If your display is blank, unreadable, or if it is showing symbols that do not make any sense, this video will teach you how to troubleshoot the display.
Пікірлер: 69
@fiveola7 жыл бұрын
My Hunter Pro-C has a "No AC" readout from the face pack. I've tested w/ a 9 volt battery and it seems the face pack is still good. Does this mean that I will need to test the transformer? Please advise. Thank you.
@dougbaney44044 жыл бұрын
I have a Hunter Pro-C, it uses the PCM300 Modules. Two of my stations (7 & 8) have undesired delayed turn-on (delayed water flows) or they don't turn on at all. If I operate manually, sometimes they turn on after several minutes of delay. Any suggestions?
@keithgates71667 жыл бұрын
we have an X-core, and wish to eliminate even or odd watering days which I feel may be conflicting with our basic programme of watering twice per night every wednesday. Presumably resetting and reprogramming is one way?
@Maximara6 жыл бұрын
Our Hunter Pro C controller display is blank but I can manually turn on our sprinklers via pressing the arrow keys and using manual mode blind. It however doesn't run for more then a minute and past station 8 doesn't turn on the the right station (we have 10 stations programmed)
@erickarchila47917 жыл бұрын
I have a Hunter Icore that's is displaying station active fault What does this code means and how can I fix this problem?
@markwilliams9896 жыл бұрын
Good morning. My irrigation system controller display is blank. I'm try to fix but I can't repair it. The brand is Hunter X-core model XC-4. It directly connects with the house general electronic box when I turn off the irrigation button inside the electronic box, the controller displays "no AC". After I turn it on it's blank. I'm anticipate the controller is still good but just because the hurricane results it something wrong. If possible can you help me out please? Thank you.
@bhillemn4 жыл бұрын
I have a ic-600-pl and the clock appears to be "stuck". i can see the time, i can set the time but it does not advance. I don't see any errors and i can run manually but nothing runs with timer. Any suggestions? Thanks
@erinflanagan1008 жыл бұрын
I cannot get the display to change regardless of which setting I am on. I went through the reset steps and I still cannot change the display. I am trying to correct the time and date and no matter how long I hold the arrows down, I do not get any flashing numbers/dates. Similarly, when I to the watering schedule, I don't get the different programmes (A, B, C etc.) and I cannot access any of the start times, run times etc. The unit is about a year old.
@karjack117 жыл бұрын
i bought a house with a existing hunter system and it works great but it runs every morning no matter what i set my schedule at or my run time duration. i havent found a way to fix this so i am having to cut my station run times from 48 down to 30 and eventually down to 20 to avoid a expensive bill
@clg75006 жыл бұрын
I have a XCore XC6001. When I try to run the stations manually, sprinklers do not come on and the "Automatic Watering" sign flashes. I have turned the rain sensor to by-pass but still having the issue. Any suggestions?
@dynamitewizard65507 жыл бұрын
Hello. i have programmed everything as instructed, but i can't get any zones to actually start watering both in the manual or programmed modes. i have cycled to each of 7 zones and the minutes will count down without watering. Please help! David
@andynitz51915 жыл бұрын
I have an ICC controller with 14 zones. I can run zones 9-14 individually they show on the display. but trying to set up program start times I only have zone 1-8 . Any troubleshoots on that ? Thanks! Andy
@202BUBBA5 жыл бұрын
I have a new Pro C and the issue is the programming is set for on Sunday and Wednesday. However, with the unit in run, the unit does not start unless I manually recycle the switch all the way around to run again. Can you help?
@kathleentollett62859 жыл бұрын
What does the "trash can with a flag on the lid" icon mean? I have systems 2 & 3 coming on at the same time when I try to run it automatically and manually. Help!!!
@volcanicaj35206 жыл бұрын
The screen say “P ERR”. How do i fix this? Sometimes it says “OP ERR”. Thanks.
@anthonypulli62718 жыл бұрын
I have a customer who states the controller is making a ping noise and the display flashes when it does this. Other than that he states everything is working fine?
@spencerjefferies46727 жыл бұрын
I have the Hunter PC-300 model. It has power, but the screen is blank. It does flicker a little as I turn the dial. Please advise.
@luciapires59853 жыл бұрын
I Have X-Core indoor, that the display appears on blanc. Removing the current AC display the message ON AC and after stay on blanc. I put a new currente AC and the display continues on blanc. I analysed and have energy. What can be the problem.
@debbhak7 жыл бұрын
I am experiencing an "Err" code on my station #5. What can be done?
@matthewterrones61244 жыл бұрын
I have an Umbrella symbol in on the display and won't allow operation, any idea what the symbol means?
@dalebonebrake50724 жыл бұрын
I have a Hunter Pro C system that the timer will not turn on the system at the set time. Never had issues before. What can I do to fix this problem?
@RashtAbarar7 жыл бұрын
Hi, on my Hunter Pro-C model similar to the question below no zone comes on even in manual mode. The valves are working fine by turning them 1/2 turn. I noticed I have no power to AC1 in the controller but 28v in AC2. All zones are also showing 28V. Is AC1 supposed to be dead or should that also be carrying 28v? If all zones are not working, this can not be valve/solenoid problem, since they were all working fine at one time. Any help is appreciated.
