@Tshizzle42o
@Tshizzle42o 6 жыл бұрын
I have helped replace 3 well pumps over the past few years at work. All over 200' 2" galvanised pipe. We use a front end loader, heavy steel cable and a couple pipe vices to keep the pipe in place while moving the cable. It is slow but way cheaper than having a company come out.
@Slavolko
@Slavolko 3 жыл бұрын
We do it with a front end loader as well. We've got at least 300 m of piping, so it takes an eternity to raise and lower.
@ElectrifiedStud
@ElectrifiedStud 2 жыл бұрын
Its the rat race of time vs money, whichever cheaper wins.
@quasisentient8970
@quasisentient8970 7 жыл бұрын
Thank you for making such a high quality and thorough video.
@heerhenapatel2214
@heerhenapatel2214 7 жыл бұрын
Quasi Sentient I
@heerhenapatel2214
@heerhenapatel2214 7 жыл бұрын
Quasi Sentient
@contreeman
@contreeman 10 жыл бұрын
KEEP TEACHING I'M STILL LEARNING GOD BLESS
@moayadsaeed
@moayadsaeed 6 жыл бұрын
Thanks for this video. I am in the UK trying to drill my own borehole, and i need such info. very good. many thanks.
@poopypuppyproductions7409
@poopypuppyproductions7409 5 жыл бұрын
Well, pip-pip, cherri-O and all that rot, ya know. lol Ya-all come back here, ya know?
@tuckerdave1
@tuckerdave1 10 жыл бұрын
Thanks for another grate video . If you have not installed you offset lines to the house yet . Do yourself a favor and put 4 wire to the well . That way if things get shut down ( SHF) and you can only get a three wire pump , you will have the wire in the ground all ready . I use three wire pumps because you have a control box in the basement and that has your start capacitor in it . With a two wire pump , that is build into the motor , so if it get hit by lightning or just fails , you need to pull the pump and replace the motor . Tree wire pumps most of my service calls you can just change the box in the basement . Also install the cycle stop valve you talked about in the video . That way you do not need a big tank . You really don't get any grate storage from BIGER tanks , and you save a lot of cash . Myself I would use a cycle stop , 35 gal tank with 38 psi in blather , heavy release vale and turn PSI up to turn on at 40 PSI and shut off at 75 or 80 PSI . It's better for the pump to run higher PSi because it holds good PSI on the bearing witch is better for your pump . Hope that helps and not mad for my thoughts . Thanks again
@robertdoell4321
@robertdoell4321 4 жыл бұрын
Thank You for your input. I think it was better than the video.
@richardnailhistorical3445
@richardnailhistorical3445 2 жыл бұрын
Let me ask a question: Is 75psi too high for residential piping? Is a constant pressure pump better? Would u install a 'manual' pump also as back up? Are there filters that can be put on pump to prevent debris pick up from well to pump? Thanks
@michiganporter
@michiganporter 3 жыл бұрын
Love the old man! They dont make guys like this anymore.
@ElectrifiedStud
@ElectrifiedStud 2 жыл бұрын
Not true.. Its more like, men like him don't want deal with most of you anymore. Reasons galore.
@acehobojoe
@acehobojoe 8 жыл бұрын
I'm so glad I found this on youtube.
@carolinaprepper540
@carolinaprepper540 10 жыл бұрын
great video !!!! Your camera man did a great job !!! a lot of people don't know how to take a good video. I really enjoyed watching it !
@wyattoneable
@wyattoneable 10 жыл бұрын
A very nice install. I enjoyed the process.
@abdallahmohammed1997
@abdallahmohammed1997 9 жыл бұрын
Keep on teaching, people must do something which they know by learning not by presumption
@maureen2597
@maureen2597 2 жыл бұрын
L
@hiscifi2986
@hiscifi2986 4 жыл бұрын
Just had a well drilled at a neighbour's house, it has enough head to reach 20 foot above ground level. He still used a pump, because he wanted more flow. The pump doubled the free flow.
