A quick review of the electrical and mechanical components of an air compressor starter circuit. How to check a starter capacitor using a multi-meter.
Пікірлер: 16
@richardcox733011 ай бұрын
Very good teacher clear and precise, well done ,,sir
@avispex6 жыл бұрын
Thank you for the video. It did a great job teaching me how to use a good meter to check for various problems. One minor point. At about the 5:40 mark you said "there is a "u" there." That is a lowercase greek letter mu, used for micro.
@PanamaSticks4 жыл бұрын
The start capacitor doesn't "charge up" to give the motor an "extra jolt". It changes the phase of the current flowing to the armature winding, which gives a push to the armature, to start it moving. Once the motor is up to speed, a centrifugal switch takes the start capacitor out of the circuit.
@richardcox733011 ай бұрын
I was told that they store voltage
@jeromedeangovender2173 жыл бұрын
Saved me alot of money thanks
@4556renard7 жыл бұрын
Thank you Mr !
@user-xv7eb5ct9f5 жыл бұрын
I have a Black Max air compressor (B165B500-25) it was working fine but now it wont start. It is getting power but wont start. What could the problem be ?
@rayunseitig63672 жыл бұрын
great thanks.
@starckmad17796 жыл бұрын
Thanks! Gives me a few more things to check besides brushes.
@anonimoporsiempre6033 Жыл бұрын
Does this type a motor has a brushes ?🤔
@836dmar3 жыл бұрын
The points in the switch have been an issue for me as well.
@rensnierden4 жыл бұрын
On wich stand u need to put the meter to test the capacitor???
@mikelambert2366 жыл бұрын
Mine worked 2x and quit no humm nothing ..no reset switch that I can find
@fluffymittens244 жыл бұрын
Kind of hard to hear you. Voice to back ground noise about equal. Voice or mic needs to be turned up