Step by step ( 10 steps ) pump down operation guide line for air condition outdoor split unit. #aircondition #outdoorunit #pumpdown #maintenance
Пікірлер: 318
@mikekeating3 жыл бұрын
.......Putting new siding up........... You just saved me some $$$$.. 👍thank you👍
@redpost23802 жыл бұрын
This gentleman is to be thanked for the effort of making a video. The technique has many flaws. Use a proper spanner set not an adjustable wrench as the caps can be very tight. Also, with the other hand hold the valve stem with an adjustable wrench when you remove the caps. Pipe stems can bend and even brake, something that this gentleman is ignoring.The air con unit must be placed on COOL setting not heating setting BEFORE you decommission the external unit. Run for at least 5 -10 minutes. If possible place an air heater in front of the internal unit to warm up the evaporator coil. With the hex key break the seal (as the valve will be fully back seated) of the liquid line (HP) valve (1/4" pipe). NOTE at 2:22 in this video when he closes the liquid line, the copper pipe ices up. This tells you that the liguid refrigerant in the pipe is now evaporated. You need to allow all the liquid to evaporate. Run for a few minutes. He runs it for under 2 minutes. may not be enough. You will hear the compressor noise changing as it sucks all the vapour in the compressor circuit. You need to give the liguid refrigerant time to evaporate(in the evaporator that is why the heater will help). Close the gas vapour valve (front seating it) (LP)(5/8" pipe). Ensure both valves are tightly closed. Don't overdo it. Remove the copper pipes and IMMEDIATELY place masking tape to fully cover the valves and the pipes!!! Do not use bubble wrap like this gentleman did. NOTHING must contaminate the pipes or valves. Place the caps back on. Also useful to bring a spray bottle of soapy water to spray on the valve once it is closed to check for leaks. The professionals will use a manifold to decommission the external unit. It allows you to monitor the gas flow and to understand if there is more liquid gas in the evaporator. If the unit is very old it is possible that the valves leak. when you break the seal at the beginning, place soapy water all over the valve and see if it bubbles. If it does. Place the caps back on and call an HVAC pro. Allowing air to enter the condenser when pumping down means that the gas must be removed and disposed of and new gas introduced.
@chipchannel1742 жыл бұрын
Thanks sir for the great explanation.
@kaveritare..2 жыл бұрын
Is it necessary to release the gas for shifting the outlet
@IsmadiAhmad2 жыл бұрын
@@chipchannel174 i have no gas in the unit. Can i just plug everything off?
@chipchannel1742 жыл бұрын
@@IsmadiAhmad close the valve before dismantle. The best way is to get the gauge and measure before dismantle.
@michaelkrakowski28042 жыл бұрын
Hi Excellent comment! Does this procedure apply for Inverter AC as well thanks BTW, I think pipe size is 3/8 not 5/8. (line 10)
@DiscoFang2 жыл бұрын
Alternate title: "Man takes 5 mins to realize a Hex wrench works on both ends"
@RatWorks0012 жыл бұрын
Oh come on, it was only 4 minutes. 3:58 seconds in fact... OMG, it was such a relief when it happened. Thanks for the video Chip, it was very interesting.
@bobboscarato13132 жыл бұрын
Yes I was thinking "where did they get this turkey?" lol
@I_am_0072 жыл бұрын
Allen key
@chadrayl9648 Жыл бұрын
Horrible
@ANTONYBROWN-jl8fx4 ай бұрын
@@bobboscarato1313p00
@ivispimienta92432 жыл бұрын
Congratulations sir. Very useful this video. Thanks a lot for taking your time to share this valuable information. Thanks
@bobboscarato13132 жыл бұрын
It was a terrible video; very unprofessional..!
@SenthilKumar-gz1ll2 жыл бұрын
anna amazing explaination step by step instructions very thanking sir
@chipchannel1742 жыл бұрын
Welcome
@aneshchopra2 жыл бұрын
Tnx bhai aapki help se aaj maine apne 1000 ₹ bacha liye without mechanic 😀😀😀......tnx
@johnjosephpuntual12643 ай бұрын
thankyou, very simple, and very clear to understand
@garvinjohnson4373 жыл бұрын
I see in the Bahamas where I live the close the big line first then turn the ac on let it run for about a minute or 2 then turn the unit off then close the small line
@punampandit17852 жыл бұрын
Thanks for helpful video Love from Nepal
@VernonGovender-db4tg2 ай бұрын
Thank u I learnt something from you I did try to remove the unit in a different way and did not work now will use ur video ...