@skoal022
@skoal022 4 жыл бұрын
Hope mine does too! Lol
@timidater4803
@timidater4803 8 жыл бұрын
what size pipe do you use for the hand pump? Looked like 1"-11/4" for the submersible.
@johnstryker8619
@johnstryker8619 8 жыл бұрын
What a cool old-timer!
@DowntownSound1
@DowntownSound1 6 жыл бұрын
John Stryker ---He doin it right👍
@no3ruben
@no3ruben 6 жыл бұрын
so how deep was the well and at what dept have you installed the pump? also in what state are you installing this pump?? I see you haven't used pitless adaptor .. I just had my well drilled at 305 ft with 50GPM and shopping around for a good pump to install myself.. be blessed.
@ooakiny
@ooakiny 7 жыл бұрын
Great video! Currently troubleshooting a collapsed well with an ESP. Found video very helpful understanding ESP installation in the first place....
@Beniamin6665
@Beniamin6665 2 жыл бұрын
How did it turn up ? You had to re drill it eh?
@ooakiny
@ooakiny 2 жыл бұрын
Correct! Had to re-drill a new well, unfortunately.
@Beniamin6665
@Beniamin6665 2 жыл бұрын
@@ooakiny Thanks for the response eh.. Hope it worked out for you.
@PBS-nm1uu
@PBS-nm1uu 7 жыл бұрын
could you make a list of all the components used, including the size of the pipes ? thanks
@chrishardeen1017
@chrishardeen1017 7 жыл бұрын
nice informative video. just had mine done. they placed a 40 gallon tank next to this well. does your setup require one?
@galegregory97comcast
@galegregory97comcast 7 жыл бұрын
did you say it is a backup Hand pump as well ??
@sofiac8121
@sofiac8121 6 жыл бұрын
Does anyone know how to make a well cover like the one he has? Or the name of it? I have no idea how to start creating that. I also need 3 separate holes for wires, water pipe, and air valve, kind of like what he has. Thanks!
@Mitalayeka
@Mitalayeka 4 жыл бұрын
Thanks for the education, this has been helpful.
@davidmc2861
@davidmc2861 4 жыл бұрын
This isn't a criticism, I'm just now preparing to have a well drilled myself so I'm trying to get educated. I noticed that there wasn't a place on the well pump for a safety rope (way to retrieve the pump) do you feel that it isn't necessary if you use scheduled 80 PVC ? and why no pitless adapter?
@alansabin7487
@alansabin7487 Жыл бұрын
be sure to add a cable or a poly rope to pump as to take some pressure off your pipe. it also saves the pump if pipe breaks in well. steel or stainless steel will get ate up if you have sulfur or hard water, use a poly rope at that point. take care thanks
@pamruthlogie5242
@pamruthlogie5242 4 жыл бұрын
I need help to convert my well that i pay to fill to a well that pulls from the ground. Any plumbers in the Dunville area that can help me out and the cost, please. Thanks Pamela
@tapfumamanhanga
@tapfumamanhanga 2 жыл бұрын
Thank you for the very informative video. I have a water well and I would like to have a submersible pump installed
@hamidahlouch7727
@hamidahlouch7727 3 жыл бұрын
Thanks for the video. We are very dry in Morocco these last three decades: we realy need this knowladge . Thank you
@bago1486
@bago1486 7 жыл бұрын
thanks a lot, learn a lot with you videos..God Bless
@rchopp
@rchopp 10 жыл бұрын
Excellent video, Thanks
@robertjpayne
@robertjpayne Жыл бұрын
Hi - can you drop one of this submersibles down a conventional well (meter diameter , 30 meters) or does it only work in a bore hole?
@dan2soy191
@dan2soy191 3 жыл бұрын
Hi, whats the purpose of the black rubber placed on top of the pump, is that stabilizer? Thanks
@kettlienicolas5413
@kettlienicolas5413 4 жыл бұрын
Thank you guys for sharing👍
@alexafanasiev8014
@alexafanasiev8014 9 жыл бұрын
Thank you for a video. Does the pump sits are the bottom or it hangs above the bottom? If it hangs, how far away from the bottom it should be?
