No video

COMBI BOILER,TEMPERATURE SENSOR TEST,THERMISTOR TEST

  Рет қаралды 135,298

TippTopp81

TippTopp81

Күн бұрын

This video is how to test combination boiler temperature sensors.
Any video request please comment and I'll try my best.
Please Like and comment

Пікірлер: 45
@saedsorean378
@saedsorean378 4 сағат бұрын
Thanks a lot , the explanation is perfect,
@kombiteknikservisi
@kombiteknikservisi 8 жыл бұрын
Kombi sensör arızasını anlaya bilmek için açıklayacı video. Ustaya teşekkür etmek lazım.
@TheDickPuller
@TheDickPuller 11 жыл бұрын
Great video mate, please do more on components testing it's always good viewing.
@BADMANDONS21
@BADMANDONS21 9 жыл бұрын
Great video, clear explanation. I have central heating working fine but no hot water. I have been informed that DHW Thermistor could be an issue as boiler does not know of problem. Thanks I will try your video explaination. Jay
@acrestones
@acrestones 10 жыл бұрын
Hi really really like your video well explained really appreciated to you for share your knowledge with us Kindly please can you upload more videos like how to check boiler fan & air pressure switch & more like boiler fault finding & Diogenes Thanks a lot
@woodbine66
@woodbine66 11 жыл бұрын
Yes, .more component testing vids please. Pumps, valves, boiler internals. Many thanks.
@foxyhlc
@foxyhlc 10 жыл бұрын
Good job and thanks for giving this information.
@loghead8615
@loghead8615 10 жыл бұрын
A thermister can go open circuit when resistance increases/decreases so dont take it for gospel they are ok... (Had a few thats done it)
@Taqqiyastar
@Taqqiyastar 11 жыл бұрын
Excellent video well explained about thermistors Please upload more video about boilers such as diverter valve/diaphragm etc. Thanks
@Eatherz
@Eatherz 11 жыл бұрын
EXCELLENT VIDEO , as i was looking for a new meter after getting some funny readings off my tpi ez100 ..
@acidtechno
@acidtechno 6 жыл бұрын
great vid , replaced 3 of these in one year .. how come they keeping going wrong? never had to change one in 10 years and now three in less than a year ??
@TippTopp81
@TippTopp81 11 жыл бұрын
I'll try to do a clip on air pressure switches in the next few days.
@redrock1963
@redrock1963 4 жыл бұрын
I believe when you tested the second thermistor the lead tips were touching and that's why you got the O.L reading....then when you moved you got a correct reading. You remind me of tradies I've hired here and cost me more $$$ then needed.
@TW-mp8zx
@TW-mp8zx 4 жыл бұрын
redrock1963 im just comparing these readings he got the first one was correct for room temperature, and the second one of 9000 is showing a temperature of around 27 Celsius.. I wouldn’t say that’s too problematic if anything the boiler might cycle on and off at lower deltaT room temps..
@martinb6079
@martinb6079 3 жыл бұрын
If the lead tips were touching you wouldn't get a O.L reading (basic electronics testing). You would get 0.1- 0.9 ohms like he showed earlier in the video.
@neilcarroll4579
@neilcarroll4579 4 жыл бұрын
Just a quick question please , my heating hasn't been on all summer (turned to dhw only ) , however water has been hot as normal , pressure is fine , however water often goes cold , from these videos it sounds like the temp sensor , however pilot light goes out , would pilot light go out if bad hot water sensor and dhw on only ? Thanks
@AnthonyFrancisJones
@AnthonyFrancisJones 2 жыл бұрын
I may be missing something here but the 10k and second one at 9k are almost the same resistance so both registering around room temp. 80 degrees C would be about 4k - I am not a heating engineer so what am I missing here??
@TippTopp81
@TippTopp81 11 жыл бұрын
KaneInternational do a great set of clips on Flue Gas Analyses on youtube. But when i get a chance to do a vid on site i'll do one.
@richiefinn
@richiefinn 4 жыл бұрын
Does it matter which wires go on which terminal mine are independent, not in a block thanks
