Best New Generator GENMAX 10500iETC Tri-Fuel Inverer Generator!

  Рет қаралды 68,790

JOHNNY'S WEEKENDS

JOHNNY'S WEEKENDS

11 ай бұрын

The New Genmax 10500ietc is a great choice for home back up power, construction, or food trucks! #generator #inverter #grid #foodtruck #backuppower
The hose lenghts are 25Ft NG LPG 6Ft
ITEMS IN VIDEO………
Discount code only good from 8-2-2023 - 8-31-2023
USE CODE: 050809new At check out..👍🏼
Genmax 10500iETC: amzn.to/3rPSjmB
Power Watch dog: amzn.to/3DC3H8a
Direct Questions for fast response ...asqme.com/@johnnysweekends
CHECK OUT MY AMAZON STORE: www.amazon.com/shop/johnnyswe...
If you feel I helped you out..Buy me a Coffee 👍🏼🙌🏼👊🏼😀
www.buymeacoffee.com/johnny5120J
TopTes Gas Detector PEN!!: www.amazon.com/dp/B0B62LBZPC?
Trailer and vehicle accessories
www.etrailer.com/?etam=a0017
Lithium SOK Batteries Solar and more!! currentconnected.com/?ref=JW
Level your trailer FAST & EASY!!!!
Level mate pro: amzn.to/3S2xf5c
AWESOME BUDGET BATTERY Chins w/ low temp and blue tooth! amzn.to/3IOjVfv
MC4 All in one Kit : amzn.to/37jwLVb
BEST GAS CAN!! Surecan Gas can : amzn.to/3Kf5rqn
Protect Everything!! 303 Aero space Protectant: amzn.to/329dkM7
BEST FIRE PIT!! Outland Propane fire pit!! : amzn.to/3rKIkwZ
Generator tent amzn.to/3ddd3ds
Lucas fuel treatment: amzn.to/3IfxQv8
Videos are for entertainment purposes only. Do your own research when it comes to using these products shown in any Johnny's Weekends videos.
Thanks for watching. Above links are part of a affiliate program. As an Amazon Associate I earn from qualifying purchases, if you purchase something I earn a small commission, if you do thank you so much as it helps creators like me to continue to bring content for viewers.👍👊😊

Пікірлер: 220
@johnnysweekends
@johnnysweekends 11 ай бұрын
DISCOUNT BELOW The New Genmax 10500ietc is a great choice for home back up power, construction, or food trucks! #generator #inverter #grid #foodtruck #backuppower The hose lenghts are 25Ft NG LPG 6Ft ITEMS IN VIDEO……… Discount code only good from 8-2-2023 - 8-30-2023 USE CODE: 050809new At check out..👍🏼 Genmax 10500iETC: amzn.to/3rPSjmB Power Watch dog: amzn.to/3DC3H8a Direct Questions for fast response ...asqme.com/@johnnysweekends CHECK OUT MY AMAZON STORE: www.amazon.com/shop/johnnysweekends If you feel I helped you out..Buy me a Coffee 👍🏼🙌🏼👊🏼😀 www.buymeacoffee.com/johnny5120J
@pjperalta5298
@pjperalta5298 10 ай бұрын
Thank you for responding. This is really helpful information!
@Caldog101
@Caldog101 10 ай бұрын
Any newer coupon codes for September?
@johnnysweekends
@johnnysweekends 10 ай бұрын
@Caldog101 I don’t think I’ll have one for a couple weeks but check back
@Caldog101
@Caldog101 10 ай бұрын
@@johnnysweekends thank you!!! Post one when you have it!
@johnnysweekends
@johnnysweekends 10 ай бұрын
@Caldog101 I will, stay tuned and keep a eye out for a community post 👍🏼
@tristanschaper281
@tristanschaper281 11 ай бұрын
Great video - I think this unit is the new benchmark right now. They have literally packed everything possible into this unit, other than fuel injection and perhaps a bluetooth monitoring app like Honda now has. It's hard to imagine what Genmax has coming in the future!
@johnnysweekends
@johnnysweekends 11 ай бұрын
I agree finally someone coming out with new units that fit more of the bills
@ftlaud911
@ftlaud911 11 ай бұрын
Nice review!!! Seems like a solid unit with the likes of Honda or Predator options. They threw everything minus EFI at this model. Included battery charger is a new thing which shows they understand what consumers want. Kudos to Genmax for listening. With the included ATS this is a great solution for home use with a perma nent gas line. The problem with these units is fuel comsumption. If you have a lengthy power outage you need a large amount of fuel storage. For this reason I went with multiple smaller units knowing they sip fuel and can conserve if needed. With 40 gallons (8 cans) I can run for more than a week. This was tested after a hurricane. On the 4th day gas lines were significantly shorter and by 5th day you had access to multiple gas station options which were getting fuel delivered daily. I started refueling 10 gallons a day on day 6 just to be safe. By the 8th day I had power restored and used up my full 40 gallons. Ran 24/7 with 1 or 2 (night) and used 3 when needed during day. Only 120V so no hot showers :-(
@johnnysweekends
@johnnysweekends 11 ай бұрын
Thank you 👍🏼😀 And yes nice unit for sure for those wanting big power. The charger was my idea 😁👍🏼 I talked to them during the Vegas show for ideas and we have talked since so some things like the 12v coming back was also a idea I threw at them as well. 👍🏼 EFI…. Well…..that’s another idea as well 😁😉
@PJM454
@PJM454 6 ай бұрын
Thank you for sharing a very well done, very informative video that covered a lot of bases for someone like myself looking to purchase a generator invertor.
@YukonHawk1
@YukonHawk1 11 ай бұрын
You have a really nice camper. Thanks for the very informative video. Genmax has come a long way.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Thank you and glad you liked the video. Thanks for stopping by 👍🏼😀
@JoshLanners
@JoshLanners 11 ай бұрын
Thanks for the video Johnny! I have the predator 9500 and am very happy with it. If this existed when I bought it I would certainly consider for the tri-fuel.
@harryinoklahoma1866
@harryinoklahoma1866 11 ай бұрын
I was thinking the same thing Josh.
@ChatGPT1111
@ChatGPT1111 11 ай бұрын
Trifuel plus Inverter together is the only way to go. You have true SHTF capability plus you protect your sensitive electronics.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yup for sure 👍🏼
@Paulwilliams203
@Paulwilliams203 11 ай бұрын
Now that can pump out some power! Nice bit of kit but not cheap
@charlesklaus6290
@charlesklaus6290 11 ай бұрын
Very nice unit! Thanks for another good review!
