FP200 Gold Cable + Flames = ?

  Рет қаралды 21,410

John Ward

John Ward

5 жыл бұрын

A look at some Prysmian FP200 Gold cable including what happens when flames are applied to it. This example is 2 core, 1.5mm².
► Support this channel:
Patreon: / jwflame
PayPal Donations: xo4.uk/?PPP
► Social Media:
Twitter: / jwflame
Facebook: / jwflame
Instagram: / jwflame
► Contact info, sending stuff in: etc.:
xo4.uk/?YTT
► Website - More on this video and many other subjects
Website: www.flameport.com

Пікірлер: 139
@johnpriceuk
@johnpriceuk 5 жыл бұрын
"people with nothing better to do" says the man burning cables with a blow torch in his back yard... on a serious note, another very interesting video, as expected
@TheChipmunk2008
@TheChipmunk2008 5 жыл бұрын
I'd say the videos cause a larger overall pleasure coefficient than the fan with a parachute. (but to be fair, the basic idea did give colin furze a head start on his bike...)
@andrewschannel3635
@andrewschannel3635 5 жыл бұрын
Testing cables serves more purpose, than flying around on that ridicules parachute with an engine. Also it odd that’s it’s legal to do that, but the kids that ride their motocross bikes across the field outside my back garden do so illegally.
@johnpriceuk
@johnpriceuk 5 жыл бұрын
Andrew Stevens yes I agree, it was just a bemused observation
@johnpriceuk
@johnpriceuk 5 жыл бұрын
Mike Trump yes I am a big JW fan, it was just a bemused observation, no need to get worked up
@deezelfairy
@deezelfairy 5 жыл бұрын
Paragliding is aviation for the poor, not the rich 😂
@krz8888888
@krz8888888 5 жыл бұрын
Impressive, I didn't expect the inner wires to be intact after this much heat
@simongreenidge6454
@simongreenidge6454 5 жыл бұрын
NO ONE expects the Spanish...oh wait...
@robroysyd
@robroysyd 5 жыл бұрын
For those who asked 'where are these used?'.One function you'll find these or MIMS used for in high rise buildings is the power to the stairwell pressurisation fans. In the event of a fire those fans keep a positive air pressure in the stairwells to prevent them becoming a chimney.
@havoctrousers
@havoctrousers 5 жыл бұрын
I live in a flat in a country house that was previously used as a hospital. Our fire alarm system is done in a 1970s version of this FP200 stuff. Ours seems less rigid and has a white sheath. 50% of our communal electrics and flat submains are the 60 year old pyro cables fitted for the hospital and it's still going strong! I expect it to outlast all the modern T+E stuff we've added since.
@CharlieFlemingOriginal
@CharlieFlemingOriginal 5 жыл бұрын
Deadpan delivery of, "now that annoying peice of junk has flown away..." lmao :D
@ZocXer99
@ZocXer99 5 жыл бұрын
I laughed :D
@doktoruzo
@doktoruzo 5 жыл бұрын
@@ZocXer99 ...me too. This guy is sooo deadpan
@eliotmansfield
@eliotmansfield 5 жыл бұрын
Big Clive heard about some pink stuff and flames and flew in to investigate.
@muzikman2008
@muzikman2008 5 жыл бұрын
Ha ha.. Big Clive flying over checking up on your antics 😂 great video JW always wanted to see how FP200 performed under fire conditions. I should imagine the conductor size needs increasing on FP cable due to heat causing higher resistivity in copper.. Or maybe it's negligible?
@TheChipmunk2008
@TheChipmunk2008 5 жыл бұрын
@@muzikman2008 I'd say unless it's called on for heavy duty applications (like maybe fire ventilation fans) then it'd be negligible, but you raise an interesting point. I remember the old heat proof Pyro seals with the lead based glass sealing compound, specifically for fire shutters and vent fans.
@Lauriemine
@Lauriemine 5 жыл бұрын
I work with this stuff every day, as a fire alarm engineer. Its nice to strip and the cores smell really nice. If you know, you know.
@grahammuppet
@grahammuppet 5 жыл бұрын
Much prefer ventcroft fp
@grantrennie
@grantrennie 5 жыл бұрын
Have gone through lorry loads of prysmian and draka, Cleveland as well I think 🤔
@stumbleruk
@stumbleruk 5 жыл бұрын
Prysmian FP200 for me every time. Strips easily and always consistent.
