Roy Fuglar from Viva Training Academy talks to us about electrical issues and fault finding in gas boilers.
Пікірлер: 56
@Adam-fp8jp3 ай бұрын
Great video. Really appreciate all the good content. Helping me out no end as a newly qualified engineer
@Burncash1510 Жыл бұрын
Excellent vid by roy and allen thank you both keep them comin
@d.costacostagliola72982 жыл бұрын
Top notch videos guy's, explained so well, the electrical testing is the part I've always found the hardest but that video has definitely helped.
@richardhodgson74432 жыл бұрын
Excellent video, thank you for your time and effort producing these videos
@AllenHart9992 жыл бұрын
Thank You
@hvacgas52922 жыл бұрын
Thank you, really helped me. Defo will do fault finding with viva🙏
@user-li8gr8ur8l6 ай бұрын
Thanks Allen and Roy❤ that was very interesting
@jasonwhittle50082 жыл бұрын
Great video again really informative and enjoyable to watch 👍
@AllenHart9992 жыл бұрын
Thank You
@mcginn0022 жыл бұрын
Excellent as usual guys keep up the good work !
@AllenHart9992 жыл бұрын
Thank You
@vincentmcdonnell9797 Жыл бұрын
Brilliant videos always make things exsplained really clear ,so helpfull ,thank you 🙏
@gordonmatkin93882 жыл бұрын
Great video, safety is paramount a lot of injuries through dropped neutrals. Even had reverse polarity on new builds during my stint at baxi/potterton
@AllenHart9992 жыл бұрын
Thank You
@steveincork36699 ай бұрын
Fabulous Video well done all round👍👍👍
@AllenHart9999 ай бұрын
Glad you enjoyed it
@AllenHart9999 ай бұрын
Thanks very much for your comment; please consider subscribing to support the channel 🙂
@EthnicEuropeans8 ай бұрын
excellent video. keep the good work.
@antonybuckley26452 жыл бұрын
Great info .Roy you are a legend
@user-zm1nt4tq3v2 жыл бұрын
Thank you so much for this experience 💗
@leonardbalint49302 жыл бұрын
thanks Roy, great video
@tonywardell34112 жыл бұрын
Brilliant video. Thanks v much
@AllenHart9992 жыл бұрын
Glad you enjoyed it
@vipergas55422 жыл бұрын
Great video Roy/Allen 👏🏻 ⚡
@andyfadian2 жыл бұрын
Great video gents, thank you 👏👏
@AllenHart9992 жыл бұрын
Thank You
@Roberto-yr6us10 ай бұрын
Thanks a lot. 👍👍👍🌹🌹🌹
@AllenHart9999 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@nemo92482 жыл бұрын
Always very helpful ......thank you
@antonybuckley26452 жыл бұрын
Thanks Roy and allan
@AllenHart9992 жыл бұрын
Thank You
@antonybuckley26452 жыл бұрын
@@AllenHart999 appreciate what you do mate
@baffoxxx2117 Жыл бұрын
Hello, I wanted to ask a question: In my boiler I hear a bubbling noise as if it is boiling inside the primary exchanger. Could you please help me understand the problem? Thank you
@mgbroadsterJ Жыл бұрын
Why can't boiler manufacturers design a low voltage boiler ? I'm also surprised its RDC fused spurs are not compulsory . I often see them in council properties .
@AllenHart9999 ай бұрын
Boilers are built to a price. Thanks.
@cliveramsbotty60772 жыл бұрын
10:00 CPC is Circuit Protective Conductor not 'continuous' protective conductor
@heatpump85662 жыл бұрын
Great video this 👍
@AllenHart9992 жыл бұрын
Thank You
@deniswatfordsmart10492 жыл бұрын
Banging 👍
@AllenHart9992 жыл бұрын
Thank You
@waseemkhaliq9332 жыл бұрын
Hi Allen how long have you known each other?
@AllenHart9992 жыл бұрын
I have known Roy for around 15 years or so. I have been on many of Roys training days. Thanks.
@YOUMUG5662 жыл бұрын
allen abit off topic but my boiler is blinking giving me the error code 117 2.7bar it’s nothing major i don’t think as it only does it certain days and other days it’s completely fine any help would be massively appreciated 👍🏼
@AllenHart9992 жыл бұрын
That will be too much pressure. Have you topped it up too much. Thanks.
@YOUMUG5662 жыл бұрын
@@AllenHart999 i haven’t touched it mate, it just happened out of no where
@AllenHart9992 жыл бұрын
@@YOUMUG566 Filling loop passing? Whats the pressure on when the system is cold? Thanks.
@YOUMUG5662 жыл бұрын
@@AllenHart999 pressure on the system cold is 2 and half mate
Your image at 11,57 min is misleading, I would check the source , the image is certainly a telephone pole. No power cables on this pole, communication only! and even trying to get someone to recognise the distribution system leading to a property without them having extensive power distribution knowledge is slightly imperfect to say the least. I would contact the provider of the image to ask why incorrect info is being used in training literature.
@Chatterisdotbiz2 жыл бұрын
Why would it have an insulator if it only carried telephone cables?
@AllenHart9992 жыл бұрын
I actually know the guy who took that picture and he is very experienced. The wires above are the telephone wires. Thanks.
@SuperWayneyb2 жыл бұрын
🤘😎🤘
@AllenHart9992 жыл бұрын
Thank You
@grumpygit4472 жыл бұрын
If you are not a qualified electrician do not touch electrics just as if you are not gas qualified do not touch gas