Electrical safe isolation procedure - Single Phase

  Рет қаралды 15,942

Residual Electrical

Residual Electrical

Күн бұрын

In this video i run through the full safe isolation procedure for single phase electrical installations.
If you enjoy electrical content please subscribe to the channel and checkout my links below 👇
G S 3 8 ⚡️
www.hse.gov.uk...
M Y W E B S I T E ⚡
residualcurren...
M Y L O A D O U T 🛠️
residualcurren...
B I G B O O T S D I S C O U N T 🥾
bigboots.co.uk... - Use code RESIDUAL
U N I L I T E D I S C O U N T 🔦
unilite.co.uk/... - Use code RESIDUAL
J O I N T H E C H A N N E L 🤝
/ @residualelectrical
I N S T A G R A M 📷
/ residualcurrent
T I K T O K ♪
vm.tiktok.com/...
The works carried out in the video and the opinions shared are my own, and not representative of the associates and companies in the video.
This content is purely for entertainment purposes and is in no way a "how to", tutorial or educational video.
Please consult an electrician when dealing with any electrical installations.
#electricianlife #electrical #electricalengineering

Пікірлер: 24
@BrentLickley
@BrentLickley Жыл бұрын
I'm going through a career change and decided to carry on the family trade by training to be an electrician. This video is so clear and well-structured that it has helped me more than my tutor ever could. This video has made it so easy to understand for someone who struggles to study. Thank you
@jeffsnipes8766
@jeffsnipes8766 2 жыл бұрын
As a 28 year electrician 12 years with a masters license here in America I find your practices very interesting. We don’t send our transformers to ground the way you do. We verify the circuit is dead to our MDP by voltage readings, Not continuity. The cables you use are interesting to me as well because we run conduit for all main lines unless it’s bus duct up a high rise or through a production facility. I wonder if the NEC adopted some of the ways you do things if we could actually make it cheaper and more efficient for the end customer. I only found you a few days ago but I’ve enjoyed your content keep it up.
@krishtheobald4227
@krishtheobald4227 2 жыл бұрын
Great stuff as always Mike! One thing that JW had mentioned which I think is important (you sort of mentioned it), is that even on an approved voltage indicator with a digital display and the indicating lights, the indicating lights are what is supposed to be relied on, not the display. Looking forward for your 3 phase video 😁
@rscelectrical7091
@rscelectrical7091 2 жыл бұрын
It still amazes me the number of people that either use a Multimeter to test for safe isolation or just don't bother at all, they just flick the switch off and trust that it's done the job😢. Another great video that hopefully people will take notice of.
@damiandrozdek5688
@damiandrozdek5688 2 жыл бұрын
Following you from about 2 years. Learn a lot, happy to see you going forward 👌⚡️
@sergiofernandez3725
@sergiofernandez3725 2 жыл бұрын
Good video. Nice to see you showing the lockout was one step back from the kit you intended to work on. I look forward to the 3 phase video.
@lukeashton7085
@lukeashton7085 2 жыл бұрын
Single Phase installations test to confirm that there is no voltage between: - Line and Neutral - Line and Earth - Neutral and Earth. 3 Phase installations test to confirm that there is no voltage between: - L1 and L2 - L1 and L3 - L1 and Neutral - L1 and Earth - L2 and L3 - L2 and Neutral - L2 and Earth - L3 and Neutral - L3 and Earth - Neutral and Earth
@TheChipmunk2008
@TheChipmunk2008 2 жыл бұрын
heck yes, I proved L-N and L-E on a system a couple of years back, small house, being redone, didn't prove properly and got a massive 'lock on' belt through N-E (reversed polarity plus switching in the neutral :\ ) That will teach you more than any amount of lectures :(
@walseee
@walseee 2 жыл бұрын
Great videos as usual. Your more recent videos have got drastically better quality and you seem a lot more comfortable on camera. Keep it up 🙂
@donstir23
@donstir23 2 жыл бұрын
Quality as always brother .. appreciate the refresher on the process at hand . Stay safe Mickey 👍
@Aids9898
@Aids9898 10 ай бұрын
Watching this in college rn
@three-phase562
@three-phase562 2 жыл бұрын