@1987jugernaut
@1987jugernaut 5 жыл бұрын
Smells like candy
@Dog-whisperer7494
@Dog-whisperer7494 3 ай бұрын
FP200 was made by Pirelli it was made to withstand temperatures as low as -50c and as high as +1000c , it was classed as arctic cable and was available in Red white Blue and orange. The conductors were wrapped in a thin light blue foil then wrapped in aluminium then the outer sheath. It was mainly used for fire alarms systems emergency lighting In hospitals nursing homes and schools and other public buildings. We used the white version for emergency lighting in a new nursing home back in the early to mid nineties. The fire alarm system was installed by a different company and they use the Red version. These days FP200 is a little different but still a fantastic cable.
@crazygeorgelincoln
@crazygeorgelincoln 5 жыл бұрын
I was expecting a youth on a 'borrowed' moped.
@acestu
@acestu 5 жыл бұрын
I always fly my microlite over your garage coz there always seems to be great thermals
@DarrenDignam
@DarrenDignam 5 жыл бұрын
I imagine the puffing up of the outer sheath acts to further thermally insulate the inner cores, a type of carbon aerogel where it gets too hot.
@BenjaminEsposti
@BenjaminEsposti 5 жыл бұрын
Yes, it's called an "intumescent" material. Not to be confused with "tumescence" XD
@grantrennie
@grantrennie 5 жыл бұрын
@@BenjaminEsposti like the pillows and pads only different manufacturing materials
@twentycm
@twentycm 5 жыл бұрын
wow, I didn’t know that it can tolerate so much heat and such a direct sharp flame, thanks John
@gbelectricks
@gbelectricks 5 жыл бұрын
I can imagine Johns nextdoor neighbours looking through the curtains and saying, ”Come and look what Johns up to now Joyce. He’s trying to set fire to something today”😁 🔥 On a serious note though, it was a very informative video👍
@BigPinkJohn
@BigPinkJohn 5 жыл бұрын
Another great video JW. I have learnt so much from your videos so thank you.
@christastic100
@christastic100 5 жыл бұрын
It’s a great cable. I use it regularly in wood sheds and buildings mostly for lighting circuits. Haven’t given it the blow torch test yet so interesting to see what happens.
@davidclark3603
@davidclark3603 5 жыл бұрын
Excellent video again John. I was very surprised at the outcome. It really does its job. A fire alarm would hold its integrity long enough for it to do its job in an emergency. I’m very old school and close to retirement and like a lot of other guys,I haven’t been impressed with modern day plastic products,. This product has earned my total respect. Yes, I know it’s been going for donkeys years, but I’m impressed. I still mourn the disappearance of Pyro cable (my favourite) and most of the engineering side to this industry. It would be interesting to see how this would stand up to a hostile environment/ atmosphere? Hammer blows, chemicals, corrosion, acid, alkalis, pressure and other physical abuse? Thanks for your time John. Your videos are brilliant!
@ollieb9875
@ollieb9875 5 жыл бұрын
Pretty amazing stuff! Cheers JW 😁🙂
@DMSparky
@DMSparky 5 жыл бұрын
Also John the amount the small aircraft was annoying you had me laughing out loud.
@wilbertbirdner1303
@wilbertbirdner1303 5 жыл бұрын
Installation of MIMS is a lost art form.
@craiga6557
@craiga6557 4 жыл бұрын
Did them in college, ripped out off buildings but never installed it on site. The stuff seemed like a real pain to install but there's no denying it's quality and the nice finish it has
@elcam84
@elcam84 5 жыл бұрын
Impressive stuff. I do commercial electrical and haven't seen wire like that here in the US but fire protection is it's own animal here and I just get annoyed when I see their low voltage red alarm wire haphazardly run through ceilings and usually in the way. It's basically a little better than cat5 just has a fireproof plastic.
