GUILTY MISTAKES! Too many electricians do this wrong!

  Рет қаралды 109,937

Artisan Electrics

Artisan Electrics

Күн бұрын

GUILTY MISTAKES! Too many electricians do this wrong!
From job to job we tend to see the same old simple mistakes made by lazy electricians. In this episode, we return to the job where John expressed his opinion regarding the current state of the electrical sector. The point is proven more, showing how easy it is to not make these mistakes and just take pride in your work.
Our Apprentice Reuben is also on-site showing off his skills, updating a super retro consumer unit in the garage. Let us know of any other common mistakes you always seem to come across in the comments below.
🚨Subscribe to our KZfaq Channel for more great electrical content: kzfaq.info...
➕Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
💬Artisan Electric Discord - Join our Electrical Community! 👇
/ discord
⏱️Timestamps
00:00 Would You Know?
03:40 Under Lock & Key
05:13 Gloving Up
07:04 Eyesight Is Overrated
09:03 More Mistakes
12:46 Chefs Table
15:21 A Question For You
17:49 Pokemon
20:44 Apprentice Check Up
22:26 Eagle Eyes
26:06 Bonus Clip
🔦Unilite Work Lights:
Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
🕶 SafeStyle Protective Eyewear - bit.ly/3Svl4xG-SafeStyle Use code 'ARTISAN10' for 10% off
🏷️😱 Big Boots - get 5% off our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
-----Electricians Business Course-----
📩 Sign Up To The Electricians Business Course Here And Get The First 4 Lessons Free 👇
➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS KZfaq Channel 👇
We Also Have A Dedicated KZfaq Channel About Tools:
➤ / tools4sparks
-----MY ENERGY PROVIDER-----
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📈Make the most of your KZfaq analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
💬 Artisan Electrics Discord
➤ / discord
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер: 244
@cjmillsnun
@cjmillsnun Жыл бұрын
Great reminder to Reuben about proving dead. And John's comnment about not having an apprentice work on it without him touching it first. First class.
@jimosullivan1389
@jimosullivan1389 Жыл бұрын
Fist class ? Really....touching to prove dead !!! What sort of Moron are you and him ?
@matthewseymour8972
@matthewseymour8972 Жыл бұрын
Came here to make that comment... And it isn't a lack of trust in Reuben, it's a proof of duty of care.
@patrickcannell2258
@patrickcannell2258 Ай бұрын
Done the same for 35 years. Test to be dead, then touch. HV applications, or large LV busbars, I apply an earthing device. Safety paramount.
@TheOriginalCoda
@TheOriginalCoda Жыл бұрын
"I won't have an apprentice work on it without me touching it first". You are an A+ gentleman. Wish there were more like you in this world.
@5pr1nk57
@5pr1nk57 4 ай бұрын
Yeah that stood out to me, along with saving the moth. Guy just seems a generally good egg 🙂
@adammm8964
@adammm8964 Жыл бұрын
John is just a good all round sound guy isn’t he. Great signing from Jordan !
@artisanelectrics
@artisanelectrics Жыл бұрын
Second that ☝🏼
@m.bmaintenance7834
@m.bmaintenance7834 Жыл бұрын
As I tell my apprentice, its not always a problem when you make a mistake, its more important you know how to fix it, well done on the board reuben
@artisanelectrics
@artisanelectrics Жыл бұрын
Great words!
@ericmcrae7758
@ericmcrae7758 Жыл бұрын
John making sure it was dead before Reuben worked on it reminded me when I worked with a very old Electrician 60 years ago - He wanted to test if a light fitting was dead and stuck his thumb where the lamp went touching the terminals apprently his skin was so dry all he got was a tingle he said to me "DONT YOU DO THIS SON" its funny how you never forget some things.
@raychambers3646
@raychambers3646 Жыл бұрын
I worked a guy like that , being a bit young , I put it down to no sense no feeling !
@richrowley8355
@richrowley8355 Жыл бұрын
I think John is a natural. really like content with him in. Same with Lee. I think John is a perfect mentor for Reuben. Nice board change Reuben
@JoshMurphyDrums
@JoshMurphyDrums Жыл бұрын
Reuben is on route to be the new Corey in years to come I reckon I also love how thorough John is, respect! I thought I was a bit hard on things but... better up my game!
@stefan-ox8qs
@stefan-ox8qs Жыл бұрын
I worked for a diverent industrial cleaning companys and some just where very straight to the point and tell you what went wrong. And others where all good and well done types bud when your where gone there told everyone how stupid you where. Yes i have my fair share of fck ups, but i rather have a "grumpy" person that is honest and respectfull than those "nice" ones that stab you in the back. So beeing hard is not bad solong it is in a respectfull and meaningfull way.
