স্যার আপনি নাইচ কন্ট্রোল নিয়ে যাবতীয় সব কিছু তুলে ধরেন অনেক জানার আছে।
@engmohamedawad80903 жыл бұрын
Hi sir bro how are you can you send to me your WhatsApps number please
@Elevator-Solutions3 жыл бұрын
+8801518328474
@rahan5734 жыл бұрын
That installation is nice, The motor is normally meant to be used as a MRL but it's good in a motor room too infact, it's more solid in a motor room and the logic works good too. P.s nice English
@rummyraedezoysa70003 жыл бұрын
please explain how to adjust the lift cabin leveling by key pad NICE 3000 module thank you.
@renebragat12893 жыл бұрын
Please help me,why is it that brake contactor won't energized during automatic operation
@renebragat12893 жыл бұрын
During automatic operation ws and fx contactor will pick up except the BY contactor won't energized,pls tell what is locking of what I'm doing,tnx
@elangosilambarasan30385 жыл бұрын
Hello enyone help me. I have double side open G+2 lift. all the time lift reaches ground floor rear side door open close function not happen. but lift comes to top floor rear Side door open close function happen but there is no need for rear side open at top floor. In my site ground floor only double side other floor single side only. So now what can I do. Which parameter I have to adjust
@AliRaza-vv3ju3 жыл бұрын
Check parameters group Fb.
@edsonsilva-rx1dt5 жыл бұрын
Good afternoon friend! I have a problem with such equipment. when I make the high adjustment it when it finishes the Cirilo of fire appears and goes to the ground floor I already checked the keys in the buttonhole and the button inside the cabin. can you help me?
@Engr.Aminul5 жыл бұрын
edson silva check the fire programming. F5 menu It's may be f5-08 value 11 Make it 0 and checking. If done then confirm wireing and re programming.
@AliRaza-vv3ju3 жыл бұрын
Check group F5 parameters.if any 11 r 43 then set to 0. R 23/55 then also set to 0.
@samuelnadar3963 жыл бұрын
Hi sir, how we know used watts
@sergiosilvademourasergin71723 жыл бұрын
Good morning, automatic reset for error 20-009, is there this function?
@mohammadnaseerhossain25972 жыл бұрын
কেমন আছেন sir, আমি ডোবাই থেকে দেখছি sir, আমার জন্য একটা গ্ৰোপ কন্ট্রোলের ভিডিও বানান দয়াকরে NIC3000new
@sahulmj41113 жыл бұрын
Hi sir can you helf me motor tuning time F3 brecker tripping pls give me a solution.
@sahulmj41113 жыл бұрын
Nice 3000 controller
@samsulalambd2 жыл бұрын
good
@jhonc_c80255 жыл бұрын
Hello Do they have information about the reopening of double entry cabins ..? I would thank you a lot
@Engr.Aminul5 жыл бұрын
Sure. I will give a video. Thanks for comments.
@Engr.Aminul5 жыл бұрын
I uploaded a video you can check it.
@jhonc_c80255 жыл бұрын
@@Engr.Aminul I have reviewed it, thanks for the information ... my problem is that my elevator opens and circles the doors correctly. but I have a door that opens on a single floor and when the elevator is on that floor and I pulse the hall call of the same floor the door does not reopen .. this happens only on this floor .. since the other door does work properly in the other floors ... I have configured according to the information provided FB-00 = 2, FB-02 = 65534, FB-04 = 00001
@Engr.Aminul5 жыл бұрын
Simple matter. Fb-02 for front door fb-04 for rear door. Both door built-in value 65535 Binary value of 16 floor 1111111111111111=65535 When you off any floor Deduct it's binary value. Example 2 nd floor off 1111111111111101=65533 1st and second floor off 1111111111111100=65532 Floor start from right side
@jhonc_c80255 жыл бұрын
@@Engr.Aminul I understand, the parameters are already configured correctly for the doors openings in selected floors, the problem is in the reopening of the 2nd door, in which it does not reopen with the hall call. Maybe you have information about the reopening of doors .. !!
@rhhridoybd713 жыл бұрын
Thanks ☺️
@sampathprabhakar60184 жыл бұрын
i am getting Error 36 time and again, when checked the contact feedback is fine and no issue , but the error is displayed
@Engr.Aminul4 жыл бұрын
Ckeck : 1. Power supply 24 v 2. Break power 3. Break feedback
@AliRaza-vv3ju3 жыл бұрын
Check run contactor coil is normal.Safety line voltage is too low.
@sahulmj41113 жыл бұрын
hi sir can you helf me nice 3000 controller shaft tune OK after car call not received . pls helf me.
@doelthangmay49923 жыл бұрын
how is this motor brand name
@sirajzaidi79463 жыл бұрын
what is protocol?
@manuelfeliciano195 жыл бұрын
how to solve error 28 on a monarch drive?
