Learn how to diagnose boiler heating issues in Rocket R58 espresso machines. Todd from Whole Latte Love shows you to perform tests to determine why a boiler on an R58 is not heating. Test include: high limit switch, heating element and more.
Do you have a Rocket Espresso R58? If so, be sure and bookmark Whole Latte Love's support wiki for the R58: wiki.wholelattelove.com/Rocke...
It's full of maintenance and troubleshooting info, how to videos, the machine manual and much more!

Пікірлер: 30
@Patrick-oi9lj
@Patrick-oi9lj Жыл бұрын
Serviced my R58 the other day and the steam boiler stopped working after testing and assembling, watched your video and learned about the little circuit breakers, pushed them in and the machine is ready to go. Thank you for that very helpful video!
@Wholelattelovepage
@Wholelattelovepage Жыл бұрын
Hey Patrick, You're welcome - glad it helped! Thanks for takinfg a moment to leave your comment!
@LouisFormica1
@LouisFormica1 6 жыл бұрын
Very nice of you guys to provide such assistance for those a little handy and inclined to do the very testing you show. Makes perfect sense.
@Wholelattelovepage
@Wholelattelovepage 6 жыл бұрын
Hi Louis, Thanks for the comment. We try to provide high quality information!
@waynekingston7772
@waynekingston7772 4 жыл бұрын
Very helpful, thank you!
@Wholelattelovepage
@Wholelattelovepage 4 жыл бұрын
Glad it was helpful! Thanks for taking a moment to leave a comment.
@jordanbouy6186
@jordanbouy6186 2 жыл бұрын
Hi! thank you for the video. One question : my resistance of the steam/water boiler is out 'the one on the right), could you please let me know what is the model i need to buy to replace it? is it A110004667 or C199901551 or A199905013 . I have the Rocket R58. Thank you very much
@nwongs01
@nwongs01 Жыл бұрын
Very informative video as always, my Izzo Alex Duetto stopped heating the brew boiler but the steam boiler is working normal. I followed this video to check SSR, high limit, but still no luck as those checked out fine with the multimeter. Next is for me to check the elements but it locates at the bottom so I will have to remove the bottom panel. My question is that is it ok for me to put the machine on its side to do that?
@Wholelattelovepage
@Wholelattelovepage Жыл бұрын
yes
@jackpast
@jackpast 6 жыл бұрын
As an industrial control tech, I enjoyed the process you presented. Do the prosumer models come with an electrical schematic? I have the ECM Synkronika purchased through you (love it) and it has performed perfectly. Always thinking down the road when the day comes and I turn it on and...nothing happens. Also, if the heating element was bad in either boiler, is that something you could ship out and an owner replace? Thanks guys and keep up the great work!
@Wholelattelovepage
@Wholelattelovepage 6 жыл бұрын
Hi jack, We love the Synchronika too! We do have parts available for ECM machines. If you ever need one it's best to give our tech support a call to make sure you get the right part. They can also verify you actually need a part. Something as simple as a tripped high-limit switch can look like a bad heating element. At this point we do not have a schematic for the Synchronika. But within our support wiki for the machine: wiki.wholelattelove.com/ECM_Synchronika We do have a parts diagram in pdf form: wiki.wholelattelove.com/images/6/6e/SYNCHRONIKA_Parts_Diagram.pdf We are constantly updating the support wiki. I'll get in-touch with ECM and see if they have an electrical schematic available.
@Wholelattelovepage
@Wholelattelovepage 6 жыл бұрын
Hi Jack, Just letting you know the electrical diagram for the Synchronika will be added to the support wiki soon - hopefully today! wiki.wholelattelove.com/ECM_Synchronika
@thomasr9220
@thomasr9220 5 жыл бұрын
Hi there. I need to check the on/off switch on a machine. Which cables do I need to check? The machine sometimes turns on after a couple of minutes and then it works fine. Sometimes it won't turn on.
@Wholelattelovepage
@Wholelattelovepage 5 жыл бұрын
Hi Thomas, Thanks for the question. What make/model machine do you have? Let me know and I can give more specific advice. Do you know how to perform a continuity test using a VOM meter?
@thomasr9220
@thomasr9220 5 жыл бұрын
Hi. I'm sorry, figured that since I wrote on a R58 video you figured that out. HA HA. Anyways, it is a 6 year old R58 and I've performed all tests in the video. However there is too much resistance in the hot water boiler, it read 40ohm. Reading 235-240v out of the circuit relays, but only 4V in, that can't be right? I'm not sure which cables to connect to with my meter to see if there is no continuity in the on/off switch. Really appreciate your answer.
@Wholelattelovepage
@Wholelattelovepage 5 жыл бұрын
No, I'm sorry for not figuring out your machine! To check the switch first unplug the machine from power. With switch in on position check for continuity between terminals carrying the blue and white wires and black and brown. Sounds like you are on 240v power? I cannot speak with authority on voltage or resistance measurements as i'm in US working with 120v so there could be differences. I suggest contacting your local dealer or Rocket Espresso through their support form: rocket-espresso.com/support-form.html If I'm wrong about you being outside the US (which would be weird if you are reading 240v out of the relays) feel free to contact our Whole Latte Love tech support team here: www.wholelattelove.com/contact-us You may find additional troubleshooting information in our support wiki: wiki.wholelattelove.com/Rocket_Espresso_R58_V2/troubleshooting Please be aware info in the wiki is in reference to R58v2 North American machine versions running on 120v power so it may not be applicable to your machine. Hope that helps! Marc
@thomasr9220
@thomasr9220 5 жыл бұрын
Hi Marc, picking up this thread. I have changed the control box and now it turns on (steady green light), but the elements won't heat. The voltage is very low (130v vs 230v) but constant from both static relays. They are not alternating like they should. Any idea? Thanks again, Ill ship you some coffee for the help :)
@redcanon8384
@redcanon8384 2 жыл бұрын
I bought Bezzera Matrix dual boiler mn 3 years ago and now the boiler is not heating up, any advice? Thanks you
@Wholelattelovepage
@Wholelattelovepage 2 жыл бұрын
Hey RC, It could be a number of things. First to check is the high limit thermostat on top of the boiler. If it trips the boiler will not heat and must be reset. Unplug machine and remove the 4 Allen head screws on the top cover. On top of the smaller boiler there are two wires going to the thermostat which has a red button i the middle. Push the little button to reset. Not certain this is your problem but easy to check and fix if it is.
