұрын
for clarification, in the manual of same item, the recommended wire size is 6AWG.. i am confuse because you are using 2AWG in this presentation. thanks.
@temank2741
@temank2741 11 ай бұрын
Hi friend, battery wire diameter recommended: 30mm ²/ 2AWG; The recommended PV Wire Diameter is 3.5mm ²/ 12AWG The recommended AC input/output wire diameter is 6mm ²/ 10AWG The wire diameter is only for reference In case of long-distance between a photovoltaic array and an all-in-one inverter or between an all-in-one inverter and battery, using thick wire to reduce voltage drop and improve system performance
@gazmadyaker8413
@gazmadyaker8413 8 ай бұрын
Why Would I need 2 x40 amp Breakers ? Here in the UK our plugs have a 13 amp fuse built in so this would blow first. (ac in ) Also I have wired an extension lead to the AC out which also has a 13 amp Fuse as standard which again would blow, so the 40 amp breakers would not be needed as they would never blow because the 13 amp fuse would always blow first. I agree using a160 amp battery breaker but not sure about the other 2
@temank2741
@temank2741 8 ай бұрын
If the maximum output current provided to the load through bypass is 40A, it cannot exceed this value. Therefore, it is recommended to configure a standard 2P-40A-AC circuit breaker. The 13A fuse is too small and can easily trigger the fuse
@jegi8202
@jegi8202 2 ай бұрын
What is the idle current of the 24V-H model? Is it still around 70 watts like the 24V ?
@temank2741
@temank2741 Ай бұрын
Yes
@franknickel2604
@franknickel2604 9 ай бұрын
Can I use the inverter without the AC Out comection? Thank you
@temank2741
@temank2741 9 ай бұрын
Yes
@felixdammy3791
@felixdammy3791 11 ай бұрын
Can the system work without a solar panel, just with grild alone?
@temank2741
@temank2741 10 ай бұрын
Yes, you can use the Utility or AC generator for charging. It can also be used only as an inverter
@YakubHasan
@YakubHasan 5 ай бұрын
How can I set 24v battery to set 40% use first at night then keep rest for emergency backup. Thanks. My model is Hvm3.2H- 24v. Do I have to set low cut and high cut?
@temank2741
@temank2741 5 ай бұрын
Yes, you need to set the low-voltage disconnection voltage of the battery to stop supplying power to the load(负荷). For example, if it defaults to 21.2V, you can set it to 24V.
@fpmd99
@fpmd99 9 ай бұрын
Where does chassis grounding go?
@temank2741
@temank2741 9 ай бұрын
I‘m so sorry, I didn't understand your question well
@EdwardGrubb-iz3nt
@EdwardGrubb-iz3nt 24 күн бұрын
What do the left and right bars on the front screen mean I cannot find it in the book
@temank2741
@temank2741 2 сағат бұрын
Sorry, I didn't understand your question. Can you contact me through email:ysolar@foxmail.com ? It would be best if you could provide photos, thank you!
@blindvegan
@blindvegan 7 ай бұрын
I have the POW-LVM3K-24V-H, there's only two spots for AC output no ground, am I supposed to ground it to the inverters chassis? Should I add it to the grounding screw that's there for grounding because you cannot run AC safely without a proper ground.
@temank2741
@temank2741 7 ай бұрын
Hi friend, the grounding of the AC output and the grounding of the AC input share the same terminal (the grounding terminal of the AC input).
@blindvegan
@blindvegan 7 ай бұрын
@@temank2741 the input side of the AC that would come from the house is not being used this unit is being used off grid
@temank2741
@temank2741 7 ай бұрын
Is the charging mode you have chosen priority for mains power?@@blindvegan
@blindvegan
@blindvegan 7 ай бұрын
⁠@@temank2741there is NO mains power
@temank2741
@temank2741 7 ай бұрын
You can directly connect the AC output grounding wire to the grounding screw on the housing, and then make the housing grounding@@blindvegan
@nikossof
@nikossof Жыл бұрын
what are the minimum volts for the inverter to work without batteries? Thanks 😊
@temank2741
@temank2741 11 ай бұрын
Sorry, this inverter needs to be connected to a battery for operation. No support for battery-free loading
@kllcenly869
@kllcenly869 3 ай бұрын
Does this means inverter cannot work with only solar panels ??
@rontech34
@rontech34 11 ай бұрын
Where do I get the 160 breaker
@temank2741
@temank2741 11 ай бұрын
Search for "DC circuit breaker 2p 160a" on shopping websites, such as Amazon or eBay
@user-xw8rw2mo8q
@user-xw8rw2mo8q Жыл бұрын
How would be the connection in mexico with 2 lines 110v ??