@lawrencetasker212
@lawrencetasker212 8 ай бұрын
Sorry but Ruben will never be the new Corey
@nmccw3245
@nmccw3245 Жыл бұрын
Excellent board swap, Reuben. I’m always amazed by John’s knowledge and how good he is at instructing. Great team work guys! 🇬🇧👍🏻
@christopherhulse8385
@christopherhulse8385 Жыл бұрын
Rewireable fuses were abused so much, even copper wire used instead of the correct fuse wire! There are still millions of these Wylex consumer units still in use today, I fitted one last around 1989 - 1990 when MCBs started to come in.
@tawnabandicoot6567
@tawnabandicoot6567 Жыл бұрын
I agree, those old boards were abused. I'm just old enough to have heard about these old fuse boards. The worst I've heard someone doing with these boards is someone went as far as sticking nails and/or screws into the board to stop it from tripping. If a board keeps tripping or a fuse keeps failing, find out what's causing the fault and rectify the fault instead of creating a fire hazard!
@joe2395
@joe2395 Жыл бұрын
Being old school we always left a card of fusewire next to the board , the reason they are still about speaks for itself,never had trouble with burnout's like the new board's
@christopherhulse8385
@christopherhulse8385 Жыл бұрын
@@tawnabandicoot6567 definitely seen nails, foil, anything to keep the power on! many house fires back in the day traced to these kinds of bodges.
@johnavery15
@johnavery15 Жыл бұрын
Great work Reuben. The only way to learn is to do it yourself and work through issues/problems on your own.
@Chris_In_Texas
@Chris_In_Texas Жыл бұрын
John, would be really nice on board changes to add an emergency light when CU's are under stairs etc. If they lose power, the light would come on and at least that way people can check and see if the breaker tripped. 👍😎 Would be a nice value add for Artisan.
@rsmckgla
@rsmckgla Жыл бұрын
Glad I'm not the only one that does this ... people who bought my last house were completely confused by the green glow but then when demonstrated "wow, why doesn't everyone do that" ... why indeed, the cost is tiny these days!
@travoltasbiplane1551
@travoltasbiplane1551 Жыл бұрын
Hope you did an emergency lighting cert 🤣
@radders261
@radders261 Жыл бұрын
There must be many electricans out there watching this channel hoping that they will end up with an apprentice like Reuben. Fair play bud! And what a team, John makes a wonderful mentor for Reuben. Brilliant, simply brilliant!
@93lornamae
@93lornamae 4 ай бұрын
I'd say apprentices like Ruben are very rare.
@eamonnohalloran2254
@eamonnohalloran2254 Жыл бұрын
good one John and Reuben. Glad I called the Talc the other day. When you were replacing the wire in the garage. Did you think of coming out of the bottom of the boxes and doing two back to back 90's into the consumer unit. it would have given you a little more room to work and removed that tight swanneck. All in all i love that Reuben is confident and actively learning form all his journeymen, Even an Nature segment in Honour of "Dad". "Fly away butterfly" No creatures were harmed in the making of this video.
@therealdojj
@therealdojj Жыл бұрын
the bang needed to be followed by a pump of smoke and then ruben poking his head around the door with his face all sooted up and hair standing on end 🤣
@alsanova
@alsanova Жыл бұрын
😂😂
@brendenpalmer9533
@brendenpalmer9533 Жыл бұрын
In future you should use flat profile glands with a double insert to install two twins into one gland. Looks better and creates a better seal.
@peterwalton1502
@peterwalton1502 Жыл бұрын
You are a good teacher John. Ruben will be an excellent electrician 👏👏👏
@granthocking7083
@granthocking7083 Жыл бұрын
Good work John , teaching the right way from the start , Reuben is lucky to how a good teacher
@ianbird6997
@ianbird6997 Жыл бұрын
Amazing work guys 👍👍👍 Reuben really has come on so much since he started. I am the same when I am dressing in data racks OCD kicks in with the straightness of cables 😂
@RichardArblaster
@RichardArblaster Жыл бұрын
Great video guys 😎
@stuartthespark
@stuartthespark Жыл бұрын
Reuben is progressing, will be getting his own van soon. Question; my understanding of outbuildings fed by a PME supply, is that you do not connect the earth or armouring at the shed side, terminate into a plastic box and then drop in a earth rod. If the PME is broken then the shed has it's own path to earth. Similarly what you do with the car chargers you install.
