Earthing AC Dc for 20kw Ongrid System in Lahore.

  Рет қаралды 6,562

Zeeshan Tariq

Zeeshan Tariq

3 жыл бұрын

/ zeeshansolarsystem
#solarpanel
#tesla #earthing #ac #dc
Are you Tired.....
Do you have 3 Phase Electricity Connection ????
if yes then Get your Complete Solution and Save upto 💯 %
Short payback time and Top Quality Products.
System ratings : #3kw #5KW #10KW #15KW #20KW #50KW.....
System Specs:-
✓ Solar panels = 435 Watt LONGI, Jinko, Trina, JA Solar Mono perc, 25 years performance warranty
✓ Inverter = Solis / JFY / Growat, 5 years Warranty
✓ Galvanized Structure, branded Wires and Breakers…
✓ Earthing, Surge Arrestor, Disconnect Switch
✓ Complete installation with after Sale Services
#Netmetering #Zeeshan Solar #Longi #Tesla #Solis #solarmax #Maxpower # #Jinko #Zerobilling #Solar
Call now : +923008424073 Save upto 70% with Hybrid System and Zero bill with Ongrid Systems.
Whatsapp : 03008424073
Address: 118 A, Ali Block New Garden town, Lahore
@ Zeeshan Solar Solutions
#Zeeshan solar #netmetering #zerobilling #Pakistan

Пікірлер: 35
@user-yh5lj4wk6u
@user-yh5lj4wk6u 6 ай бұрын
Appreciate the work quality with evidence pictorial
@ASIFKHAN-ui7jp
@ASIFKHAN-ui7jp Жыл бұрын
If I am not mistaken NEC and NFPA standards dictate common earthing not AC and DC earth separate. In case of Lightning discharge due to different potential gradient on ground, different earthing may result equipment damage or fire. What reason NEPRA give to have them separated. Please Explain.
@HibaTradingSMCPVTLtd
@HibaTradingSMCPVTLtd 3 жыл бұрын
Masha Allah Zeeshan sb zabardast
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Humble bhai bohat shukria
@pakelectric797
@pakelectric797 6 ай бұрын
Earth ki hamesha resistance Leni Hoti ha Jo earth pit tester se hi multi TB Jake earth ki tasali Hoti ha
@faisalkhan6079
@faisalkhan6079 3 жыл бұрын
very good sir.
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Thanks brother
@user-bw9yf6xm2h
@user-bw9yf6xm2h 4 ай бұрын
AOA SIR agr wapda ka transformers earth na howa hoo to is pr 110v aa jatay hai
@anasmajeed2958
@anasmajeed2958 Ай бұрын
Aap ny pipe q insert kia ha ya baad mein pipe nikaal lia tha??
@usmansarwar8472
@usmansarwar8472 3 жыл бұрын
Mashallah very nice
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
جزاک اللہ
@usmansarwar8472
@usmansarwar8472 3 жыл бұрын
Sir I also want this type of earthing at my home please..
@moondigitall
@moondigitall 3 жыл бұрын
Very Good
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Thanks brother
@mowaisshahid
@mowaisshahid 7 ай бұрын
30 ft bore kis lye? Zameen sy pani nikalna hy kia? 🤣
@madil6852
@madil6852 2 ай бұрын
Earthing meter se check karwa do bayi
@asifiqbal-uc5yy
@asifiqbal-uc5yy 2 жыл бұрын
dear Zeeshan Solar Solutions do you have any calculation of earth pit that this EP how much current can disipate more over can you please explore the details how much is depth of bore and either this is chemical earthing.
@chooranchatni5001
@chooranchatni5001 Жыл бұрын
sir mery ghar 1.6 kv ka inverter ha.. 6 solar panel hn 180 watt ki..kia muje earthing ki zarorat ha
@hafizshaban589
@hafizshaban589 2 жыл бұрын
Please tell why we using AC and DC earthing
@rahimullahkhan1974
@rahimullahkhan1974 2 жыл бұрын
Sir bore kiliyey konsa equipment estimaal kiya hey aur hard areas kiliyey kitna bore recommend kartey hain jahan water table low ho?
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 2 жыл бұрын
Watch again video i have tell all details.
@hafizshaban589
@hafizshaban589 2 жыл бұрын
Please tell why we are using DC earthing and AC earthing. And can we use single earthing both for AC and DC
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 2 жыл бұрын
As per nepra rules both ac and dc must be separate
@hafizshaban589
@hafizshaban589 2 жыл бұрын
Please tell what should Ohms values for AC & DC earthing
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 2 жыл бұрын
Less then 5 ohms as per nepra rules
@maqsoodhashmi7863
@maqsoodhashmi7863 Жыл бұрын
what was the readings in ohms? I have not seen earthing rod voltage being measured before? Why not do a proper earth test to prove impedance?
@blackmouse2248
@blackmouse2248 3 жыл бұрын
How much lenght of pvc pipe used in. 30ft earthing bore?
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
13 feet 2 inches
@faisalkhan6079
@faisalkhan6079 3 жыл бұрын
sir ye aik pv panels earth dcv ka earth hy aur dosra AC voltage ka earth hy? ky 3phase ky lye alag alag phase ky lye earht hy?
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Ac earth separate and dc earth is separate its minor difference when water level increase automatically balanced for that earth
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Only 1 earth is required for single phase or 3 phase as per nepra rules 6 ohms is okay
@abdulbaloch3700
@abdulbaloch3700 3 жыл бұрын
Dear are AC and DC earthing common? I think your earthing way is weak because of Pvc pipe
@zeeshansolarsolutions2145
@zeeshansolarsolutions2145 3 жыл бұрын
Both are different and earth wire is install in pvc pipe because of beauty of work and safety my dear.
@madil6852
@madil6852 2 ай бұрын
Ye meter use ni hota bayi maafi de do
Solar Plant Earthing | Chemical Earthing | LA , AC, DC earthing
18:59
Sustainable Every Day
Рет қаралды 213 М.
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 25 МЛН
Опасность фирменной зарядки Apple
00:57
SuperCrastan
Рет қаралды 12 МЛН
小蚂蚁被感动了!火影忍者 #佐助 #家庭
00:54
火影忍者一家
Рет қаралды 28 МЛН
Grounding Solar PV System, DIY, on Pallets
4:47
DavidPoz
Рет қаралды 149 М.
Perfect EARTHING for HOME | AC and DC bores | Solar Installation
12:10
EARTHING of My SOLAR SYSTEM | Amin Hafeez
13:17
Amin Hafeez
Рет қаралды 15 М.
Depth of Electrical Earthing (urdu , Hindi)
7:38
Unicorn Energy Systems
Рет қаралды 74 М.
DC and AC Earthing for Solar System
6:35
Smart Solar
Рет қаралды 47 М.
Importance of Electrical Earthing and its Necessity (In Urdu)
6:27
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 25 МЛН