Demo of Sewer Backflow Prevention Device at ACE 2010

  Рет қаралды 257,065

pwgroup

pwgroup

Күн бұрын

Demo of Sewer Backflow Prevention Device - taken on the floor of the ACE 2010 Expo held in Chicago at McCormick Place in June 2010

Пікірлер: 71
@jimohio5266
@jimohio5266 4 жыл бұрын
I installed one in February, 2020, and it passed its first test yesterday. I was watching with a flashlight when the yellow gate floated up and closed. I celebrated with a beer. Keep it clean and it will work.
@r828realty
@r828realty 3 жыл бұрын
Keep it clean...what do you mean?
@jimohio5266
@jimohio5266 3 жыл бұрын
@@r828realty iI's necessary to unscrew the plug and flush out the muck with the hose a few times a year. Enough muck and the gate will stick in the open position.
@PabloTaboadaNYC
@PabloTaboadaNYC 7 ай бұрын
where can i buy one here in the US? thanks
@jimohio5266
@jimohio5266 7 ай бұрын
​@@PabloTaboadaNYCAmazon
@developthebrain91
@developthebrain91 4 жыл бұрын
Your videos have helped us a lot to learn so many things. These days, I feel KZfaq is not only a place to entertain watching random videos but also a great place to learn things of our expertise. I have learned more things on KZfaq than at my university. Unfortunately, we don't get any certificate for learning so many things. Keep making more videos...our blessings are with you.
@alexj0101
@alexj0101 8 жыл бұрын
I love how the crowd is going nuts over something else as the valve closes.
@ZariaWorldwide
@ZariaWorldwide 6 жыл бұрын
I know, right?!
@JS-dx2zq
@JS-dx2zq 3 жыл бұрын
I don’t think it’s because of that
@corylangston9784
@corylangston9784 2 жыл бұрын
Timed pipe hot tapping competitions are going on all throughout this show.
@krisludwig5704
@krisludwig5704 6 жыл бұрын
I have one of these installed. You have to clean it on a regular basis so it does not get clogged. Debris gets stuck in the corners near the flap hinges. We had a serious flood because it had been a few months since checking it and the flap hinge was blocked.
@pwgroup
@pwgroup 5 жыл бұрын
Thanks for the feedback on this Kris. We had asked the rep about that because it was something we anticipated could happen so it's good to hear your experience. But I am sorry to also hear about it leading to damages.
@nahnahson
@nahnahson 4 жыл бұрын
That was my thought. Solids would prevent it from working properly
@Csrflores79
@Csrflores79 4 жыл бұрын
Can you please tell me who install it for you?
@jim0266
@jim0266 13 жыл бұрын
@pwgroup If the valve is closed due to backflow from the sewer line you will not be able to discharge any water until the valve opens once again. The beauty of the Mainline is that if you are experiencing heavy rains and suspect your valve could be closed, simply open the access panel and look through the transparent top to see if the valve is closed or open.
@SilverCymbal
@SilverCymbal 7 жыл бұрын
Would love to see this 10 years after its installed.
@MrTexasdieselguy
@MrTexasdieselguy 4 жыл бұрын
I bought one, got tested when the sewer backed up a few months later, and it failed miserably... looks neat, didn't work for me.
@lukeWiz44
@lukeWiz44 4 жыл бұрын
Silver Cymbal hey! Love your channel!
@MisterGreenGuy
@MisterGreenGuy 4 жыл бұрын
@@MrTexasdieselguy This is happens because solids like toilet paper clog up the mechanism. Im a plumber by trade and these things are nothing but problems.
@MisterGreenGuy
@MisterGreenGuy 4 жыл бұрын
It would never last that long... In the demo it works great because he's using nice clean water. Sewer water is not clean! Start adding toilet paper, wipes an other solid matter and the demo would fail guaranteed.
@MrTexasdieselguy
@MrTexasdieselguy 4 жыл бұрын
@@MisterGreenGuy exactly
@asianmohamed2065
@asianmohamed2065 6 жыл бұрын
Okay so when the lid comes up and closes the passage, what would happen if sewage from the house is also present and flowing at the same time? Basically the sewage at each section are opposing each other. It's just similar as to having your septic passage blocked. Then the water will just start filling up the passageway and ultimately the shit will come back to your toilets and sinks.
@franksindelar3897
@franksindelar3897 6 жыл бұрын
If that happens, I'd assume you'd see your own toilets/sinks/showers not flowing properly, go check the valve. In any case you don't end up getting your neighborhood's effluent into your own home.
@LeftCoastStephen
@LeftCoastStephen 3 жыл бұрын
Looks just what my fathers house needs after 2 floods in 2 years. What about an alarm so you know not to run water or flush?
@mariosifuentes5994
@mariosifuentes5994 2 жыл бұрын
What happens if you run an auger trough? Seems like will damage the flapper and get stuck in the way back
@454Casull
@454Casull 11 жыл бұрын
No, only if the seal fails. Otherwise the hydrostatic pressure simply increases and presses down on the seal even more.
@neversayneverh1