@deang5622
@deang5622 Жыл бұрын
I disagree. The earthing rod strategy is never going to be as good as using the protective earth conductor back to the consumer unit . In fact I was taught it is acceptable to use the steel armour on SWA cable so long as it meets the cross sectional area requirement and thus provides a low enough impedance path. So my approach would be, use a dedicated earth conductor to the shed, or use the armour of SWA and connect that up to loads in the shed. That would be the primary earthing. Then as a backup I would be using an earth rod and suitably installed and resistance measured so it conforms to the maximum impedance permitted. Then if there is a break in the earth from the main consumer unit to the shed, the earth rod will take the current and hopefully trip the breaker. But I'd be putting in an RCD to protect the circuit at the consumer unit end, so I'm not convinced the secondary earthing using the earthing rod is required.
@stuartthespark
@stuartthespark Жыл бұрын
@@deang5622 my question relates to a PEN fault, if there was a break in the neutral/earth supply and a fault occurred in the shed then the RCD in the shed would not trip. This is why an earth rod is fitted at the shed SWA The swa armour and the earth conductor in the swa cable are connected together at the shed, but not to the shed. This can be fed by a mcb if suitably installed. This is part of the house electrical system. Earth Rod Connected to the shed MET, reading max 200 ohms, happy with 75 ohm. This is separate from the house. I'm aware that the 18th edition is recommending that a rod is now installed with a PME system at the house side. Gives an indication of the trust the DNO have in their PEN system. Has the outbuildings regs changed that we are now fitting a dual earthing system? Would that type of system backfeed a fault into the house via the earth conductor, if there was no rod? Should Artisan have fitted a rod at the house side? The ideal solution would be, rod at the house and shed, sub main to shed seperated at shed side. Or Fit a PEN detector and rods so you would have a dual earthing system with an electronic alert, with surge and hager bluetooth AFDD system. It's getting costly..
@thecomander466
@thecomander466 Жыл бұрын
I am electrician in Australia,was curious about what these common mistakes were going to be,am relieved to find out I have same work ethic as artisan electrical
@andrewpowell6457
@andrewpowell6457 Жыл бұрын
Well done Reuben & John lovely work
@trevorlewis2758
@trevorlewis2758 Жыл бұрын
Good work Reuben!
@jacabaca7440
@jacabaca7440 Жыл бұрын
21:25 If this is TNCS system ,shouldn't the incoming SWA earth be isolated from the CU in the shed and CU connected to the earth electrode? In case of PEN fault?
@travoltasbiplane1551
@travoltasbiplane1551 Жыл бұрын
Is this a troll? 🤣
@johnbrown-so3vz
@johnbrown-so3vz Жыл бұрын
Nice to see the testing done well. We as an industry must drive out the drive by guys.
@JensenPGATourDriven
@JensenPGATourDriven Жыл бұрын
Great Content guys , well done Reuben on the Board change A1 ⚡️👊
@CameraTimDotCom
@CameraTimDotCom Жыл бұрын
I think "efficiency" was the word he wanted instead of shortcut, learning good ways to do things
@uksds3806
@uksds3806 Жыл бұрын
Love this video!
@tmaster.6069
@tmaster.6069 3 ай бұрын
When coring holes through brick, make a pilot hole, then core hole from each side, it won't leave a messy broken plaster wall to make good. The same with breaking exterior brick.
@mickletterbox
@mickletterbox Жыл бұрын
Ive been an electrical engineer for 12 years at great places and am just moving to installation full time Instead right now and enjoying the change fav thing is everything I do is how I decide now and planned by me.
@neilstokescvwshrewsbury7939
@neilstokescvwshrewsbury7939 Жыл бұрын
Great video both 👍
@philipsmith0752
@philipsmith0752 Жыл бұрын
interesting job , John and Reuben
@seantaylor9758
@seantaylor9758 Жыл бұрын
Working with some of the old open breakers in a power room was always a challenge. Just keep your paws away from the live you will stay safe! It's strange really how the old stuff was built to last but no modern protection but I dont really recall any issues but then again lots of customer used to call it the electric light company so that was that.