@jameshipp6475
@jameshipp6475 3 жыл бұрын
Depends on how much water the well puts out- you put the pump far enough under the water so it won't suck down
@baddonkey6876
@baddonkey6876 4 жыл бұрын
Out in the deep country we ran rope parallel to the waterline to bear the weight of the pump
@ismaelcherymedia
@ismaelcherymedia 7 жыл бұрын
Can you provide us with the name of the pump or a link where we can find it?
@DOTdirtbiker
@DOTdirtbiker 7 жыл бұрын
ok, i think I want one of these style caps. can you help me get and or install this? I'll show the video to the well driller repair man, but I doubt he'll want to follow some other guy's method after doing his way for 40 years. I am near benton harbor, Michigan.
@mkbdiy9766
@mkbdiy9766 3 ай бұрын
I am planning on having a similar (solar) pump installed, but my water would be stored in a tank, well above the ground and flow down by gravity for use. Would you recommend placing a 3-stage water filter in-line with this pump above ground of course, or would a secondary booster pump be necessary after the storage tank?
@ticvac
@ticvac 6 жыл бұрын
I like the cool old man he knows whats going on!!!
@kbultray
@kbultray 10 жыл бұрын
Useful video E775 Tell me, what was the cost of having the well drilled + any surveys carried out prior to operation? Do you need a permit to drill in US ?
@pedrollopumpsstation
@pedrollopumpsstation 3 жыл бұрын
I will be happy to know as well. Kindly support by subscribing kzfaq.info/get/bejne/g86jlMJonbvSqnU.htmlsub_confimation=1
@zwellybryanmasuku3540
@zwellybryanmasuku3540 6 жыл бұрын
how many metres from the well floor should i place the pump
@kokopelli314
@kokopelli314 5 жыл бұрын
What keeps it from freezing?
@gjakovagjakova4904
@gjakovagjakova4904 4 жыл бұрын
Congratulation......you are doing the best job....
@mujeeb608208
@mujeeb608208 7 жыл бұрын
SIR ..HOW DO I FIND CORRECT LOCATION POINT OF GROUNDWATER ON SLOPE
@dand7056
@dand7056 2 жыл бұрын
Hey 777. I have a 4 inch casing and a 2inch discharge on my 5hp pump with metal pipe . Do you think the simple pump will even fit inside the 4inch? The wires plus the 2 inch coupler on the pipe being the tightest spot that it has to slip by. Also how difficult is it to pump from your static level?
@ElectrifiedStud
@ElectrifiedStud 2 жыл бұрын
Always have 20% more tube/casing dia than the inserting object.
@davidlalnuntluanga387
@davidlalnuntluanga387 3 жыл бұрын
Thank you for helping out .
@sudeeplsingh
@sudeeplsingh 6 жыл бұрын
Please suggest foot valve fall and stuck in the bore well in process of replacement. trying to take it out is not working , please suggest way. since it is not letting us extend water supply pipe.
@ManojVarsani
@ManojVarsani 6 жыл бұрын
will u share how u drill water well? i want see waterwell machine
@spewdog
@spewdog 4 жыл бұрын
Is that electrical tape used to secure the wire to outside of pipe?
@Bigelowbrook
@Bigelowbrook 10 жыл бұрын
I was surprised to see the plastic well casing. We have to have steel casing driven into ledge/bedrock. Our well is 800' and we get 1/4 gallon per minute. ;-)
@soggybuilders
@soggybuilders 10 жыл бұрын
Goodness gracious 800 ft. , 1/4 gallon per minute , I feel for you my friend . I just had a well done in southern Mo. highlands , driller was telling me he just did a well In Arkansas 700 ft. 4 gallon a minute , I thought that was sad , mine went 310 ft. at 20 gal a minute , metal casing with a sch. 40 PVC liner , hit bedrock at 160 ft. , 9400 bucks , you can bet I was glad when that was over . wore me out and all I did was watch .Ha!
