How to dismantle air condition outdoor unit without gauge.

  Рет қаралды 382,663

Chip Channel

Chip Channel

4 жыл бұрын

Step by step ( 10 steps ) pump down operation guide line for air condition outdoor split unit.
#aircondition
#outdoorunit
#pumpdown
#maintenance

Пікірлер: 318
@mikekeating
@mikekeating 3 жыл бұрын
.......Putting new siding up........... You just saved me some $$$$.. 👍thank you👍
@redpost2380
@redpost2380 2 жыл бұрын
This gentleman is to be thanked for the effort of making a video. The technique has many flaws. Use a proper spanner set not an adjustable wrench as the caps can be very tight. Also, with the other hand hold the valve stem with an adjustable wrench when you remove the caps. Pipe stems can bend and even brake, something that this gentleman is ignoring.The air con unit must be placed on COOL setting not heating setting BEFORE you decommission the external unit. Run for at least 5 -10 minutes. If possible place an air heater in front of the internal unit to warm up the evaporator coil. With the hex key break the seal (as the valve will be fully back seated) of the liquid line (HP) valve (1/4" pipe). NOTE at 2:22 in this video when he closes the liquid line, the copper pipe ices up. This tells you that the liguid refrigerant in the pipe is now evaporated. You need to allow all the liquid to evaporate. Run for a few minutes. He runs it for under 2 minutes. may not be enough. You will hear the compressor noise changing as it sucks all the vapour in the compressor circuit. You need to give the liguid refrigerant time to evaporate(in the evaporator that is why the heater will help). Close the gas vapour valve (front seating it) (LP)(5/8" pipe). Ensure both valves are tightly closed. Don't overdo it. Remove the copper pipes and IMMEDIATELY place masking tape to fully cover the valves and the pipes!!! Do not use bubble wrap like this gentleman did. NOTHING must contaminate the pipes or valves. Place the caps back on. Also useful to bring a spray bottle of soapy water to spray on the valve once it is closed to check for leaks. The professionals will use a manifold to decommission the external unit. It allows you to monitor the gas flow and to understand if there is more liquid gas in the evaporator. If the unit is very old it is possible that the valves leak. when you break the seal at the beginning, place soapy water all over the valve and see if it bubbles. If it does. Place the caps back on and call an HVAC pro. Allowing air to enter the condenser when pumping down means that the gas must be removed and disposed of and new gas introduced.
@chipchannel174
@chipchannel174 2 жыл бұрын
Thanks sir for the great explanation.
@kaveritare..
@kaveritare.. 2 жыл бұрын
Is it necessary to release the gas for shifting the outlet
@IsmadiAhmad
@IsmadiAhmad 2 жыл бұрын
@@chipchannel174 i have no gas in the unit. Can i just plug everything off?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@IsmadiAhmad close the valve before dismantle. The best way is to get the gauge and measure before dismantle.
@michaelkrakowski2804
@michaelkrakowski2804 2 жыл бұрын
Hi Excellent comment! Does this procedure apply for Inverter AC as well thanks BTW, I think pipe size is 3/8 not 5/8. (line 10)
@DiscoFang
@DiscoFang 2 жыл бұрын
Alternate title: "Man takes 5 mins to realize a Hex wrench works on both ends"
@RatWorks001
@RatWorks001 2 жыл бұрын
Oh come on, it was only 4 minutes. 3:58 seconds in fact... OMG, it was such a relief when it happened. Thanks for the video Chip, it was very interesting.
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
Yes I was thinking "where did they get this turkey?" lol
@I_am_007
@I_am_007 2 жыл бұрын
Allen key
@chadrayl9648
@chadrayl9648 Жыл бұрын
Horrible
@ANTONYBROWN-jl8fx
@ANTONYBROWN-jl8fx 4 ай бұрын
​@@bobboscarato1313p00
@ivispimienta9243
@ivispimienta9243 2 жыл бұрын
Congratulations sir. Very useful this video. Thanks a lot for taking your time to share this valuable information. Thanks
@bobboscarato1313
@bobboscarato1313 2 жыл бұрын
It was a terrible video; very unprofessional..!