@johnnysweekends
@johnnysweekends 11 ай бұрын
Thank you Charles 😀👍🏼
@x12z12
@x12z12 10 ай бұрын
Thanks for the awesome review!
@johnnysweekends
@johnnysweekends 10 ай бұрын
You’re welcome 😀👍🏼
@Badgeweefixstuff
@Badgeweefixstuff 5 ай бұрын
That is very impressive very quiet awesome video 🛠️🇨🇦🛠️🇨🇦
@johnnysweekends
@johnnysweekends 5 ай бұрын
Thanks 👍🏼😀
@BradiKal61
@BradiKal61 11 ай бұрын
Genmax certainly is a leader in features but my concern would be parts and service. Still I am impressed by what Ive seen here and on Gavins Garage
@Dive-Bar-Casanova
@Dive-Bar-Casanova 10 сағат бұрын
Thats our concern too. We have the Powerhorse 7500 Inverter and have unresolvable issues. We'll get the GenMax 10500 if parts and advise is available. We love out GenMaxs, all bought on Johnnys recommendations. Wish they were as quiet at the Harbor Freights.
@johnnysweekends
@johnnysweekends 9 сағат бұрын
I have been telling them to make the units quieter
@YouTubeviolatesmy1stamendment
@YouTubeviolatesmy1stamendment 11 ай бұрын
So I was actually looking at getting another generator for after my Honda wears out and originally I had just leave ignored these genmax brand because I thought they were junk But now I'll have to go back and look at those
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea they are coming along well. And now that I’m seeing more and more of the eu6500 and eu7000fi units having so many issues and at that price, it’s hard to justify it. But I stop recommend a warranty with most any of these no matter the brand
@joshua1577
@joshua1577 11 ай бұрын
that sine wave was actually pretty impressive in my opinion for how much load you were pulling. Im impressed! How is Genmax's warranty as well as parts availability. Those are my 2 biggest worries for something like that. Something beneficial about honda's is their parts are available for a long time (priced like gold chains thought)
@johnnysweekends
@johnnysweekends 11 ай бұрын
When I was in Vegas with Genmax they said they were camping up parts availability for there models and customer service. The parts warehouse is in sandiego but some parts are a little universal which can be found on eBay and such. But now they have thing you can replace and fix. But yea Honda you can get parts for a while. Although my inverter board for my eu3000is was discontinued and no superseded number was available so I got rid of it
@joshua1577
@joshua1577 11 ай бұрын
@@johnnysweekends oh wow that sucks. Maybe thats because they released the Eu3200i? I do know that if fuel injector parts fail they are expensive to replace. I saw that the fuel injectors for the EU7000IS are like 550$. Maybe thats why Genmax hasnt gone fuel injection. Does fuel injection matter to you?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Fi has its pros and cons like anything. For me I’m a pretty mechanical guy so I don’t have a lot of issues when it comes to storage and such. I under loads and jetting and more. A carb swap and parts are cheap like $30-$60 and doesn’t take long to swap small engine carbs. If fuel injection is new then parts will be spendy for a few years till there is a lot of parts and also aftermarket as well. It does start nice and is more fuel efficient so…again the pros and cons
@0lloydb
@0lloydb 7 ай бұрын
Great video! You should ask Genmax when the 7250 TRIfuel will come out.
@johnnysweekends
@johnnysweekends 7 ай бұрын
I will. They should have more new coming
@yolo_burrito
@yolo_burrito 11 ай бұрын
The sine wave distortion right at 0v is probably due to no physical ground to reference. Read the manual it probably has a spot for a ground jumper if the connection you’re plugging into doesn’t have an earth ground.
@johnnysweekends
@johnnysweekends 11 ай бұрын
😀👍🏼
@TOURMANBOB
@TOURMANBOB 5 ай бұрын
I have been considering converting my Honda EU6500i to run on natural gas. However, the additional cost is about $1000 for the kit and the natural gas guy to convert the barbeque outlet so I can hook up the generator. Instead, I would sell this Honda unit and buy the Genmax 10500 unit and have money in my pocket....but..but...it's not available in Canada and parts and service availability are minimal right now (and non existent in Canada), and the quality of the unit is still unknown (although I would take a chance on that). Maybe this will be doable some time in the future....(sooner rather than later I hope)
@johnhelms
@johnhelms 3 ай бұрын
I think it could be bonded or not or try ground rod. It might fix it, still would be a good experiment.
@SaabAholic
@SaabAholic 11 ай бұрын
I can’t afford you anymore, Johnny, lol! Great review as always!
@johnnysweekends
@johnnysweekends 11 ай бұрын
NO!! Jeff, DONT LEAVE ME…!!! 😂 I’ll review something cheap 😂 Thank you again 😁👊🏼👍🏼
@LTDan-hu5fq
@LTDan-hu5fq 5 ай бұрын
I just bought this model on amazon for 2,300.00 bucks! that's about 900.00 less then normal price!
@johnnysweekends
@johnnysweekends 5 ай бұрын
Wow !! Smoking deal, good job. Say hi to Forrest for me…😉😁
@cayrick
@cayrick 11 ай бұрын
Nice generator. My advice for purchasers is to get rid of the GFI outlets. I had them on my Honda until it decided to shut off while unattended.
@johnnysweekends
@johnnysweekends 11 ай бұрын
They can be a little finicky depending on load or what’s plugged in. I noticed this to sometimes and was wondering gfi or the load and some tripped. But more and more I’m wondering if the gfi is causing the issues
@cayrick
@cayrick 11 ай бұрын
In the case of my Honda 5000 SX my gen was in a compartment and the GFI outlet ran a cooling fan. The GFI tripped but caught it in time. The manual states that this generator should not be used in medical applications. Now you know why! Reliability. When this happened to me the GFI's came out the next day. Unfortunately in our litigous society the manufacturers have to cover their collective butts. @@johnnysweekends
@mikecon7634
@mikecon7634 11 ай бұрын
Right on JW
@johnnysweekends
@johnnysweekends 11 ай бұрын
Beast mode generator!! 😀👍🏼
@AdamFeldman42
@AdamFeldman42 11 ай бұрын
Is the fuel selector a solenoid or motorized ball valve? I read about the solenoid failing on similar models.
