Fixing Fire alarm HVAC shutdown problem

  Рет қаралды 6,299

NIC’S - SYSTEMS & ELECTRIC

NIC’S - SYSTEMS & ELECTRIC

9 ай бұрын

Пікірлер: 75
@topher8634
@topher8634 9 ай бұрын
The strips in a heat pump system have 3 functions: (1) supplement the heat pump as auxillary heat; (2) provide heat in the event the heat pump malfunctions as emergency heat; and (3) to add heat back to the air stream when the heat pump goes into defrost. This is called defrost heat. For a heat pump to defrost it switches to cooling and shuts off the outdoor fan so the system can build pressure and heat to melt the ice. If the strips down turn on you're basically air conditioning. Nice job on this. Don't worry I can't draw either.
@rolandmcphail5060
@rolandmcphail5060 9 ай бұрын
great job! typical industrial relays list contact designations as it sits with no power to coil(n.o or n.c) even in complex safety relays with 8 contact sets. you definitely got a deal on that box! i use them often, but prefir the ones with removeable backplates, they make it easier to mount components.
@ulises5369
@ulises5369 9 ай бұрын
Awesome job! I'm glad you finally had that issue addressed.
@Ronnocbot
@Ronnocbot 9 ай бұрын
What about interrupting the common to the thermostat(s). This may result in a bit of a delayed shutdown (in some cases), but takes away the need for all the relays in cutting complete power to the entire HVAC unit. Regardless, nice video. Pretty cool that your family has this trust in you, as they should.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Wireless thermostats so there isn't a wire that can just be cut
@leafmk
@leafmk 9 ай бұрын
Wow! you did a great job fixing it!
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Thank you!
@SDPP992
@SDPP992 9 ай бұрын
I use this same relay and relay socket to control my window AC from my ecobee smart thermostat haha... Nice video!!!
@Dilsonalarmsandelectrics
@Dilsonalarmsandelectrics 9 ай бұрын
I feel like you need to put more dogs in your videos and make the video look better and cuter 😊
@EYL8902
@EYL8902 9 ай бұрын
Awesome! Good job!
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Thanks!
@Firealarmcollectorpeople_1
@Firealarmcollectorpeople_1 9 ай бұрын
Nice job
@user-fr5ry2tv2q
@user-fr5ry2tv2q 9 ай бұрын
Wow that's impressive for fixing an HVAC
@ChrisTopher284765490
@ChrisTopher284765490 9 ай бұрын
Great Job Man !
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Thanks!
@SodiumInduction-hv
@SodiumInduction-hv 9 ай бұрын
Wow!!! Nice!
@TFEAS-09
@TFEAS-09 9 ай бұрын
Well, good job. You fixed it! Now, I did watch the videos, but.. was it hard? I think your house has an awesome system, especially when its connected to the HVAC. That just makes it cooler.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Thanks, no it was not hard
@TFEAS-09
@TFEAS-09 9 ай бұрын
@@nics-systems-electric welcome. That's good.
@nathanbirnofficial
@nathanbirnofficial 9 ай бұрын
34:34 there goes Jackson 😂
@HenBasketFireAlarms
@HenBasketFireAlarms 9 ай бұрын
Nice job fixing it up. Perhaps you can set up another monitor module (or change the garage supervisory tie-in to a dual monitor module) to the other set of contacts on the relay to trip a supervisory should the relay decide to crap out and de-energize when it shouldn’t?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
That could be done for sure the side effect of that is you would have another trouble or supervisory whenever you had a power outage
@HenBasketFireAlarms
@HenBasketFireAlarms 9 ай бұрын
⁠​⁠@@nics-systems-electricyeah, that is true. But it would help troubleshoot should the relay, transformer, or breaker for the transformer decide to not work. Also, have you thought of an HVAC shutdown bypass, be it on the panel, or a keyswitch connected to a monitor module, to not have the furnace repeatedly shut down and restart during testing?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@HenBasketFireAlarms i'd likely just add it to a zone say 99 as well as Bell circuits to be able to easily bypass several things at once
@oaklynnmielcarek
@oaklynnmielcarek 9 ай бұрын
I saw you testing the relay by switching the outlet. Someone could easily kill power to the furnace by flipping that switch. You could consider removing that switch or running a separate power source to the transformer, but this depends on how worried you are about people messing with that switch accidentally or maliciously.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I talked about that in the video. So that should explain most of it but no not that worried it's my house there's not usually a large amount of strangers in the closet of a basement bedroom
