Earth Neutral Bond

  Рет қаралды 29,956

Sunsynk

Sunsynk

Жыл бұрын

The training video shows a neutral bond with a 3.6 kW inverter.
The earth-neutral bond is important when used as a UPS because it changes the classification of the Inverter from a class 2 to a class 1 device

Пікірлер: 57
@truplayez513
@truplayez513 Жыл бұрын
These inverters should come with an internal relay for earth bond. It's ridiculous that it must be wired in after
@yusufkarriem1074
@yusufkarriem1074 Жыл бұрын
Any reason why these inverters are not manufactured with a neutral bond relay internal
@sharkfinn6469
@sharkfinn6469 Жыл бұрын
Because they rubbish. Deye is the same but why does it work better?
@r.h.5985
@r.h.5985 Жыл бұрын
Hi. I'm sorry but I don't understand why a tutorial video is done without "purely for demo purposes". It would be great if you voukd do a tutorial that shows exactly what should be done. I.e. useing an inline fuse in the demonstration. What size? Useing the correct cable? Again what size? I find the videos informative but I'm always left wondering more than I started. Maybe try and do the videos exactly as it should be done. That would be very helpful. Thank you
@1001stmonkey
@1001stmonkey Жыл бұрын
He was only referring to the tiny little wires "purely for demo" LOL The video does show exactly what to be done.
@truplayez513
@truplayez513 Жыл бұрын
That's one thing I like about Victron and that's all . They have an internal earth bond relay, fantastic
@bassplaya69er
@bassplaya69er 9 ай бұрын
at what price? is it worth paying thousands more for?
@freddiewithers9617
@freddiewithers9617 Жыл бұрын
I think the 5kw ECCO has the same contact configuration as well. It's really annoying though as this requires a NC contactor which will constantly dissipate ~4W. Why there is no 230V output which activates a NO contactor or better integrate a N-E bond is weird. The manual is inconsistent with this video (Page 17).
@jcschwarb
@jcschwarb Жыл бұрын
Hi Keith. Great video! When running parallel inverters, is it okay for each inverter to apply a Neutral-Ground bond in each inverter? My concern is arc fault, possible ground loops. My inverters apply NG bond when in DC modes (battery or PV), but not when AC input is energized as it is assumed (in the USA) that the NG bond is in the first means of disconnect after the meter. The vendor refuses to answer my questions/concern. Thanks in advance! -Jay
@capailldubh
@capailldubh Жыл бұрын
So this is what we need to run safely totally off-grid? Best of luck with the op Keith. Got a hip done a couple of years ago. Great job.
@paulfreeman5386
@paulfreeman5386 Жыл бұрын
👀
@Dino_Bianchi
@Dino_Bianchi 9 ай бұрын
How to choose the contactor? How many amperes must the contacts carry for a 8kW inverter: is just a reference to the earth or they should be rated at 40 A?
@lulmaster635
@lulmaster635 6 ай бұрын
i have a question ,, do we need to bond the smart load neutral as well or just load side neutral earth bonding is enough?
@steveharvey6841
@steveharvey6841 Жыл бұрын
Hi Keith good luck with the op! Please can you answer my question from your book titled 'Earth bonding for dummies' I have a 8Kw inverter with 2 X 5.5 Kw batteries all working perfectly WITHOUT earth bonding, (No Panels, system used for load shedding) If I connect a relay strictly as per your instructions my ELU trips what am I missing????
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
ELU?
@MHBGT
@MHBGT Жыл бұрын
​@@tanishqbhaiji103 Earth Leakage Unit. Basically the RCD, residual current detection device.
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
@@MHBGT you need to setup the delay time in the settings, as the relay is slow to switch and is triggering the RCD. I believe he has a video on this.
@houseofancients
@houseofancients Жыл бұрын
good luck on your operation keitj
@nicoverhoef7259
@nicoverhoef7259 7 ай бұрын
With "signal island mode" one can use a normally open (NO) neutral earth bonding relay.
@andrekhoury6252
@andrekhoury6252 10 ай бұрын