@johnnysweekends
@johnnysweekends 11 ай бұрын
It’s a electric piston that goes in and out to allow fuel to flow or plug it.
@deadonleprechaun
@deadonleprechaun 11 ай бұрын
🤤 Hell yes!
@johnnysweekends
@johnnysweekends 11 ай бұрын
👍🏼😁
@rickbraden4272
@rickbraden4272 11 ай бұрын
Great video. Do you know what the max continuous power at 120v?
@johnnysweekends
@johnnysweekends 11 ай бұрын
I’ll be doing a designated full Load test probably next week. The book says 6000 watt at 120…but the generator spec sticker says different. Wouldn’t be the first time I have seen a Misprint on the one or the other. So will see.
@bobn8865
@bobn8865 11 ай бұрын
Very nice gen set with all the bells and whistles. It is expensive, $2900.00.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea little spendy but I do have a discount code 😀👍🏼
@hardtruth2039
@hardtruth2039 3 ай бұрын
Can you use the 14-30 240v plug and the 14-50 240v plug at the same time? I’d like to run my house on the 14-50 plug while my 2 Delta Pro’s w/ 4 extra batteries quick charge from the 14-30 plug.
@johnnysweekends
@johnnysweekends 3 ай бұрын
Yes but still limited to the normal range of power
@DigitalJazz
@DigitalJazz 11 ай бұрын
That little bit of distortion it’s honestly probably caused by the quality of wire in the RV. harmonic oscillation is what is probably happening. At least from my limited knowledge.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea from my studying it was not true distortion from the unit. At least that I know off. But yea agree probably the trailer lol. They are all cheap lol
@kentgoss9209
@kentgoss9209 11 ай бұрын
I have the 9500 of this unit.purchased mid last year. Can this one run in parallel even though it has a slightly higher output? THX
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yes you can parallel both 👍🏼😀
@justkrook
@justkrook 8 ай бұрын
great vid Johnny. When do you think the fuel injected unit will be dropping?
@johnnysweekends
@johnnysweekends 8 ай бұрын
Well we will see…😁
@michaelorr430
@michaelorr430 9 ай бұрын
Do you have info on the applicable auto transfer switch?
@johnnysweekends
@johnnysweekends 9 ай бұрын
Genmax is working on their own but waiting to get us cert. I dont know of one here yet with out modifying that will work
@jessenoble1399
@jessenoble1399 Ай бұрын
Looking at running my whole home but cant decide between an inverter or just regular generator and do i really need an in verter generator looking for some input
@johnnysweekends
@johnnysweekends Ай бұрын
You don’t need an inverter Gen unless you have sensitive electronics or certain items that require an inverter generator like maybe power stations from Ecoflow or Bluetti. But big back up batteries like Enphase or telsa can use a regular generator. They are normally quieter and more fuel efficient but more expensive and heavier
@jessenoble1399
@jessenoble1399 Ай бұрын
@@johnnysweekends thanks alot only thing would be tvs maybe washing machine and idk about the washing machine electronics where it's a newer washer so now deciding on a generator thanks a bunch again
@ChaJ67
@ChaJ67 Ай бұрын
It could be interesting to see someone crack the code for how to actually use the ATS. Great and all there is a cable there, but what do you plug it into? It seems there is some vaporware ATS box out there, but otherwise not sure what the average Joe is going to do with that plug. A quick look at the manual makes me think you could possibly control this with an R-Pi, some relays, and maybe some other hardware. Just have to figure out the nuances for sending the control signals before programming the R-Pi, but shouldn't be too difficult. If I understand correctly, start and emergency off are both pull-downs to ground and running is 12V off of the alternator. So going through the pin-out, you have 12V power, ground, a start pin to pull down to ground with a relay, an emergency stop pin to pull down to ground with a relay, and a 12V running power pin. So once you have these pins in order for your setup, then you need to signal your main power relays to break from shore power and attach to generator power while being careful to never have shore and generator power hooked up at the same time. It sounds doable, but then you gotta actually get it right. Then you need to get sign off to actually use it if they will even let you use whatever you cobbled together. The R-Pi programming might be pretty dumb in that it is more of a timer with some sensing. You may also put some extra circuitry to make it impossible to to have generator power and shore power connected at the same time in case there is a coding error, a problem with your wiring or even a fault with one of your relays. So: 1. Normal: Sense if shore power is there. If shore power is available, sleep X time and check again. If shore power is lost, wait X number of seconds, check again, and then move on to Start. 2. Start: Loop that senses for 12V running power. If no running power, then close and then open the 'start' relay to start the generator and wait X seconds for generator to start. Else (there is running power), break out of Start loop. 3. Warmup: a. Sense for generator 240V power. If generator 240V power does not come on after X number of seconds, then go back to start. b. (Generator 240V power detected) Sleep for X seconds while generator warms up, then proceed. 3. Run: After start, go here. a. Check once more for shore power, if not detected, disconnect shore power. Else (shore power detected), go to Stop. b. Wait 1 second and then connect generator 240V power relay. c. Loop checking for shore power sense and doing short sleeps between checks. If shore power is detected, sleep for X seconds and check again. If shore power still there, break out of loop. d. Shore power considered back, disconnect generator relay. Wait 1 second and then connect shore power relay. e. Wait X number of seconds (Cool down). Check if shore power is still there. If it is not, go back to top of Run. Else go to Stop. 4. Stop: Connect and disconnect 'stop' relay to trigger the emergency stop of the generator. Go to Normal. Note: If the generator 240V breaker trips, this ATS controller routine will not know by design. The thought being a human should get involved at this point, fix the cause of the breaker fault, and then reset the breaker. Note: If your 240V generator breaker is off, then this will harmlessly go between Start and Warmup without performing any actual actions, just checks. This will make sure the generator is ready once you notice this breaker is off and possibly restart the generator in case you turn it off while trying to figure out what is going on. Or if the generator stalls for whatever reason, it will try to restart it. Once you flip the 240V generator breaker on, then this will just move on and get things switched over to using generator power.