@soggybuilders
@soggybuilders 10 жыл бұрын
***** Hi ya neighbor ! Not likely you could ' DIG ' it yourself , the ground around here is way to rocky and hard and you might hit a gigantic boulder then what ?. Even my garden beds are all raised beds , which is really not a big deal . How deep ? Varies I am at 1475 ft. above sea level ,which is pretty elevated ,I am on the Ozark Highlands , my neighbor 3/4 mile to the south is just under 400 ft deep . Best to hire a rep-ital well driller , be careful though you can get scammed real easy !!!!!!!!! My well was pretty pricey but I went the extra mile so to speak, with a double well casing , be mindful well drillers usually only drill the well , meaning they will not do any trenching or backhoe work you are responsible for that being said you have to arraign for a backhoe to run the water line to install tank elect ect . or you will not be able to check if you well even works .Best to budget 10,000 $ and hope it works out less , I budgeted 7500 and it went 9400 plus back hoe work ! Hope this helped you out . Happy trails !
@troyb.4101
@troyb.4101 9 жыл бұрын
Bigelow Brook Farm (Web4Deb) I actually wish my 80' wells were plastic, as they would not rust.
@troyb.4101
@troyb.4101 9 жыл бұрын
mandewey3456 Most the wells here are 80/120 ft deep total they can produce normally 35 to 350 gpm. We're sitting on the largest water table in the state.
@troyb.4101
@troyb.4101 9 жыл бұрын
***** depend on how close to the water you are. Some people here dug the wells about 45' by hand.
@Crogon
@Crogon 4 жыл бұрын
The first and last thing I noticed was how close the casing is to being on grade. All the ones I've seen out here are at least 18 inches above grade.
@kaviedits27
@kaviedits27 7 жыл бұрын
what type PVC pipe
@osmanturay5440
@osmanturay5440 4 жыл бұрын
Great work please let me know how to installed pump in a boreholes pls help me
@hea-libertyhawk3418
@hea-libertyhawk3418 6 жыл бұрын
Countreeman - There wasn’t any teaching going on here! All they did was talk about arresters, back up hand pumps, water flow rates, and water levels! Useless information for replacing an existing pump! I’m a handy sort of guy, but I know little to nothing about well pumps. I can learn most anything about this stuff. If this video was informative, I would know more right now! To get someone to come out with all that equipment would be very expensive, and I don’t have equipment like that! I called the only well guy locally, and he was going to charge me over $2200 to do what this guy did! A lot of help this was! It was a total waste of time!
@gmane1989
@gmane1989 3 жыл бұрын
This is exactly what I do everyday and drilling wells as well down here on the Texas gulf coast. Ok g2g gotta work in the am lol
@lcvt8023
@lcvt8023 3 жыл бұрын
I was just thinking, young dudes or dudeetts would be smart to get into the well water biz. and here you are. good for you man, it sounds like your enjoining it.
@user-fo2qv3pk4u
@user-fo2qv3pk4u 5 ай бұрын
Hi,how can I rapier 1.5 h/p,when it's Jacking in water, and yielding points or level of water is high enough?
@kutlobrockrowland4900
@kutlobrockrowland4900 10 ай бұрын
I want to know which cable size you can use when submersible pump is at 200m in depth
@lukejones1244
@lukejones1244 3 жыл бұрын
Didnt see you plumb the hand pump. How did you do it?
@danstrayer111
@danstrayer111 6 жыл бұрын
Why no pitless adaptor?
@82dockmaster
@82dockmaster 4 жыл бұрын
Question: what if the the pump is accidentally disconnected from the pipe, is there any way to recover it?
@engineer775
@engineer775 4 жыл бұрын
If it does disconnect it's usually still connected to the wire so you have a chance of pulling it up. If not there are fishing tools that allow you to hook on to the pump and retrieve it
@lorax1968
@lorax1968 10 жыл бұрын
I'm guessing you don't have to worry about freezing? here in NYS we would have to have a pit below frost line, and a frost free hand pump...