@SenthilKumar-gz1ll
@SenthilKumar-gz1ll 2 жыл бұрын
anna amazing explaination step by step instructions very thanking sir
@chipchannel174
@chipchannel174 2 жыл бұрын
Welcome
@aneshchopra
@aneshchopra 2 жыл бұрын
Tnx bhai aapki help se aaj maine apne 1000 ₹ bacha liye without mechanic 😀😀😀......tnx
@johnjosephpuntual1264
@johnjosephpuntual1264 3 ай бұрын
thankyou, very simple, and very clear to understand
@garvinjohnson437
@garvinjohnson437 3 жыл бұрын
I see in the Bahamas where I live the close the big line first then turn the ac on let it run for about a minute or 2 then turn the unit off then close the small line
@punampandit1785
@punampandit1785 2 жыл бұрын
Thanks for helpful video Love from Nepal
@VernonGovender-db4tg
@VernonGovender-db4tg 2 ай бұрын
Thank u I learnt something from you I did try to remove the unit in a different way and did not work now will use ur video ...
@watchtime9072
@watchtime9072 Жыл бұрын
Brilliant! Thanks for posting.
@LS-ki9nl
@LS-ki9nl 2 жыл бұрын
Just what I was looking for. Thanks.
@chipchannel174
@chipchannel174 2 жыл бұрын
You are welcome…
@kylekey9619
@kylekey9619 2 жыл бұрын
Thanks for the video.
@chipchannel174
@chipchannel174 2 жыл бұрын
Welcome..
@naserdaatomukherchikitshak9363
@naserdaatomukherchikitshak9363 3 жыл бұрын
It was very useful video.
@chipchannel174
@chipchannel174 2 жыл бұрын
Thanks
@jordanoliveros3510
@jordanoliveros3510 2 жыл бұрын
Good job Sir kahit walang audio pero malinao
@chipchannel174
@chipchannel174 2 жыл бұрын
Thank you..
@thebman8787
@thebman8787 Жыл бұрын
Thank you!
@dtb7872
@dtb7872 Жыл бұрын
Upon reconnect, did you pump down the system yourself and recharge?
@ddaanniijjeell
@ddaanniijjeell 2 жыл бұрын
Tnx for this 👍💪
@delberttips9177
@delberttips9177 2 жыл бұрын
Thank you bro.
@addiszemen1637
@addiszemen1637 3 жыл бұрын
thank you!
@chipchannel174
@chipchannel174 3 жыл бұрын
Welcome
@diysolaradventures7894
@diysolaradventures7894 Жыл бұрын
Mine's is in heating mode can I pump it down with the heat running ain't that still sending Freon through the lines
@stvn2918
@stvn2918 3 жыл бұрын
Very useful 👍
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks a lot
@ariansinanaj8668
@ariansinanaj8668 Жыл бұрын
You have done good job, thank you very much for detailed video.
@pajayalath9967
@pajayalath9967 2 жыл бұрын
Thank good video .
@noodles806
@noodles806 3 жыл бұрын
Thanks for this! What did you do with the loose power cable after?
@chipchannel174
@chipchannel174 3 жыл бұрын
No longer used. The power cable is from the indoor units.
@noodles806
@noodles806 3 жыл бұрын
@@chipchannel174 I should have been more specific. What did you do to secure/stow it safely since it wasn’t being used after?
@chipchannel174
@chipchannel174 3 жыл бұрын
@@noodles806 power cable units usually connected and follow through the cooper pipe with insulation from indoor to outdoor units. If no longer used it then you can just pull or remove those pipe and cables.
@michaelkrakowski2804
@michaelkrakowski2804 2 жыл бұрын
Hi thanks for the video Does this procedure apply for Inverter AC as well
@chipchannel174
@chipchannel174 2 жыл бұрын
Pump down process required the compressor to run. Should be apply for both system as long as compressor running. Inverter is just providing variable power and speed control to the compressor and fan. This is what Im understanding about the process and system. You may refer to others expert about the AC if you have any concerns.
@quancydang8252
@quancydang8252 3 жыл бұрын
thank you! this was helpful!
@chipchannel174
@chipchannel174 3 жыл бұрын
You are welcome..
@sucider5406
@sucider5406 2 жыл бұрын
Very useful 🙏
@chipchannel174
@chipchannel174 2 жыл бұрын
Thank you..
@akkioshin715
@akkioshin715 13 күн бұрын
Great video i wish i watched this one before losing all my gas thanks to the other video i watched where he says to wait 30seconds ..
@letsoaje
@letsoaje Күн бұрын
Me too 😢
@mdabdulmoiz
@mdabdulmoiz 3 жыл бұрын
i just want to change the direction of my outdoor unit can I do it myself, now you have shown how to unplug but how do I reconnect this back?
@chipchannel174
@chipchannel174 3 жыл бұрын
Usually for installation required vacuum pump to vacuum the air inside the cooper pipe before release the gas. This video just to show how to disconnect the outdoor unit. You may search for others video for installation guideline. Not much different between relocation and install the new AC.