@temank2741
@temank2741 Жыл бұрын
Only use one 110V live wire with one neutral wire. It is single-phase 110V AC power. If two 110V live wires with different phases are connected, it means inputting two-phase 220V AC power. This inverter cannot be connected to such a high-voltage AC input.
@temank2741
@temank2741 Жыл бұрын
If there is only two-phase 220V, no single-phase 110V, or no zero line, it cannot be used. Suggest purchasing 2 sets of PowMr split-phase 5000W solar inverters or a single PowMr 10K split-phase solar inverter
@obiageliodi8734
@obiageliodi8734 11 ай бұрын
I want to buy the 3200w, 220v Can I use any type of battery and is there a specific size that I must use?
@temank2741
@temank2741 9 ай бұрын
The voltage of the battery should be consistent with the system voltage of the inverter. For example, a 24V inverter should connect to a 24V battery. And suggested battery capacity greater than 100AH
@ledsigns7236
@ledsigns7236 5 ай бұрын
what will happen if i only use 100 ah
@elioramirez8339
@elioramirez8339 Жыл бұрын
hi uo to how many solar panel can i put for 24v
@temank2741
@temank2741 Жыл бұрын
Is the purchase the latest version of POW-LVM3K-24V-H? The maximum input of this inverter is: 4000W, 450V, 13A The total Power must not exceed the PV power when the PV modules are connected in series or parallel-PV power: 4000W The total voltage must not exceed the PV open circuit voltage when the PV modules are connected in series or parallel-PV open circuit voltage 430V at 25℃ environment temperature. The total short-circuit current must not exceed the PV short-circuit current when the PV modules are connected in series or parallel-PV short-circuit current:13A All three conditions need to be met simultaneously For example, your solar panel is 300W, 28V, 10A Due to a current of 10A, all solar panels can only be connected in series and cannot be connected in parallel 450/28=16.07, rounded to 18 4000/300W=13.33, rounded to 13 Because all three conditions must be met simultaneously, a maximum of 13 * solar panels (300W, 28V VOC, 10A) can be connected in series.
@braianlopezacosta259
@braianlopezacosta259 4 ай бұрын
You are so pretty 😍
@leightonwalters
@leightonwalters 11 ай бұрын
How to change fuse pow-hvm3.2h-24v
@temank2741
@temank2741 11 ай бұрын
The fuse is usually located at the battery terminal. Use a multimeter to measure and see if the fuse is broken. If it breaks, you can search online for the same or similar fuses based on the current on the fuse to replace it. Alternatively, contact the seller of your order to apply for the original fuse.
@jonathanposerio3137
@jonathanposerio3137 Жыл бұрын
How about generator connection?
@temank2741
@temank2741 Жыл бұрын
The wiring method is the same as connecting to the Utility Note that if the input frequency and voltage of the AC generator are unstable, it may result in the inability to use AC power normally
@lobrothers9634
@lobrothers9634 6 ай бұрын
I can connect 4 pv 550w in series
@temank2741
@temank2741 6 ай бұрын
What is the open circuit voltage and short circuit current of each solar panel? Three conditions need to be met simultaneously: 1. The total input power of photovoltaics is less than 4000W, 2. Total PV current
@obiageliodi8734
@obiageliodi8734 11 ай бұрын
Can I charge it without solar energy?
@temank2741
@temank2741 11 ай бұрын
Yes, you can use the Utility or AC generator for charging
@obiageliodi8734
@obiageliodi8734 11 ай бұрын
@@temank2741 oh, thank you.
@temank2741
@temank2741 11 ай бұрын
You are welcome!@@obiageliodi8734
GroWatt Vs PowMr Update
9:30
Byron Young
Рет қаралды 11 М.
MISS CIRCLE STUDENTS BULLY ME!
00:12
Andreas Eskander
Рет қаралды 17 МЛН
Дарю Самокат Скейтеру !
00:42
Vlad Samokatchik
Рет қаралды 8 МЛН
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН
SAVE Thousands - Build your own home solar battery backup!
21:17
Projects With Everyday Dave
Рет қаралды 326 М.
Powmr Hybrid inverter screen
3:12
Postiemania
Рет қаралды 622
How to Install and Setup POW SunSmart10K Solar Inverter
18:42
PowMr Solar
Рет қаралды 15 М.
Detailed Solar Inverter Installation: A Step-by-Step Guide
9:17
PowMr Solar
Рет қаралды 23 М.
PowMr All in One and OFF GRID Solar Power Array Installation
10:04
EverythingNewUnderThe Son
Рет қаралды 31 М.
Why You Should Use 48V For Your Off Grid Solar System
22:07
Projects With Everyday Dave
Рет қаралды 102 М.
MISS CIRCLE STUDENTS BULLY ME!
00:12
Andreas Eskander
Рет қаралды 17 МЛН