@Splungers
@Splungers 6 жыл бұрын
South Carolina tags on the well truck.
@johnnybarbar7435
@johnnybarbar7435 3 жыл бұрын
Did I miss the stand offs to keep the pipe and wire from rubbing the well shaft? If not use and installed correctly on a fairly deep well, you will be replacing the wiring down the road before long.
@markwilliams4525
@markwilliams4525 3 жыл бұрын
No one uses those stand offs. Out of the 21 years I've been doing it I've never seen them on an install
@markwilliams4525
@markwilliams4525 3 жыл бұрын
The only time I've seen rubbed wire is when someone sets the pump below the casing into the rough lime rock
@terrystockstill251
@terrystockstill251 5 жыл бұрын
how do u pull a submersible or put it back down its stuck
@realworldprepper
@realworldprepper 10 жыл бұрын
Very informative, thank you for sharing.
@kilimaniconsult423
@kilimaniconsult423 9 ай бұрын
Kindly share about this specific installation truck. Specs and supplier. Thanks to you. Good work
@irahays3566
@irahays3566 8 жыл бұрын
Up here in Canada we run Well temps about 42 - 44. I would of never imagined using a schedule grade glue pipe to suspend a pump, I would think it would come apart or bust.
@engineer775
@engineer775 8 жыл бұрын
+Ira Hays Those were all threaded pipes. No glue just Teflon pipe dope on the threads.
@unitedairforcepilot
@unitedairforcepilot 8 жыл бұрын
That was clearly mentioned in the video
@Daedalus2801
@Daedalus2801 7 жыл бұрын
We don't use pipes like that, We use poly makes it a lot easier to maintain later down the line
@DOTdirtbiker
@DOTdirtbiker 7 жыл бұрын
+Daedalus2801 but then are you still able to put in those check valves every however many feet?
@Daedalus2801
@Daedalus2801 7 жыл бұрын
We put the check valves on the top of the pump
@javier932511
@javier932511 8 жыл бұрын
Hi, I like too much your videos! I wonder if the sumersible pump like the video works in a little lake
@leosgarcia3442
@leosgarcia3442 3 жыл бұрын
I could TRY to do it but I've been looking for someone to do it for me and I've got NOTHING. I already have the well with pipe coming up. Jus need running water. I'm gonna keep watching n learning
@trishincyberspace
@trishincyberspace 8 жыл бұрын
Great work! Is that a commercially-manufactured vehicle with hoist that you are using, or is it one that you have built/put together yourself?
@kennykemp2790
@kennykemp2790 6 жыл бұрын
The rig looks like a 5t smeal pump hoist. They are quite popular and I'm guessing there are thousands out there now. The company is now called Hunke Manufacturing.
@noriebagovlog1104
@noriebagovlog1104 2 жыл бұрын
Great video
@elcidbob
@elcidbob 5 жыл бұрын
The problem with backflow through an impeller pump isn't it running back through the pump hammering stuff. It's that if the reverse flow gets the impeller spinning fast enough and it kicks back on there's a stupid amount of force that the impeller will have to absorb as it tries to start spinning the other direction. Depending on how your electrical is set up , there could be a problem with the generated electricity, but I'm not sure on household stuff.
@trey8543
@trey8543 9 жыл бұрын
So how do you keep the pump from picking up sediment and dirt? Or does all that clear up after pumping for awhile? Also how far from the bottom of the hole do you set the pump? Thanks!
@troyb.4101
@troyb.4101 9 жыл бұрын
Trey clark ten foot is the normal from bottom in these parts, wells are very shallow he most only 80' hitting water at 20'
@gardenoftruth8265
@gardenoftruth8265 4 жыл бұрын
That thrust blocks not big enough that's for a 4 inch well notice it doesn't even hit the sides of the casing how is it going to stabilize the pump
@johndemaria7689
@johndemaria7689 Жыл бұрын
Hey man I had a question about where you sourced the pvc pipe?
@bigwill1112
@bigwill1112 6 жыл бұрын
Ok he said something about a check in line. How many feet do you put one of those in?