@johnnysweekends
@johnnysweekends Ай бұрын
They are having problems with UL listing and certificate fees which I guess are super spendy
@ChaJ67
@ChaJ67 Ай бұрын
@@johnnysweekends I suppose another thing is I saw someone go into one of the vaporware boxes out there and there was no central relay. Instead there is a relay for each side, shore power and generator power and they just tie together into one set of output lines. I would think you would want a relay where both inputs go into with one set of outputs and then it does a break before make switch mechanically with a single physical mechanism for all poles. The idea being it is physically impossible to back feed generator power into the grid. If the switch fails, then either it is stuck on one of the two inputs or it is stuck off. If instead you have what I saw in the vaporware ATS, if one of the relays has an issue, there is a risk of say the generator relay getting stuck on, even if small, then shore power connecting back or something to the like and causing a backfeed issue with a high powered generator. That could be bad. Even if it is rare, the B737 MAX dive like crazy issue ultimately happened when a sensor malfunctioned and without proper engineering, that led to two whole plane crashes and loss of all hands. So inherently safe is good.
@MJF40
@MJF40 11 ай бұрын
If I didn’t have my EU7000 I’d jump on this. The additional power isn’t needed til I need an electric stove 😉
@yolo_burrito
@yolo_burrito 11 ай бұрын
Same, though I doubt it has the longevity of a Honda.
@MJF40
@MJF40 11 ай бұрын
@@yolo_burrito Agree ! I just wish Honda and Yamaha would advance their units more.
@johnnysweekends
@johnnysweekends 11 ай бұрын
You could buy almost 3 of these for one Honda and have more power and probably still be ahead. Go read the problems with the eu7000 EFI units. Not cheap to fix
@tibzig1
@tibzig1 11 күн бұрын
Completely untechnical person here. I was told that you can have an electrician provide you with a plug/box next to your main fuse box and you can plug a wire from this generator into it. Then you can use your switches/appliances in the house normally without having several wires all over the place. Is that correct?
@johnnysweekends
@johnnysweekends 11 күн бұрын
Yes 👍🏼
@tibzig1
@tibzig1 11 күн бұрын
@@johnnysweekends Thanks!
@simplecyberclub
@simplecyberclub 8 ай бұрын
I recently purchased this unit and works exceptionally well other than the minute/hour meter resetting and when i turn it off using propane. I always get a small backfire after turning off the controls in order according to the directions. The spark plug is gapped correctly, so it just may be the LP in the line. Does anyone else have this pop at the end? Should i turn the LP off first, then the switch to off? I've been shutting it down using the power off button, switch, and then LP off.
@johnnysweekends
@johnnysweekends 8 ай бұрын
Hello, couple tips. Ditch the stock Torque spark plug and get a NKG and then if only running LPG close the gap to about .018-.020ths. Also turn LPG off first to clear the line till gen dies. Then shut off the rest. Unless you are going to run it on and off a lot. But if shutting off for the duration or several hours like 8 or more best to close tank.
@johnnysweekends
@johnnysweekends 8 ай бұрын
A little back fire is normal with LPG some do it and some dont
@KillerRaptorr
@KillerRaptorr 9 ай бұрын
Good generator. 6000watts on natural gas isn't to bad. Can run a pretty good single person house with that or small family that isn't power hungry for energy. If your system has a well or city pump that isn't unpowered in a black out. You'd just hook this badboy up and run off gas to energy. Stick this sucker in the garage or a shed and run a hose extender for the exhaust out to a exhaust vent and you should be golden. No thieves to slap on or take the machine and it'd be way quieter from the other houses. From the looks of it. Natural gas will run a house at 6600watts either from the 220-30amp twist or the 4 pin 240-50 (at half power.). Kinda shame they only give the 8500watts to gas. And 8000 for propane. But if you're energy light for basic for AC/Heater system, Washer/gas-drier, Fridge, Gas water heater, gas stove/oven. You should be able to work for the rest of the stuff without any problems unless you're packing quite a few desktop PC's running over 500watts on a family set per kid/hobby/wife deal. Thought if your house is mostly electric of the AC/-Heater system, Water heater, Stove/Oven, and Drier. I'd say not to run those roughly at much on generator mode. AC/heater can already cook over 3000-4000watts for a Central system. Electric Drier will probably cook over 1500watts running. Electric stoves run 1000watts almost per burner. Not continuing the oven coil. And water heater probably cooks around 1500 or more watts or so when it clicks on. So for people who are more on the gas drive will probably be able to easily fly in a black out if it's local and not shutting your water or gas vines offline to. (Though i bet the gas bill will sky rocket lol.)
@MorCoutureMenswear
@MorCoutureMenswear 5 ай бұрын
Does the battery have to be charged in order for the pull start to work? ty
@johnnysweekends
@johnnysweekends 5 ай бұрын
Propane works with no battery and pretty sure gas does as well but you need to manually choke it. Sorry I don’t remember… May have to check again if both works
@machaf
@machaf 11 ай бұрын
Any idea when the Genmax 4000 EFI is coming out?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Hoping to have it by end of the month or sooner 👍🏼
@rchapoteau
@rchapoteau 11 ай бұрын
Pending on how much the discount gets off I might go with it. I really want this with just the dual fuel. I don’t need the natural gas and I’m sure that’s adding to the expense of the unit. I could pull the trigger on the 9000 but the extra power on this gives me fomo.
@johnnysweekends
@johnnysweekends 11 ай бұрын
$120 I think will be new discount since it’s been a little weird on the codes. Waiting for new one
@johnnysweekends
@johnnysweekends 11 ай бұрын
New discount code amzn.to/3Yu0DEL Code: 050809new
@TexasScout
@TexasScout 2 ай бұрын
I could not get the link for the generator to open. It says it couldn’t find that page
@johnnysweekends
@johnnysweekends 2 ай бұрын
It’s out of stock.
@leguirerj
@leguirerj 11 ай бұрын
How long is the natural gas hose?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Hey Roy it’s 25ft 😀👍🏼
@carperdiem8754
@carperdiem8754 4 ай бұрын
Does this use a carburetor or is it efi? I need something that can go from high to low altitude
@johnnysweekends
@johnnysweekends 4 ай бұрын
This is a carb unit.
@standlegweak9854
@standlegweak9854 11 ай бұрын
A little off topic, apologies if you've answered this, but do you know if there will be a factory Predator 9500 with propane?
@johnnysweekends
@johnnysweekends 11 ай бұрын
I don’t know of one in the works yet…. “Yet” So will see what comes late this year or next
@standlegweak9854
@standlegweak9854 11 ай бұрын
@@johnnysweekends Wow you get back fast, you gotta be the hardest working man in youtube! Sounds promising, thanks.