so i wonder why u dont put it externally the contactor coil on grid line so will NO will be NC and earth to neutral will bond when no grid its open
@jonerasmus9399
@jonerasmus9399 Жыл бұрын
Is there a circuit diagram available for this neutral and earth bond using a contactor . It's hard to see on the video what wires were put where
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
I could make one by hand if you want?
@MSmith4X4
@MSmith4X4 Жыл бұрын
@@tanishqbhaiji103 YES PLEASE !!!!
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
@@MSmith4X4 my drawing is bad and I will need some time but I will do it
@MHBGT
@MHBGT Жыл бұрын
​@@tanishqbhaiji103 still waiting for your diagram. 😂
@exshvezdickou
@exshvezdickou Жыл бұрын
What is the reason why this relay is not integrated? Do I need to add the same for 10kW three phase inverters?
@tambo22003
@tambo22003 Жыл бұрын
yes.
@exshvezdickou
@exshvezdickou Жыл бұрын
@@tambo22003 actually no. 10kW inverters for EU market have this feature integrated, you can find the note in manual near schematics.
@tambo22003
@tambo22003 Жыл бұрын
@@exshvezdickou Nice to see a different variant on a different Market. :D
@bassplaya69er
@bassplaya69er 9 ай бұрын
@@tambo22003 other markets offten dont bother with earth
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
How much panels can the 6Kw single phase take on 1 MPPT trackers without the other having any?
@tambo22003
@tambo22003 Жыл бұрын
depending on the model, 6500W or 7800W worth of solar panels. A commerical pannel is about 300W on a good day, so about 20 per MPPT.
@tanishqbhaiji103
@tanishqbhaiji103 Жыл бұрын
@@tambo22003 so like 100% input imbalance?
@tambo22003
@tambo22003 Жыл бұрын
@@tanishqbhaiji103 The MPPT's are independent. Do what ever you want, just don't over the voltage limit.
@dannyjose6005
@dannyjose6005 Жыл бұрын
To Steve and Keith, if I may, is your grid neutral and load neutral bonded at any point? My installation of 2x 5kw with 11kw/ 2 battery would trip the mains with a clear short/ arc on the master Inverter grid terminals about 30sec switched on for the first time. After a thorough inspection with the supplier technician, we found the Inverter load neutral terminal and grid live terminal ring out. AT THIS POINT THE SYSTEM WAS CONNECTED WITH THE CT and no external neutral bonding. I must mention the system worked fine on battery back up prior the dead short, ran a load @1.3kw the issue arrised -+ 30 sec after switching grid On. To my surprise during the inspection the technician suggested/ instructed me to bond output and input neutral BEFORE THE E/L and disconnect CT. According to his words " the is a build in check CT for feed back just get the Zero export on settings " Currently running and waiting on the replacement unit. My friend at the Muni was not happy when I told h this as we both know feed back or reference neutral is dangerous to when working on MV lines . I would like to rectify this but I'm a bit puzzled with the bonding story. Please assist where possible. Thanks
@meinderthoving
@meinderthoving Жыл бұрын
I don't understand your comment, but Keith did a better explanation here:kzfaq.info/get/bejne/o7eCaLl8ydLXmHk.html&ab_channel=Sunsynk
@Dc_tech386
@Dc_tech386 Жыл бұрын
So that’s a high frequency inverter right no iron core heavy transformer
@houseofancients
@houseofancients Жыл бұрын
this is only for the single phase, how about the 3 phase systems ?
@tambo22003
@tambo22003 Жыл бұрын
same, earth bond is needed.
@garethevans1629
@garethevans1629 Жыл бұрын
Hi Keith, I had a 10Kw Sunsynk Inverter and Battery system (2 x5kw paralleled) installed for my house in South Africa. After a week one of the inverters failed and had something burning smell coming from it. The company that installed the system replaced the inverter as they thought it was a faulty inverter. almost two weeks later the new inverter failed exactly the same. The company that installed the inverter and the supplier came to my property to investigate. They said let's try get a bigger inverter so they removed both inverters and installed the 16kwa. Not even two weeks old the new 16kw inverter has failed and has burning smell coming from it! I have spent hundred of thousands of Rands and it keeps failing!
