No video

A closer look at flame rectification on a boiler

  Рет қаралды 9,379

Baxi - sustainable heating and hot water solutions

Baxi - sustainable heating and hot water solutions

Күн бұрын

Baxi Trainer Lance takes a closer look at flame rectification on the Baxi Duo-tec range of boilers.
Please note: This video is intended for Gas Safe registered engineers only and is subject to our full video disclaimer which can be found here: www.baxi.co.uk/video-disclaimer
For more information on Baxi Training: www.baxitraining.co.uk
For product information: www.baxi.co.uk

Пікірлер: 8
@benc1439
@benc1439 3 жыл бұрын
I recon they're the best combi around.
@pointyplumber
@pointyplumber 3 жыл бұрын
As always great lil video
@jamesjamesbond6894
@jamesjamesbond6894 3 жыл бұрын
FYI you will get a flame failure on the New 30Ga if the drain line is backed up The flame sensor and the high water sensor is wired in Parallel thus shorting out the signal. Unit will display flame failure...therefore the very first thing that should be done is.......you guessed it check condensation drain before you frig around with anything Your welcome 🙏
@mehmetaliciftci3495
@mehmetaliciftci3495 5 ай бұрын
Merhaba keşke Türkçe alt Yazı modunuda açık etseniz çok iyi olurdu
@muhammadAli-kd2zp
@muhammadAli-kd2zp 2 жыл бұрын
Thank you 🙏🏻
@josepeixoto3384
@josepeixoto3384 Жыл бұрын
we need 5 UA you say? what is UA, United Arab? emirates? tks also, what to do if there is no ignition, or no flame probe signal? will a bad flame probe prevent initial ignition or not? ...
@rickylin3214
@rickylin3214 2 жыл бұрын
What happens when you pull the flame sensing lead out PCB to test for 5uA, does boiler not knock off due to lead being removed as it cannot sense the flame? If it knocks off.. how are we gonna get any reading with no flame
@BaxiBoilersUK
@BaxiBoilersUK 2 жыл бұрын
Hi Ricky, When testing for flame rectification, you remove the rectification lead and with your multimeter set on uA, place one probe on the base of the rectification electrode and one on the lead, this completes the circuit and gives you a reading. I hope that this helps.
Different types of thermistors, locations and how to remove them from a boiler
5:47
Baxi - sustainable heating and hot water solutions
Рет қаралды 17 М.
Flame Rectification | How To Test | ACS Gas Learning NGCFE
13:59
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 19 МЛН
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
超凡蜘蛛
Рет қаралды 14 МЛН
❌Разве такое возможно? #story
01:00
Кэри Найс
Рет қаралды 3,8 МЛН
When you discover a family secret
00:59
im_siowei
Рет қаралды 22 МЛН
The correct procedure for refitting the combustion assembly on Baxi's stainless steel heat exchanger
7:41
Baxi - sustainable heating and hot water solutions
Рет қаралды 19 М.
Flame sensor, Flame rod, Flame Rectification
9:53
Love2HVAC with Ty Branaman
Рет қаралды 54 М.
Flame rectification and physics behind it  ( flame based diode )
18:42
High Voltage Engineering by MG Niasar
Рет қаралды 3,3 М.
E133 fault Potterton gold 28he faulty spark generator and electrode
14:49
The Mental Gas man
Рет қаралды 11 М.
FLAME SENSOR   FLAME RECTIFICATION.  EXPLAINED .  TROUBLESHOOTING.
23:06
Alex The Handyman
Рет қаралды 7 М.
Lockdown Learning - The recommended basic electrical safety checks you should perform
9:11
Baxi - sustainable heating and hot water solutions
Рет қаралды 27 М.
Gas Training - How To Service A Combi Boiler Baxi 105
33:37
Allen Hart
Рет қаралды 22 М.
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 19 МЛН