@grantrennie
@grantrennie 5 жыл бұрын
I worked beside an American electrician that moved here for a while, all the cables are different stateside. I had a look at the fire alarm panels when I was staying in America and they are totally different too, good and trouble come to mind
@ethanpoole3443
@ethanpoole3443 5 жыл бұрын
So basically the outer (red) insulation is designed to be intumescent so as to shield the inner conductors from the intense heat. Pretty clever as I have never seen such a cable until now, though it makes perfect sense.
@fmc1192
@fmc1192 5 жыл бұрын
Interesting, but one of the most important considerations is the correct installation of this cable. In fire alarm installations the sounder circuits need to operate for a period of at least 30 minutes (detection circuits can fail at any time as they have done their job. FP200 will burn through but it becomes rigid and self supporting if installed correctly with the right spacing and the correct saddles, clips and or cable ties. I have witnessed this cable installed without be fixed above voids and tied to the underside of cable tray with nylon tie, it would fall off and fail. Also, consider the glands and boxes fitted.
@manickn6819
@manickn6819 5 жыл бұрын
Great video. I was wondering about FP200 for some time now.
@raychambers3646
@raychambers3646 5 жыл бұрын
I remember when this cable when it first came out nightmare to strip and needed ferrules on ends to stop it shorting out due to very soft insulation being cut by alli core.looks like its come on a lot since then .nice vid JW.
@jonathandugan7418
@jonathandugan7418 5 жыл бұрын
Another good video John
@clivequinn8978
@clivequinn8978 5 жыл бұрын
Always found great satisfaction doing a job in Pyro.
@PARANOOB
@PARANOOB 5 жыл бұрын
Paramotors cost less than motorbikes, and are approximately 863.7 times more fun.
@lamppostinnarnia
@lamppostinnarnia 5 жыл бұрын
Oh my god im getting one 😮😮😮
@1pjodan
@1pjodan 5 жыл бұрын
I use this for lighting installations at work for our lights, led panels in a ceiling grid. The rigid ness of the cable makes it nicer to do a neat job
@grantrennie
@grantrennie 5 жыл бұрын
Thanks for the great video John 👍 The old pyro needs special tools to strip it, have fitted about 100 miles of fp200 over the years myself, easy to strip.. lots of powder coated copper p clips
@1987jugernaut
@1987jugernaut 4 жыл бұрын
Grant Rennie pyro needs banning absolutely the worst of cables around
@richardfraser1562
@richardfraser1562 3 жыл бұрын
The flying contraption! I died.
@antonios4926
@antonios4926 4 жыл бұрын
Hi John. Thanks for all your videos. U r very knowledgable. Can we run fire alarm cables in steel trunking with other cables? Or do we have to keep them separate?
@arkadybron6120
@arkadybron6120 5 жыл бұрын
I had to wire the apparatus room of a Soho facilities house in 1983 with that stuff and actually routing 83 circuits into a single power cabinet wasn't the most fun I've ever had. It has quite a large turn radius because of the aluminium cladding and so routing it in a confined space without damaging it can be quite a challenge. Having said that, it out performs a lot of other fireproof power cables. It does require (or did) a plastic ferrule end cap, to prevent the insulation of the inner conductors from being damaged by the sharp edge of the aluminium sheath at the strip point.
@spudhead169
@spudhead169 2 жыл бұрын
"It's just some nutter ..." hahahaha, JW you kill me man.
@WaynesElectrical
@WaynesElectrical 5 жыл бұрын
OK, I have to say a couple of things about this vid. They are: (1) Would it be possible to get a small wood-based fire going and hold a section of this cable over the fire? On the end of it, put a 60w lightbulb, and on the supply end, ballast it with a 3kW water heater so that if the cable does internally short, it will not make a massive fault current as it lets loose. The water heater should not become too warm as it will be restricted by the 60w bulb, but if the cable internally shorts out, you will know because the water heater will go full bore. Then...... repeat with a standard piece of 2.5mm twin and earth 6242Y. (2) That device being flown in the sky is what's called a paramotor. Have a look on here for paramotoring vids and you will see that they actually are an intersting way of getting about! Not many people could afford a light aircraft (and associated running costs, maintenance, flight lessons and pilots licence) but for a few thousand, you can take flight with a paramotor. :D I know if I had the coin, I would like to say to my electrical stickist one afternoon: _"I will be there by 2pm to collect my order, and by the way.... keep a watch on the sky, I am coming in by air! "_ :D That would be TASTY. That would put a whole new meaning on "Flying Sparks" :D Thanxx for shkwing, -Waynes' Electrical. _27th February 2019, 01.55_
@uK8cvPAq
@uK8cvPAq 5 жыл бұрын
Yo BoomBox is that you?
