Blower Door Test

  Рет қаралды 89,973

Matt Risinger

Matt Risinger

8 жыл бұрын

Huge thanks to our sponsors Marvin Windows, DAP, Cosella-Dörken, and Sugatsune for helping to make these videos possible!
For more information on their products visit them in the links below:
www.Marvin.com
www.DAP.com
www.Cosella-Dorken.com
www.Sugatsune.com

Пікірлер: 46
@ericklodnicki
@ericklodnicki 8 жыл бұрын
Congrats Matt. Maybe you can do a follow up video that highlights the key considerations that help you dial into a best outcome on the blower test (Windows, sheathing seals, etc - things I know you cover individually in many videos), but also the areas that often might be less under your control that contribute negatively to the outcome?
@boilermech2294
@boilermech2294 8 жыл бұрын
thanks for all the informative videos, they help a lot . was this house common construction type or a super insulated home? do you find better results (iaq) with different sip manufactures?
@Johnintoit
@Johnintoit 8 жыл бұрын
Matt, are you doing more then one door blower test on your homes, say one before insulation/drywall and one on completion? Would be pretty hard to seal any air leaks that may be happening behind finished work, just wondering.
@ze_german2921
@ze_german2921 6 жыл бұрын
So if you don't live in Austin, Seatle, LA or NY who can you hire to perform this test?
@ecoevo
@ecoevo 6 жыл бұрын
Matt, what is the permeability rate of this home? CFM/m2@50Pa. Better yet m3/h@50Pa for us Australian’s. 😉
@michaelcarton3299
@michaelcarton3299 4 жыл бұрын
How do all the bath vents and kitchen hoods affect testing? I have high quality Panasonic vents throughout my bathrooms and a 1300CFM kitchen hood. My make-up air unit brings in heated air to match the hood venting. The dampers on these devices are very flimsy and do not positively seal. In fact, I have NEVER seen or heard of a bath/kitchen vent where the damper actually sealed. They more or less just get in the way and leave a clearance all around so the flap can freely move. Do you seal all these up prior to testing>?
@bulmarogomez1284
@bulmarogomez1284 5 жыл бұрын
Hey Matt could you give me an average estimate cost of doing a blower door test. i live in fort worth and have been looking into this but dont know what an estimated cost would be. i have a home built in the 1920s and would love to seal it up and this is the only thing that makes sense investing in. thanks
@AlvaStrong
@AlvaStrong 5 жыл бұрын
Don't you need to add mechanical ventilation if the ACH 50 is less than 3?
@Brandon-no3vc
@Brandon-no3vc 2 жыл бұрын
What if the house has mold or something won't you disturb it with the blower door test and send spores or whatever thro the house causing problems?
@Upliftyourbrothers
@Upliftyourbrothers 8 жыл бұрын
Do you seal up the vents for combustion air when this is done? Thanks.
@matthewharaminac6348
@matthewharaminac6348 6 жыл бұрын
I'm pretty sure that house would have been built with sealed combustion appliances.
@Fredflinstone23
@Fredflinstone23 3 жыл бұрын
How this work if you have exhaust fan in bathroom? exhaust in rangehood
@hotdog5966
@hotdog5966 2 жыл бұрын
Matt, Do you know of any good builders in Citrus County Florida ?
@JoeLarge
@JoeLarge 8 жыл бұрын
How did he get cu ft of the home? from prints etc.? So do you do a trial run before he shows up...? Nice work.,
@bryonweatherford1772
@bryonweatherford1772 6 жыл бұрын
How do you get the cu ft of anything. Length x width x ceiling height. 30x50x8=12,000 cu ft. So heat loss from the infiltration of air into your house equals the volume of the house x the design temperature x ACH(per hour) x .018. .018 is the heat capacity of air at sea level in Btu per cu ft per degree F. So in Austin Matt states he must be at 5 ACH. This would equate to 54,000 Btu's lost per hour at a design temp of 50* F. At Matt's ACH of 1.9 it is 20,520 Btu's per hour. Consequentially, if he could hit the Passive House standard of .6 ACH it would be 6480 Btu's per hour. 3412 Btu's is the equivalent of 1 Kw/h of electricity. So a code house would need 15kW of heat a tight house need 2kW and that's just from air infiltration.
@krisraps
@krisraps Ай бұрын
I Think Its Really Cool To Be A Milionaire, Sweet. I Wish IWill Be One Someday
@BitsOfInterest
@BitsOfInterest 3 жыл бұрын
Hi, I'm from the future and you just built your own house at 0.1 ACH50 after using Aerobarier. Oh how far we've come in just a few years 😁👍
@njsification
@njsification 8 жыл бұрын