@TD-zc4zi
@TD-zc4zi 2 жыл бұрын
I'm having my steam boiler overheating periodically (causing the safety valve to release at the top). The temp is showing that it's over heating and the relay for the steam boiler goes green even though the temp is already showing high. Is this a control board issue? Thermometer seem to be fine because it's showing that it's too hot. Stumped.
@Wholelattelovepage
@Wholelattelovepage 2 жыл бұрын
Hi TD, If it's energizing the boiler heating element beyond it's set temperature I think there's a good chance you are correct.
@TD-zc4zi
@TD-zc4zi 2 жыл бұрын
@@Wholelattelovepage Do you sell replacement control boards from your Canadian website?
@Orkunmovic
@Orkunmovic 3 жыл бұрын
I see lot issues with r58 on youtube.... wonder if this machine can reach 10 -15 year old still working without issues...
@Wholelattelovepage
@Wholelattelovepage 3 жыл бұрын
Hi o, Not sure what issues you are seeing. I thinks it's like most things - go digging and you'll find people with problems. In many cases it's a user issues. For longevity the single most important thing is feeding a machine with good water which has enough minerals to support flavor but not enough to cause scale. Other maintenance items like regular backflushing is important as well. Over 10-15 years there will be maintenance like group gasket replacement and servicing of the E61 mushroom as well as steam and hot water valves. Hope that helps! Marc
@Orkunmovic
@Orkunmovic 3 жыл бұрын
@@Wholelattelovepage thnx !!
@blairansellfraser
@blairansellfraser 5 жыл бұрын
I have a problem with my 2 year old R58 V2. After recently moving, I switched on the machine whereby the ‘low water reservoir’ light blinked, then became intermittent...the pump continually operated, the whole machine gave off a small electrical charge and after immediately turning off, the machine dumped water from underneath (not sure if it emanates from the service boiler). I have tried to clean the water sensor (using tap water in the reservoir), and have taken off the cover to see if there was any obvious loose wires, or cracks in the boiler...but I am a complete novice. I would really appreciate anyone’s advice, as I am 1,000’s of miles away from an approved dealer and have to troubleshoot myself.
@Wholelattelovepage
@Wholelattelovepage 5 жыл бұрын
Hi BF, Where are you located? If in the US you can contact our tech support by phone/chat/email here: www.wholelattelove.com/pages/contact-us We do service machines. Any chance the machine experienced freezing temperatures during your move? Common issue causing leaks is water freezing in machines when not drained for transport. That can rupture boilers and other components. Marc
@blairansellfraser
@blairansellfraser 5 жыл бұрын
Whole Latte Love . I am far away from a dealer (Asia) and in the tropics (ie. No frost here). Hoping to do some basic troubleshooting and then possibly ordering parts (if needed). Thanks for the reply guys, your videos are fantastic.
@Wholelattelovepage
@Wholelattelovepage 5 жыл бұрын
@@blairansellfraser Thanks for the comment on our videos! Here's a link to our support wiki for the R58 V2 it may be of some help - at least, it has a parts list. If no Rocket dealer in your area I suggest contacting Rocket Espresso in Milan, Italy directly. Here's their contact info including phone and link to online support forum: rocket-espresso.com/contact-us.html Marc
@blairansellfraser
@blairansellfraser 5 жыл бұрын
Whole Latte Love Awesome! Thanks guys!
Rocket Espresso Machines: Draining a Rocket Heat Exchange Boiler
10:10
Whole Latte Love
Рет қаралды 14 М.
ROCKET R58 Coffee machine Disassemble
6:47
世界咖啡品牌
Рет қаралды 8 М.
LOVE LETTER - POPPY PLAYTIME CHAPTER 3 | GH'S ANIMATION
00:15
World’s Deadliest Obstacle Course!
28:25
MrBeast
Рет қаралды 157 МЛН
Looks realistic #tiktok
00:22
Анастасия Тарасова
Рет қаралды 14 МЛН
Rocket R58 Troubleshooting Low Pressure #3750
2:47
Kanen Coffee, LLC.
Рет қаралды 7 М.
Tech Tips: Removing Side Panels on Rocket Espresso Machines
6:14
Seattle Coffee Gear
Рет қаралды 40 М.
Rocket Giotto Steam Wand Valve Repair
14:26
High Desert Man, LLC
Рет қаралды 8 М.
Espresso maker heating problem fixed
10:05
theoverengineer
Рет қаралды 57 М.
Rocket Espresso Appartamento: Internal Tour and Component Identification
20:10
How standing desk legs actually work
16:54
MatthiasWandel
Рет қаралды 209 М.
How a quartz watch works - its heart beats 32,768 times a second
17:35
You Can CHANGE Your Tesla Car’s Color?! #asher #shorts
0:36
Asher Lara
Рет қаралды 12 МЛН
你们会选择哪一辆呢#short #angel #clown
0:20
Super Beauty team
Рет қаралды 11 МЛН
路飞被小孩吓到了#海贼王#路飞
0:41
路飞与唐舞桐
Рет қаралды 7 МЛН