Earth electrode testing the proper way

  Рет қаралды 9,940

Mike Page

Mike Page

8 ай бұрын

In this video im back at the new service i recently fitted to conduct some proper earth electrode tests after previously jsut getting a earth fault loop impeadance result.
Earth Electrode testing with Paul Meenan:
• Testing a ConduDisc ea...
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
M Y W E B S I T E ⚡
residualcurrent.com/
M Y L O A D O U T 🛠️
residualcurrent.com/pages/loa...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk/?ref=4s3760y77o - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/?ref=RESIDUAL - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualcurrent
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/ZM86U2jjG/
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

Пікірлер: 39
@walseee
@walseee 8 ай бұрын
Where you been, we’ve missed you 😢
@Jake_Baker_Electrician1997
@Jake_Baker_Electrician1997 8 ай бұрын
Not a test I have had to undertake often, so this video will be a massive help to refresh the memory in future! You’re probably the best KZfaq Spark for informative content that looks awesome 👌 watched all your content and I’ve adopted a lot of the things you do into my own skill set which has helped me massively as an apprentice!
@TheHomeent
@TheHomeent 8 ай бұрын
Once again you nailed it. Always great videos. Full of information and the job done properly, no shortcuts.
@bramcoteelectrical1088
@bramcoteelectrical1088 8 ай бұрын
good to see as not many have done the 3 lead test or understand how to carry out this testing good video thanks
@paulstimpson8977
@paulstimpson8977 4 күн бұрын
I went with a cheaper tester as testing can be done with as you say by 3 methods, my luck get called to a TT install with a fault no power (Fuse pulled) and what looks like a disconnected Earth Rod! Didn't do the job in the end because no one knew who pulled the fuse or why and other issues! But I would have been in a pickle not being able to prove the TT earth was sound prior to the Supplier (DNO had no contact and stated that without knowing why the fuse was pulled they would not reinstate) coming out and who knows when they would turn up! Would probably need to be there when they came.
@fredflintstone1
@fredflintstone1 8 ай бұрын
years ago I used a wheatstone bridge meter for testing earth rods in hospitals
@johnward5006
@johnward5006 8 ай бұрын
Top man! You nailed it and that's a plumber commenting!
@DarkShadowedOne
@DarkShadowedOne 8 ай бұрын
Only just had to use this sort of tester at work this week for doing lightning protection testing. Lucky you have a nice open area to drive your test stakes in for your video
@sergiofernandez3725
@sergiofernandez3725 8 ай бұрын
Great explanation Mike
@Engineer-Samibress
@Engineer-Samibress 8 ай бұрын
Thanks for your time
@fje1948
@fje1948 8 ай бұрын
Excellent video - you do thing’s properly! Many thanks Mike.
@rattlehead85
@rattlehead85 8 ай бұрын
Fantastic video mate. Good reference material to go back on as this test is not one of the common ones and not many sparks could tell you how to do it. Calculations towards the end got a bit complex with the percentage deviation but how you explained it was great. Well done fella. Enjoy your content. 👍🏻👍🏻👍🏻
@e5Group
@e5Group 8 ай бұрын
coming along nicely
@tincanpete
@tincanpete 8 ай бұрын
interesting and helpful video... thanks!!
@corymac
@corymac 8 ай бұрын
Great job! 👍🏼
@lowrybrock8272
@lowrybrock8272 8 ай бұрын
That’s really interesting stuff. And go ahead and admit it, those were your toys weren’t they? Good to see you back! Be safe out there!
@iosebbegiashvili8145
@iosebbegiashvili8145 3 ай бұрын
previously with efli test you have almost similar readings ,i wonder ,is it worthy to do potential fall test as well?
