EG4 6000XP off grid Inverter long term Review | 8000W PV | 480V VOC | 48V 120/240V Split Phase

  Рет қаралды 12,062

TGBATG

TGBATG

Күн бұрын

6000xp inverter: signaturesolar.com/eg4-6000xp...
- Links are affiliate links to authorized distributors
-------------------------------------------------------------------
Features
The EG4 6000XP is a cutting-edge 48V split-phase, off-grid inverter and charger, designed to revolutionize your energy needs. With an impressive 8kW of PV input capacity and an efficient 6kW continuous power output, it also serves as a battery 140A charger. What sets it apart is its scalability - you can parallel up to 16 units for an impressive 96kWs of output power while controlling multiple stations and units seamlessly using our advanced EG4 monitoring software.
Performance Components
6000W rated output power
Parallel up to 16 units for 96kWs of output power
Built-in Switchgear for reduced installation costs and enhanced safety
Save up to $300 with built-in breakers, disconnects and more!
Transformer-Free Design
Dedicated Generator Connection
Inverter, AC Charger, and Solar Charge Controller
All-In-One
Everything needed to get started
Simple to install, easy to manage
Manages power from energy storage systems, and grid simultaneously
120/240V split phase
Efficiency
MPPT Efficiency 99%
Outperforms similar-sized competitors by an average of 7%
Battery Charging Efficiency 93%
Battery Discharging Efficiency 93%
50W Idle Consumption (with battery)
Monitoring
EG4 Monitoring App
Google Play
App Store
Wi-Fi/4G/LAN
RS485
Comprehensive Certifications
UL 1741
Ingress Protection Rating: IP20
-------------------------------------------------------------------
Timecode
0:00 - EG4 6000xp Unboxing
2:18 - EG4 6000xp specs
4:38 - 6000xp Front Panel
5:04 - 6000xp grid connection
5:30 - 6000xp generator boost bypass
7:46 - 6000xp wifi
8:23 - 6000xp screen
9:55 - 6000xp connections
10:55 - 6000xp new vs old
14:22 - 6000xp load center
18:43 - Solar powered 24k minisplit
19:06 - 6000xp overview
-------------------------------------------------------------------
Contact us: contactus@tgbatg.com
-------------------------------------------------------------------
1511090