@RashtAbarar7 жыл бұрын
Thank you for your response. Perhaps I wasn't clear enough on my question. I performed all the tests that you have suggested and the fact that the controller and the valves were all getting proper voltage but not working was a mystery. I would see on the controller that each zone would pop up but no water was coming out. So here is what I did that solved the problem. Even though I had flipped the rain sensor to bypass at the controller the system was detecting rain or moisture. The next step was to actually pop off the top of the rain sensor and physically disable it, not just bypass it. That did the trick and all zones came on with water pouring out with no problem. Come to find out that due to the high humidity there was some moisture in the rain sensor which was preventing the proper operation. Thanks for your help and I hope my solution is useful to others.
@chrislillico22076 жыл бұрын
I'm getting an error when I try to turn a zone on. How do I fix it?
@jtdenniston6 жыл бұрын
I'm getting a station# ERR on all stations, but when I run a wire directly from power to any station, the sprinklers come on for that station. The power I'm getting from the 24VAC is approx. 30V.
@jtdenniston6 жыл бұрын
Thanks so much! I found that all the stations where having an issue and returned the whole unit and got another one. Works like a charm! Thanks so much for your fast reply!!
@davidkulas98474 жыл бұрын
On my X-Core 600 I'm getting just a '6' on the display when trying to run a station manually. And it doesn't run. Doesn't matter what station (of 4) I try. Any thoughts?
@lovepizzo4 жыл бұрын
Am also having the same any help?
@Gato-pk9lf7 жыл бұрын
mine is saying error, what do I do for that?
@lindatavares32886 жыл бұрын
On my run times, stations 1, 2 & 3 say USEd. I can't figure out what that means & how to get the mins I need on it?
@TatuSaloranta2 жыл бұрын
I have the very same problem, drives me crazy. Seems as if the whole controller must be hard reset to get rid of this -- and manual has nothing to say about this code.
@dashound107 жыл бұрын
I keep getting a double beeping noise every few minutes, what does this mean? Please help!
@sammycash222066 жыл бұрын
Hello, My Hunter Pro C controller display OFF sensor and would not run Auto or manual all stations , only way for it to run is manual station by station, looking at your other videos, seems the issue related to rain sensor ,I have tried switching to byPass
@omarfmd6 жыл бұрын
I have the same issue with my EC-600. Is there any solution?
@shirleyconway13627 жыл бұрын
The controller says OFF for every status. It has power. Does it need a new battery?
@kenvasquez95246 жыл бұрын
Timer display has ERR 1 code... What does this mean?
@Burleybutt3 жыл бұрын
I have an older Pro C 300 and need a new main controller, model # 466500. Mine is gray and the newer ones are black. Mine has a slot in the back for sliding into the cabinet. I don't think the newer ones do. Does the replacement one have to have a groove in the back to be able to mount it? Thank you.
@Hunter_Industries3 жыл бұрын
If your Pro-C has a slidebar indicating Power On (locked) Power Off (unlock) you can use the main module for the version 3 PC-300. The part number is 466500. If your backpanel has clips to connect the modules you will have to replace the whole controller because the backpanel for that controller is not compatible with version 3 modules. Here is a web address to search for a distributor who can sell you our products. www.hunterindustries.com/distributors-in-north-america
@jimmysharman17322 жыл бұрын
My Pro-C is one year old and all of a sudden the zones started messing up. I tried the reset process as your video instructed. Pro-C reset itself to 12:00a/m. But when I turn on with arrow button that will start all zones, the timer stars but no water flow on zone 1. When zone 2 starts, it is actually zone 3 and it runs until set time expires. I can start each zone 1 at the time by opening the bleed valve slightly on each zone and it will run until I close bleed valve. The same with zones 2 & 3. Is the controller bad?
@Hunter_Industries2 жыл бұрын
Please contact Hunter Technical Services for help with your problem. By email support@hunterindustries.com, or phone 1800-733-2823. If you call by phone please be in front of the controller with a multimeter so we can walk you through some diagnostics. We are available MON-FRI 6am to 4pm PST.
@terrowsnap22012 жыл бұрын
Make sure the ribbon cable is securely in the face pack. I had a similar problem where mine was going nuts and I accidentally pushed the ribbon cable in securely and everything went back to normal.
@Steelringstrue3 жыл бұрын
My XC400i does not show the time of day when idle 'RUN" position. It's brand new and I'm able to adjust all settings. Is this feature still on the newer released models???
@Hunter_Industries3 жыл бұрын
Normal status should show the time and date. If it doesn't try moving the dial to another dial setting and back to Run. If that does not fix it try performing a factory default. Use this web address to learn how to do that if your not sure. www.hunterindustries.com/support/pro-c-clearing-controllers-memoryresetting-controller
@kathystephens11386 жыл бұрын
Controller reads P Err. What does that mean?
@NexusRocks77 жыл бұрын
Hi, i keep getting a flashing sprinkler symbol, when I try to run the system, and the irrigation is on. How do I fix this problem?