@alsanova
@alsanova Жыл бұрын
Reuben is doing so well and getting better every time, good job on board change 👍👌 20:15 - 👀 Lol, that's a massive blow out! Who done that?! 😂
@roydowling2542
@roydowling2542 Жыл бұрын
18:32. One of the two mentioned
@Omey731
@Omey731 Жыл бұрын
DIYer here, in my bad experience almost every electrician I got made almost fatal mistakes so I decided to go diy! last week I installed henley blocks, a new consumer unit for a tesla EV charger, migrated the aircon and shed from the old consumer unit to the new ev one, installed pen fault and the usual shibang - had I trusted the dodgy electricians I got my house would be on fire now. honestly i got so fed up from cowboy electricians ! I called your company actually to get you to do some work for me in the past but sadly you do not cover Surrey :( maybe someday!
@artisanelectrics
@artisanelectrics Жыл бұрын
Crazy these people are so called ‘qualified’
@lavectech
@lavectech Жыл бұрын
Great video
@michealplater9007
@michealplater9007 Жыл бұрын
The same thing happened to me with the light fault. If the wires are joined together, do not undo them. The home owner decided not to stop at one light but to do the whole house. He did a better ,job in blowing the fuse when the light was turned on.
@buixote
@buixote Жыл бұрын
Wondering about the shots of the gas and electrical equipment so close together . We were upgrading our main panel to 200a here in California, and the electrician talked about needing to have the electrics much further away from the gas meter... And this was *outdoors*. How does the UK manage to avoid more fires... Am I missing something here?
@THECALLOF241
@THECALLOF241 Жыл бұрын
The minimum distance under British regs is 150mm (6 inches) between gas supplies and items such as electricity meters, boards, sockets and the like. Surely even if you separate them outside there's gonna be some points inside your house where they're somewhat close together?
@timbo19
@timbo19 Жыл бұрын
It's just a matter of varying regulations/codes which can be due to historic reasons and are not always rational when compared. Gas pipes don't spontaneously leak, nor do electric cables spontaneously strip themselves and short out, so unless damaged or poorly installed there is no problem.
@alanjrobertson
@alanjrobertson Жыл бұрын
Another great video from John & Reuben - amazing how far Reuben has come, also great he's been taught the importance of trying to make it all look neat and tidy. I thought the reflection on apprenticeship at 16:01 was spot on too - it applied in other professions as well; learn from good teachers and build your own style taking all the things you like from each of them 👌👍
@artisanelectrics
@artisanelectrics Жыл бұрын
Great spark in the making!
@davedrew9328
@davedrew9328 9 ай бұрын
Ruben’s on fire he is really good how many years is he into his apprenticeship ?
@sg403
@sg403 Жыл бұрын
I always wanted to be an electrician but I never knew electricians like John existed. A guy with a lot of knowledge who is very happy to share it with his apprentices. I always had the image of the guy who treated the apprentice like crap, gave them crappy jobs never wanted to teach them anything. Maybe I should have looked harder but at 40 it’s probably too late.
@rattlehead85
@rattlehead85 Жыл бұрын
That scenario still exists in many companies and sadly Artisan are an exception rather than the rule. Rueben has landed himself with a good employer and will benefit greatly from the knowledge available to him. I have actually seen young apprentices given a test kit and thrown out on site with an ipad and told to churn out 10 eicrs a day as they are all the same. Firstly they have had no proper training and been shown with a quick 15 minute demonstration and secondly the companies aren’t bothered as they continue to wing it until something serious occurs at which point it becomes a blame game.
@artisanelectrics
@artisanelectrics Жыл бұрын
He’s amazing!
@Havoc4Hire
@Havoc4Hire Жыл бұрын
13:15 Rueben - I appreciate this, i am going to start making a constant effort to do this. btw been an electrician for 10 years and still learning every day
@Etacovda63
@Etacovda63 Жыл бұрын
Use a tool belt, it’s 100% better than this method because you don’t rely on having a flat surface. You can get pouched tool belts that you can disconnect for situations that require it.I use toughbuilt.
@Havoc4Hire
@Havoc4Hire Жыл бұрын
@@Etacovda63 the problem with a toolbelt for me on service side is it make me to wide and i dont want to scratch a wall or hit a something
@Etacovda63
@Etacovda63 Жыл бұрын
I used to work in peoples houses as a contractor - if you get the right tool belt it wont be a problem. As I said, I use the toughbuilt cliptech system. The useful part is the clip system in which you can move the pouches around, I just put a clip on the front, one on the rear and one on the side - If i had to walk through a place with finished surfaces I just moved the tools to front and back.
@michaelbarlow3686
@michaelbarlow3686 Жыл бұрын
Great Tuition From a Sparks retired after 45 Years
@Shocker99
@Shocker99 Жыл бұрын
17:45 I literally just watched ResidualCurrent do the 2 part video of him and another do one of these joints - just with 3 phase 240mm^2 and 185mm^2 cable instead.