@An_Official_Scratcher
@An_Official_Scratcher 3 ай бұрын
Also I've touched a HOT side of a plug not plugged all the way in and it just felt like something moving back and fourth through my finger. Most likely because I was wearing shoes with rubber souls.
@oystergaming6507
@oystergaming6507 9 ай бұрын
well in the usa and canada
@Firealarmperson902
@Firealarmperson902 9 ай бұрын
Good job nic Can you use a firelight bg12lx On simplex panel
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Thanks. No you can not
@Aviationtravel320
@Aviationtravel320 9 ай бұрын
Nic what happend to ur hvac
@verysuspiciousperson
@verysuspiciousperson 9 ай бұрын
Hi Nic! Hru Today
@rayarsenault4774
@rayarsenault4774 7 ай бұрын
nah, I was buying 12x12's for $19 a couple months back.
@An_Official_Scratcher
@An_Official_Scratcher 3 ай бұрын
11:36 *insert android notification sound effect*
@scott192
@scott192 9 ай бұрын
I got zapped by 240 unplugging a cloths dryer, plug was stubborn tried getting a better grip and the plug had come out around an half inch, finger slipped under on both sides and had a good shock
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Yeah that would do it it would definitely bite but at least it's only through your hand so not likely to kill you fortunately
@joshbean39
@joshbean39 9 ай бұрын
The fan should always continue to run for at least 2 minutes to ensure all heat is dispersed and to prevent the a coil from freezing over.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
In normal use yes but that doesn't work for emergency shut down
@joshbean39
@joshbean39 9 ай бұрын
@@nics-systems-electric yup! I have a similar setup but I’m using a Shelly to control the contactor Off the alarm panel I’m just monitoring two outputs one for fire one for alarm and it all ties into homeassistant, not fully ideal but for what it is it’s a step up from what (wasn’t) there
@Dilsonalarmsandelectrics
@Dilsonalarmsandelectrics 9 ай бұрын
That fire alarm wire is fat 😂 it’s just because with my fire alarm system at home I use very thin, fire alarm wire
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Most of this system is wired in 18/3 or 18/5 with bell circuits using 14/3
@IanGSully
@IanGSully 9 ай бұрын
Hey Nic, if you put a door holder in… are you doing to put it on 120 volts AC or 24 volts DC?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Probably 120 V AC is the most common
@IanGSully
@IanGSully 9 ай бұрын
@@nics-systems-electricHow many amps do fire door magnets typically pull?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@IanGSully depends on the magnet often times they have two taps depending on how strong you need the door held open last one I installed I think was like 45 or 80 mA depending on which tap you use so not much at all
@GaryBeltz
@GaryBeltz 9 ай бұрын
Looks like you might have to buy new door switches for the furnace next.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Why is that?
@GaryBeltz
@GaryBeltz 9 ай бұрын
@@nics-systems-electric it wasn’t holding after you closed the furnace back up
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@GaryBeltz because the mounting bracket bent inwards. changing the switches would not fix anything just needed to be bent back out and adjusted
@Alarmsystems829
@Alarmsystems829 9 ай бұрын
Why do you not use notifier inspire self test system?
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Because it's not an option or available
@IanGSully
@IanGSully 8 ай бұрын
Hey, do you think it should still turn off the heat pump as well?
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
It does
@IanGSully
@IanGSully 8 ай бұрын
@@nics-systems-electric Like at the exact same time or does the heat pump shutdown on some sort of limit?
@nics-systems-electric
@nics-systems-electric 8 ай бұрын
@@IanGSully when the control board loses power the contactor disconnects
@AshCash1234
@AshCash1234 9 ай бұрын
i need help with setting up a fire alarm plz help me...
@schlabberdog
@schlabberdog 9 ай бұрын
Why not just add a shut trip expansion module to the main HVAC MCB? You don't have to worry about power consumption of relays/contactors and since there is no transformer needed (as long as the fire alarm relay can operate on mains voltage) there is one less thing to potentially fail. Sure, you have to manually reengage the MCB after the fire alarm triggers, but since that should rarely happen it seems like the easiest solution to me.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Very expensive if even possible to find. there is only one relay extremely extremely small power consumption and having to manually reset would be problematic
