Fire Alarm Devices

  Рет қаралды 14,350

Craig Michaud- Electrical Instructor

Craig Michaud- Electrical Instructor

Күн бұрын

In this video we explain how to install Fire Alarm devices.

Пікірлер: 28
@RicardoDelgado-zr4ki
@RicardoDelgado-zr4ki 3 ай бұрын
Very informative. Thanks for the info about this and your advice on how it works
@allanpita2221
@allanpita2221 2 ай бұрын
Dude the best explanation yet
@raycaballero6386
@raycaballero6386 Жыл бұрын
Your a very straight forward instructor that does a tremendous service in sharing your advanced skills and knowledge with your viewers. Thanks for what you do for us
@davidredpath4781
@davidredpath4781 3 жыл бұрын
Great video, Mr. Michaud! I have had to fix so many of devices installed incorrectly due to a lack of education or because people didn’t care. I really like how detailed you were and how you took the time to explain the wiring method and how to properly use a resistor at the EOL. Thank you for taking the time to make these videos. It helps a lot of people! I will definitely be passing this video along to others! Dave
@c4withit
@c4withit 6 жыл бұрын
It’s all about the addressable systems now Mr. M! Great video!!
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 6 жыл бұрын
Connor Madden I agree but this is just the first part. Next will be wiring a panel and then off to Addressable systems. Thanks for watching!!
@JPerez-ld6nb
@JPerez-ld6nb 2 жыл бұрын
It’s all about that smart system. Thanks for the video
@cuco176
@cuco176 11 ай бұрын
This video was great. Using this as a resource for knowledge. Thank you !
@achannelwithnopurpose1977
@achannelwithnopurpose1977 2 жыл бұрын
A thing I like to do when I wire is label everything. It makes going through lines and troubleshooting much easier as I don’t have to figure out what wire is for which connection/application
@hlhl5962
@hlhl5962 8 ай бұрын
very detailed and clear explanation
@virgilf3
@virgilf3 Жыл бұрын
Installing my first fire panel, thank you
@ronaldmedina2129
@ronaldmedina2129 6 ай бұрын
Very helpful information 👌
@4abettaworld
@4abettaworld 2 жыл бұрын
Thank you Sir, much appreciated
@brodiecollins4304
@brodiecollins4304 2 жыл бұрын
So clear and simple
@V21IC
@V21IC Жыл бұрын
This is a great 👍🏼
@elsiebonilla7445
@elsiebonilla7445 3 жыл бұрын
Thank you !
@manuelvalladares5004
@manuelvalladares5004 6 жыл бұрын
Nice
@FireAlarm33
@FireAlarm33 8 ай бұрын
Very cool!!!
@X410zee
@X410zee 2 жыл бұрын
My instructor taught me to put the resistor under each wire to get a good connection. The other positive I leave empty. Thought?
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 жыл бұрын
With some detectors that maybe the case. Not these!! If you don’t put the resistor on the open positive the zone loop is not supervised!! Meaning if something is wrong with the zone the panel won’t know. It’s important to have the panel show a trouble in the circuit in order for a proper installation! In 30 years I have seen a lot of different systems never once did I put the wire and resistor on the same side of the screw!! Hope that helped you!! CM
@malawigold747
@malawigold747 9 ай бұрын
Can I connect them without a resistor? Just black in negative and red in either positive?
@shielatalampas5544
@shielatalampas5544 2 жыл бұрын
do all fire alarm devices can run in 1 conduit?
@stephenhart6158
@stephenhart6158 2 жыл бұрын
why on the smoke detector and the notification device did you have one set of wires, on the pull station you had two?
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 жыл бұрын
This was a lab demonstration on device connections. CM
@stephenhart6158
@stephenhart6158 2 жыл бұрын
@@craigmichaud-electricalins4602 thanks Craig 12pm in Australia not sure what you mean by lab demonstration should there be one or two set of wires to the pull station. have you done a video on addressable panels? I know very little about fire panels and thought addressable panels had an inbuilt ability to locate individual devices. I didn't realise until recently that you have to install an addressable module to each device so that the FCP can locate it. It appears to me that each individual FCP manufacturer have their own specific modules just to suit their panels. Wouldn't it be smart for someone to have a universal one that would suit all panels. thanks for your info Steve
@craigmichaud-electricalins4602
@craigmichaud-electricalins4602 2 жыл бұрын
Yes absolutely but this is a conventional fire alarm system. I use these videos to show my students things they will learn in the lab. There are a lot of different situations on how to wire fire alarm. Looks like you are doing some good research!! CM
Fire Alarm Control Panel and Testing Devices
10:31
Craig Michaud- Electrical Instructor
Рет қаралды 11 М.
Fixing Fire alarm HVAC shutdown problem
36:49
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 6 М.
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Savage Vlogs
Рет қаралды 10 МЛН
Nastya and SeanDoesMagic
00:16
Nastya
Рет қаралды 40 МЛН
Jumping off balcony pulls her tooth! 🫣🦷
01:00
Justin Flom
Рет қаралды 26 МЛН
Addressable vs Conventional Alarm Systems
7:20
GPSTC Productions
Рет қаралды 40 М.
Why do they always fit the incorrect ones? PART 2
17:19
CJR ELECTRICAL
Рет қаралды 17 М.
Installing a fire alarm pull station on my home fire alarm system
20:04
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 7 М.
Fire Alarm Training
15:07
Kevin Jones
Рет қаралды 236 М.
What is a Fire Alarm System?
11:06
RealPars
Рет қаралды 2,1 МЛН
Fire Alarm Installation UK - Scout Hut Episode 9
45:29
Artisan Electrics
Рет қаралды 162 М.
Fire alarm HVAC shutdown installation on my home fire alarm system
38:30
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 6 М.
Fire Alarm Systems 101
8:00
Jimmy Cox
Рет қаралды 32 М.
How to troubleshoot a fire alarm system ground fault
10:30
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 67 М.
Three Types of Alarm System Signals and System Monitoring
7:43
GPSTC Productions
Рет қаралды 32 М.
Где прячется Снежка ?
0:38
MicroStrategy
Рет қаралды 1,8 МЛН
Small Act of Kindness is also a charity
1:00
PainCare _Trust
Рет қаралды 49 МЛН