No video

How to Find Seismic Forces Fast | Simplified Method | ASCE 7-16 | Seismic Design Example

  Рет қаралды 9,402

Kestävä

Kestävä

Күн бұрын

The second half of the lesson is perfect for those taking the PE exam!
Seismic design can actually be pretty simple if you know where to look in the ASCE 7-16. Today the team goes step by step through the ASCE 7-16 using the simplified seismic design method. We cover a real PE exam seismic example problem that you could very well see on the EXAM! We just got new leather seats in the auditorium so get comfy, and if you're nervous about seismic, we got ice cold Avion water for ya.
👇 SUBSCRIBE TO KESTÄVÄ ENGINEERING’S KZfaq CHANNEL 👇
/ @kestava_engineering
For business inquiries email: kestavallc@gmail.com
Connect with me on LinkedIn 👇
/ richard-racz-pe-620b1792
Civil PE exam will be here before you know it!
(Check NCEES website to confirm time, date, and location!!)
NCEES Website 👇
ncees.org/
Brave Browser 👇
brave.com/
(I am not affiliated or receive compensation from Brave)
Music I Use 👇
www.epidemicso...
.
.
.
.
.
.
.
.
.
Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
The Kestävä Engineering KZfaq page is intended for informational purposes only. Nothing contained in, or provided through, this KZfaq page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
Under no circumstances will Kestävä Engineering be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this KZfaq page.
#Seismic #structuralengineer #earthquakeengineering

Пікірлер: 18
@oldpretoriagmailcom
@oldpretoriagmailcom 3 жыл бұрын
Jose been waiting for this one!
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
Jose low key helping out this team
@jkslam000
@jkslam000 3 жыл бұрын
This is so helpful. Thank you so much!
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
you're very welcome Jay Kim! thanks for being a member of team kestava!
@90clemson
@90clemson 2 жыл бұрын
Very helpful. Keep up the great work.
@chris12159
@chris12159 3 жыл бұрын
Love your video! best channel for PE on youtube!!! wait for your wind load calculation =P
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
Wind examples coming up! I know I've been promising wind for a while now. Thanks for being a senior team member Yu Chung and supporting this channel!
@ehabaltimimi660
@ehabaltimimi660 3 жыл бұрын
Perfect
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
no your perfect
@mohdshadab-ug2ut
@mohdshadab-ug2ut 2 жыл бұрын
Thanks, how apply this base shear to each member of structure....
@danielstoesser341
@danielstoesser341 2 жыл бұрын
Is the value for W always added straight accross or would you ever use load combinations?
@komaldeepsingh3265
@komaldeepsingh3265 2 жыл бұрын
The code says the portion of deal load load assigned to level x (not the full dead load). I guess since they are asking for the nearest value, so 2000 is the closet one. But In real life scenario for same example, it will be the dead load of floor 2 + walls + roof (in other words, all the dead load above that point). Is that right?
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
its the DL at that level, which would be the floor + 1/2 walls from below and 1/2 walls from above.
@RobertoRojas-os5gk
@RobertoRojas-os5gk 2 жыл бұрын
your answer does not match with the answers A thru D???
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Robert go to 7:05 that is the answer for the problem but then I add additional information to go outside of the problem to explain seismic forces
@rjkebz312
@rjkebz312 Жыл бұрын
The title is misleading. This is only applicable to structures located in none seismic prone area.
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
sorry for the confusion - this is the simplified method (which is only permitted for seismic design category A)
@maciejcichy6018
@maciejcichy6018 5 ай бұрын
@@Kestava_Engineering I think it is not only for A. In 12.14.1.1 it includes A, B, C, D, if a building has maximum 3 stories above grade, and meets other conditions. It should be usfule for light frame residential, as for that type share walls offsets are permited (up to 2 storyes). This method is used in WFCM for dwellings in table 2.6.
Check This Before You Leave for the PE EXAM | Spring 2021
3:56
Kestävä
Рет қаралды 1,6 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 3,6 МЛН
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 84 МЛН
Magic? 😨
00:14
Andrey Grechka
Рет қаралды 20 МЛН
Schoolboy Runaway в реальной жизни🤣@onLI_gAmeS
00:31
МишАня
Рет қаралды 3,9 МЛН
How to Design a Weld For TORSIONAL Loads | Civil PE Exam Prep
12:53
Think Fast, Talk Smart: Communication Techniques
58:20
Stanford Graduate School of Business
Рет қаралды 39 МЛН
PE Seismic Review: How to Calculate Chord and Collector Forces
19:31
Seismic Load Calc Example
27:48
professordeb
Рет қаралды 45 М.
КТО ЛЮБИТ ГРИБЫ?? #shorts
00:24
Паша Осадчий
Рет қаралды 3,6 МЛН