Troubleshooting and repairing intermittent problem with Liberty LCU-20S Condensate Pump connected to our central air evaporator. Pump would run dry for hours at a time.
Пікірлер: 2
@borisdavila6998 Жыл бұрын
So you changed the positions of the switches ? And added the long metal lever to it??
@damnedhumanrace Жыл бұрын
I didn't change the position of the switches. The rear switch I assume was originally intended to be a safety backup? But it was not connected to anything, so after confirming it was in working order I transferred the connectors from the failed switch to the one that was not being used. The triggering mechanism is slightly different on the rear switch, as there is no lever - it relies on the float pressing directly down on the button. So far so good