@watchtime9072 Жыл бұрын
Brilliant! Thanks for posting.
@LS-ki9nl2 жыл бұрын
Just what I was looking for. Thanks.
@chipchannel1742 жыл бұрын
You are welcome…
@kylekey96192 жыл бұрын
Thanks for the video.
@chipchannel1742 жыл бұрын
Welcome..
@naserdaatomukherchikitshak93633 жыл бұрын
It was very useful video.
@chipchannel1742 жыл бұрын
Thanks
@jordanoliveros35102 жыл бұрын
Good job Sir kahit walang audio pero malinao
@chipchannel1742 жыл бұрын
Thank you..
@thebman8787 Жыл бұрын
Thank you!
@dtb7872 Жыл бұрын
Upon reconnect, did you pump down the system yourself and recharge?
@ddaanniijjeell2 жыл бұрын
Tnx for this 👍💪
@delberttips91772 жыл бұрын
Thank you bro.
@addiszemen16373 жыл бұрын
thank you!
@chipchannel1743 жыл бұрын
Welcome
@diysolaradventures7894 Жыл бұрын
Mine's is in heating mode can I pump it down with the heat running ain't that still sending Freon through the lines
@stvn29183 жыл бұрын
Very useful 👍
@chipchannel1743 жыл бұрын
Thanks a lot
@ariansinanaj8668 Жыл бұрын
You have done good job, thank you very much for detailed video.
@pajayalath99672 жыл бұрын
Thank good video .
@noodles8063 жыл бұрын
Thanks for this! What did you do with the loose power cable after?
@chipchannel1743 жыл бұрын
No longer used. The power cable is from the indoor units.
@noodles8063 жыл бұрын
@@chipchannel174 I should have been more specific. What did you do to secure/stow it safely since it wasn’t being used after?
@chipchannel1743 жыл бұрын
@@noodles806 power cable units usually connected and follow through the cooper pipe with insulation from indoor to outdoor units. If no longer used it then you can just pull or remove those pipe and cables.
@michaelkrakowski28042 жыл бұрын
Hi thanks for the video Does this procedure apply for Inverter AC as well
@chipchannel1742 жыл бұрын
Pump down process required the compressor to run. Should be apply for both system as long as compressor running. Inverter is just providing variable power and speed control to the compressor and fan. This is what Im understanding about the process and system. You may refer to others expert about the AC if you have any concerns.
@quancydang82523 жыл бұрын
thank you! this was helpful!
@chipchannel1743 жыл бұрын
You are welcome..
@sucider54062 жыл бұрын
Very useful 🙏
@chipchannel1742 жыл бұрын
Thank you..
@akkioshin71513 күн бұрын
Great video i wish i watched this one before losing all my gas thanks to the other video i watched where he says to wait 30seconds ..
@letsoajeКүн бұрын
Me too 😢
@mdabdulmoiz3 жыл бұрын
i just want to change the direction of my outdoor unit can I do it myself, now you have shown how to unplug but how do I reconnect this back?
@chipchannel1743 жыл бұрын
Usually for installation required vacuum pump to vacuum the air inside the cooper pipe before release the gas. This video just to show how to disconnect the outdoor unit. You may search for others video for installation guideline. Not much different between relocation and install the new AC.
@dgb5820 Жыл бұрын
Great video
@chipchannel174 Жыл бұрын
Thanks!
@user-sn7wd6bx6t3 жыл бұрын
Good job
@chipchannel1743 жыл бұрын
微微 thank you
@krisztianbalazs78392 ай бұрын
It is a good video and a huge thank you for it but you can use the long side of the alan key too. :)
@shahriljaszle46064 жыл бұрын
Tahniah Bro
@chipchannel1744 жыл бұрын
Untuk rujukan diri sendiri di masa hadapan sama tuan. :)
@Dom75GR2 жыл бұрын
Video helped a lot. Just have a question. Is the proccess the same to re install it ?? Or it needs to by done by a pro with special tools ?
