No video

Copeland Hermetic Liquid injection Valve replacement

  Рет қаралды 9,175

D.R.C. Productions

D.R.C. Productions

Күн бұрын

Пікірлер: 21
@drlfter
@drlfter 3 жыл бұрын
Fantastic video and I appreciate that you took the valve apart and thoroughly explained how it works. People like you are a godsend for others just getting started in refrigeration or someone with a curious itch. I've subscribed and will be watching more of your videos. Thank you and keep up the great work sir!
@axiomteck
@axiomteck 3 жыл бұрын
the best HVAC and refrigeration videos, nice that you explain all the details of each component's great work. looking forward to seeing more and more
@jrh86
@jrh86 Жыл бұрын
Excellent diagnostics and very interesting part functionality and failure tutorial 👍👍👍
@Mgear1217
@Mgear1217 3 жыл бұрын
Great video. Thanks for sharing.
@isaaccampos7276
@isaaccampos7276 3 жыл бұрын
Thank you for sharing
@u2ooberboober
@u2ooberboober 2 жыл бұрын
Great video!
@ebbyt00
@ebbyt00 3 жыл бұрын
Thanks for the video, I am wondering what was the symptom of the bad injection valve? how did you narrow it down?
@donalddperez
@donalddperez 3 жыл бұрын
Ebrahim Tirgardoun the compressor was overheated and fried. While the compressor was running, it was hot and the injection valve was not feeding. Put a thermocouple on the outlet of the valve and one on the top of the compressor. It’s supposed to open when it gets hot. Don’t know the exact specifications but you’ll see the valve temperature out drop when it feeds and cools the compressor. Simulate a hot compressor by covering part of the condenser. Thanks for the question 🤙
@RodrigoRamirez-fc5hv
@RodrigoRamirez-fc5hv 2 жыл бұрын
How do you check to see if it is working.
@shellopoy4398
@shellopoy4398 3 жыл бұрын
the 3/8" connection is connected to liquid line right?
@christianbudds2675
@christianbudds2675 2 жыл бұрын
At what temp did the valve begin to feed?
@mikemalone6103
@mikemalone6103 Жыл бұрын
How did you( test ) to determine the valve wasn’t functioning as designed?
@DRCProductions
@DRCProductions Жыл бұрын
Verify valve is opening and closing to valve set points. See chart and verify. If it is working the there is a different problem occurring. Put a thermocouple where the valve sensing bulb is located, It’s nice to have Bluetooth sensors so you can run graphs.
@mikemalone6103
@mikemalone6103 Жыл бұрын
I spoke with Copeland and they they said depending on my compressor, it can be the 193degree or 256degree ( I believe) it’s stamped on the side of the valve body… it does have a SOV upstream so that it only get liquid when the contactor is pulled in.
@mikemalone6103
@mikemalone6103 Жыл бұрын
And I felt another similar injection valve to it nearby on another unit, and it was sweaty cold keeping the dlt closed and the discharge line tolerable
@westsidehvac1097
@westsidehvac1097 3 жыл бұрын
How do you determine the valve is bad?
@DRCProductions
@DRCProductions 3 жыл бұрын
The compressor label on the top was brown from over heating. It was running but bypassing discharge gas internally. it was very hot and the valve was not feeding. Years of experience has taught me to use my free tools. Sight, smell, feel and hearing. Changed the compressor and valve then tested the valve which began to feed after I restated the compressor, when in doubt change it out.
@ericdvorak7030
@ericdvorak7030 2 жыл бұрын
Are these adjustable like a txv is?
@DRCProductions
@DRCProductions 2 жыл бұрын
No they are not adjustable. They come in different temperature ratings calculated by Copeland. 🤙
@ericdvorak7030
@ericdvorak7030 2 жыл бұрын
@@DRCProductions kind of what I thought, got one barley passing liquid with the compressor shutting down on internal temp, valve bulb probably leaked down. Thanks for the quick reply.
@DRCProductions
@DRCProductions 2 жыл бұрын
@@ericdvorak7030 When in doubt change it out.
Copeland Demand Cooling Troubleshooting
8:01
Refrigeration Confidential
Рет қаралды 11 М.
What is Common, Start and Run?
6:11
HVAC School
Рет қаралды 195 М.
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 4 МЛН
wow so cute 🥰
00:20
dednahype
Рет қаралды 31 МЛН
Yum 😋 cotton candy 🍭
00:18
Nadir Show
Рет қаралды 7 МЛН
АЗАРТНИК 4 |СЕЗОН 1 Серия
40:47
Inter Production
Рет қаралды 333 М.
Copeland Scroll™ Compressors for Refrigeration Applications
6:35
Refrigerant Service Valve Positions
1:20
HVAC Know It All
Рет қаралды 116 М.
Copeland Discus - Full Inspection & Teardown
18:34
Refrigeration Mentor
Рет қаралды 28 М.
Commercial Refrigeration Push Pull Liquid Recovery
3:22
Ron Walker
Рет қаралды 126 М.
Defrost termination / fan delay operation
5:56
CSC refrigeration and hvac
Рет қаралды 42 М.
Liquid Receiver Tank Purpose for Refrigeration!
4:22
AC Service Tech LLC
Рет қаралды 46 М.
Electronic Unit Controller - Getting Started
1:56
Copeland
Рет қаралды 60 М.
I Just Bought a Tesla and It Scares the Crap Out of Me
10:23
Scotty Kilmer
Рет қаралды 119 М.
How a Headmaster valve works
8:35
CSC refrigeration and hvac
Рет қаралды 32 М.
Advanced Refrigeration - Pump-down, Solenoids, and pressure switches
22:39
Christopher Molnar
Рет қаралды 19 М.
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 4 МЛН