@johnnysweekends
@johnnysweekends 11 ай бұрын
I try 😂👍🏼
@DigitalJazz
@DigitalJazz 11 ай бұрын
Does the parallel port for these generators produce 415V and give you 3 phase
@johnnysweekends
@johnnysweekends 11 ай бұрын
No parallel only double amps….
@DigitalJazz
@DigitalJazz 11 ай бұрын
@@johnnysweekends damn it would be cool if you could get three phase by running two of them
@johnnysweekends
@johnnysweekends 11 ай бұрын
You need a larger unit, like on a trailer 😂👍🏼
@jbhobbyist9372
@jbhobbyist9372 20 күн бұрын
By leaving this in a generator shed during cold winter months will it harm the inverter?
@johnnysweekends
@johnnysweekends 20 күн бұрын
No it should be fine as long as it’s not getting wet. Moisture could cause corrosion even if they are sealed connectors it still finds its way in
@Neeboopsh
@Neeboopsh 11 ай бұрын
not in stock on the amazon link. how much is this? only says "Currently unavailable" and doesnt list a price ;) if i'm upgrading my 5000w dual fuel gasoline/propane, this looks like a nice unit. for those concerned about the lack of fuel injection, if you're running natgas or propane, it bypasses the carb, so you never need to clean the carb if you dont run it on gasoline
@johnnysweekends
@johnnysweekends 11 ай бұрын
Very true statement…! I’ve said this but maybe I’m not clear enough lol. 😂 Oh see if this works…. Shows it does but yea it could be out of stock already 🫤 Make sure you use promo code amzn.to/3OO24uy
@MrCKM1962
@MrCKM1962 10 ай бұрын
So if you are using this above 5000 ft MSL do you need to re-jet the carb? Or better question if you burn LP only does that mean you do not have to worry about using it above 5000 ft?@@johnnysweekends
@johnnysweekends
@johnnysweekends 10 ай бұрын
@MrCKM1962 hello, yes a carb reject will be necessary if you use gasoline above about 3500ft unless you plan to only use it for a few hours or so. Long term continued use then yes a reject. If using propane then no reject is needed…😀👍🏼
@tylerpickersgill
@tylerpickersgill 10 ай бұрын
Definitely need a regulator in gas line
@ClintEastonz
@ClintEastonz 8 ай бұрын
The comments on Amazon have been split at best, especially around the supply chain concerns when issues arise and receiving the actual continuous watts. Anyone own this unit and can comment?
@johnnysweekends
@johnnysweekends 8 ай бұрын
So far mine is doing fine but that’s only one. Even then only a few hours. But yea would like more feedback my self
@sarahlawhorn7955
@sarahlawhorn7955 11 ай бұрын
Hey Johnny! Your discount code isn’t working for me…Please advise.😢
@johnnysweekends
@johnnysweekends 11 ай бұрын
Hi Sarah, I’m hoping to have the code fixed by tonight or sooner. I’ll make a post about it and update the code and also try and remind you it’s working. Thank you and sorry, I didn’t have any control over that 😒
@johnnysweekends
@johnnysweekends 11 ай бұрын
New code…amzn.to/3Yu0DEL Code: 050809new
@richryan6326
@richryan6326 11 ай бұрын
how long are the lpg and ng hoses?
@johnnysweekends
@johnnysweekends 11 ай бұрын
25ft for NG line 👍🏼 but lpg is only about 6ft because you would hook to a bottle. Easy to get a longer line
@Legendary_UA
@Legendary_UA 11 ай бұрын
Is there a restriction on how long a NG line could be?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Not really just size will have to be larger as you get longer.
@joshua1577
@joshua1577 11 ай бұрын
I would like to see a direct head to head vs the predator 9500. Predator is 6.8 gallon tank, 18.5 hours at 25% load which is 1900w continuous. This genmax is a 6.9 gallon tank rated for 14 hours at 25% load which is 2125w continuous. So in terms of efficiency per watt, it appears the predator is more efficient. The predator is about 20% more efficient per gallon than the genmax. I did a bit of math and it appears the predator provides about 5169wh per gallon while the genmax provides 4311wh per gallon. If anyone was curious. This would mean the predator would go through a gallon of gasoline in about 2.72 hours while the genmax would go through a gallon in about 2 hours. Overall predator is more efficient but genmax has slightly higher output 7600w continuous on the predator vs 8500w on genmax. If anyone has anything else to add/correct please drop a reply below! Good video Johnny! Let’s see that head to head 😤
@johnnysweekends
@johnnysweekends 11 ай бұрын
Thank you. So some things that are different Predator $2499 Genmax $2899 Predator gas only Genmax tri fuel and includes all accessories Genmax longer standard warranty Genmax remote start Genmax quieter Genmax lighter by a couple pounds Genmax more output power Genmax cool display and a light 😂😁👍🏼 Genmax 3% THD Predator 5% THD Now fuel consumption……I think they are all wrong as again it’s a pretty controlled test. So many variables like load and ambient temp can give different real world results Now predator says .37gph @25% load Genmax in the manual says 2.195 l/h or .58gph. They have almost the exact same size engine. 458cc genmax, 459cc predator. I can’t imagine they can be that far off unless Genmax runs a much richer condition than the predator which means they run a real lean mixture. So fuel tests very a lot unless you do the same unit on the same day with the same amount of fuel using the same Load. Sure can be done, but odd they would be so much different. Maybe the predator is more efficient gas wise…🤷🏼‍♂️ But the Genmax wins mostly everywhere else. So until a definite fuel test can be done won’t know for sure. Good post for sure to give some back and forth pros and cons 😀👍🏼👊🏼
@joshua1577
@joshua1577 11 ай бұрын
@@johnnysweekends for sure, I didn’t bother comparing the other options but the trifuel on the genmax is my attention grabber. I would like to see you test all of the claims you mentioned above though! I’m a bit apprehensive trying genmax due to the tests project farm noted with the 2000w one. Higher wear metals, not full sine wave, etc. I would just like to see claimed results vs real world results for both! I think that would be an awesome comparison! Perhaps a bit long but I think it would see which is the “cleanest” power wise and which is the most accurate on their claims! Thanks for the reply Johnny!
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea the wear metal test was skewed, I told him when doing this on generators you need to change the oil once or twice to remove the assembly grease. It’s a flatly looking grease they use to lube the engine while it sits on the shelves and can skew the oil analysis test. So hopefully he does at least one or two oil changes before the oil analysis next time to wash the engine.