@patriciamenhennett2035
@patriciamenhennett2035 Жыл бұрын
In Australia it is mandatory that an apprentice is continuously supervised not just checked on every now and then
@jamiegoulding5943
@jamiegoulding5943 Жыл бұрын
I see a lot of the locations your people go so can’t understand when my mother in law approached you for solar in Attleborough you said it was to far out of the way 😂 love your work
@pezzermra
@pezzermra Жыл бұрын
I preferred installation over testing. Testing can be very time-consuming.
@desmondyoung5963
@desmondyoung5963 Жыл бұрын
What about mechanical protection. In a shed it chould be wired in conduit to give protection against shovels etc that are mounted on a nailalong side where the cables run?
@PaulsRoadshow
@PaulsRoadshow Жыл бұрын
Exactly my thoughts!
@richieb879
@richieb879 Жыл бұрын
Go easy with the talc powder , ask someone from occ health about its issues. Anyways love the vids , teaches me loads with my limited electrical experience .
@Swe3ets
@Swe3ets Жыл бұрын
Isn't that odd? The basic insulation is an issue above the lights, but in the shed the cables have no protection from the Socket to the sub board. The unprotected cables are more likely to cause harm, as a sharp tool or the like could fall and damage them.
@grahamek86
@grahamek86 Жыл бұрын
Basic insulation is a single layer. The T&E cables in the shed are double insulated. Exposed basic insulation is more vulnerable to mechanical damage from screws / nails etc. The design of T&E is that the centre conductor is CPC so if there is any compromise of the cable then either live or neutral will short to earth and trip the breaker.
@peterpuchalski817
@peterpuchalski817 9 ай бұрын
@ Swe3ets ... I agree with your thought process. You can run T&E clipped to a wall if it is unlikely to get damaged by impact or accident. hidden in the fabric of the building, such as in ceilings and walls it should always have an extra sheathing. It would have been easier to put the T&E in some conduit or trunking. it wouldn't have taken too long to do and would look nicer. this is one of my gripes with Artisan Electrics, they claim to be "high end" or better than the rest but still makes poor work in parts that are easy to do. generally though their work is to a pretty good standard. but then so should every Electricians work!
@johnbrown-so3vz
@johnbrown-so3vz Жыл бұрын
No they DID NOT make it a PME system the PME is external to the cut out. They supplied a TN-C-S supply.
@tc6907
@tc6907 Жыл бұрын
Do you guys always C2 basic insulation? I will always if the accessory is accessible like a socket or switch but always struggle to code the downlights
@neilduran7647
@neilduran7647 Жыл бұрын
Another point to mention is too check the installation of the smart meter and isolation switch.
@michaelcharters5727
@michaelcharters5727 2 ай бұрын
My Favorite part Ohms Law,,,,,,,,,,,,,,,Going Home the best law.
@mos8541
@mos8541 Жыл бұрын
without a doubt i would know the back of my hand, tho MANY have seen it up close also, briefly however
@mikey4406
@mikey4406 Жыл бұрын
Good video
@dave-d
@dave-d 10 ай бұрын
Well done Reuben. The last video I watched looked like you were on day one and looking like a rabbit in the headlights. You have come a long way. You have some top teachers mate. One tip - never hold a conductor by the bare end when on a step ladder. Don't ask me why I said this! Ho ho. Good work all round. Arty sparkys indeed.
@Lenny-kt2th
@Lenny-kt2th Жыл бұрын
Interestingly enough, our old colours were a bit less logical IMHO. Green for L, red for N (yup!) and grey for PE. The one that didn't change: black for switched L (no, we don't do switched sockets, we don't do fused plugs, we don't polarize on single phase and we don't do rings.
@edknight1982
@edknight1982 Жыл бұрын
Looks a nice neat job
@artisanelectrics
@artisanelectrics Жыл бұрын
Thanks Ed!
@houseonthehillhomebrew4617
@houseonthehillhomebrew4617 Жыл бұрын
Mise en place.... in it's place., or something like that. Former chef, now trainee electrician. Wish my van was as organised as my kitchen workspace, but getting there! needs similar amounts of shelving and racking and we'll be good.