@chipchannel1742 жыл бұрын
Installation no need to turn on the compressor as pump down process. Hook up, release the gas and turn on the AC. Probably need to use gauge to check either has enough gas or not. For better results, please consults your local expert.
@jasonkolb12842 жыл бұрын
@@chipchannel174 don't you need to evacuate the evaporator and line set with a vacuum pump?
@chipchannel1742 жыл бұрын
@@jasonkolb1284 Air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system basically in cooper pipe. Pump down process to move and keep the gas to compressor. Similar to when you buy new AC, the gas already have inside.
@praveenmannam30013 жыл бұрын
Its good if you do its continued part for indoor until outdoor & indoor units kept on floor.
@chipchannel1743 жыл бұрын
Praveen Mannam yes I will if I have job to dismantle indoor unit. I will update in my channel. Thank you.
@ryel0732 жыл бұрын
May i ask you sir i have plan to transfer my AC to other room with by my self. Can i just reconnect the two pipe and cup then reopen that 2 supply? Or can you tell me what to do for Reconnecting? !
@chipchannel1742 жыл бұрын
Basically when you want to reinstall or install the AC, you need vacuum and gauge to clear the air inside the cooper pipe from outdoor to indoor. The reason is to ensure your gas is purely and not mixing with air trap inside the cooper pipe to maximise the cooling operation. But you still can do that.
@RS9World3 жыл бұрын
Can you do this in heating mode? Will the steps be the same?
@chipchannel1743 жыл бұрын
As I know, during pump down need to run or activate the compressor and usually set to lowest temperature.
@boutserk59 ай бұрын
I did it exactly like you said and everything is fine. Thanks
@chipchannel1749 ай бұрын
Welcome
@atuldaware36793 жыл бұрын
Thank u..
@chipchannel1743 жыл бұрын
atul daware welcome
@kazielbonn Жыл бұрын
Waited for ages for the person to switch to the alan wrench's long end.
@barrygaynor1025 Жыл бұрын
Thank you.
@chipchannel174 Жыл бұрын
You're welcome!
@unnikrishna41333 жыл бұрын
Thank you is a small word
@chipchannel1743 жыл бұрын
Please share this video if you think this information helpful. Thanks
@ashishsankrit12903 жыл бұрын
After removing the outdoor unit how to remove the pipe safely from indoor unit is their any connector or any joint ??
@chipchannel1743 жыл бұрын
Yes. There is another joint at indoor unit need to remove. Disconnect the incoming power cable as well. After that you can lift up the indoor unit out from the bracket. Then remove the bracket at wall. That it.
@hamzakhattak5365 Жыл бұрын
A question: you tighten up the gas valve first, after the air is changed from hot to normal you again tighten up the valve, is this process can be done 1 time or it should be done in 2 steps?
@chipchannel174 Жыл бұрын
2 steps since the process is to pull all the gas and keep into outdoor unit. If one time you will lose the gas once you dismantle the cooper pipe.
@stvn29183 жыл бұрын
Is it necessary to switch on before unmantle?
@chipchannel1743 жыл бұрын
Yes sir. Pump down process need to run the compressor in order to flow the gas.
@sonchan362111 ай бұрын
how to put it back again?
@Marsell882 жыл бұрын
Thanks a bunch dude! God bless... Mofos asking for 30-50 euros to dismantle my AC.
@MrBENTPIN Жыл бұрын
Costs.650 to instal one in Australia
@zaidhamid72693 жыл бұрын
Love the black ops 2 intro
@skkadir6553 жыл бұрын
Thanks brother
@chipchannel1743 жыл бұрын
Welcome
@chipchannel1743 жыл бұрын
Please share this video if you think this helpful. Im not an expert but I just share based on my experience and for my reference as well.
@Swenser3 жыл бұрын
I closed liquid line and after a few minutes decided to not pump down but re open liquid line. I expected the system to revert to normal operation, but the compressor cuts of after a few seconds, like there is a problem sensed. I left over 24 hrs to rebalance gas but the compressor still stops after a few seconds and cycles about every minute. What could be the problem after this closing of liquid valve temporarily for a few minutes? Why does the compressor stay on. It was fine before attempted cut short pump down.
