How do I install the ICM517 surge protector?

  Рет қаралды 13,295

Taddy Digest

Taddy Digest

Күн бұрын

Пікірлер: 44
@Haihuyen319
@Haihuyen319 Ай бұрын
Very clear. Thanks
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity Жыл бұрын
I installed an Intermatic AG3000 today on a new Fujitsu 15K 25.3 SEER. Thanks Sid Harvey.
@angeloandverny
@angeloandverny 8 ай бұрын
Awesome video tad! Thanks for the info!!!
@TaddyDigest
@TaddyDigest 8 ай бұрын
Any time!
@lovestitanic2004
@lovestitanic2004 2 күн бұрын
Intermatic AG3000 is Compact and easy to Install
@ShajahanKolathur
@ShajahanKolathur 3 ай бұрын
nice i learned more from this video
@TaddyDigest
@TaddyDigest 3 ай бұрын
Glad I could help
@ttaylor6185
@ttaylor6185 11 ай бұрын
Surge protector manufacturers recommend keeping those wires as short and straight as possible. Definitely don't leave them long and curl them up like that.
@yorkehunt9476
@yorkehunt9476 10 ай бұрын
One little trick that I did was put vice grips on each edge of the 3/4 inch knockout and then take out just the 1/2 inch knockout
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 2 ай бұрын
surge protectors for minisplit variable speed equipment
@shanefrank3281
@shanefrank3281 Жыл бұрын
Thanks for addressing 110V installations. Every other video assumes 220V.
@TaddyDigest
@TaddyDigest Жыл бұрын
You are welcome
@MrJeffery9076
@MrJeffery9076 11 ай бұрын
just did my 12000 btu thanks
@TonyRodriguez-ok2ix
@TonyRodriguez-ok2ix 2 ай бұрын
icm517 surge protector
@alexibonnet2634
@alexibonnet2634 Жыл бұрын
Tad I think the gasket will need to be on outside and lock ring tightens to that to prevent water from coming in. I had put similar devices in and gasket goes on outside. Unless this manufacturer specify different
@TaddyDigest
@TaddyDigest Жыл бұрын
No i'm pretty sure you're right gasket does go on the outside I need to check out the instructions again
@rcf8367
@rcf8367 Жыл бұрын
Factory guide shows the seal o-ring on the inside, you’re good to go!
@dporrasxtremeLS3
@dporrasxtremeLS3 6 ай бұрын
Tad, what is your take on removing the device from the enclosure and installing it inside the condenser to minimize damage and exposure to the elements? Great video! Liked 2 thumbs up, and subscribed
@TaddyDigest
@TaddyDigest 6 ай бұрын
If there's enough room inside the condenser I wouldn't see a problem with that.
@mohhamedhossain6789
@mohhamedhossain6789 10 ай бұрын
Good morning, sir This is the one is icm for power load protection...?
@Jaker788
@Jaker788 11 ай бұрын
Aluminum wires connected and touching copper wires? Why do they make the unit with aluminum wires when we know copper on aluminum is not okay and results in corrosion?
@ShuhDonk
@ShuhDonk 10 ай бұрын
How does this stop power/surges from going to the mini split since the power lines from the mini split are still on the lugs from the main breaker?
@MadDog_Barks
@MadDog_Barks 7 ай бұрын
Good question! I see what you see and no one picked up this!!
@danlinden1383
@danlinden1383 Жыл бұрын
Had a well pump go out when lighting hit neighbors house. Can I use this for 220 well pump? Or what if attached to breaker panel and how? Another video?
@TaddyDigest
@TaddyDigest Жыл бұрын
Yes of course you can use this for a well pump
@americanpatriot9942
@americanpatriot9942 Жыл бұрын
Hey brother I love your videos…is there any factory training i can go to for Samsung vrf systems?
@TaddyDigest
@TaddyDigest Жыл бұрын
I'm not sure of any but I will check
@CoolInOlympia
@CoolInOlympia Жыл бұрын
Is there an advantage putting a surge protector at the house electrical board vs at the a/c? What about both?
@AllTattedUp13
@AllTattedUp13 11 ай бұрын
One at your electrical panel will protect every circuit on your house. One at ac will only protect the ac.
@ethanrobinson649
@ethanrobinson649 3 ай бұрын
the shorter the run to the appliance its protecting the better it works.