@sunsynk
@sunsynk Жыл бұрын
What is the site name
@sunsynk
@sunsynk Жыл бұрын
Sounds like a mismatch on the solar panels. If you give me the site name I can check everything
@garethevans1629
@garethevans1629 Жыл бұрын
@@sunsynk The panels are all the same. they are Canadian Solar 450W panels, 12 of them. Site is in Kloof, South Africa
@munniknieuwoudt1377
@munniknieuwoudt1377 Жыл бұрын
I had the same problem. Blown 3 5kw inverters in 3 weeks time. Also burn smell. There was a damage light circuit cable. They used a earth as a neutral, but i am not sure if that was the reason to blow up the inverters. I have taken the whole installation apart. Still dont have a answer.
@munniknieuwoudt1377
@munniknieuwoudt1377 Жыл бұрын
I have 8 x 455W Canadian Solar panels. Megger and tested them all but cant find any fault. I have taken then down and going to test them with a 5kw Mecer inverter and see what happens. I think its the panels causing the problem.
@crisssimpson7347
@crisssimpson7347 Жыл бұрын
what about 16kw as there is no ats or dry contact
@martinvanbiljon4596
@martinvanbiljon4596 Жыл бұрын
It also has a dry contact like the 3.6kw. Which is the ats signal. Unfortumately i dont know what to do if there is a generator on site as well...
@greenpro-greenproconsultin7420
@greenpro-greenproconsultin7420 Жыл бұрын
Why use the inverter to power a relay? Simply wire a relay into the DB.
@truplayez513
@truplayez513 Жыл бұрын
Check all the diy guys in comment's. You not going to be able to buy anymore from suppliers because you mess it up and then lodge warranty claims
@Radu-11-11
@Radu-11-11 3 ай бұрын
For a sistem with 12 kw recomand deye 12 kw inverter hibrid / 3 inverter I have electric heating vaillant 18 kw
@MrTrojantrdll
@MrTrojantrdll Жыл бұрын
Thanx
@guy7gsa
@guy7gsa Жыл бұрын
Good video, but only 360p
@NowWeComeAlive
@NowWeComeAlive Жыл бұрын
Normally Closed Contactor Terminal 5 is a neutral for the contactor coil Live wire from load live feeds the contactor coil A neutral from terminal 6 to the neutral for load which also goes to the top of the contactor An earth from the earth bar to the bottom of the contactor.
@andriusst
@andriusst 5 ай бұрын
This this a very talented and technically skilled individual no doubt. However it is very apparent that there has been no preparation what so ever. Missing sockets, incorrect cables, repeating things like for demo purposes, etc etc. Minimum effort never come across as professional and just winging it will never be as clear and understandable as going from the script.
@shaunchetty4223
@shaunchetty4223 Жыл бұрын
That's why Victron is a superior inverter It has a built in programmable relay to bond output neutral to earth No additional wiring and relays required as per your video
@bassplaya69er
@bassplaya69er 9 ай бұрын
is that worth paying thousands extra?
Grounding & Bonding For Solar Inverters: Part 1: Basics
12:38
Reel Clear Media
Рет қаралды 10 М.
RCDs Explained | Sunsynk Training Video
13:25
Sunsynk
Рет қаралды 9 М.
I Need Your Help..
00:33
Stokes Twins
Рет қаралды 131 МЛН
What is the Difference Between Grounding, Bonding and Neutral?
15:15
Sunsynk Inverter Training (Basic)
1:00:17
Tripple Hydro and Energy
Рет қаралды 49 М.
Using a #generator with a #Sunsynk hybrid inverter
11:23
Sunsynk
Рет қаралды 34 М.
Brief introduction to Battery systems
23:34
Sunsynk
Рет қаралды 32 М.
Ground Neutral and Hot wires explained - electrical engineering grounding ground fault
11:13
Grounding and Bonding
8:01
schulerruler
Рет қаралды 660 М.
Карточка Зарядка 📱 ( @ArshSoni )
0:23
EpicShortsRussia
Рет қаралды 197 М.
Выложил СВОЙ АЙФОН НА АВИТО #shorts
0:42
Дмитрий Левандовский
Рет қаралды 1,1 МЛН
XL-Power Best For Audio Call 📞 Mobile 📱
0:42
Tech Official
Рет қаралды 772 М.
What percentage of charge is on your phone now? #entertainment
0:14
iPhone 15 Pro vs Samsung s24🤣 #shorts
0:10
Tech Tonics
Рет қаралды 9 МЛН