@CurtainFlapper
@CurtainFlapper Жыл бұрын
@Jordan Atrisan Electrics, just asking a bit of advice. When solar panels are fitted to a property do they power direct back into the grid or do they store the power into internal batteries? My parents have a 2 bedroom bungalow with solar panels on the roof, the panels have been there about 8 years. When the electric prices went up a few months back they had a smart meter fitted. Their bill is £160 a month for electric, they are low users as they are pensioners and sit in the garden most days, they don't have an electric vehicle. I'm wondering if the "smart" meter has been installed wrong and they are being charged by the meter for electric that the solar panels are generating aswell as being charged for just the power they're using, I'm wondering if there's a way to "turn off" the solar panels for a few days or a week to see if the meter charges are higher or lower. If the power is stopped going to the grid then the bill will rise in theory but if the cost drops then this shows they're being charged for the power the panels are generating. Can you give any advise? Thank you, Neal
@grahamek86
@grahamek86 Жыл бұрын
Any excess power not consumed by the property will feed back to the grid. There will only be batteries of the installation was specified with them.
@rondo122
@rondo122 Жыл бұрын
Reuben became a master electrician!
@connorgrobler6824
@connorgrobler6824 Жыл бұрын
have you ever thought about taking on foreign apprentices. if so I am interested in doing an apprenticeship in the UK
@cameron4081
@cameron4081 Жыл бұрын
On the new tails you have ran in, you have used all round band. Can this be done as I thought it had to be non-conductive clips?
@glynnmorris2667
@glynnmorris2667 Жыл бұрын
With rubber nails?!
@spamhead
@spamhead Жыл бұрын
Most switch feed mistakes I have seen instantly knock out the trip! My first question is, “which light did you work on?” 😂
@stephen271
@stephen271 Жыл бұрын
Really like John how he teaches top tradie 👍
@zombienation68
@zombienation68 Жыл бұрын
Standard practice with the 15A fuse wire in the carrier...ALWAYS the 5A wire is missing from the card 🤣
@protectiongeek
@protectiongeek Жыл бұрын
Enjoyed the video, thank you. Does the service cablehead relocation not change the supply from TN-S (SNE) to TN-C-S (PME)? If the supply is now TN-C-S, the sizing requirement for the CPC of the distribution circuit to the garage will have changed (BS7671 Reg 544.1.1), which *_may_* require the installation of a new main bonding conductor for the distribution circuit. Was that considered in this case? Just askin'. Also, I see that John wears light eye protection all the time. A good habit that Reuben could adopt while keeping in mind that eye protection is always required when using power tools.
@glynnmorris2667
@glynnmorris2667 Жыл бұрын
What bonding did you see in the shed?
@davidclarke2513
@davidclarke2513 3 ай бұрын
Im old enough to know even older colours which were Red,White,Blue as i was an industrial sparks for 50 years and retired in October 2020
@danyates6598
@danyates6598 2 ай бұрын
No way
@christopherhume8896
@christopherhume8896 Жыл бұрын
Don't like seeing flex used when it's not needed. If the two T&Es are long enough just put them straight into the downlighter, they normally have enough space. Means less connections hidden above the ceiling.
@declang565
@declang565 Жыл бұрын
Great job, but no surge on shed DB ?
@manresaelectric
@manresaelectric Жыл бұрын
your material looks way more fun than ours in the states lol
@jordanspencer5101
@jordanspencer5101 Жыл бұрын
10:23 always careful removing old fuse cartridges, check they aren't asbestos arc shields!!! Should bee fine aslong as its not disturbed or broken anyway but better safe then sorry...
@GregNow
@GregNow Жыл бұрын
17:57 is there minimum depth for thoise to be put in?
@IronBear88
@IronBear88 Жыл бұрын
25:42 shouldn't the cable's main insulation lead all the way into the consumer unit? I just ask because that's how I was taught in Eastern Europe.
@christopherhume8896
@christopherhume8896 Жыл бұрын
Screwfix do thin blue insulated gloves that I always use on a board which might have anything live. Saved me a couple of times. Also keeps your hands nice and soft. 😁
@PaulsRoadshow
@PaulsRoadshow Жыл бұрын
In the garage from the new consumer unit to the socket didn’t you use a piece of plastic conduit from the consumer unit and a 90° bend into the 13A socket Patris? Neater than clipping those two wires ? A 2.5 t&e and 1.0 t&e will fit into a piece of conduit :-)
@THECALLOF241
@THECALLOF241 Жыл бұрын
Looks like the wiring to the rest of the garage is just clipped direct, doesn't seem much point doing a conduit run for just the first legs
@PaulsRoadshow
@PaulsRoadshow Жыл бұрын
@@THECALLOF241 it’s only one socket and one light? I would have at least put a vertical piece up from that light switch also for added protection !