Пікірлер: 52
@Dobbs6651
@Dobbs6651 19 күн бұрын
NEVER USE HIGHER AMP BREAKER FOR CABLE THAT CAN NOT HANDLE THE LOAD. Braerks are meant to cut power before the cable melts. You put a 50 amp break on a cable that does not have the proper gauge. You now have the possibility of a fire.
@tlteal
@tlteal 27 күн бұрын
Great video. New sub. thank you --- been looking at the EG4 6000 XP as I grow my solar array
@tgbatg
@tgbatg 25 күн бұрын
Welcome aboard!
@daddio7249
@daddio7249 24 күн бұрын
I got my EG4 system back in last August. It came with the trouble plagued 6500EXs. I traded them in for two 6000XPs. I got used to the lights flickering but they made the UPS on my computer and RV system click so much I had to remove those. That and the 6500EXs have to be phased to get 240v. If one went out I would not be able to run my deep well pump. The 6000XPs each make 240v and with two paralleled they can support each other and keep voltage fluctuations control ed.
@oldpretender1268
@oldpretender1268 27 күн бұрын
Thanks for this. Good review. I just installed two in parallel with 40kWh LiTime battery bank and 8kW array. I use it to power a critical loads panel to reduce PG&E cost (currently $0.41/kWh). I also have some GroWatts powering my well pump, but these inverters are working like champs. New subscriber.
@tgbatg
@tgbatg 25 күн бұрын
Thanks, and welcome aboard
@Kenriko
@Kenriko 9 күн бұрын
WTF it’s 12c per KWH in Texas. Glad I don’t live in CA anymore.
@Rightgear84
@Rightgear84 5 сағат бұрын
@@Kenriko It's .68 per KWH on my plan in SoCal from 4 PM to 9 PM from June 1st till the end of Summer. It's BS I tell ya.
@tylerphom
@tylerphom 9 күн бұрын
❤video
@nschubach
@nschubach Ай бұрын
You may want to mask over your wifi dongle serial and pin since that allows people to add your device to their control website...
@tgbatg
@tgbatg Ай бұрын
Thanks for the tip
@An_Appeal_To_Heaven
@An_Appeal_To_Heaven 27 күн бұрын
Shhhhhhh
@woolval52
@woolval52 12 күн бұрын
@@An_Appeal_To_Heaven LOL. "Nothing to see here, move along!"
@woolval52
@woolval52 12 күн бұрын
True. I was kinda surprised at how Signature Solar was able to log in and see my 6000XP.
@picobyte
@picobyte 29 күн бұрын
My victron inverter runs any load problemless. It has a proper transformer and AC filter to store that few joules our loads take when kicking in.
@picobyte
@picobyte 29 күн бұрын
We run our grid at 230/400V here in the Netherlands. Our connection does 27kW and when solar is going we can charge cars/batteries with 50kW. That's some serious juice.
@tgbatg
@tgbatg 29 күн бұрын
Yeah Victron makes good stuff.
@ry2456
@ry2456 29 күн бұрын
Yes they have quality equipment. I have used multipluses and currently have smaller charge controller and a 1200va phoenix inverter as a portable power source. For home use in the USA they are a pain If a person needs to meet code though. Not to mention some of their pc software is not up to modern UI standards. In the US parts need UL listing. Then finding listed bus bars, fusses, disconnects .........etc... This makes units like this appealing. If Victron built an all in one like the eg4 units but with their gear and got it listed they would get my attention.
@norsk54472
@norsk54472 Ай бұрын
a suggestion to use a plastic pen as a pointer and not a screwdriver. fumbling the screwdriver can get nasty. nice video and good work and review thanks
@tgbatg
@tgbatg Ай бұрын
Thanks for the tip!
@gmsgabaradama2009
@gmsgabaradama2009 25 күн бұрын
That bond needs to be done in your main service panel, but that’s only if you’re using it to power things in your house or else you could create a very dangerous situation with Power going to ground
@tgbatg
@tgbatg 25 күн бұрын
I’ll probably put it back in the main panel when rebuilding the system.
@rolandogonzalez1694
@rolandogonzalez1694 12 күн бұрын
What size are the grommets
@jamojones8217
@jamojones8217 19 күн бұрын
In the sub panel, can i run a 240 load out (well pump) along with a couple 120 circuits?
@makingstuff242
@makingstuff242 11 күн бұрын
yes
@jimgraham290
@jimgraham290 29 күн бұрын
It was my understanding that the breaker size for the inverter feed into the panel was 50 amps?
@tgbatg
@tgbatg 28 күн бұрын
Yeah 50 amp is good if you’re going to do ac bypass or generator boost. But in my application where I would never come across that I would really never exceed 25A (6000/240) for continuous load
@danslamusique
@danslamusique 21 күн бұрын
As long as you use 6g wire 50 is good. 40 would be better for 8g wire
@newbie101
@newbie101 Ай бұрын
How long will this inverter last?
@tgbatg
@tgbatg 29 күн бұрын
At least the length of the warranty…
@jkee6146
@jkee6146 8 күн бұрын
Toche!@@tgbatg
@AaronBrand
@AaronBrand 25 күн бұрын
What battery are you using?
@tgbatg
@tgbatg 25 күн бұрын
I’m using eg4 lifepower4 and solution batteries. signaturesolar.com/eg4-lifepower4-lithium-battery-48v-100ah/?ref=bkpkbxde And aolithium.com/products/51-2v-100ah-server-rack-lithium-lifepo4-battery