@yusufrehman2157
@yusufrehman2157 5 жыл бұрын
Please make live and dead test of each component of boiler
@ianwilliams4787
@ianwilliams4787 5 жыл бұрын
Would this explain why the hot tap runs hot then cool ?
@DavidSmith-cz9zv
@DavidSmith-cz9zv 5 жыл бұрын
If I unscrew this from my boiler will water come out. Or is it sealed in a pocket
@asengsaputra288
@asengsaputra288 Жыл бұрын
Hello sir l have sensor boiler temperature, 3 wire cable color : Red,blue and white but l dont now type of sensor RTD or Thermocoule . Please help me sir Thank you…
@MrSTUPIDBRICK
@MrSTUPIDBRICK 11 жыл бұрын
any chance of a tutorial on flue gas analysers please
@leonagraca2239
@leonagraca2239 5 жыл бұрын
Ok so we don't have a fluug so what do we do guess what ohms it is to be set?
@possle
@possle 11 жыл бұрын
Is the for all thermistors or do different ones have different ohms ratings.
@loghead8615
@loghead8615 10 жыл бұрын
Very well explained tho
@OreecleTV
@OreecleTV 11 жыл бұрын
well explained thanks.
@BarbellMonkey
@BarbellMonkey 6 жыл бұрын
Hi, when removing these sensors.. Do you need to drain the boiler or anything like that? Will water be behind the sensor?
@TippTopp81
@TippTopp81 6 жыл бұрын
MonkeyPumpkin some are dry pocket but I'd drain it to be sure.
@BarbellMonkey
@BarbellMonkey 6 жыл бұрын
TippTopp81 thank you very much for the reply!! :)
@markzola8142
@markzola8142 6 жыл бұрын
Hi,my boiler keeps shutting down when i run a bath,could it be a faulty thermister?
@knapman1990
@knapman1990 5 жыл бұрын
Blocked plate heat exchanger 👍
@wilburcartwright5068
@wilburcartwright5068 7 жыл бұрын
11.000 to 13.000 oms is when the boilers cold what should it read when boilers running???
@leaturk11
@leaturk11 6 жыл бұрын
These work by decreasing the resistance proportionally with an increase in temperature, for example 25 degress C to start at 12,000 Ohms, to 55 degrees C at 4,000 Ohms. As temperature goes up, resistance comes down.
@taab7
@taab7 6 жыл бұрын
Where do you put the probes on a single pin sensor?
@anthonycosta2613
@anthonycosta2613 6 жыл бұрын
taab7 one side on the pin the other side to earth
@ArksE8
@ArksE8 9 жыл бұрын
Only if the thermistor is an NTC.
@KarateCritic
@KarateCritic 5 жыл бұрын
Yes. No mention of NTC vs PTC thermistors. Otherwise good info. Cheers!
@TheTomplum
@TheTomplum 11 жыл бұрын
tipptopp, you sound like a Wiganer, are you? good vid BTW
@TippTopp81
@TippTopp81 11 жыл бұрын
I'll try to do a clip on air pressure switches in the next few days.
@umark6695
@umark6695 7 жыл бұрын
TippTopp81 Nice video. We're still waiting for the new video ;)
No Hot water or Heating: Multi-meter fault finding Part 1
18:16
WoW! Warriors of Warmth Plumbing Happy to help
Рет қаралды 63 М.
Faulty ntc sensor thermistor
4:59
The Mental Gas man
Рет қаралды 2,1 М.
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН
How I Did The SELF BENDING Spoon 😱🥄 #shorts
00:19
Wian
Рет қаралды 37 МЛН
Get 10 Mega Boxes OR 60 Starr Drops!!
01:39
Brawl Stars
Рет қаралды 19 МЛН
Dad Makes Daughter Clean Up Spilled Chips #shorts
00:16
Fabiosa Stories
Рет қаралды 2,8 МЛН
All electronic components names, functions, testing, pictures and symbols - smd components
24:09
Live Fault Finding #12 - Faulty Baxi Diverter Cartridge
16:11
CP Utility Solutions
Рет қаралды 18 М.
Why Does My Boiler Keep Losing Pressure?
36:37
Skill Builder
Рет қаралды 394 М.
Gas Training - Boiler Fault Finding - No Hot Water - Roy Fugler
23:43
No hot water or Heating: Part 2 boiler components
14:40
WoW! Warriors of Warmth Plumbing Happy to help
Рет қаралды 23 М.
How To Check IGBT Transistor (Tagalog) PRO TECH Electronics
6:05
PRO TECH Electronics
Рет қаралды 107 М.
Different types of thermistors, locations and how to remove them from a boiler
5:47
Baxi - sustainable heating and hot water solutions
Рет қаралды 17 М.
Prank vs Prank #shorts
00:28
Mr DegrEE
Рет қаралды 10 МЛН