@PaulsRoadshow
@PaulsRoadshow Жыл бұрын
As for the price of that expensive metal clad consumer unit I don’t understand why they didn’t spend a few quid on a bit of plastic trunking would’ve made the job look a whole lot more neater and professional!
@THECALLOF241
@THECALLOF241 Жыл бұрын
@@PaulsRoadshow I get what you're saying but the light install wasn't their circuit to touch, you don't go into a job and start ripping out compliant work done by someone else just to make it look nicer unless you're asked to by the client.
@PaulsRoadshow
@PaulsRoadshow Жыл бұрын
@@THECALLOF241 very true
@oddlee5825
@oddlee5825 Жыл бұрын
Got a Electrical problem related questions. Where can I contact you guys.
@PT4LifeYO
@PT4LifeYO Жыл бұрын
What Box was used for the Wagos in the ceiling?
@dhutch2000
@dhutch2000 9 ай бұрын
Seems overkill to have a CU in the shed for literally one socket and one light. Why bit just wire direct to the socket with an fcu for the light circuit?
@chas3997
@chas3997 Жыл бұрын
I think what’s not mentioned here is how the DNO fail to work efficiently with electricians and quiet often fail to update their equipment ! They work on +2 weeks lead time on a call out and if your changing a consumer unit and need the main fuse removed the lead time on the job makes it impossible ! I have training on pulling the main fuse from meter companies but most electricians don’t ! Legal only a DNO can remove that main fuse but we know other unauthorised electricians sometimes do! Which can be dangerous if you don’t know what your doing!
@tonyfrewin4822
@tonyfrewin4822 Жыл бұрын
Another thing to look out for on the old Wylex fuses, is the little insulated disk covering the brass screw missing like on your 15 A one. Seen that so many times. Easily touched when pulling the fuse.
@stuartandrews4344
@stuartandrews4344 Жыл бұрын
Miss the old colours of red,yellow & blue, can never understand why having harmonised colours introduced in 2004
@geoffyoung3874
@geoffyoung3874 Жыл бұрын
Should the new fuse board be mounted on a non flammable surface and not on wood?
@nzspambot
@nzspambot Жыл бұрын
Love the blowout at 22:04 so much for OCD
@artisanelectrics
@artisanelectrics Жыл бұрын
😩
@mikethemask1525
@mikethemask1525 Жыл бұрын
What was the reason for the head to be moved outside?
@thomasamsterdam
@thomasamsterdam 9 ай бұрын
Never seen these battery powered meter testing devices. How are they called?
@NC-fe3tc
@NC-fe3tc Жыл бұрын
Think you forgot to sleave the red cable on main swa to garage at new consumer unit main switch that's after telling your apprentice what a good job he has done
@tobyprior8839
@tobyprior8839 Жыл бұрын
Going to have to mark you down on your job John I'm afraid. You fit a nice new piece of board to fit the consumer unit to then at 25:42 you can clearly see a plug socket over hanging the edge of it. Inronic considering the title of this video! Good job on every thing else thlough 👍
@krissybufton
@krissybufton Жыл бұрын
Not really an issue though is it, that was probably a temporary socket
@tobyprior8839
@tobyprior8839 Жыл бұрын
@@krissybufton I guess you don't take pride in your work then?
@krissybufton
@krissybufton Жыл бұрын
@@tobyprior8839 it’s too easy to be a keyboard warrior! If A temporary socket overhanging the edge of the board a little bit is enough to make you this upset then I wish I had your life as you’ve clearly got it made
@tobyprior8839
@tobyprior8839 Жыл бұрын
@@krissybufton your making a lot of assumptions. If my answers frighten then then stop asking scary questions!
@krissybufton
@krissybufton Жыл бұрын
@@tobyprior8839 you’re a barrel of laughs! I bet trades add a special tax when doing jobs for you
@krissybufton
@krissybufton Жыл бұрын
Hahaha what is it about touching it with your hands to double check it’s dead. I do it all the time and even though I know it’s dead I still gingerly touch it to check 😂😂
@artisanelectrics
@artisanelectrics Жыл бұрын
😳
@krissybufton
@krissybufton Жыл бұрын
@@artisanelectrics don’t pretend you don’t do it 😂😂
@MikeSmith-tx2lp
@MikeSmith-tx2lp Жыл бұрын
What enclosure did you use for the fistful of WAGOs that Ruben was debugging in the hallway at the end, or were they just stuffed back where they came from ?
@lewis94uk
@lewis94uk Жыл бұрын
Wagobox ted
@MikeSmith-tx2lp
@MikeSmith-tx2lp Жыл бұрын
@@lewis94uk Ted ? Is that a typo?