@dgb5820
@dgb5820 Жыл бұрын
Great video
@chipchannel174
@chipchannel174 Жыл бұрын
Thanks!
@user-sn7wd6bx6t
@user-sn7wd6bx6t 3 жыл бұрын
Good job
@chipchannel174
@chipchannel174 3 жыл бұрын
微微 thank you
@krisztianbalazs7839
@krisztianbalazs7839 2 ай бұрын
It is a good video and a huge thank you for it but you can use the long side of the alan key too. :)
@shahriljaszle4606
@shahriljaszle4606 4 жыл бұрын
Tahniah Bro
@chipchannel174
@chipchannel174 4 жыл бұрын
Untuk rujukan diri sendiri di masa hadapan sama tuan. :)
@Dom75GR
@Dom75GR 2 жыл бұрын
Video helped a lot. Just have a question. Is the proccess the same to re install it ?? Or it needs to by done by a pro with special tools ?
@chipchannel174
@chipchannel174 2 жыл бұрын
Installation no need to turn on the compressor as pump down process. Hook up, release the gas and turn on the AC. Probably need to use gauge to check either has enough gas or not. For better results, please consults your local expert.
@jasonkolb1284
@jasonkolb1284 2 жыл бұрын
@@chipchannel174 don't you need to evacuate the evaporator and line set with a vacuum pump?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@jasonkolb1284 Air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system basically in cooper pipe. Pump down process to move and keep the gas to compressor. Similar to when you buy new AC, the gas already have inside.
@praveenmannam3001
@praveenmannam3001 3 жыл бұрын
Its good if you do its continued part for indoor until outdoor & indoor units kept on floor.
@chipchannel174
@chipchannel174 3 жыл бұрын
Praveen Mannam yes I will if I have job to dismantle indoor unit. I will update in my channel. Thank you.
@ryel073
@ryel073 2 жыл бұрын
May i ask you sir i have plan to transfer my AC to other room with by my self. Can i just reconnect the two pipe and cup then reopen that 2 supply? Or can you tell me what to do for Reconnecting? !
@chipchannel174
@chipchannel174 2 жыл бұрын
Basically when you want to reinstall or install the AC, you need vacuum and gauge to clear the air inside the cooper pipe from outdoor to indoor. The reason is to ensure your gas is purely and not mixing with air trap inside the cooper pipe to maximise the cooling operation. But you still can do that.
@RS9World
@RS9World 3 жыл бұрын
Can you do this in heating mode? Will the steps be the same?
@chipchannel174
@chipchannel174 3 жыл бұрын
As I know, during pump down need to run or activate the compressor and usually set to lowest temperature.
@boutserk5
@boutserk5 9 ай бұрын
I did it exactly like you said and everything is fine. Thanks
@chipchannel174
@chipchannel174 9 ай бұрын
Welcome
@atuldaware3679
@atuldaware3679 3 жыл бұрын
Thank u..
@chipchannel174
@chipchannel174 3 жыл бұрын
atul daware welcome
@kazielbonn
@kazielbonn Жыл бұрын
Waited for ages for the person to switch to the alan wrench's long end.
@barrygaynor1025
@barrygaynor1025 Жыл бұрын
Thank you.
@chipchannel174
@chipchannel174 Жыл бұрын
You're welcome!
@unnikrishna4133
@unnikrishna4133 3 жыл бұрын
Thank you is a small word
@chipchannel174
@chipchannel174 3 жыл бұрын
Please share this video if you think this information helpful. Thanks
@ashishsankrit1290
@ashishsankrit1290 3 жыл бұрын
After removing the outdoor unit how to remove the pipe safely from indoor unit is their any connector or any joint ??
@chipchannel174
@chipchannel174 3 жыл бұрын
Yes. There is another joint at indoor unit need to remove. Disconnect the incoming power cable as well. After that you can lift up the indoor unit out from the bracket. Then remove the bracket at wall. That it.
@hamzakhattak5365
@hamzakhattak5365 Жыл бұрын
A question: you tighten up the gas valve first, after the air is changed from hot to normal you again tighten up the valve, is this process can be done 1 time or it should be done in 2 steps?
@chipchannel174
@chipchannel174 Жыл бұрын
2 steps since the process is to pull all the gas and keep into outdoor unit. If one time you will lose the gas once you dismantle the cooper pipe.
@stvn2918
@stvn2918 3 жыл бұрын
Is it necessary to switch on before unmantle?