@chipchannel1743 жыл бұрын
How long you turn on the AC after re open the valve? What is the temp setting at your AC controller? You can try to set at min temp and run the AC. Usually the compressor will turn off if the indoor sensor detect the temperature tally with the controller setting. Hope this help.
@Swenser3 жыл бұрын
@@chipchannel174 temp was set at minimum. After 24 hrs rest just in case of pressure imbalance or frosting I tried ac on for 15 minutes but always cycled on for a few seconds off about 1 min. Pumping compressor down for a few minutes maybe damaged compressor in my case??
@chipchannel1743 жыл бұрын
@@Swenser please check your liquid line valve again. Could be the valve not fully open or maybe stuck. How’s the room temperature? It’s cool?
@Swenser3 жыл бұрын
@@chipchannel174 warm day in melbourne. gas definitely at schraeder valve. A quick depression of valve confirmed that. No gauge to check pressures. Evap not showing any signs of icing at all.
@chipchannel1743 жыл бұрын
@@Swenser Im facing 1 issue before this outdoor unit not running or intermittence due to not enough gas..need to top up the gas according to outdoor specs then the AC back to normal. You need have gauge to confirm on this.
@GregoryJHill-ub6ow2 жыл бұрын
My copper lines were soldered directly to AC unit. Can I cut these lines?
@chipchannel1742 жыл бұрын
You can cut after pump down and turn off the main supply.
@hansmaier36895 ай бұрын
In case you are in heating mode close gas line and than liquid site?
@chipchannel1745 ай бұрын
This process I just follow the instruction from the service manual for this model. You may refer to your AC model service manual for better view or clarifications.
@Gganp1 Жыл бұрын
very good job, please add audio. Rated number 1. Best ever. Thank you you my $500 I would like to send you a gift certificate.
@chipchannel174 Жыл бұрын
Wow, thanks!
@vishnukannan2363 жыл бұрын
I closed liquid line first and after 4 Minute i closed gas stop valve any problem pls tell
@chipchannel1743 жыл бұрын
Depend on AC HP..if 1 HP with less than 10 feet cooper pipe should be ok.
@joshuacummins20763 жыл бұрын
Do you just do the reverse order to hook it back up. Great video btw!
@chipchannel1743 жыл бұрын
To hook it up with proper way is just need another step which is vacuum the cooper pipe before release the gas. You need to have vacuum and gauge to do this process.
@chipchannel174 Жыл бұрын
@Khanh Phan to install new AC I suggest to follow the actual procedure which is you need gauge and vacuum pump. This video just for special case to disconnect your AC without those equipment. Please refer to AC expert on your area.
@senthilkumars92882 жыл бұрын
Super
@johnpaulcalubay61203 жыл бұрын
Hello is this need to set to highcool to close all the valve to pump down?
@chipchannel1743 жыл бұрын
As long as outdoor unit running.
@viktorponkratov32133 жыл бұрын
👍👍👍
@keerthirajendran59523 жыл бұрын
What is the size of hexagon wrench??
@chipchannel1743 жыл бұрын
Sorry about that. I forgot the size for the Allen keys. I have a set of combinations size so I just try which one is fix. If I have the opportunity to confirm on this I will share in my next videos.
@ralistaduncan8092 Жыл бұрын
Please I need help I did the process successfully, I had little gas come out from the pipe from the indoor unit but now I need to put it back, the gas pipe get frozen white and it won't get cold inside is there something wrong with my unit ?
@chipchannel174 Жыл бұрын
Probably not enough gas i think.
@jaewalker15273 жыл бұрын
Can i do it by turning off the the ac, I’m worried of being electricuted
@chipchannel1743 жыл бұрын
To pump down the gas and keep inside the compressor, you need to follow this steps with running condition. Once done then you can switch off the supply and dismantle the cooper pipe.
@jaewalker15273 жыл бұрын
@@chipchannel174 thanks i did the same procedure...
@akadbakadbombayaboo3 жыл бұрын
How do you know which valve is gas valve and which is liquid valve. The size of both the valve on brivis honbr50 outside unit is nearly same Thanks
@chipchannel1743 жыл бұрын
Please refer product manual for confirmation.
@chipchannel1743 жыл бұрын
The cooper pipe size should be different.
@adamjones9600 Жыл бұрын
Well this work on a vehicle? I would like to remove the ac unit from the vehicle. AC works but car can’t move.