@dglcomputers1498
@dglcomputers1498 5 жыл бұрын
Closeish to where I suspect he (JW) lives there are many people who could easily afford an aircraft of some sort, look up Sandbanks, Poole. If you ain't got a few mil you are not getting a house.
@WaynesElectrical
@WaynesElectrical 5 жыл бұрын
Hiya. _"BoomBoxDeluxe"_ is now a *Wayne's Electrical* brand. Pop over soon, watch vids & *_BAAANG_* the subscribe button. :D -Wayne's Electrical. _27th February 2019, 19.00_
@heronimousbrapson863
@heronimousbrapson863 5 жыл бұрын
Just don't fly paramotors over sewage lagoons just in case..... you know...
@petehiggins33
@petehiggins33 5 жыл бұрын
When it comes to flying contraptions it seems that the smaller they are the more noise they make. I often get a posse of five or six of these paramotors flying directly overhead in fine weather but not usually at this time of year.
@lamppostinnarnia
@lamppostinnarnia 5 жыл бұрын
Great video thank you
@MrDubje
@MrDubje 5 жыл бұрын
Excellent video. Are there special junction boxes for this type of installation too? Or perhaps high temperature resistant terminal blocks to connect them? I only ever see the red cable going from place to place, but terminated in what seem regular PVC junction boxes. I wonder if there are special requirements for the junction boxes too.
@jwflame
@jwflame 5 жыл бұрын
Joints are supposed to be done with ceramic terminal blocks. Ideally no joints at all, just a single unbroken cable from one point to another (such as a fire panel to a detector).
@virchoul
@virchoul 5 жыл бұрын
Flying the angry wasp looks like more fun than arson with a blowtorch.
@BrilliantDesignOnline
@BrilliantDesignOnline 5 жыл бұрын
Aerial contraptions RULE :-)
@tysondundas1947
@tysondundas1947 2 жыл бұрын
The CPC is tinned to stop the galvanic reaction between the aluminium sheath and the copper conductor.
@patricbrown8721
@patricbrown8721 6 ай бұрын
Hello John, your videos are always useful. What I wanted to ask is what do you use to strip a long length of fp 200 ,say where it enters a dist board before terminating. I very found a lot of strippers don't work well longitudinally and you end up pulling on the earth to strip the cable.
@JohnGotts
@JohnGotts 5 жыл бұрын
Electrical standards in England are quite impressive. Here in the US, I have always purchased metal power strips. They're uncommon now but they give me peace of mind. I am never happy when I see plastic power strips.
@StrathpefferJunction
@StrathpefferJunction 5 жыл бұрын
UK. England doesn't have its own electrical regulations. 🙂
@dianedyas5665
@dianedyas5665 5 жыл бұрын
Excellent video thanks. Just an idea you could make a video about the amount of smoke produced when standard pvc pvc cables burn versus lsf type.
@jwflame
@jwflame 5 жыл бұрын
kzfaq.info/get/bejne/ac6pgZZ_tNPVd6M.html
@fredjones7307
@fredjones7307 5 жыл бұрын
Give and take Mr Ward. Heard worse coming from people's front and back gardens on a Sunday morning..try a smile now and again.. might help..
@willford8475
@willford8475 5 жыл бұрын
That Campingaz cylinder is in a state, when did you buy it, 1982?
@matthewbeddow3278
@matthewbeddow3278 5 жыл бұрын
Thank you John . Very impressive and much easier to terminate than pyro cable .
@leonblittle226
@leonblittle226 5 жыл бұрын
Now that is rather impressive, in particular the inner cores remaining almost untouched after that level of heat. What is the mandated use of this other than fire alarm circuits ?
@grahammuppet
@grahammuppet 5 жыл бұрын
Disabled refuge alarms
@PaulSteMarie
@PaulSteMarie 5 жыл бұрын
What's the point of the aluminum liner in the outer jacket? Flame resistance, mechanical protection, grounding, EMI shielding?