@csmooth569
@csmooth569 4 жыл бұрын
Big Will every 200 ft is pretty average
@seannesy5439
@seannesy5439 6 жыл бұрын
how deep is your water level ?
@arshikhur6773
@arshikhur6773 9 жыл бұрын
I ujst want double check, what you are saying is to add a check valve every 100 ft?
@jimmytate7587
@jimmytate7587 6 жыл бұрын
yes that's what he is saying. water will weigh considerable when pumped long distances and it can actually break the pipe if sufficient check valves are not installed.
@rickw2776
@rickw2776 8 жыл бұрын
I'm in SW Utah and our 200 foot deep well pump has failed after seven years. The company, Gardner Wells, installed it initially and I recommend them to anyone. I wish I knew what I know now when they installed it so I had a better idea of what was going on. However, I have rung out the wiring and the pump is getting power on all three legs but nothing. The pump failed with the press. sw. in the closed pos. But the overload didn't and does not open. I had changed out the control unit with a known good one and no help. Pumps don't last forever and I don't have the money to call Gardner to change it, and even though I know they would work with us, so I'm going to try to do it myself w/help. I watched/helped Gardner with a neighbors pump that had the wires chaffing against the metal casing and shorting intermittently. A gantry/hoist would sure be nice but I'm going to have to rig up something instead. I had "fiberglass" pipe sections used as well as composite casing when installed. Except for the last one of course. This video is a great help. Your "Pump Guy" seemed first rate with patience and experience knowledge. People like him don't get the respect they deserve but they know it. I would have liked to see or hear more clearly about how far from the bottom the pump was set at, how deep it was in the first place (I couldn't hear what was said), a closer view of the thing used to hold the pipe sections while dropping it in and a little more of the well cap that was used to suspend everything. Other than those things it is a good video, produced and explained well.
@AdamSahr-cj4kf
@AdamSahr-cj4kf 5 жыл бұрын
7 years is a damn good length of time...
@mitchdenner9743
@mitchdenner9743 5 жыл бұрын
@@AdamSahr-cj4kf not really, should get 20
@seidualisampare3373
@seidualisampare3373 4 жыл бұрын
@@AdamSahr-cj4kf you are advised to remove pump at least every 2 years for inspections and observations.
@ray_biker7406
@ray_biker7406 8 жыл бұрын
Engineer775, Thank you for the informative video. I also live in Upstate SC. Do you have any issues with water acidity? The biggest problem with our well water is low pH. I can only use plastic piping or stainless. Galvanized pipes and fittings don't last long and leach metals into the water
@engineer775
@engineer775 8 жыл бұрын
+Ray_Biker I don't have that problem. Just go with the PVC and you should be fine.
@josephsaucedo8691
@josephsaucedo8691 7 жыл бұрын
Yes pic deep set pipe sch 120 is best and ss nipples to use
@edbouhl3100
@edbouhl3100 4 жыл бұрын
Reverse problem here in the southwest with Colorado River water and alkalinity. Same result though, even with copper.
@mr.d3916
@mr.d3916 7 жыл бұрын
what is the size of the well? 4" or 6"
@emmyjohnson2993
@emmyjohnson2993 4 жыл бұрын
That's 5"
@TsetsiStoyanova
@TsetsiStoyanova 3 жыл бұрын
What exactly was the black expander that he attached to the pvc pipe? Are those pvc material white pipes or something else?
@Scentsational
@Scentsational 3 жыл бұрын
Threaded PVC pipe lengths, male 1 end, female the other... NOT glued connections! The black rubber diamond was a torque arrestor, to absorb any twisting of the pump on each startup. I prefer to use continuous length poly pipe coils though... No junctions to fail.
@danhunik7949
@danhunik7949 3 жыл бұрын
@@Scentsational The only problem with continuous poly pipe coils is that they are not strong enough to use in a really deep well. My well is 300 feet and I was told the poly pipe was not strong enough.
@wwreakin3085
@wwreakin3085 6 жыл бұрын
Why not use galvanized pipe?