Wouldn't this test make more sense if it used external area rather than volume? If you double the size of a house, the total external exposed area doesn't increase at nearly the same rate.
@John28530
@John28530 6 жыл бұрын
I know this was a year ago but your using internal volume as because your of the units internal volume (cubic ft)/ air flow (cubic feet per hour) Cubic feet cancles and your left with Air changes per hour.
@ecoevo
@ecoevo 6 жыл бұрын
Volume(ach@50pa) is just easier to explain to the masses. People that don’t quite understand this stuff. A permeability rate is a much more accurate way of understanding air tightness though, especially, if you want to compare apples with apples. Bigger homes score a lower ach@50pa, without a doubt.
@user-qv2vv6jj1i
@user-qv2vv6jj1i 6 ай бұрын
QuickTrain Canada microcredits course from Holland College brought me here.
@jeffsprott-redoakceo4514
@jeffsprott-redoakceo4514 3 жыл бұрын
Wow so awkward with the stare at the end. Nice video as always my man.
@tomdowler5416
@tomdowler5416 3 жыл бұрын
Wait, you depressurize *to* 50 pascals? Or *by* 50 Pa?
@SystemHacker23
@SystemHacker23 3 жыл бұрын
Yeah that didn't make sense to me😅
@liammcgarrigle
@liammcgarrigle Жыл бұрын
by 50. They zero the system out first then depressurize till it's -50
@truqualitypaintingtv7814
@truqualitypaintingtv7814 2 жыл бұрын
Great video. Side note I couldn’t be that close to someone while talking to them it was actually mildly distracting. Lol
@pouyazadutube
@pouyazadutube 4 жыл бұрын
Hello, do I have your permission to use this video in my building systems class?
@spencerd1079
@spencerd1079 2 жыл бұрын
No
@robertward1728
@robertward1728 7 ай бұрын
Interesting
@whatthefunction9140
@whatthefunction9140 8 жыл бұрын
kind of awkward that the other guy never looks at the camera.
@9avedon
@9avedon 5 жыл бұрын
Hey Snowflake, He is paying attention to Matt , not doing a selfie.
@townsendliving9750
@townsendliving9750 5 жыл бұрын
Its nice how he stares into Matt's eyes deeply tho
@pegefounder
@pegefounder 3 жыл бұрын
Use SI units instead of this phantasy measurement units from Lord of the rings.
@arthurmorgan7642
@arthurmorgan7642 3 жыл бұрын
Dont open the other door of the house could that thing will go crazy🤣
@kittybok
@kittybok 6 жыл бұрын
His voice is sick. I wonder what his original real voice sounds like
@Killovision1
@Killovision1 7 жыл бұрын
Enjoy the mold.
@subjectmatteramateur16
@subjectmatteramateur16 6 жыл бұрын
Eric Jennings there is this new thing called ventilation.
@bryonweatherford1772
@bryonweatherford1772 6 жыл бұрын
Which is what leaky houses had???
@subjectmatteramateur16
@subjectmatteramateur16 6 жыл бұрын
bryon weatherford so you are saying we should leave all of our doors and windows open? That would be the same as having a "leaky home". The idea is to allow the hvac to dehumidify and the bathroom and kitchen vents to evacuate high levels of humidity then we don't have to heat the world with a "leaky house".
@bryonweatherford1772
@bryonweatherford1772 6 жыл бұрын
I was implying anything. I agree that house needs to be tight. But just making it tight is half the battle.
@casualbillionaire
@casualbillionaire 3 жыл бұрын
I had a very leaky house...open vents in crawl, no insulation in crawl, zero insulation between crawl and floors above it and zero insulation between crawl and habitable space next to it. Guess what, still had mold and odor. Sealed up the vents, added perimeter insulation all the way around the crawl...odor went away.
@robertward1728
@robertward1728 7 ай бұрын
Interesting
How To Run A Blower Door Test
36:56
Retrotec
Рет қаралды 20 М.
КАК ДУМАЕТЕ КТО ВЫЙГРАЕТ😂
00:29
МЯТНАЯ ФАНТА
Рет қаралды 9 МЛН
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 166 МЛН
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 78 МЛН
Secrets to Airtight Homes: Blower Door Test with Fog in Action
16:12
Minneapolis Blower Door Quick Guide
7:20
The Energy Conservatory
Рет қаралды 8 М.
PASS or FAIL? New Construction Blower Door Test Inspection
4:13
Home Comfort Guy
Рет қаралды 587
HELUZ - Blower Door Test
8:31
Koordinuj.cz
Рет қаралды 898
Duct Leakage Testing
5:12
Tec Tube
Рет қаралды 43 М.
Blower Door Basics: Part II - The Test Process
14:38
TheWXTV
Рет қаралды 61 М.
Der SIGA Blower-Door-Test
7:54
SIGA Deutsch
Рет қаралды 83 М.
Why is sealing important for radon mitigation?
9:42
American Radon Mitigation
Рет қаралды 16 М.
Beyond Blower Doors: Zonal Pressure Testing
13:38
Home Performance
Рет қаралды 17 М.
Blower Door Quick Guide Part 2
10:52
The Energy Conservatory
Рет қаралды 34 М.
КАК ДУМАЕТЕ КТО ВЫЙГРАЕТ😂
00:29
МЯТНАЯ ФАНТА
Рет қаралды 9 МЛН