@joshua1577
@joshua1577 11 ай бұрын
@@johnnysweekends the oil test at the end was the second oil change for all generators in that video. Halfway through the testing he changed the oil after that had ran for a few hours. The oil analysis at the end was the second oil change after close to 100 hours on each generator so each generator did have a flush oil change ran though prior to the oil being analyzed. This is why it is worrisome. It’s not required in the manual to change the oil so short (within 2 hours like he did) but that first oil change should have gotten rid of any contaminants/etc. so the second oil change was a accurate result of normal use. The predator shut off from low oil during that test which isn’t good but the genmax is wearing metal in the engine for sure. You should do a engine oil analysis on this one to see if that is a model specific finding etc!
@johnnysweekends
@johnnysweekends 11 ай бұрын
Interesting I’ll have to rewatch. I watched it when it first came out so been a while. Plus I don’t have the excess funding Todd has 😂 but I’ll have to see what the costs are
@dougharlow6037
@dougharlow6037 11 ай бұрын
Is there a fuel injected model?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Not yet. Maybe next year. Pros and cons of that but would be nice for some things for sure.
@Legendary_UA
@Legendary_UA 11 ай бұрын
How does this compare to DuroMax?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Which model…?
@FullSendPrecision
@FullSendPrecision 11 ай бұрын
These are suspiciously inexpensive.... It makes me concerned about the longevity of the units... but I've REALLY been needing a 120/240v inverter genset... and for the cost they seem like they're worth the risk
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea I agree but like some things, I think this is a intro price like the new predator. I think in 6 months this could go up a few hundred dollars. Same as the new small predator. I bet it goes up as well.
@FullSendPrecision
@FullSendPrecision 10 ай бұрын
@@johnnysweekends - Well, I ended up with a 6000 watt model.... So far so good.
@johnnysweekends
@johnnysweekends 10 ай бұрын
@FullSendPrecision nice 👍🏼 keep me updated. Always good to know how everything is holding up
@rrvil
@rrvil 11 ай бұрын
Great review. Any idea when the discount code will be active?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Hopefully this eve or sooner. If not tomorrow morning at the latest. Sorry for the confusion on this, out of my control 😕
@johnnysweekends
@johnnysweekends 11 ай бұрын
New code amzn.to/3Yu0DEL Code 050809new
@chimpera1
@chimpera1 11 ай бұрын
@@johnnysweekends how much
@johnnysweekends
@johnnysweekends 11 ай бұрын
I think it’s $145 off..
@AntonioEdmonds
@AntonioEdmonds 7 ай бұрын
Any new codes?
@paul9387
@paul9387 11 ай бұрын
Johnny, Genmax updated its version, as far as I know. Am I wrong on this one? If not, I'm assuming the one off Amazon is being the updated one, correct me if I'm wrong please!
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yes this is the latest and most updated unit in the line. All the other new units will be coming out soon as well. Those will all be smaller units
@paul9387
@paul9387 11 ай бұрын
Sweet! I'll get one off your link, did you fix that promo code thing by the way? My wife will be thrilled that I saved a buck when I tell her 😜 I've been waiting for that puppy for months, cant wait to start it up and see how it works. Already have 30amp and 50amp inlets installed with an interlock switch.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Definitely tell the wife how much you saved. That’s a woman’s favorite line. Babe, guess how much?? No guess!! 🤣🤣
@johnnysweekends
@johnnysweekends 11 ай бұрын
Ohh and no not yet I’m waiting for them… hopefully in a couple more hours.
@paul9387
@paul9387 11 ай бұрын
@@johnnysweekends 🤣🤣 she already knows there will be a new gadget. Johnny, I've spent over 10k so far on my garage, and it started with making a spot for this Genmax, I just "went with the flow" 😬🤦😜
@zasde35
@zasde35 10 ай бұрын
Generac is terible in spare parts like control cirquit board and if you can find one it cost a crasy amount of money .
@fb510m
@fb510m 11 ай бұрын
How much i save w your discount code?
@johnnysweekends
@johnnysweekends 11 ай бұрын
It’s a $100 or a pinch more..🤔
@johncarr123
@johncarr123 11 ай бұрын
Any special deals they offering through your channel?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yes a discount code or “new” code is being created. The original one has a problem so its created a delay. Hoping any time I should have it back up and posted. Check back or ill repost here
@johnnysweekends
@johnnysweekends 11 ай бұрын
New code amzn.to/3Yu0DEL Code: 050809new
@johncarr123
@johncarr123 11 ай бұрын
Just used your discount code on Amazon. Thank you for posting
@johnnysweekends
@johnnysweekends 11 ай бұрын
@johncarr123 you’re welcome 😀👍🏼
@Arctic513
@Arctic513 2 ай бұрын
Not available anymore
@pjperalta5298
@pjperalta5298 11 ай бұрын
I am looking for a tri fuel inverter generator for my 1400 sqft home. No less than 9k run time on NG. I would like to have an inverter generator but the only tri fuel with enough watts was a tri fuel Duromax and it doesn't have an inverter. I need it to last days at a time in case of natural disaster. I have been searching for some time and no one has been able to give me enough information to make my decision. It's a lot of money so I need all the helpful information I can get. If I have to go with a non inverter, I guess it would be the Duromax XP13000. I like the Champion tri fuel inverter but dont think it will have the power Duromax does.
@johnnysweekends
@johnnysweekends 10 ай бұрын
Well I think no matter what no one can give you the correct answer. Some people can get buy with a 2200 watt unit which sips fuel. But only powers some basics. The Genmax is a nice unit and should power most anything you need. But normally when the power goes out you sacrifice and power what you need. Do you need to power one fridge and maybe wifi if it even works? Maybe two fridges and coffee ? Or the whole home and ac as well. It all depends what you can live with and for how long. A large generator burns a lot more fuel. Especially using natural gas. Just not as many btu’s so you get lower power out put just like it says on the specs. If you don’t want to worry about power and always have enough then the Genmax will fit a lot of needs. Just know it will burn more fuel. If you don’t need as much then a medium sized unit can save on space, cost and fuel. So once you decide what you really need to power then you can decide on a small, medium or large unit.
@pjperalta5298
@pjperalta5298 10 ай бұрын
@johnnysweekends I believe, after reading all the comments, this Genmax would be the better generator for our home. I'm figuring in the possibility of medical equipment for my Mom in the future.
