السلام عليكم بجي عطل 35 ازاي ترتيب مفناطيسات البير ؟
@MasudOfficialkwt Жыл бұрын
Err 35 occurred before the run contactor pick-up 1 .check whether the 1st down forced deceleration is valid 2 .F4-01=1 3 .whether the inspection switch on the inspection state and able to done the inspection run 4 .F0-00=1 Err 35 occurred as soon as the run contactor pick-up 1 .check whether the inspection switch on the inspection state Err 35 occurred during running 1 .check whether running overtime, , run over the time of Err 35 occurred when meet the 1st levelling position 1 .Whether the F4-03 INCREASE WHEN UP, DECREASE WHEN DOEN, switch the main board PGA and PGB if it is not . 2 .Level sensor N .O, N .C .setting error . 3 .level sensor signal flash, check the plate Err 35 during running: 1 .check whether run overtime of F9-02 setting value, and no receiving of levelling signal 2 .the floor distance less than 50cm, check the sensor 3 .the F6-00 setting too small Run to the top floor: 1 .the 1st forced slowdown is valid and juadge on the door-area, check whether the learned floor amount are same as the setting of F6-00 and F6-01 . 2 .Error occurs if the lifting height less than 50cm Err35 occures when power-on Check whether the plate length is 0 after power-on
@sergeim50092 жыл бұрын
Help nice 3000 error 40 what to do?
@MasudOfficialkwt2 жыл бұрын
sub code?
@tauhidalislam37993 жыл бұрын
Please talk and explain. Sir
@MasudOfficialkwt3 жыл бұрын
what's you need to know telling me
@tauhidalislam37992 жыл бұрын
I want to know how to start inspection run and control wring.? Please explain step by step.sir.
@tauhidalislam37992 жыл бұрын
Gearless and geared.
@MasudOfficialkwt2 жыл бұрын
Group F0: Basic parameters F0-00 Control mode 0: Sensorless vector control (SVC) 1: Closed-loop vector control (CLVC) 2: Voltage/Frequency (V/F) control 1 - ★ 192 F0-01 Command source selection 0: Operation panel control 1: Distance control 1 - ★ 192 F0-02 Running speed under operation panel control 0.050 to F0-04 0.050 m/s ☆ 193 F0-03 Maximum running speed 0.250 to F0-04 1.600 m/s ★ 193 F0-04 Rated elevator speed 0.250-4.000 1.600 m/s ★ 193 F0-05 Rated elevator load 300-9999 1000 kg ★ 194 F0-06 Maximum frequency 20.00-99.00 50.00 Hz ★ 194 F0-07 Carrier frequency 0.5-16.0 6.0 kHz ★ 194 Group F1: Motor parameters F1-00 Encoder type 0: SIN/COS encoder 1: UVW encoder 2: ABZ incremental encoder 3: ECN413/1313 absolute encoder 0 - ★ 195 F1-01 Rated motor power 0.7-75.0 Model dependent kW ★ 195 F1-02 Rated motor voltage 0-600 Model dependent V ★ 195 F1-03 Rated motor current 0.00-655.00 Model dependent A ★ 195 F1-04 Rated motor frequency 0.00-99.00 Model dependent Hz ★ 195 F1-05 Rated motor speed 0-3000 Model dependent RPM ★ 195 F1-06 Encoder initial angle (synchronous motor) 0.0-359.9 0 Degree (°) ★ 196 F1-07 Encoder angle at power-off (synchronous motor) 0.0-359.9 0 Degree (°) ★ 196 F1-08 Synchronous motor wiring mode 0-15
@tauhidalislam3799 Жыл бұрын
Saalam aliykum sir, thanks. Plz make video all errors solution with your voice.
@basitghayas1644 Жыл бұрын
How to remove Error 35 during shaft learning please tell me?
@MasudOfficialkwt Жыл бұрын
Err 35 occurred before the run contactor pick-up 1 .check whether the 1st down forced deceleration is valid 2 .F4-01=1 3 .whether the inspection switch on the inspection state and able to done the inspection run 4 .F0-00=1 Err 35 occurred as soon as the run contactor pick-up 1 .check whether the inspection switch on the inspection state Err 35 occurred during running 1 .check whether running overtime, , run over the time of Err 35 occurred when meet the 1st levelling position 1 .Whether the F4-03 INCREASE WHEN UP, DECREASE WHEN DOEN, switch the main board PGA and PGB if it is not . 2 .Level sensor N .O, N .C .setting error . 3 .level sensor signal flash, check the plate Err 35 during running: 1 .check whether run overtime of F9-02 setting value, and no receiving of levelling signal 2 .the floor distance less than 50cm, check the sensor 3 .the F6-00 setting too small Run to the top floor: 1 .the 1st forced slowdown is valid and juadge on the door-area, check whether the learned floor amount are same as the setting of F6-00 and F6-01 . 2 .Error occurs if the lifting height less than 50cm Err35 occures when power-on Check whether the plate length is 0 after power-on