@chipchannel174
@chipchannel174 3 жыл бұрын
Yes sir. Pump down process need to run the compressor in order to flow the gas.
@sonchan3621
@sonchan3621 11 ай бұрын
how to put it back again?
@Marsell88
@Marsell88 2 жыл бұрын
Thanks a bunch dude! God bless... Mofos asking for 30-50 euros to dismantle my AC.
@MrBENTPIN
@MrBENTPIN Жыл бұрын
Costs.650 to instal one in Australia
@zaidhamid7269
@zaidhamid7269 3 жыл бұрын
Love the black ops 2 intro
@skkadir655
@skkadir655 3 жыл бұрын
Thanks brother
@chipchannel174
@chipchannel174 3 жыл бұрын
Welcome
@chipchannel174
@chipchannel174 3 жыл бұрын
Please share this video if you think this helpful. Im not an expert but I just share based on my experience and for my reference as well.
@Swenser
@Swenser 3 жыл бұрын
I closed liquid line and after a few minutes decided to not pump down but re open liquid line. I expected the system to revert to normal operation, but the compressor cuts of after a few seconds, like there is a problem sensed. I left over 24 hrs to rebalance gas but the compressor still stops after a few seconds and cycles about every minute. What could be the problem after this closing of liquid valve temporarily for a few minutes? Why does the compressor stay on. It was fine before attempted cut short pump down.
@chipchannel174
@chipchannel174 3 жыл бұрын
How long you turn on the AC after re open the valve? What is the temp setting at your AC controller? You can try to set at min temp and run the AC. Usually the compressor will turn off if the indoor sensor detect the temperature tally with the controller setting. Hope this help.
@Swenser
@Swenser 3 жыл бұрын
@@chipchannel174 temp was set at minimum. After 24 hrs rest just in case of pressure imbalance or frosting I tried ac on for 15 minutes but always cycled on for a few seconds off about 1 min. Pumping compressor down for a few minutes maybe damaged compressor in my case??
@chipchannel174
@chipchannel174 3 жыл бұрын
@@Swenser please check your liquid line valve again. Could be the valve not fully open or maybe stuck. How’s the room temperature? It’s cool?
@Swenser
@Swenser 3 жыл бұрын
@@chipchannel174 warm day in melbourne. gas definitely at schraeder valve. A quick depression of valve confirmed that. No gauge to check pressures. Evap not showing any signs of icing at all.
@chipchannel174
@chipchannel174 3 жыл бұрын
@@Swenser Im facing 1 issue before this outdoor unit not running or intermittence due to not enough gas..need to top up the gas according to outdoor specs then the AC back to normal. You need have gauge to confirm on this.
@GregoryJHill-ub6ow
@GregoryJHill-ub6ow 2 жыл бұрын
My copper lines were soldered directly to AC unit. Can I cut these lines?
@chipchannel174
@chipchannel174 2 жыл бұрын
You can cut after pump down and turn off the main supply.
@hansmaier3689
@hansmaier3689 5 ай бұрын
In case you are in heating mode close gas line and than liquid site?
@chipchannel174
@chipchannel174 5 ай бұрын
This process I just follow the instruction from the service manual for this model. You may refer to your AC model service manual for better view or clarifications.
@Gganp1
@Gganp1 Жыл бұрын
very good job, please add audio. Rated number 1. Best ever. Thank you you my $500 I would like to send you a gift certificate.
@chipchannel174
@chipchannel174 Жыл бұрын
Wow, thanks!
@vishnukannan236
@vishnukannan236 3 жыл бұрын
I closed liquid line first and after 4 Minute i closed gas stop valve any problem pls tell
@chipchannel174
@chipchannel174 3 жыл бұрын
Depend on AC HP..if 1 HP with less than 10 feet cooper pipe should be ok.
@joshuacummins2076
@joshuacummins2076 3 жыл бұрын
Do you just do the reverse order to hook it back up. Great video btw!
@chipchannel174
@chipchannel174 3 жыл бұрын
To hook it up with proper way is just need another step which is vacuum the cooper pipe before release the gas. You need to have vacuum and gauge to do this process.
@chipchannel174
@chipchannel174 Жыл бұрын
@Khanh Phan to install new AC I suggest to follow the actual procedure which is you need gauge and vacuum pump. This video just for special case to disconnect your AC without those equipment. Please refer to AC expert on your area.
@senthilkumars9288
@senthilkumars9288 2 жыл бұрын
Super
@johnpaulcalubay6120
@johnpaulcalubay6120 3 жыл бұрын
Hello is this need to set to highcool to close all the valve to pump down?
