Duromax XP13000EH running 5 Ton a/c on 500 gallon propane tank MUST WATCH - Part 2

  Рет қаралды 7,012

WRASSE REEF CHANNEL

WRASSE REEF CHANNEL

Күн бұрын

Link to PART 1: • Duromax XP13000EH on 5...
Link to PART 3: • Duromax XP13000EH runn...

Пікірлер: 18
@philliphall5198
@philliphall5198 Ай бұрын
Having a 500 gallon tank on a trailer is best practice for a generator 😊😊😊 Bet a lot of people in Houston would agree 😊
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Ай бұрын
@philliphall5198 I bet! I feel for you all in Houston or any Hurricane prone area!!!!
@PeterLawton
@PeterLawton Жыл бұрын
Good info. If I were change one thing, it would be to not use the "Dizzy Cam" recording style any more. Tripods are cheap.
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Жыл бұрын
I agree....it's on my list!
@chrismartin2746
@chrismartin2746 Жыл бұрын
FYI. Check with A/C mfgr regarding Total Harmonic Distortion. Our 2020 York A/C needs current with less than 5% distortion. More than that can damage the A/C. Other electronic appliances may also need the same level of clean current. Durmax generators have a 12-20% level fo THD.
@scottloo4118
@scottloo4118 Жыл бұрын
Did you need to use any sort of surge protection?
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Жыл бұрын
Hi there! Not on the generator itself, but all devices in our house has surge protectors on them.
@tonycloseukreef3799
@tonycloseukreef3799 Жыл бұрын
Great video luckily in the UK we don't need backup generator tank looking fabulous 🐠😍
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Жыл бұрын
Thanks! You are lucky....I live where we don't need it often, but rather have it and not need it, than need it and not have it! 😉
@mimounaoulghazi
@mimounaoulghazi Жыл бұрын
👍👍
@gordiehattrick
@gordiehattrick Ай бұрын
Do you have a Soft Start on the AC unit? With an LRA of 144, I'm shocked it didn't pop the generator circuit breaker. The Duromax XP13000 only outputs a little over 41 running AMP's, the initial startup on your AC is 144 AMP's! I have the same generator and a 3.5 ton AC unit. It pops the breaker on AC startup. The LRA on my condenser is 112. I'm installing a Micro-Air Soft Start that should bring the initial in rush of current down to 35-40 AMP's on startup.
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Ай бұрын
Nope we don't have a soft start on our AC, last summer replaced both the furnace and AC at the same time. We have used it several times and it never popped the circuit breaker. It runs the whole house, most importantly the AC and my fish tank. No issues...and a whole lot cheaper than a Gernerax. We just had to hire a electrician to wire both electrical panels, because we run two 200 amp panels, but we only backfeed one panel.
@js7447
@js7447 Ай бұрын
​@@WRASSEREEFCHANNELWOW! With a Locked Rotor Amperage of 144 AMP's I'm surprised the generator breaker doesn't trip. It's only a momentary spike but still, it's over 3 times the rated generator amperage output!
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Ай бұрын
@@js7447 Our new AC is a 5 ton unit.....so maybe that makes a difference?!
@FeedmeSeymore
@FeedmeSeymore Ай бұрын
Wow is right! I would not have believed it if I hadn’t seen it. At 13000W peak capacity, the generator should only be able to supply about 54A. The 27.1 RLA means the unit draws 6500W to run. If max running watts is 10,500W, that leaves about 4000W to run everything else. However my understanding on these portable generators is to not exceed 80% of max running watts for prolonged periods (8400W) so that should leave about 1900W. You must be real happy to be able to run that AC!
@WRASSEREEFCHANNEL
@WRASSEREEFCHANNEL Ай бұрын
@@FeedmeSeymore I am totally happy that runs the AC! Especially the fish tank! LOL!
@jameschuke4104
@jameschuke4104 Ай бұрын
People always trying to re invent the wheel leave it alone
Can I run central A/C on Backup Generator Power?
5:43
Jack of All Trades
Рет қаралды 47 М.
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
123 GO! Houseによる偽の舌ドッキリ 😂👅
00:20
123 GO! HOUSE Japanese
Рет қаралды 6 МЛН
PEDRO PEDRO INSIDEOUT
00:10
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 10 МЛН
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 22 МЛН
DuroMax Home Power Backup Questions Video
11:00
DuroMax Power Equipment
Рет қаралды 19 М.
Cheap vs. Expensive Generator (Surprising Results)
25:49
Ambition Strikes
Рет қаралды 634 М.
DuroMax XP13000EH Generator Connected  to 250 Gallon Propane Tank
11:26
The Complete Propane Tank Sizes Guide
8:10
Great Valley Propane
Рет қаралды 193 М.
DuroMax XP13000EH Generator Review - Watch before you buy!
9:38
Naomi Stephens
Рет қаралды 11 М.
Generator for the house - Dual fuel whole house system
9:47
BigRedFishDad
Рет қаралды 248 М.
Home Backup Generator Duro Max XP13000EH
8:07
Frank Leisner
Рет қаралды 23 М.
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45