@schlabberdog
@schlabberdog 9 ай бұрын
Huh, must be a US/CA thing then. Over here in the EU every major MCB vendor offers one. Just checked and the one from ABB costs only around 40€
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@schlabberdog around $160 for a 60 amp which my furnace would need two shunt trip breakers unless I put in one 100 amp at the panel which is getting quite costly and then would have to be reset
@Pbell
@Pbell 9 ай бұрын
Nic be mindful of using these relays you buy on Amazon and such, this looks like an Amazon brand. They may not be listed devices buy UL or the Canadian equivalent. I spend the extra to buy a quality listed brand just in case it burns my house down one day my insurance company won’t put the blame on me. Also I do see the no name ones with the listing symbols on their typically those are fake in my opinion and just printed on there.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Can't remember if this one was brand new or came out of equipment from somewhere insurance is definitely pretty relaxed here that's crazy that they would come at you for that they would never look into anything that far here lol
@sommawolf4273
@sommawolf4273 9 ай бұрын
Couldn't you just wire the safety switch for your smoke detectors into the door safety switch so in the smoke detectors go off it opens the door circuit which would kill the furnace
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
I'm assuming you were thinking of the smoke detectors having a relay built into them which they do not and if they did that would be a local relay to each detector
@eDoc2020
@eDoc2020 9 ай бұрын
I know it doesn't matter in terms of safety but did you check to see if the compressor shuts off with this system? Also I probably would have bypassed that old switch in the closet, you already had your wire nuts out.
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Yes the contactor let's go when the control board loses power
@NyxKemo
@NyxKemo 9 ай бұрын
Cutting the thermostat R wire would have been so much simpler, the R wire is the input to the thermostat which is what the thermostat uses to then connect the R wire to other wires to control the furnace
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
Not when you don't have a R wire
@NyxKemo
@NyxKemo 9 ай бұрын
@@nics-systems-electric hmm, thought every furnace had one
@NyxKemo
@NyxKemo 9 ай бұрын
Also having the relay on constantly isn’t good for it, I’ve had relays melt because i left them on too long, ideally you want the relay to be off all the time, then turn on when the fire alarms go off
@nics-systems-electric
@nics-systems-electric 9 ай бұрын
@@NyxKemo not when you have a upgraded system in a 1976 house with wireless thermostats with just two wires being used to give them power
@NyxKemo
@NyxKemo 9 ай бұрын
@@nics-systems-electric usually the R wire will be in the thermostat receiver box unless the thermostat receiver is built in the control circuit of the furnace
Adding a fire alarm pull station Notifier NFS-320c home fire alarm system
37:53
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 14 М.
Fire alarm HVAC shutdown installation on my home fire alarm system
38:30
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 6 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 15 МЛН
Хотите поиграть в такую?😄
00:16
МЯТНАЯ ФАНТА
Рет қаралды 2,2 МЛН
Fire alarms keep going off at middle school EST quick start problems Saturday troubleshooting
1:10:58
How To Properly Change Batteries in A Fire Alarm Panel
4:00
Secure It Securities Corp
Рет қаралды 1,1 М.
Duct Mounted Smoke Detector
4:02
MEP Academy
Рет қаралды 7 М.
23 - Monitor Modules - Introduction to Fire Alarms
9:45
Joe Klochan
Рет қаралды 96 М.
Inspecting And Testing Of Fire Alarm Systems NFPA 2005
26:50
SpenciTech
Рет қаралды 5 М.
Replacing fire alarm system at elementary school. Full addressable replacement day #1
26:15
Wiring in Smoke Detector on HVAC Package unit
3:41
HVAC Service Technician Talk
Рет қаралды 25 М.
HURRY THE AC IS ON FIRE
27:43
HVACR VIDEOS
Рет қаралды 102 М.
Fire alarm system fan shutdown demonstration
8:00
David Redpath
Рет қаралды 1,2 М.
ПРАНКУЕМ ЧАПИ🙈🙈🙈
0:20
Chapitosiki
Рет қаралды 5 МЛН
ПРАНКУЕМ ЧАПИ🙈🙈🙈
0:20
Chapitosiki
Рет қаралды 5 МЛН
DEFINITELY NOT HAPPENING ON MY WATCH! 😒
0:12
Laro Benz
Рет қаралды 49 МЛН