@chipchannel174
@chipchannel174 3 жыл бұрын
As long as outdoor unit running.
@viktorponkratov3213
@viktorponkratov3213 3 жыл бұрын
👍👍👍
@keerthirajendran5952
@keerthirajendran5952 3 жыл бұрын
What is the size of hexagon wrench??
@chipchannel174
@chipchannel174 3 жыл бұрын
Sorry about that. I forgot the size for the Allen keys. I have a set of combinations size so I just try which one is fix. If I have the opportunity to confirm on this I will share in my next videos.
@ralistaduncan8092
@ralistaduncan8092 Жыл бұрын
Please I need help I did the process successfully, I had little gas come out from the pipe from the indoor unit but now I need to put it back, the gas pipe get frozen white and it won't get cold inside is there something wrong with my unit ?
@chipchannel174
@chipchannel174 Жыл бұрын
Probably not enough gas i think.
@jaewalker1527
@jaewalker1527 3 жыл бұрын
Can i do it by turning off the the ac, I’m worried of being electricuted
@chipchannel174
@chipchannel174 3 жыл бұрын
To pump down the gas and keep inside the compressor, you need to follow this steps with running condition. Once done then you can switch off the supply and dismantle the cooper pipe.
@jaewalker1527
@jaewalker1527 3 жыл бұрын
@@chipchannel174 thanks i did the same procedure...
@akadbakadbombayaboo
@akadbakadbombayaboo 3 жыл бұрын
How do you know which valve is gas valve and which is liquid valve. The size of both the valve on brivis honbr50 outside unit is nearly same Thanks
@chipchannel174
@chipchannel174 3 жыл бұрын
Please refer product manual for confirmation.
@chipchannel174
@chipchannel174 3 жыл бұрын
The cooper pipe size should be different.
@adamjones9600
@adamjones9600 Жыл бұрын
Well this work on a vehicle? I would like to remove the ac unit from the vehicle. AC works but car can’t move.
@chipchannel174
@chipchannel174 Жыл бұрын
Basically should be the same process. Could be better you refer to service manual.
@xylenesavannah5076
@xylenesavannah5076 Жыл бұрын
what will happen if I just closed all valve without powering the AC for some minutes before do that
@chipchannel174
@chipchannel174 Жыл бұрын
You will lost the gas inside the pipe and indoor unit. This is not a good practice since you will release the gas to the environment. Also it will cost you during installation because need to top up the gas.
@hlalthanpuia1494
@hlalthanpuia1494 Жыл бұрын
Good video Sir. Is it required to switch on the ac power before dismantling?
@chipchannel174
@chipchannel174 Жыл бұрын
After pump down completed and all valve are close, you need to turn off the power before dismantle the power cable.
@hlalthanpuia1494
@hlalthanpuia1494 Жыл бұрын
@@chipchannel174 Thank you sir🙏🙏
@flattblackjakus
@flattblackjakus 3 жыл бұрын
I have a 7000btu unit with only a 10ft pair of lines hooked up to my school bus conversion. What’s the length of time I should wait till closing the second valve?
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks for your comment. The proper way is using the gauge or you can refer to installation guide ( pump down ) according to your AC model and brand. Some manual said the duration is 5 minutes or more referring to your lines length. You can feel the hot air blowing turn to normal temperature and you can close the valve. For my case line length also about 10ft. Anyway, Im not an expert but I’m sharing this video based on my experiences.
@Tamiltech360senthil
@Tamiltech360senthil 3 жыл бұрын
Nice bro
@chipchannel174
@chipchannel174 3 жыл бұрын
Thanks
@elias.anjel8170
@elias.anjel8170 Ай бұрын
Hi it have turns on on cooling yeah? I followed your steps but fan still not working, can this steps work if the fan not turning? Thanks
@elias.anjel8170
@elias.anjel8170 Ай бұрын
Or have turned on heating??
@chipchannel174
@chipchannel174 Ай бұрын
Outdoor compressor need to run for this process. Usually outdoor fan will running if outdoor unit turn on.
@fredericsheridan1436
@fredericsheridan1436 27 күн бұрын
When you reinstall the unit is it the same procedure?
@chipchannel174
@chipchannel174 27 күн бұрын
For reinstall you need vacuum to clear the air trap inside the cooper for better results. Procedure should be reverse from dismantle process but you need to check all the connection are good to ensure no leakage.
@curtissharris8914
@curtissharris8914 Жыл бұрын
what's running and what does ....3 after 5 to 10 minutes mean?