@chipchannel174 Жыл бұрын
Basically should be the same process. Could be better you refer to service manual.
@xylenesavannah5076 Жыл бұрын
what will happen if I just closed all valve without powering the AC for some minutes before do that
@chipchannel174 Жыл бұрын
You will lost the gas inside the pipe and indoor unit. This is not a good practice since you will release the gas to the environment. Also it will cost you during installation because need to top up the gas.
@hlalthanpuia1494 Жыл бұрын
Good video Sir. Is it required to switch on the ac power before dismantling?
@chipchannel174 Жыл бұрын
After pump down completed and all valve are close, you need to turn off the power before dismantle the power cable.
@hlalthanpuia1494 Жыл бұрын
@@chipchannel174 Thank you sir🙏🙏
@flattblackjakus3 жыл бұрын
I have a 7000btu unit with only a 10ft pair of lines hooked up to my school bus conversion. What’s the length of time I should wait till closing the second valve?
@chipchannel1743 жыл бұрын
Thanks for your comment. The proper way is using the gauge or you can refer to installation guide ( pump down ) according to your AC model and brand. Some manual said the duration is 5 minutes or more referring to your lines length. You can feel the hot air blowing turn to normal temperature and you can close the valve. For my case line length also about 10ft. Anyway, Im not an expert but I’m sharing this video based on my experiences.
@Tamiltech360senthil3 жыл бұрын
Nice bro
@chipchannel1743 жыл бұрын
Thanks
@elias.anjel8170Ай бұрын
Hi it have turns on on cooling yeah? I followed your steps but fan still not working, can this steps work if the fan not turning? Thanks
@elias.anjel8170Ай бұрын
Or have turned on heating??
@chipchannel174Ай бұрын
Outdoor compressor need to run for this process. Usually outdoor fan will running if outdoor unit turn on.
@fredericsheridan143627 күн бұрын
When you reinstall the unit is it the same procedure?
@chipchannel17427 күн бұрын
For reinstall you need vacuum to clear the air trap inside the cooper for better results. Procedure should be reverse from dismantle process but you need to check all the connection are good to ensure no leakage.
@curtissharris8914 Жыл бұрын
what's running and what does ....3 after 5 to 10 minutes mean?
@chipchannel174 Жыл бұрын
To let the compressor running and stop the gas flow from outdoor unit to indoor unit.
@normanlatu34982 жыл бұрын
What about if there gas still in the lines?
@chipchannel1742 жыл бұрын
Pump down process actually to pull all the gas inside the pipe and keep inside the the compressor. So, please complete the process to avoid release the gas to environment which will cause the pollution. Second things is you no need to top up the gas or just minimal when you reinstall the AC to others location and will save your money as well.
@unrulian3 жыл бұрын
my problem is board is broken and I can't turn it on but need to remove unit. can you do this without turning unit on?
@chipchannel1743 жыл бұрын
Just close the valve and slowly disconnect the cooper pipe. Please be careful cause it high pressure.
@matttzzz23 жыл бұрын
@@chipchannel174 STOP. NO. You're NOT allowed to just release the gas into the atmosphere. Stop repeating this nonsense to everyone! You have to capture the gas using a recovery unit into an emptg gas bottle that will be dosposed of.
@fartsmccracken14452 жыл бұрын
@@matttzzz2 Screw the environment. I got work to do. Biden’s gonna kill us all anyway.
@avetsuper6272 Жыл бұрын
what about freon from pies ,its gone to air ?
@chipchannel174 Жыл бұрын
That’s the reason of pump down process before dismantle the unit.
@xauyala7 күн бұрын
Thanks
@chipchannel1747 күн бұрын
@@xauyala welcome
@franciskimocop60183 жыл бұрын
What if there is no power ? How can i remove the outdoor unit ?
@chipchannel1743 жыл бұрын
You must have pressure gauge and empty gas bottle to transfer the gas before dismantle the cooper pipe. Do not release the gas to the atmosphere. Please consult your local competent person for help if required.
@bsiah90733 ай бұрын
hey man no need to discharge the gas or liquid before you close the valve or remove the copper pipe? huh
@ralistaduncan8092 Жыл бұрын
Thank you very much
@chipchannel174 Жыл бұрын
You are welcome…
@ralistaduncan8092 Жыл бұрын
Please what's the size of the hexagon key ?