@johnnysweekends
@johnnysweekends 10 ай бұрын
@pjperalta5298 definitely good for whole home back up but if you only need a couple devices a smaller unit would save a lot of fuel. Build you need to power large devices then this will cover most everything you need 👍🏼
@chalemi6909
@chalemi6909 9 ай бұрын
I was under the impression natural gas didn't need regulating?
@johnnysweekends
@johnnysweekends 9 ай бұрын
Still need a load regulator.
@jonsimone3111
@jonsimone3111 11 ай бұрын
Are there Chinese motors in these? Also from what I’ve seen the Honda eu7000is is severely underrated, there are videos of it putting out almost 10000 watts. What is your take on that? I do want to buy an inverter but having a hard time making a decision, price will not affect my choice. I just want the very best most reliable for an extended emergency. Thank you, also you made an EXCELLENT informative video.
@johnnysweekends
@johnnysweekends 11 ай бұрын
All the new gens even the Yamahas are coming with Chinese made engines. The eu7000 is or was a good unit but in the forums and groups several are having problems with injection pump and a couple other items which is showing to be a spendy fix. Especially if the dealer does it. One post on there a eu7000 efi was under warranty and the dealer couldn’t get Honda to cover it, and the part wasn’t even available for several months. So that’s a $7000 paper weight plus the repairs. Honda is still good but I dont know if they are reliable like 10 years ago and more. I always recommend a insurance plan / warranty when buying.
@americannumber2
@americannumber2 11 ай бұрын
Inverver
@mwahlert
@mwahlert 11 ай бұрын
If you have a contact at Genmax, ask them if it might be possible to introduce a model with significantly more momentary starting wattage from idle speed. I have a Predator 9500 right now. It has no trouble starting my 2.5T reciprocating compressor AC with a soft start, but it struggles to do the same from idle. Same thing with my well pump. Once stabilized my house rarely draws more than 5kw continuous. If they could pack some more reserve capacity into the inverter electronics everyone would benefit. 15k peak (1s max) would be amazing. PS: This is still splash lubrication, right?
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yes still splash lub. But the engine needs to be revved up so it can handle the load when applied.
@mwahlert
@mwahlert 11 ай бұрын
Of course, I fully expect an inverter genset's engine speed to vary by load. The point I was trying to make is such that when these units are idled down their momentary max output is limited primarily by the inverter electronics. If the manufacturers can beef up the reserve capacity in the inverter circuit (larger capacitors?) the starting loads could be handled with less dependence on the engine speed rapidly increasing. Certainly, this comes with a higher price tag, but I think it would be worth the cost of admission. With soft starters installed on my 2.5T AC (reciprocating compressor, not scroll) and my 1HP well pump, my Predator 9500 has no issues starting either of them when it is running full speed. If I've got the genset idled down in "eco mode" it can start the well pump without too much fuss, but sometimes the AC soft starter will fail to start the compressor because of inadequate current available. It is usually successful on a second attempt. All that said, when I run the genset in the summer months I usually end up leaving it at full speed so the genset isn't caught off guard. @@johnnysweekends
@johnnysweekends
@johnnysweekends 11 ай бұрын
I agree it would be nice to have a genset be able to run at low engine rpm and store the energy needed in capacitors then boost to start the load like a mini soft start installed in the gen. And yea when temps get higher power of the gens start to drop.
@CoryTaylor904
@CoryTaylor904 11 ай бұрын
Be aware, genmax hos refused to provide me a pinout or instructions on how the ats port works. The wiring diagram is included, but no details on how to use the ats port at all.
@johnnysweekends
@johnnysweekends 11 ай бұрын
That’s probably because they don’t want to give away info on how it works for others. It’s for them and there own transfer switch. Which they are finishing up. If no one else has one on a portable unit. I don’t think I would give info on how it works either. When you buy the transfer switch you use there own. Kinda like a generac I don’t think they will give you all the info as well. You use the generac transfer switch
@CoryTaylor904
@CoryTaylor904 11 ай бұрын
@@johnnysweekends true, but it seems misleading to say o product supports ats, but not have one for sale yet. Also, Westinghouse has portable units with the exact same ats plug & wiring diagram. I will be designing a conversation box to allow this generator to work with any two wire start ats, if anyone is interested.
@aksentyalagoz6061
@aksentyalagoz6061 6 ай бұрын
is it CSA approved
@johnnysweekends
@johnnysweekends 6 ай бұрын
I will have to double check but I dont think I see many generators even Honda have a CSA sticker.
@LuckyChow
@LuckyChow 11 ай бұрын
Johnny I still can't get the code to work. Thx
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea they where off for the weekend to revise the code so I should have it fixed this evening 🤞🏼🤞🏼
@LuckyChow
@LuckyChow 11 ай бұрын
@@johnnysweekends Tried the new code. It is not working right now either.
@johnnysweekends
@johnnysweekends 11 ай бұрын
I know they messed up again, I’m so sorry for this. They are going to bump the discount higher for the mistake. Tomorrow morning or this evening I’ll have the new code. Thanks for your patience and understanding
@johnnysweekends
@johnnysweekends 11 ай бұрын
New code amzn.to/3Yu0DEL Code: 050809new
@LuckyChow
@LuckyChow 11 ай бұрын
@@johnnysweekends Thank you! I just ordered it and saved $145!
@SuperLeonardo40
@SuperLeonardo40 4 ай бұрын
Science needs to invent those generators that make no noise at all and that we can use the sun as energy, and then spend day and night without need of electricity.Maybe in 100 years?.Little less?.
@johnnysweekends
@johnnysweekends 4 ай бұрын
Have you seen the solar generators or power stations we typically call them? They are getting so much better!!
@tmanning4usa
@tmanning4usa Ай бұрын
I think that genmax has discontinued this generator it isn't listed anymore it must have been junk with a bunch of issues so they got rid of it.
@johnnysweekends
@johnnysweekends Ай бұрын
Just out of stock. Many are happy with it from info gathered..🤷🏼‍♂️ plus the new EFI tri fuel is due anytime 👍🏼
@Legendary_UA
@Legendary_UA 11 ай бұрын
What is the approximate decibel output? Nevermind... I just hit the segment in the video
@MrPatdeeee
@MrPatdeeee 11 ай бұрын
But no showing of Natural Gas. And I see these Tri-Fuel generators all the time; but they NEVER use NG. What's going? Huh? So sad.