@AliRaza-vv3ju3 жыл бұрын
Check parameters group F5.if any 68/100 Then check no r nc. R set to 0 for disconnect.
@mudthermahmoud15505 жыл бұрын
can you help me to get the electrical diagram of it?
@Engr.Aminul5 жыл бұрын
send your mail address
@Engr.Aminul5 жыл бұрын
Sharpliftsbd@gmail.com
@sanidpalemad66284 жыл бұрын
Please tell me how to solve error 20&33
@Engr.Aminul4 жыл бұрын
e-20- break encoder power fault
@vicentmushi99063 жыл бұрын
how to solve E20-009 ????
@Services19964 жыл бұрын
Sir your video is so good but your voice is low sir pls raise your voice volume
@Engr.Aminul4 жыл бұрын
Its the first video. next will be implement...
@albertobravo57655 жыл бұрын
Hi everybody. Please where I can enter the fire signal from a Fire Detection Panel (dry contact) to make the lift goes to base floor, open the doors to evacuate the people and then disable the lift until the fire alarm is over. I hope someone can help me
@isaiahkhomotso12954 жыл бұрын
Good day all Is the monarch ME320LNNew integrated?
@isaiahkhomotso12954 жыл бұрын
Good day All Is the monarch ME320LNNew integrated drive.
@AliRaza-vv3ju3 жыл бұрын
F5 group you can choose a free port and set 11/43 with respect to no/nc.
@kengyreateguivalles90224 жыл бұрын
Clases online para programar?
@Engr.Aminul4 жыл бұрын
run contactor feed back problem. check point 1. 24v power supply 2. x6 led on or not 3.run contactor coil ok or not? 4. run contactor mechanically jam or not? etc....
@user-hx2me8bg8e4 жыл бұрын
I am from Algeria. i need PCB monarch nice 3000 but I don't know where.also I need tool test.?? can you help me??
@Engr.Aminul4 жыл бұрын
Welcome. You send me inverter model.
@nabeelsardar26544 жыл бұрын
290 volt gearless motor
@mahfoojalamkaushambi11594 жыл бұрын
Error 72
@goseeelevatorsupplyinstall93785 жыл бұрын
how to fix the error 35 on a monarch drive?
@vinhoan10515 жыл бұрын
hey man. you can check circuit shorcut. board communication. ss1 ss2 sl or ss3.
@Engr.Aminul4 жыл бұрын
Need shaft learn to remove it.
@AliRaza-vv3ju3 жыл бұрын
Automatically remove when shaft learning is complete.
@salauddin9953 жыл бұрын
Good evening sir .I how to solve monarch error 84 please can explain
@Engr.Aminul3 жыл бұрын
Apply e65 fault solution
@nelsonhenrique29565 жыл бұрын
Boa noite, como mudar a linguagem do voicer para Porturgues Brasil
@Engr.Aminul5 жыл бұрын
Pls comments in English language
@nasimamojib72013 жыл бұрын
স্যার আপনার সাথে জোগজোগ করতে চাই।।নাম্বার টা দেন।।
@Engr.Aminul3 жыл бұрын
01821831888
@vivapalestine90634 жыл бұрын
Error 40 how can I solve sir ?
@smrafiqulislamrafiq93422 жыл бұрын
How to solve Err66 &65
@vicentmushi99063 жыл бұрын
E30-103
@jgdev29664 жыл бұрын
How to solve err 53 and 51 ? Pls advise ..thanks
@Engr.Aminul4 жыл бұрын
53 fault 1. door inverter switch off 2. door limit not ok 3. door open close not ok 4. door contact short Error 51 can communication fault serial card / ctb board not connect with motherboard
@jgdev29664 жыл бұрын
@@Engr.Aminul thanks brother..can i have yr watsapp num brother ?? Please 😊
@Engr.Aminul4 жыл бұрын
@@jgdev2966 +8801821831888
@jgdev29664 жыл бұрын
@@Engr.Aminul thanks brother..p👍👌
@sheikh.Sadi9080 Жыл бұрын
@@Engr.Aminul is that your name..?
@sirajzaidi79463 жыл бұрын
hi
@derickamiani86344 жыл бұрын
How to solve error 34, nice 3000 drive
@Engr.Aminul4 жыл бұрын
Logic fault. need to replace board
@aleemuddin61763 жыл бұрын
hello dears we need complete all error list and trouble shooting details vedio.
@Engr.Aminul3 жыл бұрын
Ok
@freefavor7865 жыл бұрын
plz need full programing video
@Engr.Aminul5 жыл бұрын
its only basic information. If need any special document pls mention. mail me aminul963@gmail.com
@freefavor7865 жыл бұрын
bojlam naa vaiya
@anawir94614 жыл бұрын
How to fix error E.34 on a monarch drive?
@Engr.Aminul4 жыл бұрын
Motherboard fault
@anawir94614 жыл бұрын
Thank's, About the solution..?