@chipchannel174 Жыл бұрын
@@ralistaduncan8092 sorry, I forgot the hex size because I have a set of it. It may varies depend on model.
@ralistaduncan8092 Жыл бұрын
@@chipchannel174 I had a gas come out the small pipe though the hexagon nut was tight, I hope that's isn't a problem , I'd used it a night before dismantling
@ralistaduncan8092 Жыл бұрын
@@chipchannel174 please I have put it back on and won't get cold inside the gas pipe is frozen white is there something wrong with my unit
@arseniong79402 жыл бұрын
When re installing, then is it same procedure? Ty
@chipchannel1742 жыл бұрын
Can you translate in english please. Tq.
@chipchannel1742 жыл бұрын
For installation you need to have vacuum and guage before release the gas.
@cramemichael20232 жыл бұрын
How did you remove the refrigerant. Where it go.
@chipchannel1742 жыл бұрын
Pump down process is to keep the gas into the compressor.
@imStrato Жыл бұрын
@@chipchannel174 Not in the compressor itself, it does not have capacity to hold average amount of refrigerant. Most of the refrigerant is stored in the condenser tubes.
@jesterrio62512 жыл бұрын
inverter or non inverter the same procedure?
@chipchannel1742 жыл бұрын
Procedure should be the same. The different between this AC type just to control the power. For the duration you may refer to service manual or expert on your area. I just show the step by step process only. Hope this help.
@mike82y2 жыл бұрын
What will happened if u just let u leak out?
@chipchannel1742 жыл бұрын
First, you will contribute to air pollution. Second, you need to refill the gas during installation and cost you more $.
@TheWuzyy2 ай бұрын
For god sake, please use the long end of the hex wrench!
@isumiterracetv5063 жыл бұрын
Oh, for goodness sake, use the long end of the hex wrench until you have to tighten it. Jeez. Like watching paint dry!
@chipchannel1743 жыл бұрын
The reason why I’m slowly turn the hex wrench because of to ensure all the gas flow into the compressor. It’s not just about to close the valve only.
@isumiterracetv5063 жыл бұрын
Yeah, but you finally worked it out towards the end of closing the second valve ;) Anyway, thank you for the video. Most helpful and appreciated. :)
@flattblackjakus3 жыл бұрын
I found it quite soothing and satisfying lol
@isumiterracetv5063 жыл бұрын
hahaha... Good on ya, fella. :)
@JosuRibeiro2 жыл бұрын
@@isumiterracetv506 I was frustrated too... do we need to watch. Every. Single. Turn. Of. That. Wrench?! hahaha but great video tho
@OfficialHowItRuns1.0Ай бұрын
Sir how long to wait for gas valve after tightening the liquid valve?
@chipchannel174Ай бұрын
Depend on AC HP. You can refer service manual for your type of AC.
@hamsterdogcat6 ай бұрын
Thank you sir! But how to make it run again?
@chipchannel1746 ай бұрын
You may refer to others video for installations. .
@maxgrind4382 жыл бұрын
What if the compressor is damaged.?
@chipchannel1742 жыл бұрын
Basically, you need gauge and release the gas into empty container in order to dismantle the outdoor unit. Do not release the gas direct to environment. This video just show the pump down process before dismantle the outdoor units that still function or working well.
@parisparknarzo3 ай бұрын
boss kung matagal nang tengga ang generator, kailangan pa ba e power on para maalis ang mga tubo?
@chipchannel1743 ай бұрын
Translate to english please.
@andrewdefour79803 жыл бұрын
Can you reconnect the same way you disconnect without using vacuum and gauge if the unit was down for less than a month?
@chipchannel1743 жыл бұрын
Once you remove the cooper pipe, better to use vacuum before connect it back.
@nhojjohn40542 жыл бұрын
It's safe if the liquid is leaking? Thnx the AC is not operating
@chipchannel1742 жыл бұрын
Do you mean leaking caused the AC not working or leaking during dismantle?
