3 Types of Light for the Perfect Kitchen Remodel

  Рет қаралды 32,000

Electric Pro Academy

Electric Pro Academy

Күн бұрын

Electric Pro Academy - Real skills to make real money.
Synopsis:
This is one mighty “Part 1” for what will be a beautiful kitchen remodel. The tricky thing about electrical work is that you often can’t do it all at once; in this case, we need to dial in appliance receptacles, counter-servicing receptacles, overhead lighting, under-cabinet lighting, auxiliary pendant lighting, and some mysterious old circuitry without the appliances, counters, cabinets, or pendants in sight!
Here’s how Jefferson Electric “roughs-in” a kitchen-to-be to avoid future headaches for themselves or other tradesmen, all while identifying existing wiring and solving panel circuit limitations.
If the instruction in this video is unclear or skew to what you are searching for, feel free to comment below for additional assistance.
EPRO-2-Call:
You’ve got the tools and the willingness to solve your own electrical problem, but are held up by a couple ominous details. Rather than hiring out the whole project, get EPro’s own Joel Walsman on a video or voice call here: electric-pro-academy.square.s...
Products We’d Recommend:
*EPRO endorses pro-level tools & materials, and receives a small commission for purchases through our links from Amazon & other affiliate programs. We’d be happy to recommend more cost-effective products for DIYers and low-frequency users if you engage with us in the comment section!
[] EPRO’s Amazon Storefront: smile.amazon.com/shop/electri...
National Electrical Code (NEC) referenced in this video:
Free Access Here: link.nfpa.org/free-access/pub...
[] Countertop Outlet Requirements [NEC 210.52(B)]
[] Minimum 2 20-Amp Kitchen Circuits [NEC 210.52(B)(3)]
[] Derates/Continuous Loads [NEC 210.19]
[] Nail plates for less than 1-1/4" boring depth [NEC 300.4(A)(1)]
[] Securing & Supporting NM Cable [NEC 334.30]
[] No securement required through voids [NEC 334.30(B)]
[] GFCI Protection for Kitchen receptacles [NEC 210.8(A)(6)&(7)]
[] 1/4" of NM jacket in electrical box [NEC 314.17(B)(2)]
[] Wire connectors into boxes [NEC 314.17]
[] Box Fill [NEC 314.16]
[] Wire securement within 12" of box [NEC 334.30]
[] Switches must be grounded [NEC 404.9(B)]
Outline:
0:00 - Introduction
0:55 - Tools
4:40 - Materials
7:11 - Layout
9:59 - A Picture Is Worth A Thousand…Call-backs!
10:26 - Home Runs From Basement Panel
13:13 - Counting Desired Circuits
15:25 - Locating New Switch
20:12 - Reconciling Desired Circuits & Breaker Spaces
23:03 - Fishing Wire & Locating New Receptacles For Countertop
29:16 - Fishing Wire For New Switch & Other Receptacles
33:35 - Back To The Basement
35:11 - “Securing & Supporting NM Cable”
35:42 - Keys To Wire-Running Success
41:35 - Sink Pendant Pancake Box
45:32 - Under-Cabinet Lighting
51:22 - Terminating The Sink Switches
53:19 - Full Panel!
53:33 - Overhead Lighting
1:06:09 - 3-Way Switch
1:08:40 - Wrap-Up
Connect With Us:
Electric Pro Academy is a multimedia team dedicated to training and instructing DIYers and professional electricians for the growth and dignity of the craft nationwide.
/ electricproacademy
/ electricproacademy
odysee.com/@ElectricPro
Jefferson Electric installs and services residential, commercial, solar, and Tesla systems in Indianapolis, IN.
www.jeffersonelectricllc.com/
/ jeffersonelectric
/ jefferson-electric-llc
Got a question or ideas for a future video? Leave a comment below and submit your idea here: forms.clickup.com/f/23xa9-70/...
Thank you for watching; we value your feedback and monitor this channel daily.

Пікірлер: 73
@amunderdog
@amunderdog Жыл бұрын
Every project. I am amazed at the tools required to complete the task. As i age, i realize, better tool selection gives better results with less errors.
@williamcarvlin1934
@williamcarvlin1934 Жыл бұрын
Handy Tip: When Taping wire for pulling Always leave a "Pull Tab" for the person on the other end so they don't spend time looking for the end. (last inch stick to itself=tab).