@NexusRocks77 жыл бұрын
It is a Pro-C sprinkler system
@davidcline43986 жыл бұрын
My Hunter ProC (2003 model) has stopped working. My rain sensor had stopped working a few years ago so I've had the rain sensor switch set to BYPASS. A week or so ago, my display went completely blank and remains that way no matter what buttons are pressed or the RUN dial turned. When I slide the rain sensor switch to the ACTIVE position, the display comes on and displays "OFF sensor". I reprogrammed the date/time/sprinkler run information, but when I tried switching to rain sensor switch back to BYPASS the display went blank again. I reset the display per instructions and also cycled the controller power per the troubleshooting instructions as well, but it the screen remains blank when the rain sensor is set to BYPASS. Is there anything else I can try to troubleshoot??
@mayenomar7 жыл бұрын
My drip system isn't controlling the water anymore. Turned all programs off and my drip system just continually runs with no control. What can I do?
@leopatricpatrick34856 жыл бұрын
Omar Mayen off this help you you need check the electric valve the is bad
@mangkadyoable3 жыл бұрын
i have an ACC and right now, it displays OFF even on the RUN position. what could be wrong with it? I have tried a hard reset but still
@Hunter_Industries3 жыл бұрын
Please email our support team for help with this question. Contact support@hunterindustries.com so our technical services team can assist you.
@samuelchicas58336 жыл бұрын
My timer works 1 and 2 stations but 3 and 4 say 3e rr , 4e rr then next 5 stations works just fine
@samuelchicas58336 жыл бұрын
Hunter Irrigation thank you very much
@royblake80017 жыл бұрын
I have a Pro-C controller from 2013 that is displaying "ERR" - it pulses on the display between that and OFF or whatever is being displayed - there's no # in front of it so it seems not anything to do with my zones - the manual says it could be radio interference on the smartport? Would it pulse like that if so? The smartport is just on the other side of the garage wall, so less than a foot - this problem just started a few weeks ago - first time in the 4 years I've had the system. The wires seem firmly connected within the controller box.
@royblake80017 жыл бұрын
Thank you for your timely reply. One thing I did not mention is that I also have a solar synch attached to the Pro-C controller. The solar synch display is blank and I've tried taking the battery out, disconnecting its power leads, and pressing the 3 buttons but I've had no luck getting a display. I did not mention this in my first post as it didn't seem relevant to the situation based on the ERR documentation indicating something with the smartport only. I went ahead and disconnected the smartport wires first from the terminals and the Pro C display still pulsed Err. With the smartport wires still disconnected I then unhooked the solar synch's blue wire from the REM terminal - the display stopped showing the pulsing ERR. Does this mean the solar synch module is causing the issue? Just to clarify this is a professional installation from 2013 that I've had no issues with until today. The only individuals that access the box inside the garage are myself and the sprinkler service I use - they gave no indication of this problem when doing startup maintenance on it in mid May. I didn't notice the pulsing ERR and blank display on the solar synch until I attempted using it in June as we've received sufficient rain during that interval. The first solar synch originally installed did fail after 1 year and the sprinkler install company replaced with the current one, under their warranty. Do you have any further thoughts or suggestions?
@billsbarra14082 жыл бұрын
I recently bought a newly built home with a Hunter X-Core irrigation controller. I have set all of the parameters, no problem. The problem I am having is that each time the system runs it reduces the run time for all of the stations. I continually have to reset the run times. Is anyone else having this problem or know the fix? Thnh!
@Hunter_Industries2 жыл бұрын
If the Run Times are changing automatically it means you have a Solar Sync sensor with your X-Core controller. Please use this link to learn more about this sensor and how to use it. www.hunterindustries.com/support/solar-sync-introduction
@pradiify4 жыл бұрын
For some reason my sprinkler doesn't work everything looks fine on the Hunter display
@kamilahmer4 жыл бұрын
@@Hunter_Industries .
@wheresoverholt61308 жыл бұрын
I get the programming, my question is that none has answered yet lol is, HOW DO I KNOW WHAT ZONE/STATION (A,B,C,D) IS FOR WHICH PART OF MY YARD!!??? I BOUGHT THIS HOUSE 'AS IS'. The landscaper/builder never communicated those stations with me! In one part of the house are my trees, the other part of the house are my girlfriend's flower bed. I ask also cause there must be renters of homes and owners need to communicate this to people!!!!!!!
@gretesklarchuk39382 жыл бұрын
seasonal adjustment changes on its own
@Hunter_Industries2 жыл бұрын
Thanks for watching!
@deborahsmith72792 жыл бұрын
How to turn delay display off
@Hunter_Industries2 жыл бұрын
Good question about the delay feature. Use the link below to learn how to get into the advanced feature Delay setting. You would reduce the delay to 0 if you want it off with the minus button when you are in that setting. www.hunterindustries.com/support/pro-c-removing-delay-between-stations
@magnogreato6 жыл бұрын
why are there not any P-Errors, or other L errors or # errors...the items talked now are pretty obvious to troubleshoot....get to the real problems.