@darrenlobow9384
@darrenlobow9384 7 жыл бұрын
I am having a problem with my bore well at home. It's a new bore that we have drilled to 500ft and sent a sub motor inside up to 480ft. We get a min water for house use only. Some times 20min in the morning. The water level is low at my site. But my problem is, the very 1st pipe that connects to my Submerge moto always gets bulged and burst in the middle of the pipe. What could be the reason? My bore technician also says that he has not come across this issue in his whole experience. This has happened 2 times now in 1 month itself.
@biire4u357
@biire4u357 6 жыл бұрын
Just going over a few of the technicals of your application, there is head water pressure of 0.43 psi per vertical foot. So a depth of 480 ft * 0.43psi = 206.4 psi static pressure (static pressure is water not moving and filling the vertical 480 ft pipe) I don't know the outlet size of your pipe, but a schedule 40 one inch diameter pipe maximum operating pressure is 270 psi. Your static load is 206.4 psi without the pump even engaged. Depending on the hp of your pump motor, the pump has to against a 206.4 psi load and then put enough energy into a 480 ft static column of water and get it moving. Also you have to add the additional load from the water holding pressure tank which might be 60- 100 psi just on its own. So with static pressure of 206.4 psi + pressure tank of 60 psi = 266.4 psi. So if your maximum operating pressure on a 1" line is 270 psi (a bigger diameter pipe is even lower, for example 1.5" = 198 psi ) you are just starting to move the water with an operating pressure that is 99% of maximum operating pressure and that is the static load only. And just like a industrial motor starting, you have to put in more energy to overcome the inertial mass of the motor and friction loads before you are up to running speed. That initial starting torque can be 200% more than the continuous running speed. In your case, trying to move a 480 ft column of water with pipe friction losses of 500Ft or more from your pump to your house into a 60 psi holding tank might put momentary pressures on that bottom pipe of 700 psi or more. Plus, the water itself gets heated up from all that pump work being done on moving that water, so the bottom of your well pipe schedule 40 pipe will be weaker from any temperature increase than the top of the well. Sorry for the long reply...but my hunch is you are operating well in excess of your maximum operating pressure and the plastic pipe is swelling from this excessive pressure. You need metal pipe in that bottom section to handle the pressures.
@darrenlobow9384
@darrenlobow9384 6 жыл бұрын
biire4u thanks for the reply. I dont mind putting a metal pipe, but if i do that, i am frightened that it might get rusty on a long run and must not cut so that the pump will fall off or get caught inside the bore well. Is there anything else that you might suggest?
@Ayvengo21
@Ayvengo21 3 жыл бұрын
Where i could by that black thing that keep pumt still?
@mattwoody1089
@mattwoody1089 4 жыл бұрын
Hi how big was the white pipe matt
@WillKlaver
@WillKlaver 6 жыл бұрын
.. where's your Rope on the pump in case the Pipe breaks & you gotta pull it out of the well..?
@smartyjones7459
@smartyjones7459 4 жыл бұрын
also there should be wire guides every 15 feet...
@romdos11
@romdos11 8 жыл бұрын
I don't see any replies by engineer775, but I will try. Where does the simple pump connect? Into the tee through one of those braided hoses?
@caseywillie443
@caseywillie443 8 жыл бұрын
+romdos11 Nah the simple pump is a deep well hand pump with a piston cylinder in the water. You drive it with the long handle above ground through a rod that connects in a supply line down in the water. The Braided line that's connected is a bypass, when out of power you could open a faucet in the house and pump water from the simple pump.
@ofershaked1448
@ofershaked1448 9 жыл бұрын
Do u work in ny as well ?
@LynnStone
@LynnStone 8 жыл бұрын
Dude you skipped all the details at the end! Loved it other wise.
@ruskybuster1407
@ruskybuster1407 7 жыл бұрын
Where is the safety rope?