@bootyhunter4717
@bootyhunter4717 Жыл бұрын
Would you recommend this even tho my home is solar
@TaddyDigest
@TaddyDigest Жыл бұрын
yes absolutely
@albmarku4379
@albmarku4379 Жыл бұрын
Hi Taddy! I appreciate your sharing knowledge with us, but I have a question... Is there a possibility that during the pressure test, dry nitrogen to pass through the service valve? I installed a dual LG inverter 2 months ago but the compressor has gone. I did a pipe line clean to the existing lines with proper liquid cleaner. Now they have sent the outdoor unit to the lab to verify the cause, but I'm sure that the company will blame the installation. Thanks in advance!
@TaddyDigest
@TaddyDigest Жыл бұрын
There is a possibility but it's very unlikely that the nitrogen would pass through that valve Plus your unit comes with a precharge of refrigerant That's interesting two months didn't last very long
@albmarku4379
@albmarku4379 Жыл бұрын
@@TaddyDigest thanks for replying Taddy!
@kevbo75149
@kevbo75149 Ай бұрын
Let me explain this in the lamest terms possible. The monitor is not protecting anything. You still have everything wired to the load side. A true protector would wire to the load side, and the existing wires would wire to the surge protector. The way in your video doesn't cut the power to the equipment during an energy spike, and therefore, it doesn't protect your equipment.
@BRADASSOFFGRIDHOMESTEAD
@BRADASSOFFGRIDHOMESTEAD Жыл бұрын
Couple things. You're much better off getting a whole house surge protector as CLOSE to the meter socket as possible. The surge comes from the grid. You want the point of surge protection the closest you can get it to the "grid". The way you installed it, you ruined anything running in the house except the outdoor unit. Just an FYI, been an electrician since for 20 years. wow I'm getting old.
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity Жыл бұрын
HVAC guys are not usually electricians, so installing one at the unit is better than 99% of the systems out there that have nothing for protection.
@BRADASSOFFGRIDHOMESTEAD
@BRADASSOFFGRIDHOMESTEAD Жыл бұрын
@@USA-GreedyMenOfNoIntegrity Doing something halfass doesn't make it right, it's just "less bad". For the cost to have this installed, it just doesn't make sense to pay to do it wrong.
@lonniekobres5081
@lonniekobres5081 Жыл бұрын
Not all surges come in the mains. Depends on the ultimate wiring layout of the building and where exactly a lightning bolt might be induced into that local wiring grid. Take it from someone who has a 100 ft. lightning rod a short distance from his house. Ideally, each major appliance should be protected, IMO. And then say a prayer and cross your fingers.
@BRADASSOFFGRIDHOMESTEAD
@BRADASSOFFGRIDHOMESTEAD Жыл бұрын
@@lonniekobres5081 .01% don't, you're right... However nobody said anything abut lightning. You need lightning arrestors for that... Like I have installed on my solar system.
@ejn967
@ejn967 11 ай бұрын
What if you have one installed at the panel like you mention, any benefit of a second one at the AC unit itself? @@BRADASSOFFGRIDHOMESTEAD
AC Maintenance - How to Install a Surge Protector For Your Air Conditioner
6:53
Any Hour Services - Electric, Plumbing, Heating & Air
Рет қаралды 40 М.
My Cheetos🍕PIZZA #cooking #shorts
00:43
BANKII
Рет қаралды 27 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 15 МЛН
How to install ICM870 Soft Start? @icmcontrols9960
10:56
Taddy Digest
Рет қаралды 267 М.
ICM517 Single-Phase Surge Protective Device (Install)
4:28
ICM Controls
Рет қаралды 16 М.
How to Install Surge Protector on Air Conditioner Easy
8:01
Word of Advice TV
Рет қаралды 10 М.
WHY CAPACITORS FAIL in Air Conditioners! Watch it Break!
9:45
AC Service Tech LLC
Рет қаралды 1,5 МЛН
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 810 М.