@solarcharging9743
@solarcharging9743 22 күн бұрын
This low cost transformerless inverter is OK for wimpy low surge loads, but it can't start a 6,000 Watt inductive load like a 6kW water pump or a 6kW AC unit.
@tgbatg
@tgbatg 20 күн бұрын
If you don’t need to start something like that, then it’s a good option
@GetReal77
@GetReal77 3 күн бұрын
You're full of crap, why an XP6000 can start the universe if need be...
@solarcharging9743
@solarcharging9743 3 күн бұрын
@@GetReal77 Dream on moron. The 6000XP can't even start a 6000 Watt inductive load without overloading. .
@solarcharging9743
@solarcharging9743 3 күн бұрын
@@GetReal77 Dream on fool. I've repeatedly asked SS and their affiliate advertisers to produce a video showing this low surge inverter starting a 6kW inductive load and so far, no show. And you know why? Because it can't. LOL! 🤣
@GetReal77
@GetReal77 3 күн бұрын
@@solarcharging9743 You are mistaken, an XP 6000 at full throttle will generate a black hole and destroy the entire planet. I wanted 2 Victron 5000's but they are not UL listed, then I was going to get a Schnieder 6848 but hear customer support is really lacking so I ended up with a EGboy. What about a SMA 6048 US or what do you recommend? No a HF will not do near what a good LF will do but the latest EG4 stuff is getting good reviews for what it is...
@solarcharging9743
@solarcharging9743 3 күн бұрын
Watch "6000xp is not UL9540 certified. YOU CANNOT LEGALLY install in the US along with solar panels" on KZfaq to learn why you might want to reconsider buying this inverter.
@bizzfo
@bizzfo 16 күн бұрын
You said not to touch anything in the panel then you go poking and touching everything with the screwdriver.
@quickquote1568
@quickquote1568 13 күн бұрын
The high frequency, 6000XP is not UL9540 certified. YOU CANNOT LEGALLY install this inverter in the US with solar panels, so you'll never get it permitted.
@quickquote1568
@quickquote1568 Ай бұрын
This low cost high frequency inverter doesn't even have an output transformer. Without an iron core, copper wound transformer to provide galvanic isolation, they typically only last 2-3 years. No thanks!
@diggerbrass
@diggerbrass 29 күн бұрын
Could you backup your claim by citing your source?
@prepsolar787
@prepsolar787 28 күн бұрын
well if that's the case that they only last 2-3 years. it will be under warranty since it comes with 5 year warranty. wich makes me wonder if your comment has any truth to it.
@An_Appeal_To_Heaven
@An_Appeal_To_Heaven 27 күн бұрын
Not this bot douche again...🙄
@quickquote1568
@quickquote1568 27 күн бұрын
@@prepsolar787 Search Google or KZfaq for the term EG4 6500EX fail if you have doubts about what I'm saying. Insofar as the 5 year warranty is concerned, why would you want to go to all the trouble of taking your inverter off the wall and pay to ship it back at year 2-3 to have it repaired under warranty? I know this to be true because I've been in the inverter repair business for over 24 years. High frequency, transformerless inverters simply don't last.
@quickquote1568
@quickquote1568 27 күн бұрын
@@diggerbrass I'm the source. I have been in the inverter repair industry for over 24 years and have repaired thousands of inverters both high frequency and low frequency. 8 out of every 10 inverters that we provide repair quotes for are high frequency inverters.
EG4 18KPV- 48V Hybrid Inverter: 18,000W PV Input | 12,000W Output | 120/240V Split Phase
24:21
DIY Solar Power with Will Prowse
Рет қаралды 289 М.
EG4 Offgrid VS Hybrid Inverters! Which one is better for the $$$?! 6000XP VS 18kPV
16:31
DIY Solar Power with Will Prowse
Рет қаралды 181 М.
La revancha 😱
00:55
Juan De Dios Pantoja 2
Рет қаралды 52 МЛН
Please be kind🙏
00:34
ISSEI / いっせい
Рет қаралды 56 МЛН
Homemade Professional Spy Trick To Unlock A Phone 🔍
00:55
Crafty Champions
Рет қаралды 28 МЛН
How to bring sweets anywhere 😋🍰🍫
00:32
TooTool
Рет қаралды 45 МЛН
Choosing The Right Solar Inverter Charger | Off Grid Vs Hybrid | Cost Comparison
14:06
Country Living Experience: A Homesteading Journey
Рет қаралды 9 М.
How to Size Your Off Grid Solar System
10:21
Sleem Solar
Рет қаралды 1,7 М.
Energy efficient appliances I use for off grid solar
12:38
UnpluggedTexan
Рет қаралды 23 М.
Installation & First Impressions of the EG4 6000XP Inverter
31:27
1 Hack To Eliminate Your A/C Power Bill This Summer!
11:52
There's A Trick For That
Рет қаралды 211 М.
My Opinion on Electric Vehicles! Is everyone brainwashed!? Pros Cons and Misconceptions!
33:50
DIY Solar Power with Will Prowse
Рет қаралды 117 М.
Nhx-10kw - US  Off Grid Settings, A UL Listed 10kw inverter for under $2400
52:54
Eg4 6000 Xp All-in-one Solar System! Full Install! Extremely Affordable!
23:18
Country Living Experience: A Homesteading Journey
Рет қаралды 61 М.
La revancha 😱
00:55
Juan De Dios Pantoja 2
Рет қаралды 52 МЛН