@chipchannel174
@chipchannel174 Жыл бұрын
To let the compressor running and stop the gas flow from outdoor unit to indoor unit.
@normanlatu3498
@normanlatu3498 2 жыл бұрын
What about if there gas still in the lines?
@chipchannel174
@chipchannel174 2 жыл бұрын
Pump down process actually to pull all the gas inside the pipe and keep inside the the compressor. So, please complete the process to avoid release the gas to environment which will cause the pollution. Second things is you no need to top up the gas or just minimal when you reinstall the AC to others location and will save your money as well.
@unrulian
@unrulian 3 жыл бұрын
my problem is board is broken and I can't turn it on but need to remove unit. can you do this without turning unit on?
@chipchannel174
@chipchannel174 3 жыл бұрын
Just close the valve and slowly disconnect the cooper pipe. Please be careful cause it high pressure.
@matttzzz2
@matttzzz2 3 жыл бұрын
@@chipchannel174 STOP. NO. You're NOT allowed to just release the gas into the atmosphere. Stop repeating this nonsense to everyone! You have to capture the gas using a recovery unit into an emptg gas bottle that will be dosposed of.
@fartsmccracken1445
@fartsmccracken1445 2 жыл бұрын
@@matttzzz2 Screw the environment. I got work to do. Biden’s gonna kill us all anyway.
@avetsuper6272
@avetsuper6272 Жыл бұрын
what about freon from pies ,its gone to air ?
@chipchannel174
@chipchannel174 Жыл бұрын
That’s the reason of pump down process before dismantle the unit.
@xauyala
@xauyala 7 күн бұрын
Thanks
@chipchannel174
@chipchannel174 7 күн бұрын
@@xauyala welcome
@franciskimocop6018
@franciskimocop6018 3 жыл бұрын
What if there is no power ? How can i remove the outdoor unit ?
@chipchannel174
@chipchannel174 3 жыл бұрын
You must have pressure gauge and empty gas bottle to transfer the gas before dismantle the cooper pipe. Do not release the gas to the atmosphere. Please consult your local competent person for help if required.
@bsiah9073
@bsiah9073 3 ай бұрын
hey man no need to discharge the gas or liquid before you close the valve or remove the copper pipe? huh
@ralistaduncan8092
@ralistaduncan8092 Жыл бұрын
Thank you very much
@chipchannel174
@chipchannel174 Жыл бұрын
You are welcome…
@ralistaduncan8092
@ralistaduncan8092 Жыл бұрын
Please what's the size of the hexagon key ?
@chipchannel174
@chipchannel174 Жыл бұрын
@@ralistaduncan8092 sorry, I forgot the hex size because I have a set of it. It may varies depend on model.
@ralistaduncan8092
@ralistaduncan8092 Жыл бұрын
@@chipchannel174 I had a gas come out the small pipe though the hexagon nut was tight, I hope that's isn't a problem , I'd used it a night before dismantling
@ralistaduncan8092
@ralistaduncan8092 Жыл бұрын
@@chipchannel174 please I have put it back on and won't get cold inside the gas pipe is frozen white is there something wrong with my unit
@arseniong7940
@arseniong7940 2 жыл бұрын
When re installing, then is it same procedure? Ty
@chipchannel174
@chipchannel174 2 жыл бұрын
Can you translate in english please. Tq.
@chipchannel174
@chipchannel174 2 жыл бұрын
For installation you need to have vacuum and guage before release the gas.
@cramemichael2023
@cramemichael2023 2 жыл бұрын
How did you remove the refrigerant. Where it go.
@chipchannel174
@chipchannel174 2 жыл бұрын
Pump down process is to keep the gas into the compressor.
@imStrato
@imStrato Жыл бұрын
@@chipchannel174 Not in the compressor itself, it does not have capacity to hold average amount of refrigerant. Most of the refrigerant is stored in the condenser tubes.
@jesterrio6251
@jesterrio6251 2 жыл бұрын
inverter or non inverter the same procedure?
@chipchannel174
@chipchannel174 2 жыл бұрын
Procedure should be the same. The different between this AC type just to control the power. For the duration you may refer to service manual or expert on your area. I just show the step by step process only. Hope this help.
@mike82y
@mike82y 2 жыл бұрын
What will happened if u just let u leak out?
@chipchannel174
@chipchannel174 2 жыл бұрын
First, you will contribute to air pollution. Second, you need to refill the gas during installation and cost you more $.
@TheWuzyy
@TheWuzyy 2 ай бұрын
For god sake, please use the long end of the hex wrench!
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
Oh, for goodness sake, use the long end of the hex wrench until you have to tighten it. Jeez. Like watching paint dry!