@neversayneverh1 7 жыл бұрын
I just don't see this thing working consistently, there always is solids in the water, even if it is only 5% and there is a lot of air, if the system is not discharging for a week or two the solids tend to dry up if they did not flow out. Seems a little bit of feces and some air to dry while I'm on a two week vacation would cause the flap door to get stuck. If you have to clean it once a week I highly doubt that will happen. Maybe a wash port and a solenoid on a timer to purge it might make this more reliable and possibly a test procedure so the homeowner can verify that it is functional.
@pwgroup
@pwgroup 5 жыл бұрын
The cleaning feature is a good idea because I also doubt most people would want to spend that much time fussing with it. Would be best if they had a water hookup to it where you just pressed a button to clean it, but I guess there would be concerns connecting potable water to a component in the sewer system.
@pwgroup
@pwgroup 14 жыл бұрын
@poohbearpost that's what we liked about it too. We always worry about the regular type of check valves getting stuck and causing a backup. Plus we liked the see-through access for checking and accessing it.
@pwgroup
@pwgroup 13 жыл бұрын
@jumpdance24 We also asked about the maintenance and then the chance of debris causing failure. He said the maintenance is easy because it is accessible through the top in an open pit and has a clear lid to help with easy inspection. He said due to the design, debris does not cause issues. The pressure holding the flap closed is from the water that is trying to back up. Not sure if it could continue to allow discharge during a backup though. You could checkout their website for more info.
@kalnory146
@kalnory146 2 жыл бұрын
When fills how stop it from overflowing into house? When the water reaches the top of the box for example
@darrenr1194
@darrenr1194 3 жыл бұрын
This design is flawed in a sense that if it backs up with debris there is a chance it may not fully go back down causing a blockage. It would be better if the mechanism was ontop of the pipes that way gravity always kept it closed and when you flush your toilets it pushed it open. This would make it harder for debris to get stuck behind it if it ever backed up.
@Films128
@Films128 9 жыл бұрын
Does anyone know if these would be good to install if you're on a Septic System? To prevent the chance of ever having a backup?
@victorboyko6124
@victorboyko6124 2 жыл бұрын
Clear demo but what were they thinking recording this DURING the noisy opening hours of the Expo. Couldn't understand a lot of the explanation, unfortunately.
@jacobyodernation
@jacobyodernation 12 жыл бұрын
i would like to see the demo let the water get above the gate. wouldn't that equalize the pressure and allow the gate to open?
@mikehumber695
@mikehumber695 7 жыл бұрын
jacobyodernation
@MisterGreenGuy
@MisterGreenGuy 4 жыл бұрын
No because you have whats called differential pressure. The pressure on the other side of the gate will be higher and the static pressure on the gate will push it shut. It would actually push it shut even tighter the higher the water got.
@peterbuiltcummins413
@peterbuiltcummins413 4 жыл бұрын
Ok question, how will the floatation action work against raw sewing with low water content
@darrenr1194
@darrenr1194 3 жыл бұрын
It won't and rather remain open and allow a backup to occur. Best ones have the flap ontop which remain closed at all times and only when you flush your toilets or run your sinks from inside does it push the flap open and allow your sewage to exit your building.
@MH01684
@MH01684 2 жыл бұрын
What happens when solid matter gets under the flap in the open / Close function
@peanut3679
@peanut3679 6 жыл бұрын
But where does the water go??? If the pipes are blocked, it has to go somewhere..
@MassDynamic
@MassDynamic 6 жыл бұрын
the purpose of the device is to make sure that water, in this case sewage, only flows in one direction, away from your house. if the device is triggered, that means the flow of sewage is towards your home, which also means any sewage that is going down the pipes during this time will be stuck in the pipes until the sewage flow returns to normal. this device simply stops sewage from flowing into your home; it doesnt fix the problem that's causing the sewage backup.
@jayhamilton7573
@jayhamilton7573 4 жыл бұрын
It'll back up in the pipes and manholes. As soon as the municipality knows there's a problem, they would set up a pump to bypass the backup and clear the blockage.
@MisterGreenGuy
@MisterGreenGuy 4 жыл бұрын
In the streets if it gets higher than the manholes. Better that it flowed down the street than down the floor of your house.
@pwgroup
@pwgroup 12 жыл бұрын
