Evacuate & Recharge An AC system, Also Replace Schrader Valves

  Рет қаралды 29,624

APDTY

APDTY

Күн бұрын

AC Service Port Valve Core & Cap Kit = amzn.to/2yFbYtM
AC Gauges = amzn.to/3eLpQ6x
AC Recovery Equipment = amzn.to/2VQSKcN
R134a Refrigerant = amzn.to/3cM6QDb
00:00 - Intro
00:45 - Connect Gauges
02:36 - Set Up AC Recovery Machine
08:35 - Replace Schrader Valves
10:35 - Vacuum & Refill AC System

Пікірлер: 25
@VWtech562
@VWtech562 Жыл бұрын
Very good video. Just a few things I noticed.. only recover from low side, if you recover from high side you will remove oil. If tank is new it must be vacuumed out. Last but not least don't use quick disconnect fittings... they just make a mess specially when there is dye in the system, it wastes refrigerant and hurts the environment.
@snwdn
@snwdn Жыл бұрын
I have probably watched 20 or so videos on this topic. There is a lot of misinformation on KZfaq about this procedure, but your video seems to have all the correct steps in one easy to watch place. With this, as well as the supplementary information in the comments, I think this is the most comprehensive guide for automotive AC refrigerant recovery I have seen!
@ohiocountry4248
@ohiocountry4248 2 жыл бұрын
Thanks for explaining taking the time to make an excellent video. On more than one occasion you provided helpful insights not covered in related, more played videos. These insights are exactly what I am looking so a project doesn't turn into an all day / weekend event.
@vityok3000
@vityok3000 15 күн бұрын
Very important thing that was not mentioned. Every vehicle have its own refrigerant capacity. And it is very important to fill your system with exactly right amount of refrigerant for your vehicle. That the AC will work perfectly.
@Catchmeifyoucan209Stockton
@Catchmeifyoucan209Stockton Ай бұрын
Well from all the researh ive done i say you made 4 critical mistakes first you should of opened both valves on recovery tank if brand new to let the Nitrogen out that its shipped with. (Atmosphere is fine with nitro) second hooked a vacuum pump to the recovery tank and let that baby rip for about 30-60min to make sure its sucked of everything you can get. Think of it as you're the tank and best BJ ever didnt miss a drop. 😉 Next purge the hoses open valves up on manifold and recovery machine leave valve on tank closed then crack open the hose to tank fitting until you get refrigerent out then tight immediately. Finally only open the low side! Leave high side shut
@ooCHICOoo
@ooCHICOoo 10 ай бұрын
thank you for sharing my friend great 👍 video
@Rbenterprises4
@Rbenterprises4 Жыл бұрын
Good basic video. Where do you take the recovered refrigerant for recycling? Do they simply suck out your recovery tank?
@orinjackson6446
@orinjackson6446 Ай бұрын
Good video. You didn't mention about when charging the system back up .do the cans of refrigerant do they need to be straight up or upside down
@orabates1823
@orabates1823 Жыл бұрын
If that is a brand new recovery tank then you would first need to purge the nitrogen out and then draw a vacuum on it.
@Urs4
@Urs4 Жыл бұрын
Yes but this seems to be "empty"...
@_N_B_0496
@_N_B_0496 Жыл бұрын
Hey thanks for a very informative video! Question, do you know where the oil goes from the system when the machine recovers it? I used to work at a shop and our full size machine separated it into a separate canister. Does this one do that or does it send the oil into the recovery tank?
@Psikeomega
@Psikeomega 10 ай бұрын
So I just got my certificate so I’m gonna basically give you the textbook answer since I don’t have much experience quite yet. (More or less saying I have done this for 30 seconds and beyond the certification material I have no idea what I’m doing) Some of the oil will dissolve in the refrigerant. But most should stay in the compressor. The stuff that dissolves in the refrigerant could pool in the bottom of the recovery cylinder. There’s several hvac channels on KZfaq that show cut open recovery cylinders and a few have shown how much compressor oil pools in the bottom where the dip tube doesn’t reach. Interesting stuff if you’re a nerd like me that like looking up stuff like that.