@risvegliato
@risvegliato 5 жыл бұрын
All of those things, I would guess.
@tlangdon12
@tlangdon12 5 жыл бұрын
Actually, I think it is there primarily for Flame/Fire Resistance, and for mechanical protection as secondary property. It is not thick enough to provide significant mechanical protection, although it is clearly strong enough to protect against light knocks. It's not there to provide grounding, this is the purpose of the uninsulated conductor within the cable. It is not there to provide EMI shielding as there is no way to maintain the shielding through junction boxes etc., and there is no requirement for these cables to provide EMI shielding.
@simonrawle7885
@simonrawle7885 5 жыл бұрын
the outer covering looks like it put its self out . is that sort sort of halogen plastic
@Droningonuk
@Droningonuk 5 жыл бұрын
That was a paramotor john short take off and landing ultimate freedom I would love one. I once did a tandem flight it was both the most fun I've ever had and the most scared I've been I would definitely recommend. Good video as always!
@Jonnyweareten
@Jonnyweareten 3 жыл бұрын
flying lawnmower! love it.
@whizzo94
@whizzo94 4 жыл бұрын
Thought you might have put a megger on the cable before you cut it up?
@craiga6557
@craiga6557 4 жыл бұрын
You should set up a comparison of different cables (sy, pvc twin, swa, pyro etc) and see how the different fixed installation cables can handle a fire, I reckon swa would hold up pretty well since there's thick layers of pvc and the armoured wires are tightly packed, you could lay them all out over some hot coals and see which wires short out our open circuit first
@jwflame
@jwflame 4 жыл бұрын
Have done some of those already, kzfaq.info/get/bejne/ac6pgZZ_tNPVd6M.html
@firsteerr
@firsteerr 5 жыл бұрын
heres the irony of FP200 it may still work after being burned BUT because its sheath is damaged and therefore no longer offers mechanical protection it is no longer valid , MICC would simply need a scrape of the dead PVC and its back in service , most electricians cant do pyro (as we call it ) these days they can barely terminate a 2.5mm SWA without taking ten hours and damaging the sheath on the conductors !!! i went to a school kitchen years ago that we had wired in MICC , we scraped the burned sheath put on new fittings and away it went , imagine the time out with FP200 ???
@charlieecosta5592
@charlieecosta5592 5 жыл бұрын
Does this cable cope with high load better than regular PVC? In a hypothetical scenario of course!
@jwflame
@jwflame 5 жыл бұрын
No, it's only rated for 70C in normal use, same as ordinary PVC insulated cable.
@DMSparky
@DMSparky 5 жыл бұрын
Canadian electrician here just curious is this used in commercial and residential environments? Is it run in a conduit or tubing of some sort?
@dglcomputers1498
@dglcomputers1498 5 жыл бұрын
Not necessarily, it would generally only be put in tubing/conduit if it was required to be hidden, otherwise it would just be fixed naked (as it were) to the wall.
@Berkeloid0
@Berkeloid0 5 жыл бұрын
Almost exclusively commercial as most residences don't have the types of systems they're used with, which are the ones that have many fire detectors, call the fire brigade automatically, switch the building aircon into exhaust-only mode, etc.
@scott198086
@scott198086 5 жыл бұрын
BS5839 calls for additional mechanical protection (conduit/trunking) for FP cabling installed below 2 meters unless it's a relatively benign environment (like an office) where it's not likely to be easily damaged
@grantrennie
@grantrennie 5 жыл бұрын
Got a knipex twiddly snipper as I call it, one turn and a bend and the alumin(i)um sleeve is off
@Petertronic
@Petertronic 5 жыл бұрын
Another excellent demonstration, and agree with you about that noise, the "angry wasp" racket that small-cc engines with insufficient or zero muffling make is quite possibly the most annoying sound in the known Universe! Especially when they are stopping and starting constantly like petrol strimmers, chainsaws etc. :)
@petertallowin6406
@petertallowin6406 5 жыл бұрын
:) brilliant video. It would be interesting to note the resistance values of a length before and after the flambé treatment.
@doktoruzo
@doktoruzo 5 жыл бұрын
Just out of interest JW, how much is this stuff and where is it made? Looks proper decent cable.
