Cooling Tower Overflowing Follow Up Work Order | I Should’ve Check This

  Рет қаралды 35,132

Subcool HVAC

Subcool HVAC

Күн бұрын

Going back to figure out cooling tower 1 water overflowing during shutdown #hvac #coolingtower #chiller

Пікірлер: 58
@yinggamer7762
@yinggamer7762 4 ай бұрын
First time seeing the inside of a water tower chiller, looks and sounds so cool 😮
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Evapco Towers are 👍 Thanks for Watching!
@laquavious4612
@laquavious4612 4 ай бұрын
You should see a protech those are not so cool 😂
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Lol, we used to have plenty . Good times , especially the itching after working on them.
@laquavious4612
@laquavious4612 4 ай бұрын
Also the condenser fans aren’t to fun
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
True
@jasonjohnsonHVAC
@jasonjohnsonHVAC 4 ай бұрын
The piping and the way its ran seems to always be an afterthought. I constantly run into poor piping practices...the building im on is a prime example....we do what we can....but dang....it can be a pain sometimes. Great video as always
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
There were some old wooden Marley towers there before, they just kept adding pipe to retrofit 😃 Thanks Jason 👊
@jasonjohnsonHVAC
@jasonjohnsonHVAC 4 ай бұрын
@@subcoolHVAC well of course they did. 😆
@australianfridgie4469
@australianfridgie4469 4 ай бұрын
u could put a 90degree elbow facing up on the upper overflow to save that water and chemicals. cut ur pipe going upwards to set water level when pumps off so its not pouring down the drain and then doesn’t have to fill every time pump starts
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for the idea 👍
@berknofear8833
@berknofear8833 4 ай бұрын
Man that was smart to change the ABB VFD ramp up rather then change the float! I bet that balanced out the system after that! Chillers wit cooling towers is the best commercial setup for cooling.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for watching 👍
@Thermoelectric7
@Thermoelectric7 4 ай бұрын
Looks like all that water is just from the supply line to the tower draining out. Realistically it should have been run lower and then step up right at the tower, rather than horizontal straight out of the tower. If you want to fix it, you could modify the pipework feeding the top of the tower and install an inverted P trap (P going up not down) just prior to where it enters the tower. That'll stop the water draining out of the entire supply line, only what's left after the trap. Probably not cost effective for the little bit of water it'll save, though.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
That makes sense , don’t think they will make the change though. Thanks for your comments 👍
@Ericbakereb1
@Ericbakereb1 4 ай бұрын
Had an interview at Trane today for in house chiller tear downs. Man I hope I land that. 😅
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
That’s awesome, hope it works out for you 👍
@darrend1068
@darrend1068 4 ай бұрын
Bay Area?
@user-sm3pt1lt2y
@user-sm3pt1lt2y 4 ай бұрын
In tyler?
@zekenzy6486
@zekenzy6486 4 ай бұрын
Great Video as always. Thank you for sharing. What 's kind of water for use cooling tower ? fresh water , tap water or water mix with chemical ?
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Chemically treated tap water, Thanks
@Bobherry
@Bobherry 4 ай бұрын
I work at a hospital in house and we have 8 cooling towers we work on. 2 are side by side and 1 always runs its amazing being inside the one beside it while the other is running. 4 Evapco and the rest are a different brand.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Good stuff, Thanks for commenting 👍
@brauchmernet
@brauchmernet 4 ай бұрын
Hm, maybe the falling water influence the float (until the fan starts) more then normal. I have changed makeup water valves before because of this. Mostly bigger floats to counteract the water from above
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
The float rod is closer to parallel at full than before now 👍
@mrchew1982
@mrchew1982 4 ай бұрын
Your float should have a nut on both sides to keep it from working it's way out. Those windage screens look plugged up too, should pressure wash those bad boys... Better airflow may cure that noise that you're hearing.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for watching!
@IanGSully
@IanGSully 4 ай бұрын
Good place to go swimming 😉
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