@chipchannel174
@chipchannel174 3 жыл бұрын
The reason why I’m slowly turn the hex wrench because of to ensure all the gas flow into the compressor. It’s not just about to close the valve only.
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
Yeah, but you finally worked it out towards the end of closing the second valve ;) Anyway, thank you for the video. Most helpful and appreciated. :)
@flattblackjakus
@flattblackjakus 3 жыл бұрын
I found it quite soothing and satisfying lol
@isumiterracetv506
@isumiterracetv506 3 жыл бұрын
hahaha... Good on ya, fella. :)
@JosuRibeiro
@JosuRibeiro 2 жыл бұрын
@@isumiterracetv506 I was frustrated too... do we need to watch. Every. Single. Turn. Of. That. Wrench?! hahaha but great video tho
@OfficialHowItRuns1.0
@OfficialHowItRuns1.0 Ай бұрын
Sir how long to wait for gas valve after tightening the liquid valve?
@chipchannel174
@chipchannel174 Ай бұрын
Depend on AC HP. You can refer service manual for your type of AC.
@hamsterdogcat
@hamsterdogcat 6 ай бұрын
Thank you sir! But how to make it run again?
@chipchannel174
@chipchannel174 6 ай бұрын
You may refer to others video for installations. .
@maxgrind438
@maxgrind438 2 жыл бұрын
What if the compressor is damaged.?
@chipchannel174
@chipchannel174 2 жыл бұрын
Basically, you need gauge and release the gas into empty container in order to dismantle the outdoor unit. Do not release the gas direct to environment. This video just show the pump down process before dismantle the outdoor units that still function or working well.
@parisparknarzo
@parisparknarzo 3 ай бұрын
boss kung matagal nang tengga ang generator, kailangan pa ba e power on para maalis ang mga tubo?
@chipchannel174
@chipchannel174 3 ай бұрын
Translate to english please.
@andrewdefour7980
@andrewdefour7980 3 жыл бұрын
Can you reconnect the same way you disconnect without using vacuum and gauge if the unit was down for less than a month?
@chipchannel174
@chipchannel174 3 жыл бұрын
Once you remove the cooper pipe, better to use vacuum before connect it back.
@nhojjohn4054
@nhojjohn4054 2 жыл бұрын
It's safe if the liquid is leaking? Thnx the AC is not operating
@chipchannel174
@chipchannel174 2 жыл бұрын
Do you mean leaking caused the AC not working or leaking during dismantle?
@nhojjohn4054
@nhojjohn4054 2 жыл бұрын
During dsmqmtle
@chipchannel174
@chipchannel174 2 жыл бұрын
@@nhojjohn4054 if compressor in running condition means during pump down process should be less possibility or in min qty for leaking but of compressor not running there is another process to release the gas. Main point is do not release the gas to the environment which will contribute to the air pollution. You can search about the process and procedure of release the gas without compressor in running condition.
@johnrogers1423
@johnrogers1423 2 жыл бұрын
Using the shifting spanner the other way around is less likely to damage the spanner.
@carlyncorley9187
@carlyncorley9187 2 жыл бұрын
bang apa mksud pump down sblm tutup valve tu and knpa nak psg ac?
@chipchannel174
@chipchannel174 2 жыл бұрын
Nak sedut dan simpan gas masuk ke dlm compressor sebelum buka paip..kena turn on untuk bg compressor jalan.
@narpavi2651
@narpavi2651 3 жыл бұрын
After AC installation first open what pipe
@chipchannel174
@chipchannel174 3 жыл бұрын
Open the liquid valve first and after that open the gas valve.
@PedroAntonio-jw7rr
@PedroAntonio-jw7rr 2 жыл бұрын
@@chipchannel174 is the liquid one the bigger line and the gas the small one
@chipchannel174
@chipchannel174 2 жыл бұрын
@@PedroAntonio-jw7rr already mentioned in the process..gas line is the bigger pipe..
@ashishsankrit1290
@ashishsankrit1290 3 жыл бұрын
I did it but when I remove pipe still gas is leaking
@chipchannel174
@chipchannel174 3 жыл бұрын
Depend on outdoor unit size or hp..more than 1hp and longer cooper pipe you need to take more time during pump down. Anyway, you still can top up the gas if you want to install at other place.