@jwflame
@jwflame 5 жыл бұрын
Size in the video (2x1.5mm) is in the area of £1 per metre. Larger sizes and those with more conductors are more. Not sure where it's manufactured, it's a Prysmian product, they have factories in the UK and many other countries.
@doktoruzo
@doktoruzo 5 жыл бұрын
@@jwflame ..thanks, very interesting
@rainplumbingrainplumbing3971
@rainplumbingrainplumbing3971 5 жыл бұрын
Will you ever Bin that Globe mate good vid as usual though
@uK8cvPAq
@uK8cvPAq 5 жыл бұрын
The flying man just wanted to be in the video!
@uK8cvPAq
@uK8cvPAq 5 жыл бұрын
The man identifying as an attack helicopter just wanted to be in the video!
@Bodragon
@Bodragon 5 жыл бұрын
Pyro. I know it so well. Not only the regular orange clad pyro but red? Oh yes, only the top clients specified red Pyro such as Halifax Building Society head office and Yorkshire Bank head office in the centre of Leeds. Yes, worked on all of those. Sadly AFA Minerva is no longer a thing. In fact, it's an absolute no-thing... ...groan...
@esuohdica
@esuohdica 5 жыл бұрын
Paramotors are actually one of the most cost effective ways to get into the sky! :-)
@michaeljohnson1006
@michaeljohnson1006 5 жыл бұрын
lol John you should have a go a paramotoring
@robertgaines-tulsa
@robertgaines-tulsa 5 жыл бұрын
You could also get the cheapest, Chinesium fire cable made of thin, iron wire and colored napalm. Okay, I seriously doubt that would pass a building inspection. Well, I doubt a flame would be applied, but the inspector would know something would be a miss when the cable spontaneously combusts for absolutely no reason at all.
@extrastuff9463
@extrastuff9463 5 жыл бұрын
Just replace the proper electrical wiring with pretty looking fuse wires for explosives (the burning kind, not electrical modern fancy stuff), the fire if it starts will make it faster to the non-functioning fire alarm possibly setting fire to more stuff along the way.
@TurboTel68
@TurboTel68 5 жыл бұрын
I used some of this recently and found when it's stripped it's got a weird smell, like a sickly sweet, almond smell
@jwflame
@jwflame 5 жыл бұрын
Almond smell = cyanide. Or perhaps not.
@TurboTel68
@TurboTel68 5 жыл бұрын
John Ward Hmm, never say never. worryingly we’ve been getting washing machine motor brushes from our supplier that emit a similar odour, assuming they buy in from China you never know what you’re getting!
@jamesrodgers3132
@jamesrodgers3132 5 жыл бұрын
Here, across the Irish Sea, it mean Semtex.
@samuelchamberlain2584
@samuelchamberlain2584 5 жыл бұрын
It is useful to test the fire behaviour of materials you install so you can be confordent that it will behave as documented / certified.
@edwinwaugh
@edwinwaugh 5 жыл бұрын
Did you forget to mention when installing make sure to use a ferrule.
@TheChipmunk2008
@TheChipmunk2008 5 жыл бұрын
They allege that you don't need them now... But I tend to use them if I can source them
@edwinwaugh
@edwinwaugh 5 жыл бұрын
@@TheChipmunk2008 How things have changed.
@andyb9049
@andyb9049 5 жыл бұрын
The first iteration of FP200 had rubber insulation for the cores and would tend to tension split if coming into contact with the sharpish edge of the aluminium sheath hence the use of ferrules, with later iteration using plastic core insulation the ferrules were deemed unnecessary
@jwflame
@jwflame 5 жыл бұрын
Ferrules haven't been required for more than 20 years.
@edwinwaugh
@edwinwaugh 5 жыл бұрын
@@jwflame I was made medically retired 23 years ago and never really kept up with what was happening in the electrical field. Just one of many reasons i enjoy your channel.
@heronimousbrapson863
@heronimousbrapson863 5 жыл бұрын
I thought the noise was a leaf blower.
@UnrealVideoDuke
@UnrealVideoDuke 5 жыл бұрын
That "Nutter" could be Colin Furze... A KZfaqr much like yourself!
@peckelhaze6934
@peckelhaze6934 5 жыл бұрын
No, it wasn't a household fan run from a moped engine.