@flint1982769
@flint1982769 8 ай бұрын
Great video!!
@alantowler9430
@alantowler9430 8 ай бұрын
excellent video.
@chrismason3341
@chrismason3341 Ай бұрын
Dno or supplier still not been out to reseal?
@SpikesMavic
@SpikesMavic 29 күн бұрын
But if the test Spikes are into dry ground, what will that measure ?
@maximuspareo
@maximuspareo 8 ай бұрын
It is ok 16 ohm ??? In my country we need 4 ohm for normal and 1 ohm for + lighting protection .
@adriatikkrasniqi1453
@adriatikkrasniqi1453 8 ай бұрын
How did you do calculations is 2.2 percentage. To ne work out 3.8 percentage..,
@vioreltanasa988
@vioreltanasa988 4 ай бұрын
What are you doing when you measure to a industrial place and you cannot disconnect earth because are a engine in process
@martijn7924
@martijn7924 29 күн бұрын
Look up stakeless and selective earth testing. If money is not an issue, see earth clamp meters as well.
@Riley_Jarvis_the_sparky
@Riley_Jarvis_the_sparky 7 ай бұрын
Lovely video bud keep it up 👍
@residualcurrent
@residualcurrent 7 ай бұрын
Thanks, will do!
@electricalservicesmaroc
@electricalservicesmaroc 8 ай бұрын
Hello man ❤❤❤🎉🎉🎉
@vioreltanasa988
@vioreltanasa988 4 ай бұрын
Rezistence should be under 4 ohms for civil and industrial ,and under 2 ohms for farming 😢
@vioreltanasa988
@vioreltanasa988 4 ай бұрын
You have only 1 electrode must be 3 in star connected
@adriatikkrasniqi1453
@adriatikkrasniqi1453 8 ай бұрын
I done the calculations 3.8 percentage not 2.2 percentage…
@fje1948
@fje1948 8 ай бұрын
@adriatikkrasniqi1453 Hi. Can you please provide an analysis of your calculations - Thank you. I make it: max deviation from average 16.56 - 16.20 = 0.36 then (100/16.56) x 0.36 = 2.17% which is close to Mike’s result!
@adriatikkrasniqi1453
@adriatikkrasniqi1453 8 ай бұрын
@@fje1948 you have to do the highest minus average taken from 3 reading then divide by the highest + - 5% but not more then that…
@fje1948
@fje1948 8 ай бұрын
⁠@@adriatikkrasniqi1453 Thank you for your swift reply. Using Mikes readings: Highest 16.84 - Average 16.56 ---------- 0.28 Further using your wording: ‘Then divide by the highest’ 0.28/16.84=0.01662708 ??????????? Your detailed calculations using Mikes readings would be appreciated - Many Thanks.
@adriatikkrasniqi1453
@adriatikkrasniqi1453 8 ай бұрын
@@fje1948 than times by 100 %
@adriatikkrasniqi1453
@adriatikkrasniqi1453 8 ай бұрын
@@fje1948 I the end of the day is good to contribute with this calculation for us as learners maybe I am wrong Mike calculation I could be right I don’t but he to explain the calculation.
@vioreltanasa988
@vioreltanasa988 4 ай бұрын
I am not satisfied with this
@vioreltanasa988
@vioreltanasa988 4 ай бұрын
Electrods sh
@picklenipples
@picklenipples 8 ай бұрын
awesome vid!
Installing an earth Rod - New TT Supply
30:36
Mike Page
Рет қаралды 40 М.
What's in my van 2024? - Electricians Van Tour
25:41
Mike Page
Рет қаралды 10 М.
Joven bailarín noquea a ladrón de un golpe #nmas #shorts
00:17
КАРМАНЧИК 2 СЕЗОН 5 СЕРИЯ
27:21
Inter Production
Рет қаралды 594 М.
Sprinting with More and More Money
00:29
MrBeast
Рет қаралды 101 МЛН
Earth Electrodes - 3 Wire Testing Example (Part 3)
19:10
John Ward
Рет қаралды 39 М.
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 640 М.
Earth Fault Loop Impedance
1:49
Master Electricians New Zealand
Рет қаралды 24 М.
HOW TO PREFORM EARTH RESISTANCE TEST
14:36
rictor rictor
Рет қаралды 234 М.
Earth fault loop impedance testing - ZS
9:32
Mike Page
Рет қаралды 12 М.
Earth Electrodes Part 2 - Installing, Loop Impedance Testing
12:03
Earth Electrodes Part 1
11:48
John Ward
Рет қаралды 98 М.
What percentage of charge is on your phone now? #entertainment
0:14
С Какой Высоты Разобьётся NOKIA3310 ?!😳
0:43
iPhone 12 socket cleaning #fixit
0:30
Tamar DB (mt)
Рет қаралды 13 МЛН