Gas Boiler Safe Isolation Tests / Checks - Day in the life of a Plumber

  Рет қаралды 15,083

Allen Hart

Allen Hart

Күн бұрын

how to carry out safe isolation of a boiler.
Safe isolation procedure for a gas central heating boiler. Boiler safe isolation. how to carry out safe isolation of a boiler. Technical bulletin 118 says you must check gas boilers when you do a boiler service or work on a gas boiler. Gas safe technical bulletin 118. socket and see tester

Пікірлер: 51
@paulrossiter9567
@paulrossiter9567 3 жыл бұрын
Quality video 👏👏👏 can’t believe some of the negative responses on here. From what I seen (I ain’t no electrician) that was perfect safety testing. Thankyou for jogging our memories and sharing 👍
@AllenHart999
@AllenHart999 3 жыл бұрын
Thanks 👍
@gm2407
@gm2407 3 жыл бұрын
a good video to know your plumber is doing it right and keeping everyone safe.
@leerussellsmith8558
@leerussellsmith8558 3 жыл бұрын
Thanks Allen for this video, and all the others. Cheers mate, Lee.
@Ellielug1
@Ellielug1 3 жыл бұрын
That was really clear and helpful - thank you
@davidceredig-evans8772
@davidceredig-evans8772 3 жыл бұрын
Excellent video. Many thanks.
@markshaw1533
@markshaw1533 3 жыл бұрын
Great video Allen, every day is a school day.
@con6951
@con6951 3 жыл бұрын
Great video helpful for students like me. Thumbs up!
@kudospremier7415
@kudospremier7415 3 жыл бұрын
Brilliant video
@heatpump8566
@heatpump8566 3 жыл бұрын
Great video Allen 👍
@AllenHart999
@AllenHart999 3 жыл бұрын
Thank you very much.
@SAS-gu9kl
@SAS-gu9kl 2 жыл бұрын
Good video boys
@michaelnaughton9911
@michaelnaughton9911 3 жыл бұрын
Alan- in the live test, the instructor talks of the neutral to earth test with 15 v induction but summarises it as a neutral to live . That it I'm still half asleep .
@vladimirstafasani4630
@vladimirstafasani4630 3 жыл бұрын
Great video well done guys
@AllenHart999
@AllenHart999 3 жыл бұрын
Glad you enjoyed it
@AllenHart999
@AllenHart999 3 жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@vladimirstafasani4630
@vladimirstafasani4630 3 жыл бұрын
@@AllenHart999 I’m already subscribed to your channel👍
@petersutton3054
@petersutton3054 3 жыл бұрын
Socket and see are good for theses tests
@johnnybarbados8211
@johnnybarbados8211 2 жыл бұрын
Unfortunately, testing 3 phase circuits to ground doesn't end well, but it's fun. I'd love to see more commercial stuff in your remit, even if it's paid for. They're good videos. Maybe explain why Evomaxs' are prone to loud noises after 2 years 😬🤷🏻‍♂️
@baffoxxx2117
@baffoxxx2117 Жыл бұрын
Hello, I wanted to ask a question: In my boiler I hear a bubbling noise as if it is boiling inside the primary exchanger. Could you please help me understand the problem? Thank you
@charlottehart4430
@charlottehart4430 3 жыл бұрын
👍🏼
@Bro-ex3su
@Bro-ex3su 3 жыл бұрын
👍
@stuartgammie1862
@stuartgammie1862 3 жыл бұрын
Daft question but how do you know if you have reverse polarity? Is the reading different to what was in the video?
@paulkelly3254
@paulkelly3254 3 жыл бұрын
I’ve got a full sheet telling you results and if you’ve got a different reading Stuart, phone was playing up so I didn’t get to that part👍🏻 I can send it you
@cumberland1234
@cumberland1234 3 жыл бұрын
If someone has swopped L&N somewhere on the supply you’ll get a reading of about zero volts between L&E, 240v between N&E.
@lizardboy0802
@lizardboy0802 3 жыл бұрын
Im more commercial than domestic and i have my head in panels everyday so I have C&G 1 and 2 in electrical. Don't you Domestic guy's have to comply to TB118? Informative video by the way for folks that don't know. 👍
@AllenHart999
@AllenHart999 3 жыл бұрын
Do you have any jobs for an old apprentice 😂😂😂
@ArksE8
@ArksE8 3 жыл бұрын
I dont know much about electricity. I just volt stick anything metal. If it bleeps I'll refer them to a sparky.
@Cardetailingburnley
@Cardetailingburnley 3 жыл бұрын
Allen I would like to assist with the multi meter video as I have got a few different meters that would be of some use
@AllenHart999
@AllenHart999 3 жыл бұрын
If you have any videos please feel free to send them on whatsapp Thanks.
@Cardetailingburnley
@Cardetailingburnley 3 жыл бұрын
Allen Hart could you email me info@lancashirepropertymaintenance.com
@michaelboyes4948
@michaelboyes4948 3 жыл бұрын
for any safe isolation you should be using an approved gs38 voltage indicator and proving unit or known source as well as locking off the supply be that using a fused spur lock off or locking off the circuit at the mcb, you can't just rely on removing the fuse as anyone can come along and throw a fuse in, also multimeters can't be used for isolation because of the chance of selecting the wrong measurement
@seandempsey7351
@seandempsey7351 2 жыл бұрын
