Cell Cycle Basics in FlowJo

  Рет қаралды 25,742

FlowJo Media

FlowJo Media

3 жыл бұрын

Find more FlowJo tutorials here: www.flowjo.com/learn/flowjo-u...
Download the latest version of FlowJo: www.flowjo.com/solutions/flowjo

Пікірлер: 24
@armandoes
@armandoes 29 күн бұрын
Very usefull video. Would´ve been nice to watch the whole procedure, from FSC/SSC --> FL2A/FL2W(or other doublet discrimination method) --> Cell cycle analysis
@ngohuong6550
@ngohuong6550 3 жыл бұрын
Very helpful! Please do more like this! Thanks
@user-di3or8zb5g
@user-di3or8zb5g 3 жыл бұрын
Thank you for your video! It was really helpful!
@nathaliaalmeida9873
@nathaliaalmeida9873 Жыл бұрын
super helpful, thank you so much!
@mikey27
@mikey27 2 жыл бұрын
Awesome thanks!
@job506
@job506 4 күн бұрын
Thank you, FlowJo. As a further clarification, I think gating the phases for the control for use with other samples should only be applicable if the cells were synchronized when the treatments were carried out. Could you kindly confirm?
@leonie47158
@leonie47158 28 күн бұрын
is it the same if you stain your cells with propidiumiodid? or is there a different range on the x-axis for the phases?
@egs8545
@egs8545 3 жыл бұрын
What if your data doesn’t fit the cell cycle model?
@barkhasaraswat6956
@barkhasaraswat6956 5 ай бұрын
If i want to change scale bar on x-axis how can i change
@armandoes
@armandoes 7 ай бұрын
what happens if the position of G1 shifts between samples and I applied the same model to every sample (restricting G1): For instance, the peak appears in 200 in one sample and in 230 in another sample. I should manually reset the position of said sample, shouldnt I?
@FlowJoMedia
@FlowJoMedia 6 ай бұрын
Hi user, as long as the peak is still within the G1 gate, the model should work as expected. If the peak has shifted outside of the gate then the G1 gate will need to be shifted to include the G1 peak. If you have more questions please email us at FlowJo@bd.com!
@job506
@job506 5 күн бұрын
@@FlowJoMediaHi, the suggestion of shifting the gate is contrary to what Jack indicated in the video. The essence of gating is to be able to use the control as a standard to compare with the other tests.
@FelipePorto1
@FelipePorto1 11 ай бұрын
What may happening in my cell cycle analyses when my cells shows more G2/m than G1? Like it's inversed...
@FlowJoMedia
@FlowJoMedia 11 ай бұрын
Hi Felipe, please reach out to us at flowjo@bd.com and we can assist you further and discuss some possibilities in this case. Thank you!
@helenathanasiadis454
@helenathanasiadis454 2 жыл бұрын
What happens if I try to open up a cell cycle model from my control and it says "could not calculate model: unable to calculate model based on inputs"?
@MinhHaovnpy
@MinhHaovnpy 2 жыл бұрын
do you find out the solution for this case?
@vivi7279
@vivi7279 Жыл бұрын
Hey, greetings! Did you solve this?
@vivi7279
@vivi7279 Жыл бұрын
I got it! You have to change the filter to "FSC-A :: FSC-A"
@revathyram905
@revathyram905 Жыл бұрын
@@vivi7279 Hi! Sorry could you please clarify how you solved the above problem?
@job506
@job506 8 ай бұрын
Hi sir: At minute 21:20, you made a statement which is contrary to the data. More cells in G1 phase for the control, but it's not so. How will your clarify this, please?
@FlowJoMedia
@FlowJoMedia 8 ай бұрын
Hi, For the data Jack presented the cells were released from an inhibitor keeping them in the G1 phase before the experiment began. Because the data was acquired shortly after the cells were released from the G1 phase, most of the cells for the experimental samples were in S phase. The distribution of cells in other cell cycle experiments may look different depending on the inhibitor used and the time at which the data was acquired.
@job506
@job506 4 ай бұрын
@@FlowJoMedia Many thanks. In addition, it seems single cell discrimination was not carried out after gating out cells from debris.
@Vintagelego
@Vintagelego 8 ай бұрын
if you guys are going to use shortcuts, you should write them on the video. This should also just be a written tutorial so people don't need to watch videos to use a product
@podo-dw6iv
@podo-dw6iv Жыл бұрын
thanks
How to use Proliferation in FlowJo
15:21
FlowJo Media
Рет қаралды 11 М.
Traditional Compensation in FlowJo
9:26
FlowJo Media
Рет қаралды 48 М.
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 162 МЛН
🤔Какой Орган самый длинный ? #shorts
00:42
Русалка
01:00
История одного вокалиста
Рет қаралды 7 МЛН
Cell cycle analysis by flow cytometry
32:27
Dr Germán Rosas-Acosta
Рет қаралды 19 М.
Cell Cycle Analysis by Flow Cytometry
12:12
Dr Germán Rosas-Acosta
Рет қаралды 34 М.
Flow cytometry for DNA analysis
11:11
Marcos Garcia-Ojeda
Рет қаралды 69 М.
Introduction to FlowJo v10 March 2022
1:52:30
FlowJo Media
Рет қаралды 30 М.
DNA Cell Cycle Analysis
44:04
De Novo Software - FCS Express
Рет қаралды 1,4 М.
FlowJo [BASICS]
10:40
Aja Rieger
Рет қаралды 29 М.
Cell Cycle Analysis by Flow Cytometry (Webinar)
33:32
ACEA Biosciences - A part of Agilent
Рет қаралды 14 М.
Flow Cytometry & FACS  |  Beginner Data Interpretation Tutorial
8:42
How Many Balloons Does It Take To Fly?
00:18
MrBeast