@jarrydee2799
@jarrydee2799 Жыл бұрын
We call it a buddy loop
@Aepek
@Aepek Жыл бұрын
One of my other fav boxes is the adjustable gang boxes, as makes setting the depth just right if something hanged, ya don’t be to tear out and replace, just use the screw and make it come out or go back……great Bo to have on remodel but also can be tricky to find at times
@FHES2005
@FHES2005 Жыл бұрын
Whoever did those plumbing lines in that kitchen I don't know how he passes code cuz that hole he cut out in that Jack stud and King stud is illegal even with the nail plate cuz he destroyed the integrity of the structure
@shshshs2
@shshshs2 Жыл бұрын
Please stop, don’t act like you know what you are talking about. Just because you don’t like how it looks, doesn’t mean it wasn’t done correctly or it didn’t pass both plumbing code or residential code
@anonymousperson4363
@anonymousperson4363 Жыл бұрын
@@shshshs2 Maybe FT is a plumber and I have known inspectors pass stuff that were unsafe and against code.
@zocalo1990
@zocalo1990 Жыл бұрын
Conosco un poco de trabajo eléctrico, NO soy electricista solo un hombre viejo que disfruta de aprender cosas nuevas, Este muchacho realmente es una terapia viéndolo trabajar tan profesionalmente, trabaja limpio ,se ve su integridad como profesional electricista. Es realmente un placer verlo trabajar y escuchar sus explicaciones, Tiene una habilidad enorme, no solo como electricista sino también un talento para explicar claramente, en forma breve y concisa..Wow,muchacho Te deseo lo mejor de lo mejor para ti y tu compañía, tus empleados y familia
@Eightball2516
@Eightball2516 Жыл бұрын
I always put pieces of card board in my boxes over the wires to protect them from the roto zips
@barrycottle8282
@barrycottle8282 9 ай бұрын
I recently remodeled our kitchen. I used the ideas of dedicated circuits for microwave, toaster oven, coffee pot, insta pot. Also, as you did, dedicated line for fridge, dishwasher, and disposal. All used GFCI. One suggestion is to use an outlet with USB charging ports. I wired these into GFCI outboard so they still are protected. Thanks for a great video.
@mar1video
@mar1video Жыл бұрын
Great video ❗️ Thanks for sharing your ideas and trade secrets 😉
@redmatrix
@redmatrix Жыл бұрын
15:21 I like how you said "...knocking out that list" here and in the next scene, you're knocking on a wall.
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
😂 Our editor deserves a raise!
@vince6829
@vince6829 Жыл бұрын
Love your videos. Please keep them coming. DC driver...I learned something new. Thank you for sharing your knowledge.
@jefffielder2429
@jefffielder2429 Жыл бұрын
Thank you for all the information really enjoy your explaining every thing
@user-rr3fo6hy9q
@user-rr3fo6hy9q Жыл бұрын
My favorite part of this video is how you emphasized communication with your teammates and the contractors coming after you. The importance of communication can not be stressed enough. Awesome video.
@adamdavis2788
@adamdavis2788 Жыл бұрын
As an British apprentice electrician it’s really interesting with the differences between uk and American electrics their is a few things that horrify me (mainly lack of rcds/gfci, wire nuts, the lack of any sleeving on the cpc/ground and the state of some of your distribution boards. But it’s not all negative as theirs a few things that I’ve seen that I wish we had in the uk the colour coded second layer of installation to tell you the size of the conductor seems like a really useful thing that the uk should pick up on.
@helmanfrow
@helmanfrow Жыл бұрын
AFCI, GFCI and DF brrakers are the functional equivalents of your RCBOs, RCDs and such. Our grounds are bare free as God intended.😉
@adamdavis2788
@adamdavis2788 Жыл бұрын
@@helmanfrow yes I know you use rcds but they seem to be a lot rarer that’s obviously fine as you have different regulations but it would be interesting to see how they change in the future As for earth sleeving in the uk it’s a requirement as it could cause a short when putting outlets into back boxes between live and earth that causes faults
@helmanfrow
@helmanfrow Жыл бұрын
@@adamdavis2788 A bare ground coming into contact with a live conductor is a distinct possibility but I don't know how big a problem that is in reality. Maybe it's a huge issue of which I'm unaware. I'm not an electrician, after all. The Canadian Electrical Code now requires AFCI protection on nearly every type of residential outlet except lighting. It requires GFCI protection on any outlet in locations considered "wet". Protection can be at the breaker or outlet in most cases, although the breaker is preferable for AFCI unless you're running shielded cable. If you ask me it's mostly BS designed to sell expensive breakers and line the pockets of manufacturers and the regulation makers.
@adamdavis2788
@adamdavis2788 Жыл бұрын
@@helmanfrow just had to do a bit of research into what afci outlets are and it’s interesting that the uk is similar in the fact that affds are now becoming more required in installations but rcds are required on pretty much every circuit. It seems to be that they are both equal in the amount of protective devices required but the uk has arguably gone for the slightly safer option but in ether one I can see it all needing to be installed in the next 10-20 years
@BOBService417
@BOBService417 Жыл бұрын
Awesome video!