@madKashif-sr3wg
@madKashif-sr3wg 5 жыл бұрын
Dear Sir my submersile pump embog in borehole in soil borehole is 160 ft and pump hang on 150 ft how can we pull out pump safely from borehole without any damage
@smartyjones7459
@smartyjones7459 4 жыл бұрын
call a licensed plumber that works on well systems...
@earlpowlett2831
@earlpowlett2831 3 жыл бұрын
Can I get in touch with the pipe installer. I would like to purchase a 2 hp motor or mother and pump.
@dennisthemenance5433
@dennisthemenance5433 7 жыл бұрын
For Preventive Failure? What is the Average Life of a Well Pump? So we can Start Saving $ ahead of time and Plan to R&R it BEFORE it fails? Thank you.
@markwilliams4525
@markwilliams4525 3 жыл бұрын
I've seen them last anywhere from 6months to 50 years depending on how they were treated. Tank being properly sized, tank having the right amount of air whether it's a diaphragm, bladder or standard tank. But average life span is around 12 years
@kidsarcaderoom7316
@kidsarcaderoom7316 6 жыл бұрын
Cool video
@CSJiGSaW08
@CSJiGSaW08 6 жыл бұрын
What is the rubber guide piece? Where can I get one?
@danstrayer111
@danstrayer111 6 жыл бұрын
that is a torque arrestor
@karenmmcthree
@karenmmcthree 5 жыл бұрын
Where can you get one of the hand pumps for a well already in place?
@abdibr11
@abdibr11 8 жыл бұрын
Great Video, can the pump be used in Africa or it's only for 110v ?
@cheskybaba4864
@cheskybaba4864 8 жыл бұрын
+Abdul Ibrahim Check what your electric requirements are 110/220 and you will be able to get what you need.
@jpoil55
@jpoil55 7 жыл бұрын
Does the meter work on oil wells like stripper wells? Just curious
@jpoil55
@jpoil55 7 жыл бұрын
The meter you used in the beginning of the video
@kennykemp2790
@kennykemp2790 6 жыл бұрын
They do have distance limitations depending on the model. They can also have some interference issues depending on the pipe/casing used in the hole. The only other thing I don't know is if they would need calibrated to go through gas instead of air. I don't know if sound travels the same in both. I would talk to a dealer to find out more if you're interested.
@dutchofsc
@dutchofsc 9 жыл бұрын
Who is the well guy? I'm looking for a good well company in our area.
@michaelapostol8250
@michaelapostol8250 5 ай бұрын
What is the size of the casing sir?
@mikesmith3933
@mikesmith3933 6 жыл бұрын
How much pipe u put in
@navarrekinsaw752
@navarrekinsaw752 10 жыл бұрын
Thanks Eng
@jesseweaver8899
@jesseweaver8899 3 жыл бұрын
I just don't understand why they don't use black poly well pipe, seemless, won't break!
@safffff1000
@safffff1000 3 жыл бұрын
I agree, seems it's easier to take out also
Самый Молодой Актёр Без Оскара 😂
00:13
Глеб Рандалайнен
Рет қаралды 12 МЛН
Playing hide and seek with my dog 🐶
00:25
Zach King
Рет қаралды 34 МЛН
Deep Submersible Well Pump Installation. Educational Guide
41:08
H2o Mechanic
Рет қаралды 432 М.
How do Submersible pumps work?
3:49
Lesics
Рет қаралды 4,1 МЛН
Water Well Drop Pipe Selection Guide
12:39
R.C. Worst & Co., Inc.
Рет қаралды 208 М.
What Size Well Pump Do You Need? How to install a Pump Correctly
12:07
SunPumps SDS Install
17:11
SunPumps
Рет қаралды 4,6 МЛН
2 Wire Vs  3 Wire Well Pump Motors
10:08
R.C. Worst & Co., Inc.
Рет қаралды 267 М.
HOW TO REPLACE A SUBMERSIBLE WELL PUMP.  STEP BY STEP
21:29
Alex The Handyman
Рет қаралды 24 М.
Submersible Pump - Stuck in the Well - 3 Ways it can Happen!
15:35
Clear Water Pump & Well LLC.
Рет қаралды 206 М.