As for not using a multimeter for safe isolation because it is easy to set the wrong range. I have to disagree, why ? Because if you’re silly enough to set the wrong range on your multimeter then your silly enough to set the wrong function on your MFT , I have seen an electrician about to do a Ze test but he set his megger 1751 on continuity and wonder why there was a loud bang followed by a big puff of smoke and sparks from from his megger and now it is in need of a very expensive repair , at the end of the day it’s easily done , but I but he won’t make that mistake a second time.
@herrklamm1454
@herrklamm1454 3 жыл бұрын
Allen can you explain why we need a two pole voltage detector AND a multimeter?
@jamesdyas542
@jamesdyas542 3 жыл бұрын
2 pole testers used for safe isolation should be GS38 compliant which a multimeter isn’t. A multimeter performs more functions than a 2 pole tester. That was what I was told last time I went on a course anyway. Hope this helps.
@cumberland1234
@cumberland1234 3 жыл бұрын
Put simply, a gs38 approved voltage indicator is the recommended tool for testing for dead. A multimeter isn’t recommended as it may be set incorrectly whereas an approved voltage indicator shouldn’t require any setting. Approved voltage indicators should be proven before and after each use, either on a known voltage similar to what you’re checking or on a proving unit. A multimeter is useful as a measuring device, i.e. for an accurate measurement of volts/amps/ohms etc.
@jamesdyas542
@jamesdyas542 3 жыл бұрын
cumberland1234 agreed excellent explanation.
@jasongeorge4602
@jasongeorge4602 3 жыл бұрын
Great video as usual mate
@TheDickPuller
@TheDickPuller 3 жыл бұрын
Thanks Paul, a couple of things; On earth continuity test the DP/Switch screws maybe screwed into a Fastfit electrical box, so no Earth connected there. I don’t think you did ‘Safe Isolation’? Also it’s always advisable to do a Loop Impedance Test on a socket that’s on the same ring as the boiler spur. Whooshitter Botch Engineer & got the scars to prove it👍👍👍
@jamesdyas542
@jamesdyas542 3 жыл бұрын
If the spur is screwed to a plastic box you should still get a reading on both of the screws on a good quality one. Have seen some spurs and 20 a switches where only one screw is connected to the earth terminal though. Don’t think I’ve seen one without any link between the screw and the earth terminal apart from a light switch.
@mgbroadsterJ
@mgbroadsterJ 11 ай бұрын
I'm all for safety but will the customer be happy to pay more ?
@AllenHart999
@AllenHart999 8 ай бұрын
Why would they pay more?
@kelvinellis9155
@kelvinellis9155 3 жыл бұрын
Shouldn't the tips on those probes be more insulated?
@lizardboy0802
@lizardboy0802 3 жыл бұрын
Well done lad. Ya are completely right. Those probes don't comply with IEC 61557.
@seandempsey7351
@seandempsey7351 2 жыл бұрын
@@lizardboy0802 or GS38
@kippers32
@kippers32 3 жыл бұрын
Sorry to poo poo Alan but it’s all a bit flaky , can you link up with sparky ninja on this (FB) , they will help on a better step by step Guide , just trying to help ,
@salandjim
@salandjim 2 жыл бұрын
Where in TB 118 is the as operative instructed to perform a 'safety toch test' or an earth loop impedance test or a polarity test - the ONLY 'procedure' derined in TB 118 is the Safe Isolation procedure ! This video does nothing more than add to the confusion within the industry because TB 118 is ill-conceived, misguided, misworded, inaccurate and contains an unforgivably dangerous bunch of words - it should be no more than 2 pages long and explain what is in the title of the TB - a SAFE ISOLATION PROCEDURE ! The objective is simple - prove the test gear good, isolate the appliance, prove the appliance is dead and then perform a confidence test of the equipment to prove it is still good. Th edocument has opened the flood gates for test gear manufacturers to sell kit for checks that are NOT required to keep the gas operative safe ....
@QsKIIHALOIIWoWII
@QsKIIHALOIIWoWII 3 жыл бұрын
Where’s the cigarette lighter
@lucygames8198
@lucygames8198 3 жыл бұрын
👍🏻
Gas Training - Understanding Electrics in Gas Boilers
28:01
Allen Hart
Рет қаралды 12 М.
- А что в креме? - Это кАкАооо! #КондитерДети
00:24
Телеканал ПЯТНИЦА
Рет қаралды 5 МЛН
Who has won ?? 😀 #shortvideo #lizzyisaeva
00:24
Lizzy Isaeva
Рет қаралды 61 МЛН
WHO LAUGHS LAST LAUGHS BEST 😎 #comedy
00:18
HaHaWhat
Рет қаралды 19 МЛН
How To Fill Out A Landlord Gas Safety Check CP12 GGIUR 26.9
38:42
Gas Training - How To Test A Boiler Fan - Combi Boiler
22:58
Allen Hart
Рет қаралды 72 М.
What is a CP12? Landlords gas safety check
8:43
Central Heatking
Рет қаралды 3,4 М.
Regulation 26.9 Gas Engineer Safety Checks | NGCFE
17:04
Allen Hart
Рет қаралды 41 М.
Lockdown Learning - The recommended basic electrical safety checks you should perform
9:11
Baxi - sustainable heating and hot water solutions
Рет қаралды 26 М.
Electrical safe isolation procedure - Single Phase
8:01
Residual Electrical
Рет қаралды 15 М.
HAPPY BIRTHDAY @mozabrick 🎉 #cat #funny
0:36
SOFIADELMONSTRO
Рет қаралды 8 МЛН
who is the champion of ludo luck balloon popping race ?
0:59
SS FOOD CHALLENGE
Рет қаралды 50 МЛН
10000000❤️ #shorts
0:20
北出 大周 Kitade Taishu
Рет қаралды 9 МЛН