We were also wondering about that and asked what would happen if debris got caught. He said the design of the product helps prevent that. I'm wondering if it is because normal flow would not cause debris to get caught so it would only happen if water started flowing back. And at that point, the water is more likely to be stormwater than wastewater since backups happen due to an increase in flow from rain. So perhaps there is less chance for debris to even be in the water at that point.
@mikejohnson4723
@mikejohnson4723 4 жыл бұрын
There is always a chance that wastewater will back up due to a storm sewer pipe leaking into a refuse sewer causing the toilet water to back up into a persons house via the toilet drain. Like it happen in Millersville, Pa, Lancaster county Pa. Several years ago,and Millersville didn't care about it either. They said that they have immunity from being responsible because of what happened in their town due to their own fault. Typical liberal thinking.
@gangstaBJK
@gangstaBJK 3 жыл бұрын
Would this stop mice getting in through sewer?
@levelup1279
@levelup1279 3 жыл бұрын
No not at all
@rosetriferomorrison9583
@rosetriferomorrison9583 10 жыл бұрын
what happens if the main sewer is in front of your house and is blocked throwing 2 feet of water and then the sewer backs up into your basement and shower, and you install the backflow preventor and it stops the water from coming in, what happens to that water as the whole street has 2feet of water?
@pwgroup
@pwgroup 10 жыл бұрын
If you have a backflow device and your home is above the level of the water, you should not get any water into your home. The water should remain in the street and sewers and could also go into other basements where there are no backflow devices. If there are storm sewers or combined sewers (the ones connecting both sanitary and storm) the water eventually flows to streams and rivers. This discharge to a water body is often regulated and must be reported by the community as would any backups into other homes.
@msujaj9
@msujaj9 13 жыл бұрын
Does any company use this product in Chicago, Illinois? If so, I would like to contact that company.
@haseebahmed6278
@haseebahmed6278 5 жыл бұрын
Sewer typically has solids too. This seal will fail in no time...
@yourteam8187
@yourteam8187 2 жыл бұрын
What distributors carry this in the Chicago area?
@pwgroup
@pwgroup 13 жыл бұрын
@msujaj9 I am not familiar with any. It would probably be best to contact the manufacturer of the product to get more info on actual installations in our area: backwatervalve com (youtube won't let me post this in the normal format)
@MattTrevett
@MattTrevett 12 жыл бұрын
I don't think it needs a clear lid.. :)
@bhesuse5596
@bhesuse5596 7 жыл бұрын
how can I avail or where to buy this product. im from philippines. I need this badly. thanks.
@sprankadeedoych
@sprankadeedoych 13 жыл бұрын
@msujaj9 I was just thinking the same thing. I'm assuming that you got flooded this morning...
@SiyamandRashid
@SiyamandRashid 5 жыл бұрын
What if water is coming from both side at the same time.?
@hardkore360
@hardkore360 5 жыл бұрын
Your flap will be closed, therefore any discharge from your home will simply go back into your piping, it will eventually go up your sinks, tub/shower, and toilets if it has nowhere else to go.....
@pwgroup
@pwgroup 5 жыл бұрын
It would depend on the pressure if it would flow out or not. If I had one of these, and I knew conditions were backing water up to it, I would probably try not to discharge water to the sewer until the water went down.
@5101annamaria
@5101annamaria 4 жыл бұрын
Where it is installed, which exactly place?
@RayleighCriterion
@RayleighCriterion 3 жыл бұрын
Where the main sewer pipe enters the building.
@earthwormjim92
@earthwormjim92 Жыл бұрын
Oh dear.
@erfanchyshimul
@erfanchyshimul 6 жыл бұрын
how can get it bangladesh?
@PlausableApple4
@PlausableApple4 11 жыл бұрын
How much back flow pressure can the fitting withstand?
@levelup1279
@levelup1279 3 жыл бұрын
1.264 million
@Prisonmike89
@Prisonmike89 3 жыл бұрын
Nice until you get a turd or wad of toilet paper stuck in there
@properlauguagestep7584
@properlauguagestep7584 2 жыл бұрын
No
Cleaning a sewer back flow valve. HOW TO AND WHY
8:21
aspeninspection
Рет қаралды 194 М.
Backwater Valve Installation
7:44
cityofwindsor
Рет қаралды 329 М.
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 110 МЛН
Zombie Boy Saved My Life 💚
00:29
Alan Chikin Chow
Рет қаралды 9 МЛН
Can This Bubble Save My Life? 😱
00:55
Topper Guild
Рет қаралды 70 МЛН
Backflow Prevention Valve
1:21
The Supreme Industries Limited
Рет қаралды 32 М.
Backwater Valve failure vs  performance
1:44
Flood Ready
Рет қаралды 55 М.
Stop Basement Sewer Flooding: Sewer Flood Gate Valve Demonstration
6:24
Balkan Sewer & Water Main Service
Рет қаралды 7 М.
Backflow Preventer Repair
4:13
Fast Fix
Рет қаралды 220 М.
Backflow Valve Installation - Direct Waterproofing
2:31
Direct Waterproofing
Рет қаралды 81 М.
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 110 МЛН