Rigid Diaphragm Design Example | Shear Wall Force Distribution | By Hand | Complete walkthrough

  Рет қаралды 13,726

Kestävä

Kestävä

3 жыл бұрын

The last half really brings this example together. HANG IN THERE TEAM.
This is a long one but I swear it'll help you learn rigid diaphragms. We are way past flexible diaphragm design and onto BIG KID rigid diaphragms. Today we have a perfect structural engineering design example of a rigid diaphragm where we figure out how to distribute lateral forces to shear walls. And the best part... its a full example by hand, perfect for your college homework or preparation for the the up coming civil PE exam!
The civil PE exam is this MONTH! GOOD LUCK EVERYONE. this entire team is behind you and in your corner. knock em out baby.
👇 SUBSCRIBE TO KESTÄVÄ ENGINEERING’S KZfaq CHANNEL 👇
/ @kestava_engineering
For business inquiries email: kestavallc@gmail.com
Connect with me on LinkedIn 👇
/ richard-racz-pe-620b1792
Civil PE exam will be here before you know it!
(Check NCEES website to confirm time, date, and location!!)
NCEES Website 👇
ncees.org/
Brave Browser 👇
brave.com/
(I am not affiliated or receive compensation from Brave)
Music I Use 👇
www.epidemicsound.com/
.
.
.
.
.
.
.
.
.
Disclaimers: Richard Racz, P.E. does not hold the title "structural engineer". Any claim of it in the videos or descriptions is unintentional and is superseded by the title "civil engineer" in the states of MA and OR.
The Kestävä Engineering KZfaq page is intended for informational purposes only. Nothing contained in, or provided through, this KZfaq page is intended to constitute advice, or to serve as a substitute for the advice of an engineering professional. Any reliance you place on such information is strictly at your own risk.
Under no circumstances will Kestävä Engineering be responsible or liable in any way for any content, including but not limited to, any errors or omissions in the content, or for any loss or damage of any kind incurred as a result of any content communicated on this KZfaq page.
#kestavaengineering #structuralengineer #civilengineering

