Battery Discharging as On-Grid Mode by setting time,power & percent level
Пікірлер: 44
@anthondiy2 жыл бұрын
Thank you lods sa info dagdag kaalaman, installer here full support
@jahmer07 Жыл бұрын
Lodi ilan po kaya ilalagay kong percentage or voltage sa battery ... 16kw po na solis hybrid... natunog lng yung inverter...eh
@cosminradulescu8948 Жыл бұрын
Hi, Can Deye inverter work with lifepo4 batterys with no bms commnunication ThankYou?
@stevesantos5594 Жыл бұрын
Sir pwedi mag tanong ung load side Ng deye gawin Kong priority at emergency nlng ung grid,, 10kw inverter hybrid, madalas gawin ko ksi ung load side Ang nilagay ko sa emergency Ng ats...
@solar_isangpinoytech.6328 Жыл бұрын
Pwede make sure na hindi exceed sa 80% capacity
@gilbertmeneses11 ай бұрын
Anu kaya problem non sir may kulang b ako s setting.
@anthonysaab1186 Жыл бұрын
Hello, I'm using a Lithium battery with my Deye and the Time of Use with Generator does not seem to work. Should I choose "Use Batt %" instead of "lithium" in battery mode eventhough I'm using a Lithium battery, or is my inverter faulty?
@coolestspott69 Жыл бұрын
hello, do you have a BMS connection in your lithium battery?
@gilbertmeneses11 ай бұрын
Sir can u help me Yong deye 5k install ko 1st@ 2nd month ok ang bill nya bumaba ng 4k Then pang 3 month up to present tumaas ng 7 k bill .
@solar_isangpinoytech.632811 ай бұрын
Here sir.. contact me via Viber pa send po ako ng billing detail 0915 914 0278
@wasak032 жыл бұрын
yung sakin bakit nag discharge kahit 100% 9am to 3pm diba dapat hindi nagbibigay si battery sa load ng bahay?
@solar_isangpinoytech.63282 жыл бұрын
If naka time of use ang system magbibigay po yan talaga.. To assist you.. Search me on fb
@rudyocampo80492 жыл бұрын
maganda ito sa ibang bansa, na kunh saan masmura grid sa gabi. pero sa atin hindi applicable. ang pinaka effective na gamit ko dito ay set lahat to 20% at check grid charge, sa ganun maximize gamit ng battery habang safe yung lifepo4 battery ko.
@arielsharonderiada3382 Жыл бұрын
20% po sir meaning ba nyan magbibigay si battery ng 20% discharge power only?
@rudyocampo8049 Жыл бұрын
hindi po, meaning mag discharge si battery hanggang 20% lang po matitira sa total full capacity ng battery.
@arielsharonderiada3382 Жыл бұрын
Pag naka check ang grid charge sa 80% meaning nyan pag mababa sa 80% dapat magchacharge si deye sa 80%? Tama po ba?
@rudyocampo8049 Жыл бұрын
yes po
@kuyaondo53062 жыл бұрын
Master ask q lang If may 8 ako na battery 250ah bawat Isa tas Ang connection q ay apat na naka series tas 2 parallel.. My question Is ilan Ang capacity Ng battery q. Tns master Sana magkita Tau uli..
@solar_isangpinoytech.63282 жыл бұрын
8pcs 250ah 4s2p=500ah
@acealbertouano2 жыл бұрын
HI. My DEYE "Grid Charge" is not working. Even if I set to Grid Charge (checked) in the Time of Use. What's the possible problem? I set the time from 00:00 to 05:00, Grid Charge Checked. But still during that time, my battery is still discharging.
@solar_isangpinoytech.63282 жыл бұрын
Uncheck your Time of use Grid Charge, Go to Battery Setting and put State Of Charge(SOC %), check the box Grid Charge Grid Signal
@deehive2 жыл бұрын
@@solar_isangpinoytech.6328 sabay dapat ang grid charge and grid signal?