@johnnysweekends
@johnnysweekends 11 ай бұрын
The problem with natural gas is you won’t see good performance. You’ll see diminished numbers and people will think it’s a weak unit. But that would be with any generator running on NG. A 20% cut in power is a decent chunk and if it’s really hot it could be 30% or more, as heat will rob power with any fuel source. NG has way less btu and you’ll use 6 times the amount to generator the same power a gallon of gas will. Now this could work out if NG costs in your area are super cheap, and you don’t need that extra power. Running a generator at 80% and above it’s rated load all the time will decrease it’s life so you should upgrade to a larger unit if you are in that range.
@Egleu1
@Egleu1 11 ай бұрын
@@johnnysweekends To me the benefit of natural gas is you never have to worry about running out of fuel, unless the gas lines to your house are shut off. Great testing, thanks for the vid.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Yea that is a nice thing, because most times your NG is on, unless its a disaster zone. And thank you, plus your welcome
@MrPatdeeee
@MrPatdeeee 11 ай бұрын
@@johnnysweekends No disrespect, but most of the Generator Companies now; are adding the NG feature also. Making it a "Tri-Fuel" Generator. Thus, I can't think the Company; would NOT put a big note; saying similar words of what you said. Secondly, I have had NG in my home for 48 yrs. Plus, I have several things that use NG...and we never had ANY problem. So why would it cause problems with the Generator? Again "NO" disrespect.
@johnnysweekends
@johnnysweekends 11 ай бұрын
NG doesn’t cause “problems” with generators. It’s mainly two things using NG. Overall power output is less and engine life for generators is less on NG. It has less lubricants so engines wear a little faster. So if a NG gets 5000 hrs Propane 7500 hours Gasoline 10000 hours Diesel 15-20k hours But the having NG readily available is the convenience of a tri fuel setup. It’s ready you plug in and go if you are set up for. Trust me I like it as well. I’m also ready to run what ever fuel source I need. Normally I use propane or if I have enough gas I’ll use that up so it’s not sitting much. Which it’s just for my lawn equipment now that is almost all battery powered now.
@SofiaisSunshine
@SofiaisSunshine 2 ай бұрын
Discontinued… its why i tend to stay away from these super china fly by night companies
@johnnysweekends
@johnnysweekends 2 ай бұрын
Not discontinued, probably out of stock, and the new EFI tri fuel model is coming Plus you can still get the pulsar 10500 🤷🏼‍♂️
@shanew7361
@shanew7361 11 ай бұрын
No fuel injection ill pass.
@johnnysweekends
@johnnysweekends 11 ай бұрын
Some are coming but months away
@daithi007
@daithi007 11 ай бұрын
It might be more reliable.
@johnnysweekends
@johnnysweekends 11 ай бұрын
True
@mwahlert
@mwahlert 11 ай бұрын
Pros and cons to FI. IIRC, you can’t pull start an EU7000is for that reason.
@CoryTaylor904
@CoryTaylor904 11 ай бұрын
@@mwahlert I can pull start my Honda eu7000
@dustup2249
@dustup2249 3 ай бұрын
Underpowered toy. Need a LP generator that outputs a minimum of 12,000 running watts & outputs split phase 120/240VAC and 20,000 watt surge. Gasoline evaporates, turns rancid, is stored in containers that are susceptible to puncture or spill and is illegal to stor in bulk in most states without specialized containment and recovery systems, while LP stores in all weather in non puncturing containment that fuel levels can be monitored using ultrasound, pressure gauges and/or internal float and never goes rancid, stale or inert and most importantly, can be bulk delivered and stored on site.
@catastrophicfella
@catastrophicfella 12 күн бұрын
No? Running my entire home including 2.5ton central air, gaming PC, LED tv, dishwasher, deep freeze, fridge and a floor fan - only using 3100 running watts. Get a soft start for your central air and manage your use - this is plenty to keep a household going. I'm actually running the GM9000ied so even lower running wattage.
@dustup2249
@dustup2249 12 күн бұрын
@@catastrophicfella Good one. I've heard that before. Sooner or later they all syncchronize to start at the same time.
@howtodoitdude1662
@howtodoitdude1662 6 ай бұрын
After seeing the price, I stopped watching.
@johnnysweekends
@johnnysweekends 6 ай бұрын
It’s an actually not a bad price for an inverter this size…but this is also another good option…amzn.to/3vz63nI
@fred8565
@fred8565 10 ай бұрын
in the age of trying to go green, this is useless
@johnnysweekends
@johnnysweekends 10 ай бұрын
Lol absolutely wrong.
@johnnysweekends
@johnnysweekends 11 ай бұрын
DISCOUNT CODE BELOW……..The New Genmax 10500ietc is a great choice for home back up power, construction, or food trucks! #generator #inverter #grid #foodtruck #backuppower ITEMS IN VIDEO……… Discount code only good from 8-2-2023 - 10-2-2023 USE CODE: EURQEDFE At check out..👍🏼 Genmax 10500iETC: amzn.to/3rPSjmB Power Watch dog: amzn.to/3DC3H8a Direct Questions for fast response ...asqme.com/@johnnysweekends CHECK OUT MY AMAZON STORE: www.amazon.com/shop/johnnysweekends If you feel I helped you out..Buy me a Coffee 👍🏼🙌🏼👊🏼😀 www.buymeacoffee.com/johnny5120J
Genmax GM10500iETC Paralleled
6:46
Gavin’s Garage
Рет қаралды 20 М.
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 12 МЛН
HOW DID HE WIN? 😱
00:33
Topper Guild
Рет қаралды 49 МЛН
Slow motion boy #shorts by Tsuriki Show
00:14
Tsuriki Show
Рет қаралды 4,7 МЛН
Русалка
01:00
История одного вокалиста
Рет қаралды 7 МЛН
I Bought a Military Surplus Diesel Generator to Power my House
35:24
Waldo's World
Рет қаралды 4,3 МЛН
This Generator Quiet Box has a SECRET!
7:42
SoundBlab
Рет қаралды 53 М.
BEST Costco GENERATOR Two Years Later
9:52
TOOLMAN TIM'S WORKSHOP
Рет қаралды 73 М.
Cheap vs. Expensive Generator (Surprising Results)
25:49
Ambition Strikes
Рет қаралды 562 М.
Best RV Generator Option! Parallel Generators Vs Large Generator.
11:06
Hidden Inventions That Will Take Your Home to Another Level
20:22
WHAT’S THAT?
00:27
Natan por Aí
Рет қаралды 12 МЛН