Пікірлер: 46
@mmgedi
@mmgedi 2 жыл бұрын
Thanks for sharing great content. Just a quick question. Isn't Mt about CR and shear force (V) acts at CM hence creating clockwise moment (Mt) ?
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
ohhhhh MO you got me! you are 100% correct - i meant to say the moment M is acting about the center of rotation Cr and the force V is applied at the center of mass Cm the moment arm is the eccentricity e between Cm and Cr and thus creates a clockwise moment about Cr. You just got pinned to the top homie! very good catch. I ended up doing the rest of the problem correctly (thankfully) but graphically showed that error on my part. BIG FLEX Mo
@purshep
@purshep 2 жыл бұрын
I passed the PE 6 months ago thanks to your video and I am 62 years old. I am trying to pass the SE and took it last week.
@Jzns82
@Jzns82 2 жыл бұрын
I’m rally stoked about watching this. Been struggling the past few days with an open front structure with a job at work. Thanks
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
All hail the Pen of Learning
@user-ux3nh4iw3y
@user-ux3nh4iw3y 2 жыл бұрын
Very valuable guide! Before i watched that i did not know how to account for the potion of V due to Mt. Now i know
@jjmontoya21
@jjmontoya21 3 жыл бұрын
You rock Rich!
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
Jeremy you're making e blush, I do it all for the team.
@mohammadzare5070
@mohammadzare5070 2 жыл бұрын
very nice, thanks.
@mfgman2011
@mfgman2011 3 жыл бұрын
Thanks for all the work you put into these. I'm a Mechanical Eng PE and I'm taking the SE exam in a few weeks.
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
mfgman get after it! good luck and let me and the team know how it goes. I didnt realize ME's take the SE. Is that normal or are you just straight flexin?
@mfgman2011
@mfgman2011 3 жыл бұрын
@@Kestava_Engineering it's more of a decision for me to ensure I keep my business strong. I own Quanta Engineering in Olathe, KS. I spend a lot of my time designing small wind turbine and telecom towers and small steel structural shelters. A lot of states require an SE stamp. So, for me, getting an SE keeps the outside guy from taking my role.
@mienge2177
@mienge2177 2 жыл бұрын
Yes, please do reinforce the concrete shear wall too. Thanks. The more real-life problems the better.
@filipimarcondes3838
@filipimarcondes3838 3 жыл бұрын
Thanks buddy!!!
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
Any time Filipi
@nirmal3307
@nirmal3307 4 ай бұрын
Thank you so much for the great explanation! Will the external force acts to Center of Mass or Center of Rigidity?
@subodhchandraapal3527
@subodhchandraapal3527 2 жыл бұрын
thank you sir.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
you're very welcome!
@mohammadzare5070
@mohammadzare5070 2 жыл бұрын
i guess it should probably be better to consider X and Y signs when you were arranging your table, since these signs will later affect on the value of the torsional shear force (second portion of the formula). like for shear wall 4, we can not use (+20 ft) in the second term of the formula, since we need to use -20 ft. you agree with that?
@mohammedalsharif5395
@mohammedalsharif5395 28 күн бұрын
I just want to highlight something, in some cases the shear from torsion effect shall be in negative value (wall 4 for example)
@Kestava_Engineering
@Kestava_Engineering 17 күн бұрын
spot on - I need to redo a rigid diaphragm analysis
@abdallahothman717
@abdallahothman717 Жыл бұрын
Thank very much ❤️ What if center of mass and center of rigidity was found in void area in slab Is that problem??
@bonegrubber
@bonegrubber 3 жыл бұрын
If there were two shear walls instead of one where shear wall 4 is, would Why-Bar be the same for both of them? The distance to the center of RIgidity?
@eddyz90
@eddyz90 3 ай бұрын
Just curious, why isnt the sum of the 2 shear components a Vector like with Bolt groups. i'd like to avoid the damn vector calcs on the bolt groups lol
@tysongill99
@tysongill99 2 жыл бұрын
the torsional moment is counter clockwise which means the shear resulting from it in wall 2 acts against the base shear. So shouldn't you subtract the torsional moment from wall 2. Its wall 4 you would add the torsional shear since on that side its acting in the same direction as the shear.
@Soli_KicksTV
@Soli_KicksTV 3 жыл бұрын
Thanks Man!! Do you think you can do a full example for a reinforced masonry wall using the TMS 402/ 602-16 code?
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
oh baby baby that sounds fun. gunna take me a liitle bit to get one together but think thats a great idea!
@Soli_KicksTV
@Soli_KicksTV 3 жыл бұрын
@@Kestava_Engineering that will be awesome!!
@rushabhsonaiya7601
@rushabhsonaiya7601 2 жыл бұрын
hey. could you please answer this query. how do rcc slabs act in real life structures as rigid or semi rigid diaphragms when lateral forces act on them.are they designed for any lateral forces ?
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
reinforced concrete slabs (as I understand it) can be conservatively analyzed as rigid diaphragms if they have sufficient in-plane stiffness. However, if required, a RCC diaphragm can be analyzed as semi-rigid, and if done correctly, should give you a more efficient and refined diaphragm. Most of the time a semi-rigid analysis is required by code or when you believe you will have in-plane deformation issues. I believe RCC slabs ideally act as semi rigid systems in real life to some degree but it depends of slab properties and geometry, but please double check me!
@ericschmitz1372
@ericschmitz1372 2 жыл бұрын
Rich, if we want to dive into rigid diaphragms some more, what code book or reference material were you getting your equations from? Or where would you recommend we go to learn more? Please don't say Wikipedia.
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Hi Eric - I have a structural engineering reference manual that has a great example. I would also point you to the SEAOC design manuals. they have A LOT of great content for diaphragm design. no WIKI up in here!
@zozy5932
@zozy5932 3 жыл бұрын
Great ! Can you help us and post video about how to design diaphragm horizontally please 🙏
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
Hi zozo - consider it added to the list!
@qureshisiddig9274
@qureshisiddig9274 2 жыл бұрын
Hello why would we need to make one of the shear wall thicker than the others?
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
you could have forces on another story above with a dissimilar footprint that requires a thicker shear wall on the ground floor. thats just one example tho.
@bonegrubber
@bonegrubber 3 жыл бұрын
If I figured all the shear walls were the same thickness and height but varied only by length, could I accurately state that R is equal to 1, so my Resistance value is simply the lengths of each of my shear walls? Joes told me to ask that one
@Kestava_Engineering
@Kestava_Engineering 2 жыл бұрын
I believe the answer to that one is yes Matt!
@isla2974
@isla2974 2 жыл бұрын
@@Kestava_Engineering Hi Kestava! A struggling/ bad engineer here. But, I will still make a comment. As a shear wall resists through in plane bending, the increase in length of a shearwall adds enormously to the rigidity of a shearwall, based on the formula bh^3/12. So, if the length of a shearwall is increased twice, the rigidity will increase by 7 times. Hence, the distribution of load will not be proportional to the length of the shearwall.
@leoads
@leoads Жыл бұрын
For the torsional part, the unit dimensions don’t match. The way you did you should had kip*ft^2 as a resultant force due the torsional moments. I believe that you should divide the torsional moments by the lever arm, not multiplying it. Thus, you can get the right units.
@Kestava_Engineering
@Kestava_Engineering Жыл бұрын
Yes I agree - I was definitely sloppier back then and really need to redo this video more clearly!
@paigeherbert9319
@paigeherbert9319 7 ай бұрын
I was thinking Ip has units of ft^2 even tho not written out. So that way the units do work out and you don't need to divide by lever arm as suggested.
@bonegrubber
@bonegrubber 3 жыл бұрын
Jose keeps saying "eye why why?!"
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
Matt don't let Jose convert you to the DARK SIDE.... like the side of the auditorium with the light out...next to the popcorn machine where he sits. DONT DO IT
@michaelwolf703
@michaelwolf703 3 жыл бұрын
jesus there is so many adverts
@Kestava_Engineering
@Kestava_Engineering 3 жыл бұрын
crap really!!? Im just leaning about ads now. Ill do my best to tailor it better. Its 100% about the content and information ALWAYS Michael!
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 29 МЛН
How Many Balloons Does It Take To Fly?
00:18
MrBeast
Рет қаралды 139 МЛН
Flexible Diaphragm Collector Demand
9:55
Tonatiuh Rodriguez Nikl
Рет қаралды 3,8 М.
Is The Redundancy Factor 1.0 or 1.3 | Kestava 2022
11:11
Kestävä
Рет қаралды 3 М.
Webinar | Calculating Wood Shear Walls Capacity Webinar
1:00:50
ClearCalcs
Рет қаралды 2,2 М.
Engineer Explains: Structural Forces
10:42
Brendan Hasty
Рет қаралды 4,6 М.
Why Retaining Walls Collapse
12:51
Practical Engineering
Рет қаралды 3 МЛН
Shear Exhilaration: Wood Shear Wall and Diaphragm Design per the 2021 IBC
59:44
APA – The Engineered Wood Association
Рет қаралды 6 М.
Concrete Diaphragm - Grad Engineer Mistake
5:23
BEng The Brazilian Engineer in Australia
Рет қаралды 5 М.
마시멜로우로 체감되는 요즘 물가
00:20
진영민yeongmin
Рет қаралды 29 МЛН