@nhojjohn40542 жыл бұрын
During dsmqmtle
@chipchannel1742 жыл бұрын
@@nhojjohn4054 if compressor in running condition means during pump down process should be less possibility or in min qty for leaking but of compressor not running there is another process to release the gas. Main point is do not release the gas to the environment which will contribute to the air pollution. You can search about the process and procedure of release the gas without compressor in running condition.
@johnrogers14232 жыл бұрын
Using the shifting spanner the other way around is less likely to damage the spanner.
@carlyncorley91872 жыл бұрын
bang apa mksud pump down sblm tutup valve tu and knpa nak psg ac?
@chipchannel1742 жыл бұрын
Nak sedut dan simpan gas masuk ke dlm compressor sebelum buka paip..kena turn on untuk bg compressor jalan.
@narpavi26513 жыл бұрын
After AC installation first open what pipe
@chipchannel1743 жыл бұрын
Open the liquid valve first and after that open the gas valve.
@PedroAntonio-jw7rr2 жыл бұрын
@@chipchannel174 is the liquid one the bigger line and the gas the small one
@chipchannel1742 жыл бұрын
@@PedroAntonio-jw7rr already mentioned in the process..gas line is the bigger pipe..
@ashishsankrit12903 жыл бұрын
I did it but when I remove pipe still gas is leaking
@chipchannel1743 жыл бұрын
Depend on outdoor unit size or hp..more than 1hp and longer cooper pipe you need to take more time during pump down. Anyway, you still can top up the gas if you want to install at other place.
@alanheng9442 жыл бұрын
Bang, kalo nk check outdoor unit masih berfungsi x mcm mana nk check caranya?sbb sy baru dapat sebiji outdoor dari kawan igt nk pasang kt rumah tapi x pasti masih berfungsi x..tq
@chipchannel1742 жыл бұрын
Boleh direct sambung power cable untuk pastikan compressor berfungsi. Jangan lama sebab bila compressor jalan dlm keadaan valve tutup akan jadi tekanan tinggi.
@alanheng9442 жыл бұрын
@@chipchannel174 tq bang sbb sudi berkongsi ilmu..
@alanheng9442 жыл бұрын
@@chipchannel174 lepas direct sambung kipas berfungsi maksud nya masih elok ke? atau ada petunjuk lain?
@chipchannel1742 жыл бұрын
@@alanheng944 kipas berfungsi kira motor kipas pon masih ok lah..kalau compressor dia ada bunyi dengung sket .
@russelvicencio91943 жыл бұрын
Bossing pag b ptay aircon ng matagal wala nba gas sa piping
@chipchannel1743 жыл бұрын
Sorry I cant understand you..can you translate to english please..
@snowythehusky59122 жыл бұрын
Bro kalau dalam kondisi ada freon seperti ini, apakah aman dibawa pakai mobil untuk dipindahkan? Thank you
@chipchannel1742 жыл бұрын
Tiada masalah..tutup semua valve rapat elok. Sama seperti kita beli AC baru, dlm dia sudah ada freon dah. Untuk pemasangan semula kemungkinan hanya perlu tambah freon sedikit sahaja. Jimat wang.
@azaanusman80393 жыл бұрын
Brother mene ghalti se AC on kiye bagair outdoor seprate krdiya is se jo condenser me gas thi wo waist ho gai brother kitne percent gas meri zaya ho gai ap bta sakte hai
@chipchannel1743 жыл бұрын
Im sorry brother...Im not understand your question. Can you translate it to english?
@chipchannel1743 жыл бұрын
@@RideAdventureMoto do not release the gas to the atmosphere as this will impact the environment...need to have gauge and transfer to empty gas bottle or please consult your local competent person for help.
@AllahMyHeart2 жыл бұрын
What is size of hexagonal wrench?
@chipchannel1742 жыл бұрын
Im sorry..i can’t remember the hex size..you may refer to your AC service manual.
@AllahMyHeart2 жыл бұрын
@@chipchannel174 no problem I asked the shop keeper he told me the size suitable for my ac
@chipchannel1742 жыл бұрын
@@AllahMyHeart May Allah ease everything …amiinn..
@Vii_Tannu2 жыл бұрын
How to re-install it
@chipchannel1742 жыл бұрын
To re-install basically just reverse this process but before you release the gas, you must have the vacuum and gauge to clear all the air trap inside the cooper pipe from outdoor to indoor. This is the correct way to optimise your AC operation.