@alanheng944
@alanheng944 2 жыл бұрын
Bang, kalo nk check outdoor unit masih berfungsi x mcm mana nk check caranya?sbb sy baru dapat sebiji outdoor dari kawan igt nk pasang kt rumah tapi x pasti masih berfungsi x..tq
@chipchannel174
@chipchannel174 2 жыл бұрын
Boleh direct sambung power cable untuk pastikan compressor berfungsi. Jangan lama sebab bila compressor jalan dlm keadaan valve tutup akan jadi tekanan tinggi.
@alanheng944
@alanheng944 2 жыл бұрын
@@chipchannel174 tq bang sbb sudi berkongsi ilmu..
@alanheng944
@alanheng944 2 жыл бұрын
@@chipchannel174 lepas direct sambung kipas berfungsi maksud nya masih elok ke? atau ada petunjuk lain?
@chipchannel174
@chipchannel174 2 жыл бұрын
@@alanheng944 kipas berfungsi kira motor kipas pon masih ok lah..kalau compressor dia ada bunyi dengung sket .
@russelvicencio9194
@russelvicencio9194 3 жыл бұрын
Bossing pag b ptay aircon ng matagal wala nba gas sa piping
@chipchannel174
@chipchannel174 3 жыл бұрын
Sorry I cant understand you..can you translate to english please..
@snowythehusky5912
@snowythehusky5912 2 жыл бұрын
Bro kalau dalam kondisi ada freon seperti ini, apakah aman dibawa pakai mobil untuk dipindahkan? Thank you
@chipchannel174
@chipchannel174 2 жыл бұрын
Tiada masalah..tutup semua valve rapat elok. Sama seperti kita beli AC baru, dlm dia sudah ada freon dah. Untuk pemasangan semula kemungkinan hanya perlu tambah freon sedikit sahaja. Jimat wang.
@azaanusman8039
@azaanusman8039 3 жыл бұрын
Brother mene ghalti se AC on kiye bagair outdoor seprate krdiya is se jo condenser me gas thi wo waist ho gai brother kitne percent gas meri zaya ho gai ap bta sakte hai
@chipchannel174
@chipchannel174 3 жыл бұрын
Im sorry brother...Im not understand your question. Can you translate it to english?
@chipchannel174
@chipchannel174 3 жыл бұрын
@@RideAdventureMoto do not release the gas to the atmosphere as this will impact the environment...need to have gauge and transfer to empty gas bottle or please consult your local competent person for help.
@AllahMyHeart
@AllahMyHeart 2 жыл бұрын
What is size of hexagonal wrench?
@chipchannel174
@chipchannel174 2 жыл бұрын
Im sorry..i can’t remember the hex size..you may refer to your AC service manual.
@AllahMyHeart
@AllahMyHeart 2 жыл бұрын
@@chipchannel174 no problem I asked the shop keeper he told me the size suitable for my ac
@chipchannel174
@chipchannel174 2 жыл бұрын
@@AllahMyHeart May Allah ease everything …amiinn..
@Vii_Tannu
@Vii_Tannu 2 жыл бұрын
How to re-install it
@chipchannel174
@chipchannel174 2 жыл бұрын
To re-install basically just reverse this process but before you release the gas, you must have the vacuum and gauge to clear all the air trap inside the cooper pipe from outdoor to indoor. This is the correct way to optimise your AC operation.
How To Make an R410A Flare for a Mini Split AC Unit Installation
12:11
Benjamin Sahlstrom
Рет қаралды 2 МЛН
Haier Ductless Mini Split Refrigerant Pump Down
8:52
Emerson Swan, Inc.
Рет қаралды 63 М.
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 12 МЛН
MISS CIRCLE STUDENTS BULLY ME!
00:12
Andreas Eskander
Рет қаралды 16 МЛН
Alex hid in the closet #shorts
00:14
Mihdens
Рет қаралды 13 МЛН
Зачем он туда залез?
00:25
Vlad Samokatchik
Рет қаралды 3,3 МЛН
Deep cleaning AC in Guam by professional HVAC technicians
3:02
AEL&L Air Conditioning Services
Рет қаралды 2 МЛН
MOVING AIR CONDITIONER UNIT: Watch This Before You Move Your Outside AC Unit
3:26
How does your AIR CONDITIONER work?
7:43
Lesics
Рет қаралды 8 МЛН
Paano Magkalas ng Split Type Aircon?
8:08
MaThalent
Рет қаралды 15 М.
How to backup and uninstall a Mini Split to move it and Life Update.
10:48
How to Clean Your Mini Split AC Condenser - Make it Cold Again
7:06
Silver Cymbal
Рет қаралды 601 М.
Sigma girl and soap bubbles by Secret Vlog
00:37
Secret Vlog
Рет қаралды 12 МЛН