@derekgoodwin6646
@derekgoodwin6646 Жыл бұрын
No a good job at all rough .
@tobysherring1369
@tobysherring1369 Жыл бұрын
Wondering you went for such a large board in garage? On that incomer, could/would four new circuits ever be added? Why not, say, a three way with one spare?
@heladas90
@heladas90 Жыл бұрын
Because those fuseboxes are very good value for money about £50 for that size consumer unit.
@tobysherring1369
@tobysherring1369 Жыл бұрын
@@heladas90 a 4-way is under £30.
@garethfraser5211
@garethfraser5211 Жыл бұрын
Talk about making the extra effort, then you clip the cables direct into the double socket and light switch in the garage, looks pants. Would of deffo used conduit and metal clad accessories.!
@joaosidonio7562
@joaosidonio7562 Жыл бұрын
I don't quite get the logic of having metal boxes for garage consumer units and then having to earth them because they are made of metal.
@simonfranklin7659
@simonfranklin7659 Жыл бұрын
Never see you guys rushing or stressed out with time constraints on a job. Was an approved electrician, controls sparky and panel builder for decades .Time on jobs was always tight and towards the end getting plain silly leading to total exhaustion, especially on industrial and commercial.
@mike-ology22
@mike-ology22 Жыл бұрын
So fixing other people's mistakes, do you charge the customer to redo all the work to make it look neater and more professional, or do you do it out of your own goodwill to point out the bad workmanship?
@wubbo73
@wubbo73 9 ай бұрын
Are you allowed to put 2 cables in 1 cablegland, gableglands are made for 1 cable only?
@shaniapearcey
@shaniapearcey 8 ай бұрын
No
@cuezed
@cuezed Жыл бұрын
Can see the camera man at 18:03 👍🏼
@artisanelectrics
@artisanelectrics Жыл бұрын
😎
@electrickal1
@electrickal1 Жыл бұрын
That's the reason we use twin brown cables to switches. That switch wire should have been replaced, rather that sleeving the black conductor with brown tape. AND I bet you didn't remove the switch and sleeve it there too.
@andywillis856
@andywillis856 Жыл бұрын
That’s all well and good for new installs and rewires but not for remedial works etc so your saying you should change switch lines on every job you visit to replace or repair fittings
@user-um1yu6zy5o
@user-um1yu6zy5o Жыл бұрын
Great to see Reuben back. Jordan, could say us what actually happened to Oscar? Have you sacked him?
@artisanelectrics
@artisanelectrics Жыл бұрын
Something to do with a UFO and Aliens 🥲
The Toughest Solar Installation We've Ever Done!
40:11
Artisan Electrics
Рет қаралды 9 М.
THIS COULD HAVE KILLED SOMEONE - Electrician Life
33:14
Artisan Electrics
Рет қаралды 111 М.
Don't eat centipede 🪱😂
00:19
Nadir Sailov
Рет қаралды 23 МЛН
¡Puaj! No comas piruleta sucia, usa un gadget 😱 #herramienta
00:30
JOON Spanish
Рет қаралды 22 МЛН
1 класс vs 11 класс (неаккуратность)
01:00
БЕРТ
Рет қаралды 1,9 МЛН
Does Current Flow Through The Neutral Wire?
7:41
eFIXX
Рет қаралды 320 М.
5 Deadly Hidden Electrical Faults
23:56
Artisan Electrics
Рет қаралды 99 М.
ANOTHER DIY BODGE! 🤯 "Why are people like this?!"
28:10
Artisan Electrics
Рет қаралды 92 М.
The WORST Socket Wiring I Have EVER Seen!
32:18
Artisan Electrics
Рет қаралды 119 М.
Electrician Apprenticeship Programs
16:42
Mad Electrician
Рет қаралды 44 М.
A MAJOR ELECTRICAL TRANSFORMATION! - Consumer Unit Upgrade
17:39
Artisan Electrics
Рет қаралды 62 М.
Fault Finding an Electrical Lighting Circuit - Expert Electricians Top Tips
32:39
I'VE BEEN AUDITED! AND I REALLY DISAGREE! - Electrician Life
24:38
Artisan Electrics
Рет қаралды 325 М.
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 639 М.
Xiaomi Note 13 Pro по безумной цене в России
0:43
Простые Технологии
Рет қаралды 1,8 МЛН
IPad Pro fix screen
1:01
Tamar DB (mt)
Рет қаралды 7 МЛН
Трагичная История Девушки 😱🔥
0:58
Смотри Под Чаёк
Рет қаралды 362 М.