Great video RC! Like how you have put a deliberate error in there for people to find 👍😉 I would add to be aware of if it is a double pole isolation, that also breaks the neutral as is the case in your video, or if it is a single pole isolation that breaks only the live. If it is single pole, then the test for dead procedure will not pick up a borrowed neutral fault, until the neutral is broken. Under this situation, after the isolation and initial test for dead, I would break the neutral as live working, and then test for dead again. This is more likely in a commercial / industrial installation however, a similar scenario exists for a PEN fault to a domestic premises, where a two pole tester may show the installation to be dead, when in reality there is still power. In this case a sweep with a non-contact voltage pen would show the live wires, or you need to find a true earth for the two pole tester.
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
Excellent advice but just one point of correction GS38 requires that we prove our voltage indicator on a known source or a proving unit rated to the same voltage as the voltage we are testing. A known source can be the incoming side of the main switch . Other than that fantastic advice and video nicely explained and well presented 👍
@charliechan22
@charliechan22 2 жыл бұрын
You are a fountain of knowledge. I have the t6-1000. I was looking at the new prv240fs proving unit. Just double checked and it only goes up to 240v. Might have to look at the tried and trusted Martindale one.
@PhilipHudnott
@PhilipHudnott 2 жыл бұрын
Good clear video. Only thing I would say is you need covers on your probes as I believe GS38 states maximum of 4mm of tip should be exposed.
@kingofthetrowel1725
@kingofthetrowel1725 2 жыл бұрын
Nice one mate very educational and helpful 🙌🏻 keep them coming 👌👌👍👍
@jackdavis8786
@jackdavis8786 2 жыл бұрын
Great videos, great content, be good to see a series of the testing procedures
@ahmadaliwi6827
@ahmadaliwi6827 10 ай бұрын
Great
@goose4342
@goose4342 2 жыл бұрын
Wait I’m confused I thought you had three phase power in 🇬🇧 for residential. But you’re saying single phase, is it single/split phase like we have in the 🇺🇸.
@jackdavis8786
@jackdavis8786 2 жыл бұрын
No single phase for residential
@goose4342
@goose4342 2 жыл бұрын
@@jackdavis8786 okay cool, thanks for clarifying.
@skellious
@skellious 2 жыл бұрын
Some new builds are now getting full 3-phase due to the requirement for new homes to accommodate an electric car charger and for heatpump installations. But normally a street has 3 phase along it and one phase to each house, divided equally. Because we have 100A 240V as standard into homes we can usually cater for quite a lot of load on one phase.
@electroaid
@electroaid 2 жыл бұрын
No devices, no gimmicks will save you from live current but some mild creative thinking might. Instance, your elbow on the side of the enclosure while working one handed on a wire harness you've never laid eyes on before. Your forearms might suffer but your chest is safe. Just one example but eh, you do you. Not like your gonna listen anyway.
@electroaid
@electroaid 2 жыл бұрын
@@residualelectrical Agreed, point is don't rely on safety gimmick but also don't rely on some safety tip your read about somewhere. I would say think and try to experiment with but that's also a dangerous venue. So instead my message to you brave souls is, god's speed.
Earth fault loop impedance testing - ZS
9:32
Residual Electrical
Рет қаралды 15 М.
If Barbie came to life! 💝
00:37
Meow-some! Reacts
Рет қаралды 50 МЛН
Кадр сыртындағы қызықтар | Келінжан
00:16
Survive 100 Days In Nuclear Bunker, Win $500,000
32:21
MrBeast
Рет қаралды 149 МЛН
IQ Level: 10000
00:10
Younes Zarou
Рет қаралды 13 МЛН
Continuity of protective bonding conductors & equipotential bonding explained
27:03
Different Types of Disconnecting Means
21:14
Electrician U
Рет қаралды 34 М.
How i priced and won my first £10K+ electrical contract
26:41
Residual Electrical
Рет қаралды 15 М.
Safe isolation in the real world. | Domestic single phase.  (61)
12:36
J Beck Electrical
Рет қаралды 3,5 М.
Retrofitting 3 phase RCBO's - Schneider Acti9 Vigi Unit's
33:34
Residual Electrical
Рет қаралды 17 М.
Terminating a 400A 3 phase supply
21:58
Residual Electrical
Рет қаралды 1 МЛН
The Mysteries of AM2 and AM2S - End Point Assessment
55:23
U.K. Electrics SUCK! This is what we should be doing…🇫🇷
19:17
Artisan Electrics
Рет қаралды 180 М.
If Barbie came to life! 💝
00:37
Meow-some! Reacts
Рет қаралды 50 МЛН