😃 almost big enough
@paulpipitone8357
@paulpipitone8357 4 ай бұрын
I still dont know why they use butterfly valves as circuit setters? i would recommend a plug valve and set it up and use the butterfly as a shutoff only just my two cents
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for watching 👍👊
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
I appreciate it 👍
@Nikolay244
@Nikolay244 4 ай бұрын
1-st reason of overflowing during shut down: drain pump is stopped, but water inside of cooling elements still coming; 2-nd reason: drain system is dirty and don't allow to suck a lot of water; 3-d reason: drain valve is closed about 50%
@subcoolHVAC
@subcoolHVAC 3 ай бұрын
Thanks for watching!
@CoronaVijvertechniek
@CoronaVijvertechniek 4 ай бұрын
2:59 next time first wait until overflow stops then turn on the pump and then adjust the fill float otherwise the tank will still overflow
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Unfortunately for now it has to be where it is due to the pipe distance otherwise cavitation starts, its far from a perfect setup . Thanks for watching 👍
@leexgx
@leexgx 4 ай бұрын
Does the suction pipe which I assume is that big pipe that’s on the right of the evaporator tank not have a downward angled pipe connector so it sucks from the bottom of the tank (if it is just simply that hole in the side of the tank it’s going end up sucking air)
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
It has an anti-vortexing hood inside leading to the bottom of basin
@ralphgiampietro85
@ralphgiampietro85 4 ай бұрын
Seems like that tower could have neeed an auxiliary sump to contain the overflow as with most tower jobs that I've seen but this is not my area of expertise
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
🤔 a possibility, Thanks for the comment 👍
@gregkaslow4419
@gregkaslow4419 4 ай бұрын
Motor control group 26. Code 2606 SWITCHING FREQ increase it from default 4khz to 8khz this will quite down the motor.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Would that increase of temp at the drive be significant from 4 to 8 HZ?
@gregkaslow4419
@gregkaslow4419 4 ай бұрын
My ABB rep suggested this to me a few years ago when I had a noisy motor. But he advised not to set it past 8khz.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
I gave it a try, nothing noticeable. Left it at 4khz. Thanks for sharing
@slipstreamvids7422
@slipstreamvids7422 4 ай бұрын
Surprised the system runs so high in the sump that normal stop start operation requires water loss out the overflow.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for the comment 👍
@wilymcgee
@wilymcgee 4 ай бұрын
is it really that quiet in the plant...??? no way man.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
I quiet some of the background noise during edit but for screws it’s not as loud as others . Thanks for asking
@wilymcgee
@wilymcgee 4 ай бұрын
@@subcoolHVAC ah ok, i've been in plants having to yell at the chap next to me.. ~consulting engineer
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
I have a York screw plant like that 👍
@johnvira1529
@johnvira1529 3 ай бұрын
Lower the water level..seems like a lot.
@subcoolHVAC
@subcoolHVAC 3 ай бұрын
Thanks for watching
@Exile1213
@Exile1213 4 ай бұрын
What a waste of water out of that overflow. Chemical guy hates you I bet… sump level didn’t seem to drop a ton on startup, can you get the fill level down lower without cavitation? Keep water from going out that overflow.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
Thanks for watching!
@etchcamelia108
@etchcamelia108 4 ай бұрын
That honeycomb filter media has seen better days.... I bet there's plenty of problems at this site. Nice work on your part to fix the challenge and adjust the ABB Freq-Drive.
@subcoolHVAC
@subcoolHVAC 4 ай бұрын
It’s due for annual cleaning, other than this issue not many problems… Thanks for commenting!
Cooling Tower PM Basic's HVAC Training for HVAC Technician
34:57
Exploring a 1 MILLION Watt FM Tower
18:30
Geerling Engineering
Рет қаралды 778 М.
Underwater Challenge 😱
00:37
Topper Guild
Рет қаралды 41 МЛН
白天使选错惹黑天使生气。#天使 #小丑女
00:31
天使夫妇
Рет қаралды 15 МЛН
Personal "air conditioners" aren't what they seem
27:03
Technology Connections
Рет қаралды 2,5 МЛН
How a Supermarket Refrigeration System Works
8:45
HVACR Career Connect NY
Рет қаралды 61 М.
CARRIER EcoBlue PACKAGE UNIT INSTALL
33:22
HVACR VIDEOS
Рет қаралды 31 М.
Cooling Tower Setpoint For Chiller
19:24
HVACTIME
Рет қаралды 36 М.