@mcarroll598
@mcarroll598 Жыл бұрын
Lowes and some other retailers sell a spinner to disperse mostly 250’ rolls of Mc Cable, Romex and some other different types of cable assemblies. It eliminates all the curly Q’s in the wire. Highly recommend!
@jarrydee2799
@jarrydee2799 Жыл бұрын
I bought 4 of them when we were roughing a house, they are a lifesaver
@mcarroll598
@mcarroll598 Жыл бұрын
@@jarrydee2799 definitely a life saver. I’ve been in the trade 25 years and used mine so much. And if you are running a lot of MC cable or Romex, it’s a must in my opinion. It pays for itself real quick!
@MrKen59
@MrKen59 Жыл бұрын
That screw in box you have looks awesome. Does it have a 3/8 hole for cable connector? One of the thinks I hate with plastic boxes are the self locking openings. I don’t know why I have such a hard time with those things.
@helmanfrow
@helmanfrow Жыл бұрын
I don't know about your local codes but in Ontario we can still use tandems for lighting. One of the last remaining circuit types that doesn't need expensive breakers.
@nebraskaninkansas347
@nebraskaninkansas347 Жыл бұрын
I take it the voltage requirement for the wires in the box is to insulate the wire from voltage bleeding from higher voltage to the lower voltage cable.
@RAWms
@RAWms Жыл бұрын
NM question is kind of a trick question. Run through bored holes, it is both secured and supported but still must be stapled within 12" of outlet box.
@richardscarlett7942
@richardscarlett7942 5 ай бұрын
you need to take into consideration the newer dishwashers. If you select all avaiable wash options a dishwasher can run 5 hours
@ElectricProAcademy
@ElectricProAcademy 5 ай бұрын
Good thought, we may need to revisit that...
@richardscarlett7942
@richardscarlett7942 5 ай бұрын
well, I'm not an electrician but I am a Liscenced plumberI only know this because I have one of these crappy new low water dishwashers@@ElectricProAcademy
@traviswilliams5225
@traviswilliams5225 Жыл бұрын
Dishwasher are Considered as continuous loads.
@devonholford3331
@devonholford3331 Жыл бұрын
Gm good work
@bahbarino4479
@bahbarino4479 Жыл бұрын
Drywall sheer only. Truss screws 👌🏼
@benjaminmattern3822
@benjaminmattern3822 Жыл бұрын
Uncoil ur wire don't pull it off the spool !! And u can always pull a fridge or another appliance circuit back to the panel and double it up so you are covered..micro..2 appliance and dishwasher/ disposal all get home run ..u can double up then u have it if need
@edfountain4727
@edfountain4727 Жыл бұрын
FYI you can seal sharpie mishaps with any metallic spray paint.
@mcarroll598
@mcarroll598 Жыл бұрын
First time I saw WAGO’’S come with recessed can lights was around 2008. I believe Halo started doing it.
@billm6171
@billm6171 Жыл бұрын
Support only
@ricks1611
@ricks1611 Жыл бұрын
The receptacle below the sink for the dishwasher should not have a GFCI there because doesn't code say a GFCI has to be accessible to test monthly. Behind a cabinet door under the sink is not considered accessible? Same thing if you put a GFCI behind a refrigerator.
@trudyerwin8821
@trudyerwin8821 6 ай бұрын
Do you ever use Walabot before drilling through walls? I have been thinking about getting one...
@Bradley-tx6ed
@Bradley-tx6ed Жыл бұрын
we call them slider boxes
@lahcfaou9207
@lahcfaou9207 2 ай бұрын
How far should I put the light from kitchen cabinets and between a light to light
@jarrydee2799
@jarrydee2799 Жыл бұрын
I was not aware of any code in residential that say how many outlets you can have on a circuit.
@brianc3481
@brianc3481 Жыл бұрын
What can be said about a panel that is in a basement and walls above it have pipe runs above it? like PEX that is continuous?
@johnrackiewicz286
@johnrackiewicz286 5 ай бұрын
What is BX? Can't find it anywhere in NEC or the depot. Are you talking about AC? Let's TRY to keep it professional.
@tinker8115
@tinker8115 Жыл бұрын
the new kitchen circuits look to be protected by non-afci breakers at 53:22. Are those new circuits not required to be AFCI protected?
@Byron88
@Byron88 Жыл бұрын
I'm surprised you're allowed to have a fridge and stove on same circuit, they each have to be a "seperate branch circuit" by code in Canada
@jarrydee2799
@jarrydee2799 Жыл бұрын
SOme people make the fridge dedicated, I don't. 2 circuits for the entire kitchen is fine, unless you have some crazy big kitchen.
@helmanfrow
@helmanfrow Жыл бұрын
Are the junctions on those lighting cans accessible without disturbing the finish?