@mrpaulvoline1275
@mrpaulvoline1275 Жыл бұрын
I have a question why not put the same freon back? Can you do that at all?
@VWtech562
@VWtech562 Жыл бұрын
Not really, it would be like taking a shower and collecting the water for next time. The refrigerant needs to be recycled.
@mrpaulvoline1275
@mrpaulvoline1275 Жыл бұрын
@@VWtech562 ok. I need explanation on this ??? What makes something like the Robin air 34788 machine different than what this guy has. Filters? And a vacuum pump I know. It just seems like I can reuse the freon. I use a filter when collecting and a filter when recharge so far so good
@VWtech562
@VWtech562 Жыл бұрын
@@mrpaulvoline1275 I'm on the same Page as you are. I've asked myself the same question. I use a Robinair roll around machine at work and all I do is replace the filter after 150 hrs. But how good that filter works when recovering refrigerant on burned-out compressors? In my opinion you would also need a refrigerant identifier to make sure there is no air or contaminated refrigerant before putting it back in.
@billiebowling7755
@billiebowling7755 Ай бұрын
New systems are very very temperamental 2 + 4 - any amount of refrigerant
@SWFLJetSkiRiders
@SWFLJetSkiRiders 2 жыл бұрын
Does the pag oil goes with the freon?
@jeffreyharbin5211
@jeffreyharbin5211 Күн бұрын
throw it directly into the line before adding refrigerant can/tank
@kylecartier2484
@kylecartier2484 2 жыл бұрын
Didn't purge the air out for the second can so you introduced a whole line full of air into the system.
@carlosgraphic
@carlosgraphic 2 ай бұрын
Not really, he has a valve on the can, when the first can is empty the valve is closed and the hose is airtight, no need to purge for a second can.
@marianmarzec-autotechnic9798
@marianmarzec-autotechnic9798 Жыл бұрын
Shiet 👀
@billiebowling7755
@billiebowling7755 Ай бұрын
Inaccurate way to determine how many ounces of refrigerant was introduced
@jbroseann1
@jbroseann1 2 ай бұрын
So we're gonna go ahead, we're gonna go ahead, we're gonna go ahead, we're just gonna go ahead. How many times can we repeat one sentence?!!! Shame because it's a good video. I just can't understand why todays Americans have to repeat that sentence all the time. It's annoying.
@lisacortez8079
@lisacortez8079 18 күн бұрын
Your annoying He was fine!!
How to Pull a Vacuum and Recharge Your AC System - ULTIMATE GUIDE - HVAC
25:45
How To Recharge an AC System - EricTheCarGuy
23:49
EricTheCarGuy
Рет қаралды 4,2 МЛН
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 7 МЛН
A little girl was shy at her first ballet lesson #shorts
00:35
Fabiosa Animated
Рет қаралды 12 МЛН
HVAC 129 Faster Recovery
15:29
Love2HVAC with Ty Branaman
Рет қаралды 89 М.
How to find leak when the A/C system is empty
6:29
realfixesrealfast
Рет қаралды 388 М.
If You Can't Find the Source of Your Overheating Issue Watch This Video
8:30
Ratchets And Wrenches
Рет қаралды 436 М.
AUTOMOTIVE HOW TO: A/C SYSTEM DIAGNOSIS FOR BEGINNERS
28:01
Rustbelt Mechanic
Рет қаралды 752 М.
Why You Should Not Recharge Your Truck or Car's A/C Yourself
4:25
1A Auto: Repair Tips & Secrets Only Mechanics Know
Рет қаралды 839 М.
How to recharge AC system with gauges properly and evacuate
17:03
How to Find AC Leaks in Your Car (UV Dye)
13:30
ChrisFix
Рет қаралды 4,7 МЛН
I can't believe Mechanics don't know How to Recharge AC system correctly!
7:46
NATES INTERACTIVE AUTO
Рет қаралды 4,2 МЛН
Байкеры помогли доехать маме и сыну 😯
0:20
Фильмы I Сериалы
Рет қаралды 2 МЛН
что за звук?
0:15
Мурат 07 манипулятор
Рет қаралды 1,7 МЛН
ФЭТБАЙК vs MTB Что лучше ? #shorts
0:21
Леха МАК
Рет қаралды 978 М.
PRADO 250 - классная машина!
0:28
Тарасов Auto
Рет қаралды 3,9 МЛН