@ambassadorfromreality1395
@ambassadorfromreality1395 5 жыл бұрын
Big Clive?
@sajad459
@sajad459 2 жыл бұрын
Hello JW, I think the third wire which is bare is for noise protection. The voltage in addressable fire alarm systems is 24 volt and the communication between panel and devices is digital ( power and data are simultaneously on 2 wires ). The system works without the third wire but since most of times these cables are near 230 volt cables, they like to be sure that there will be no noise and no interference on the operation of fire alarm system.
@nightshadelenar
@nightshadelenar 4 жыл бұрын
6:55 Huh, that is a dreadful noise.
@PhilPassmore
@PhilPassmore 5 жыл бұрын
Ah, your hobbies are ok, but everyone else should be ridiculed? Kind of spoilt the value of your presentation.
@thomasroberts749
@thomasroberts749 5 жыл бұрын
Fire Performance there is STILL ONLY MICC which will survive in the event of a REAL fire where water from burst pipes and mechanical shock movement will inevitably happen when internal structures within the environment start to move as will happen in a REAL fire. Silicon ceramifiable cables will NOT survive a REAL fire they are only meant to be used with Addressable intelligent fire panels and detectors. Clipping is important and some times clips are PVC coated with some unscrupulous manufacturers using outer sheath PVC and NOT LSF....Shame..................
@grahammuppet
@grahammuppet 5 жыл бұрын
Ventcroft is far nicer fp
@tinytonymaloney7832
@tinytonymaloney7832 2 жыл бұрын
Annoying piece of junk 😂😂😂, we used to get some twat who flew his stupid motorised kite over us and circle, its an invasion of your privacy and that ridiculous buzz...... Back to the cable, years ago we had little plastic or nylon ferrules that you inserted into the cut end of the outer sheath to prevent the hard sheath chaffing into the soft inner core insulation, then as you said, a normal flex gland to hold the cable into the terminal box.
@christopherclegg5682
@christopherclegg5682 5 жыл бұрын
That annoying piece of junk happens to be a paramotor. And its within the reach of anyone as its not an expensive sport. However, if we want to talk about annoying I would say its your commentary. Get a life dude. Best regards, "an annoying flying thing" pilot.
Old Sockets, Lamps, Plugs.  Gems or Tat?
22:52
John Ward
Рет қаралды 24 М.
The SECRETS of Making Fire Performance Cables
9:19
eFIXX
Рет қаралды 9 М.
Miracle Doctor Saves Blind Girl ❤️
00:59
Alan Chikin Chow
Рет қаралды 63 МЛН
Чай будешь? #чайбудешь
00:14
ПАРОДИИ НА ИЗВЕСТНЫЕ ТРЕКИ
Рет қаралды 2,6 МЛН
Cute Barbie Gadget 🥰 #gadgets
01:00
FLIP FLOP Hacks
Рет қаралды 38 МЛН
Rubber Flex Insulation Resistance Failure
14:07
John Ward
Рет қаралды 34 М.
The Microspheres Hiding in your Phone's Screen
11:09
Breaking Taps
Рет қаралды 776 М.
FP200 Termination
10:26
E Learning Resources
Рет қаралды 28 М.
The most deadly project on the Internet
15:14
bigclivedotcom
Рет қаралды 6 МЛН
Wheres Dave gone? and Running some FP200 | Thomas Nagy
11:18
Thomas Nagy
Рет қаралды 95 М.
Zones for Concealed Cables in Walls, BS7671 Wiring Regulations
13:35
RFID Locks are way too easy to "Hack"! Let me show you!
11:41
GreatScott!
Рет қаралды 1,3 МЛН
How standing desk legs actually work
16:54
MatthiasWandel
Рет қаралды 207 М.
Holey Plugs, Batman! But... what are they for?
20:32
Technology Connections
Рет қаралды 5 МЛН
Не обзор DJI Osmo Pocket 3 Creator Combo
1:00
superfirsthero
Рет қаралды 1,3 МЛН
How To Unlock Your iphone With Your Voice
0:34
요루퐁 yorupong
Рет қаралды 19 МЛН
cool watercooled mobile phone radiator #tech #cooler #ytfeed
0:14
Stark Edition
Рет қаралды 8 МЛН