@mengnggapo49102 жыл бұрын
Hi sir, meron ako deye 5kw deye inverter with meritsun powerwall, pwede ko po kayo macontact via messenger?? Ano po name nyo sir, may trouble po kasi, nag F39DCLLC(overcurrent) INVERTER ni client. Wala nmaang motor loads sa emergency panel na ginawa namin, ilaw at ref lang, 300w consumption pero nag fafault
@solar_isangpinoytech.63282 жыл бұрын
Search me as Richard Oliveros
@ziadkhalil49132 жыл бұрын
Hello pls I have Deye inverter 8KW but is not charging on grad and not charging on generator it’s only charging from PV
@solar_isangpinoytech.63282 жыл бұрын
Go to Battery setting and check the percentage SOC of your battery Check the box
@humbeym48782 жыл бұрын
hi sir napanuod ko ung video pero parang di nasagot ung iniisip ko....may output po ba ang EPS load kahit di mo iclick ang time of use? I mean may output sya na 220v kahit wla kang baguhin jan or iclick sa time of use?
@solar_isangpinoytech.63282 жыл бұрын
Yes may Output yan even naka gridtie or offgrid mode... The "Time of Use" is only battery function as gridtie discharging power 24hrs not for offgrid..
@solar_isangpinoytech.63282 жыл бұрын
LOAD or EPS side: automatically has the output of 220vac, even without battery the built-in ats turn on going to the load (eps) output..
@aldymcpndg1429 күн бұрын
Pwede po bang e maximize sa 100 amp ang grid charge sa battery?
@solar_isangpinoytech.632828 күн бұрын
Only acceptable current lang ang pwede sa battery depende sa manufacturer!..pwede din i adjust ang battery charging ng inverter base capacity rating...if you do that mas lalong lalaki ang bill mo sa kuyente..
@bicolpartidosolarista14922 жыл бұрын
sir ginagamit ang check or nilalagyan ng check sa time of use para i charge ang battery depend sa percentage or para grid ang mag energies sa load nalito ako sa sinabi nyo sana masagot nyo salamat
@solar_isangpinoytech.63282 жыл бұрын
Kapag naka check ang Time of Use mag di discharge ang battery by schedule of time list na naka power & percentage set.. Grid charge & Gen sa left side kapag nilagyan ng check mag cha charge din siya
@herbertpalines4695 Жыл бұрын
Sir, paano po baguhin yung battery percentages level sa System Work Mode?
@solar_isangpinoytech.6328 Жыл бұрын
Touch mo lng sir white box then button arrow up & down to adjust
@OceanSummer0382 жыл бұрын
Hello po, my settings din ba po ba si deye na sa solar panel lang sya mag charge? Thanks 👍
@solar_isangpinoytech.63282 жыл бұрын
Yes! Dont select ang grid charge matic na yan sa solar
@OceanSummer0382 жыл бұрын
@@solar_isangpinoytech.6328 Salamat po sir, sana gumawa ka din po ng video regarding sa AC coupled system gamit ang deye hybrid inverter. Salamat po 👍
@user-tk4dv9ht8s Жыл бұрын
Hi :) I'm trying to achieve these : Battery will start and works in parallel with grid at 9PM Battery will stop once it reach 80AH discharge capacity. Grid will take over . At 8am Solar will start supplying the Load and and will also start charging the battery . Grid will help supplying the Load. please help.
@solar_isangpinoytech.6328 Жыл бұрын
If your battery's enough for the night you can adjust battery discharge capacity at battery setting and time of use, can adjust bit higher power to your requirements.. but if your battery is unsufficient don't set too much!
@rockypallogan6675 Жыл бұрын
Sir, pwede kayo makontak sa cellpon nyo. Salamat sit
@solar_isangpinoytech.6328 Жыл бұрын
09159140278
@franciszosa61542 жыл бұрын
Sir gdpm..tanong lng po bakit mag zero ang grid minsan na kahit walang brown out..unit ko deye 5kw hybrid..salamat sa sagot po.
@solar_isangpinoytech.63282 жыл бұрын
Go to grid setting, Check your frequency set range if correct