Class 10 | Fire Pump Room Layout Design NFPA 20 | Part 1

  Рет қаралды 1,352

Irfan CFPS

Irfan CFPS

24 күн бұрын

In this video, we shall cover the following :
1) What is a fire pump shed/enclosure/room,
2) Essential aspects of the fire pump room,
2a) Main components
2b) Key considerations
3) Pipe sizing
4) Fire Pump sizing
5) Fire pump room layout design.
#firepump #firefighting #nfpa #fire #fireprotectionirfan cfps #trending #construction #firefighting #fireengineering #fire #mep
Explore following links :
NFPA 20 is the standard for Fire Pumps
Class 1 | Mastering NFPA 20 Fire Pump Room Pipe Sizing
• Class 1 | Mastering NF...
Class 2 | Mastering Fire Pump Sizing per NFPA 20
• Class 2 | Mastering Fi...
Class 3 | NFPA 20 Fire Pump | Types of Fire Pumps
• Class 3 | NFPA 20 Fire...
Class 4 | Acceptable Back up Fire Pumps NFPA 20
• Class 4 | Acceptable B...
Class 5 | Performance Curves NFPA 20 | Part 1
• Class 5 | NFPA 20 Fire...
Class 6 | Performance Curves NFPA 20 | Part 2
• Class 6 | Performance ...
Class 7 | Performance Curves NFPA 20 | Part 3
• Class 7 | Performance ...
Class 8 | "NFPA 20 Fire Pump : Pressure Settings!"
• Class 8 | "NFPA 20 Fir...

Пікірлер: 28
@mirkamrulhasankonok9752
@mirkamrulhasankonok9752 17 күн бұрын
Thanks for this excellent video. It helps me a lot
@irfancfps
@irfancfps 17 күн бұрын
Pls share with others as well so that they can benefit from my videos
@rajeshamdurgam9970
@rajeshamdurgam9970 10 күн бұрын
Exlent sir
@irfancfps
@irfancfps 10 күн бұрын
Thanks and welcome
@apoorvchoudhary774
@apoorvchoudhary774 16 күн бұрын
Excellent video sir. Please make video on cable size and cable tray calculation for fire pumps
@irfancfps
@irfancfps 16 күн бұрын
Sure. Very soon
@mariomabaga2014
@mariomabaga2014 19 күн бұрын
Thanks sir
@irfancfps
@irfancfps 19 күн бұрын
Most welcome.
@teokokwah9911
@teokokwah9911 22 күн бұрын
good explaination. thank you.
@irfancfps
@irfancfps 22 күн бұрын
Thank you
@ShamsETabreezAzad
@ShamsETabreezAzad 22 күн бұрын
Can you make foam suppression system calculation video?
@irfancfps
@irfancfps 22 күн бұрын
Ya definetly. Will make video once i start training module on foam systems. Thanks for your suggestion.
@ibrahimn.j.4943
@ibrahimn.j.4943 10 күн бұрын
Thanks Eng. Irfan for the video. I have a question roaming my mind: Let’s say we have 3 pumps (joceky, electric, diesel), in normal situation (standby condition) What readings should I expect to see on each suction/discharge line gauge? Should they all be identical?
@irfancfps
@irfancfps 9 күн бұрын
When pumps are not running, discharge guage reading is zero or slightly high since there is nrv in discharge line.
@apoorvchoudhary774
@apoorvchoudhary774 16 күн бұрын
Distance of flowmeter to either isolation valves should be as recomended by the meter manufacturer. This is as per NFPA 20 2022, A Explanatory notes, A.4.22.1.3 (1) and figure A.4.22.1.3(a) and A.4.22.1.3 (b)
@irfancfps
@irfancfps 16 күн бұрын
@mariomabaga2014
@mariomabaga2014 19 күн бұрын
To ensure that the pump house remains fire-rated, introducing open areas such as provisions for the installation of a ventilation system, if needed, would compromise the integrity of the fire-rated structure we aim to maintain... ???Am i correct sir?
@irfancfps
@irfancfps 19 күн бұрын
No. As per nfpa 20 there is no such exception
@hafeezrahman7225
@hafeezrahman7225 13 сағат бұрын
How to design the ventilation system for fire pump room. Any documents ?
@irfancfps
@irfancfps 3 сағат бұрын
I already mention the requirements in the video.
@ibrahimn.j.4943
@ibrahimn.j.4943 6 күн бұрын
Where do I usually find the flexible connector in terms of location in my piping? And Is it required on all systems?
@irfancfps
@irfancfps 6 күн бұрын
Flexible connection is not usually installed in fire pumps suction and discharge piping. However, Please refer to NFPA 20 (Ed 2019), Section 4.16.6.5, flexible coupling for strain relief can be used on suction piping.
@ibrahimn.j.4943
@ibrahimn.j.4943 6 күн бұрын
What is the flange used in suction side of pumps and water tank called?
@irfancfps
@irfancfps 6 күн бұрын
There is no specific terminology for suction side flange. The type of flange can be either slip on flange or raised face flange to be considered based on the fire pump suction side flange. For the water tank, a puddle flange will be installed. Let me know for any further queries.
@landseekers6798
@landseekers6798 22 күн бұрын
Where is antivortex plate?
@irfancfps
@irfancfps 22 күн бұрын
It will be installed in the tank
@landseekers6798
@landseekers6798 22 күн бұрын
Where is antivortex plate?
@irfancfps
@irfancfps 22 күн бұрын
It’s in water tank. Puddle flange is with vortex plate only.
How to size Plumbing Water pipes using Fixture Units
12:26
MEP Academy
Рет қаралды 37 М.
Как бесплатно замутить iphone 15 pro max
00:59
ЖЕЛЕЗНЫЙ КОРОЛЬ
Рет қаралды 6 МЛН
What it feels like cleaning up after a toddler.
00:40
Daniel LaBelle
Рет қаралды 77 МЛН
Class 26 | How to design sprinkler system? NFPA 13
21:31
Irfan CFPS
Рет қаралды 3,1 М.
Fire Pump Sensing Line: Summary of Requirements from NFPA 20
6:48
Flameguard Fire Protection Philippines
Рет қаралды 390
Fire Fighting Design Basics - Updated 2021 #firefighting #mep #smtechno
4:10:14
SM Techno MEP Training Services
Рет қаралды 54 М.
How The Flawed Fire Escape Took Over New York - Cheddar Explains
8:20
Mapping the Trump Shooting
6:12
fern
Рет қаралды 14 МЛН
HYDRANT SYSTEM 3D
6:31
Maharashtra Industries Directory
Рет қаралды 17 М.
Fire Pumps in Buildings #2839474562001
4:57
Fire Engineering
Рет қаралды 24 М.