@AliRaza-vv3ju3 жыл бұрын
Replace motherboard.
@nabeelsardar26545 жыл бұрын
Error 36 is coming how to set this one.
@elevatormechanicbd90574 жыл бұрын
Check the run contactor feedback
@AliRaza-vv3ju3 жыл бұрын
Check run contactor feedback and safety line voltage.
@shaonislam16105 жыл бұрын
nice 3000 fault E 37
@Engr.Aminul5 жыл бұрын
1. Check break it's open/not 2. Check break voltage 3. Check break magnetic contact feedback 4. Check power supply 24v 5. Check transformer
@sayangkamu954 жыл бұрын
@@Engr.Aminul tuiii
@a.mzubair78925 жыл бұрын
Error 65, in nice 3000 controller, this lift 2 to 4 day good running again get problem like lift hang that is big problem it happens regulary please give me a solution, many engineer seen that they work but 2 day after same problem come, please help me, give a permanent solution idea
@Engr.Aminul5 жыл бұрын
send your mobile no ? I Know you very well.
@a.mzubair78925 жыл бұрын
01673992184 this is my number , first of all send me an sms
@HassanHassan-uq3fd5 жыл бұрын
A.M Zubair Hi
@a.mzubair78925 жыл бұрын
Give your number
@rameezhassan2324 жыл бұрын
I have error49 and error66 how its is solve please tell me
@amadouassane98584 жыл бұрын
mon ascenseur SIGLEN ne bouge pas avec la programmation MONARCH NICE 3000 AIDE MOIS EN LANGUE FRANCAISE
@AliRaza-vv3ju3 жыл бұрын
Check Fb-09 parameter set to 0. CTB output and door lock and limit signals.
@zaidshaikh82144 жыл бұрын
How to fix error 34
@AliRaza-vv3ju3 жыл бұрын
Replace motherboard
@kengyreateguivalles90224 жыл бұрын
Error Code E36?
@AliRaza-vv3ju3 жыл бұрын
Check run contactor feedback and safety line voltage.
@bestallah92544 жыл бұрын
All part parts changed makings auto tune error code 20 coming
@AliRaza-vv3ju3 жыл бұрын
Encoder fault Reset on default parameters. And Autotune with respect to nameplate of motor.
@dselevator23494 жыл бұрын
Can you help for the control nice 3000 error 16?
@Engr.Aminul4 жыл бұрын
phase miss of motor to inverter
@dselevator23494 жыл бұрын
@@Engr.Aminul How to handle it how?
@Engr.Aminul4 жыл бұрын
@@dselevator2349 check the connection between motor and controller u v w
@matritsakiany62592 жыл бұрын
Error 88?
@easaelevatorelictcal30382 жыл бұрын
116 error problem
@aisyahbahrin71264 жыл бұрын
How to solve problem error 41?
@Engr.Aminul4 жыл бұрын
power / safety fault
@AliRaza-vv3ju3 жыл бұрын
Power/safety fault r safety circuit feedback.
@masterliftspakistan65595 жыл бұрын
Can u help me to unblock password in monarch 3000 controller???
@Engr.Aminul5 жыл бұрын
its not possible.
@vicentmushi99065 жыл бұрын
hello Imran please check me here vmushi88@gmail.com
@vicentmushi99065 жыл бұрын
Sharp Lifts & Engineering hello sir please I need your email or any contact kindly send me through this email vmushi88@gmail.com
@stevenjuliando54304 жыл бұрын
How to solve Error Code 41 ? Please give me some help brother 🙏
@Engr.Aminul4 жыл бұрын
Error 41 1. power supply three phase, 24v 2. Safety problem 3. safety program for new lift when use x25, As safety x26, x27 door contact then program f5-36-4 f5-37-5 f5-38-5
@stevenjuliando54304 жыл бұрын
@@Engr.Aminul thank you brother. Youre the best👍
@TRaja-uf7fv3 жыл бұрын
How to solve landing call not register
@oscarechavarria71954 жыл бұрын
How to solve E63?
@Engr.Aminul4 жыл бұрын
63, 65, 68 same
@AliRaza-vv3ju3 жыл бұрын
Change the eight and ninth to "1" in F8-19.
@imamalhasan21484 жыл бұрын
how to restart nice 3000+ motherboard plz help
@Engr.Aminul4 жыл бұрын
+8801710625170
@atikalove94 жыл бұрын
@@Engr.Aminul I need to call you.. I have a monarch n300+ system. The control board is missing
@atikalove94 жыл бұрын
@@Engr.Aminul the number is not correct
@Engr.Aminul4 жыл бұрын
@@atikalove9 check again +8801710625170 +8801711428593
@sadytheboom88974 жыл бұрын
Sir How to Solve Nice Three Thousand Erro 03/04
@Engr.Aminul4 жыл бұрын
Overcurrent fault check below 1. Encoder 2. Motor check 3. Inverter output short circuit 4. Autotune fault. etc