@EXLMOB
@EXLMOB Жыл бұрын
Most cans are accessible, there are 3 or 4 screws on the can itself and you can pop out the can if needed,
@lahcfaou9207
@lahcfaou9207 7 ай бұрын
Hi Can a gas oven outlet and fridge be on the same circuit?
@danielkofman4592
@danielkofman4592 Жыл бұрын
Can you show us the driver that will operate the low volt lights? How will it fit into the single gang?
@AdamS-lh2ug
@AdamS-lh2ug Жыл бұрын
I’m curious too, as my former company used a single gang driver that cost like $150 but sounded like they where having issues with them.
@NGinuity
@NGinuity Жыл бұрын
Honest question, not a complaint: All that fussing about with trying to cram 6 circuits into 4, could you not have just come off of the main with a sub panel for about the same amount of labor time? Your issue was a matter of total circuits and not load estimation correct?
@FHES2005
@FHES2005 Жыл бұрын
I know it's out but I haven't yet read the new 2023 NEC book yet
@piezoman79
@piezoman79 7 ай бұрын
11:49 is that gas line run through treated lumber? Is that allowed?
@jasonmoretski6910
@jasonmoretski6910 Жыл бұрын
You should buy a wire wheel that way you romex wire is nice and straight
@tobybrubaker455
@tobybrubaker455 Жыл бұрын
What's the power consumption of the range that your only running 12 wire?
@mar1video
@mar1video Жыл бұрын
They mentioned a gas line , so most likely the stove is gas (NG or LP).
@shanebibby6006
@shanebibby6006 Жыл бұрын
Tandems are allowed
@Aepek
@Aepek Жыл бұрын
23:06 lol, should be at my house, coffee pot on 12 HRS a DAY 🤦🏼, I know……have fam members who drink coffee all day long
@DirkGorgiel
@DirkGorgiel Жыл бұрын
Wirenuts? Is that still american Zeitgeist,1920's?
@helmanfrow
@helmanfrow Жыл бұрын
"Labour savings worth it? Maybe." ...he says, huffing and puffing at the top of a ladder with arms stretched out overhead. We're not getting any younger, my dood. For lighting connections lever nuts are a no-brainer. You say as much yourself a few moments later. Take your own advice, already. 😁
@russrockino-rr0864
@russrockino-rr0864 Жыл бұрын
A lot of the recessed cans now come with Wago-style connectors.
@nagydeak
@nagydeak Жыл бұрын
wait.... when did u get a real hammer ;) 27:59
@ElectricProAcademy
@ElectricProAcademy Жыл бұрын
Cliff's 😅
@brandonrippeonphoto
@brandonrippeonphoto Жыл бұрын
Plumbers always just cutting the shit out of framing…
@quillita
@quillita Жыл бұрын
Do you like fish sticks .?
@BroskiTheGreat
@BroskiTheGreat 10 ай бұрын
This guy 😂🤡
@russrockino-rr0864
@russrockino-rr0864 Жыл бұрын
Drivers also regulate the current to the LED,s Joel. Remember LEDs are current sensitive devices.
@larrypollard5347
@larrypollard5347 6 ай бұрын
you’re a very good master electrician,however you talk to much
@ElectricProAcademy
@ElectricProAcademy 6 ай бұрын
😅 Sorry about that. Working on finding the right balance for KZfaq.
When Light Switches Get Complicated: Dead-End 3-Way Dimmer Installation
10:54
Electric Pro Academy
Рет қаралды 20 М.
Rewiring A Kitchen With An Extra Light
1:14:13
Electric Pro Academy
Рет қаралды 51 М.
Неприятная Встреча На Мосту - Полярная звезда #shorts
00:59
Полярная звезда - Kuzey Yıldızı
Рет қаралды 7 МЛН
The joker's house has been invaded by a pseudo-human#joker #shorts
00:39
Untitled Joker
Рет қаралды 13 МЛН
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 10 МЛН
Basement Transformation: Dungeon To De-Light
36:45
Electric Pro Academy
Рет қаралды 24 М.
5 Questions an EV Charger Installer Should be Able to Answer: Fulsolen Smart A01
11:47
Installing A Receptacle For Any Major Electrical Appliance
37:27
Electric Pro Academy
Рет қаралды 29 М.
Middle of a Manhunt! Roller Arrives for Road Build
31:53
Outdoors With The Morgans
Рет қаралды 61 М.
Running Wire In A Bathroom Remodel (Part 2)
28:51
Electric Pro Academy
Рет қаралды 16 М.
Led light installation under the kitchen units .
0:28
Mani Sehgal
Рет қаралды 537 М.
TAMCO Electrical Manufacturing Tour
32:23
Electric Pro Academy
Рет қаралды 2 М.