How to put inhibitor into your central heating system using a towel rail.

  Рет қаралды 43,994

dereton33

dereton33

Күн бұрын

If your system needs a cleanser run through it, or fresh inhibitor, here is how to easily do it using a towel radiator.
Visit Al`s plumbing shop for parts at www.amazon.co.uk/shop/dereton33
Saved some money on plumbers fees? Use the THANKS button.
Or through Paypal using my site link www.dereton33.com/page118.html
Many thanks Al.

Пікірлер: 82
@garyhodge7861
@garyhodge7861 3 жыл бұрын
Thanks Al, that's embarrassingly simple! I've always had a tank in the loft but my new home has a combi and I was scratching my head trying to work out where to put the cleaner.
@dereton33
@dereton33 3 жыл бұрын
Glad to help
@cliffcarlo180
@cliffcarlo180 3 жыл бұрын
Grate tip and advice as usual Al 👍
@dereton33
@dereton33 3 жыл бұрын
Thanks 👍 Cliff.
@iloveyoueggegg
@iloveyoueggegg Жыл бұрын
Thank you! This video saved me a tenner and buying stuff that I was only gonna use one
@dereton33
@dereton33 Жыл бұрын
Great to hear!
@omarsh82
@omarsh82 3 жыл бұрын
Love this channel. Much appreciated.
@dereton33
@dereton33 3 жыл бұрын
Glad you enjoy it!
@mda5003
@mda5003 3 жыл бұрын
I have a sealed system and did that with my bathroom towel radiator but having poured in all the inhibitor I filled the empty container with water and poured that in until it reached the very top. Quicker to re-pressurise and of course I swilled out the very last drop of inhibitor.
@dereton33
@dereton33 3 жыл бұрын
Great tip thanks.
@joehaverty5201
@joehaverty5201 3 жыл бұрын
Super video, thanks, really helped
@dereton33
@dereton33 3 жыл бұрын
You're welcome!
@damianmarote6374
@damianmarote6374 2 жыл бұрын
Like the painting of bude!
@dereton33
@dereton33 2 жыл бұрын
It is actually a picture I took.
@waynewinky2754
@waynewinky2754 Жыл бұрын
Careful with new modern TRV's on towel rads, even when closed to their OFF setting (frost symbol) they don't shut the water off to the radiator as they dont push the little pin in the TRV carcass all the way that stops the water so there's pressure continually getting into the radiator. Always best with the new TRV's to unscrew the securing ring to release and take off the thermostatic head from the TRV base, find or borrow the plastic blanking cap that came with the unit, and screw that on firmly in it's place so it pushes the pin and stops the water/pressure. Then after checking the other side valve is fully closed, then the towel rad can be bled with a bleed key and top sealed nuts loosened.
@dereton33
@dereton33 Жыл бұрын
Thanks for the tip Wayne.
@tedgrant2
@tedgrant2 2 жыл бұрын
I found an angled pipe fitting in my garage, which had the same thread as the plug hole. I used some putty on the thread to prevent any spills, which got pushed to the thread end. The open end of the pipe fitting, pointing upwards, was higher than the water level in the radiator. I used a small funnel to pour in the inhibitor, followed by some clean water to rinse. Easy !
@dereton33
@dereton33 2 жыл бұрын
Well done.
@tedgrant2
@tedgrant2 2 жыл бұрын
@@dereton33 And no leaks !
@kingofthetrowel1725
@kingofthetrowel1725 3 жыл бұрын
Nice one al 👍👍
@dereton33
@dereton33 3 жыл бұрын
Thanks 👍
@chazbalsdon5309
@chazbalsdon5309 3 жыл бұрын
Lovely picture of Bude behind you Al!
@dereton33
@dereton33 3 жыл бұрын
Yes one of our favourite places.
@evieemaya88
@evieemaya88 2 жыл бұрын
Another top vid!!! Inhibitor is something that's meant to be added approx every two years i understand. Can you simply do this every two years or do you have to start worrying about dilution rates after the first time of doing this? As I assume if u don't fully flush the system down there will still be some "older" inhibitor in the system?
@dereton33
@dereton33 2 жыл бұрын
Yes it is best to drain and flush everything out before adding fresh inhibitor.
@ww4407
@ww4407 Жыл бұрын
Great video. Is it best practice to open all the lockshield and TRV valves when adding a cleaning solution like Fernox F3 to a f&e system? I assume this would help all the sludge to pass through the system?
@dereton33
@dereton33 Жыл бұрын
Yes, absolutely
@kevincraney9879
@kevincraney9879 2 жыл бұрын
Is this the same for leak sealant. I've tried twice on with fernox and sentinel express systems and it never worked. So I'm going to try the liquid version and this seems quite straightforward
@dereton33
@dereton33 2 жыл бұрын
Yes it is the same Kev.
@Spankplanker
@Spankplanker 3 жыл бұрын
Excellent, thanks! Incidentally, are you from the same part of the world as Stanley Unwin? I think you sound a lot like him, (except I can understand you a bit better!)
@dereton33
@dereton33 3 жыл бұрын
Now there`s a good man.
@TheSlickwilli
@TheSlickwilli 2 ай бұрын
Hi Al, how do you wanna do the bottom? Where does the water go? How do you collect the water? How do you connect it all up how much of it do you take out my radiator goes right to the floor does this mean I have to take the radiator off how do you do that great video if you’re a plumber
@dereton33
@dereton33 2 ай бұрын
Try watching the video again.
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
👍👍👍AL
@dereton33
@dereton33 3 жыл бұрын
Thanks Paul.
@ImNotADeeJay
@ImNotADeeJay 3 жыл бұрын
my heating system has a shut valve that flushes directly to the sewer system... should I drain my heating system using this valve or the way you described in the video is better? thanks
@dereton33
@dereton33 3 жыл бұрын
That will empty quicker with less mess too.
@ImNotADeeJay
@ImNotADeeJay 3 жыл бұрын
@@dereton33 thanks
@islarodrigues1476
@islarodrigues1476 2 жыл бұрын
Dear Al, if I want to add Inhibitor myself, but don't want to drain the system again (and risk more air getting in!! :( ) but don't have a towel rail (open, F & E, condensing boiler system), is it possible to do it via another radiator? Which would be the best one? Do you have a video for this? Thank you as always for all your help, Isla
@dereton33
@dereton33 2 жыл бұрын
I have a video on how to do it through a radiator. The upstairs ones are best to use.
@islarodrigues1476
@islarodrigues1476 2 жыл бұрын
@@dereton33 Thank you Al :) That's the video I was looking for but couldn't find. It's knowing how to drain the radiator (top ones don't have a drain tap) and fill - it would be easiest for me to do it via the bleed valve...if you know the link to the best video, that would be great, Isla
@ericthekingthekingtheking4842
@ericthekingthekingtheking4842 5 ай бұрын
hello mate couple of questions how much inhibitor do you put in qnd also your not turning the main water off just the shut off and trv at the towel rail 👍
@dereton33
@dereton33 5 ай бұрын
If you are filling the system from fresh then the whole bottle. If you just turn off the TRV and lockshield valve, then empty the water out of the rad you should have enough space for the inhibitor. If not, then leave the valves on and drain some water out via the drain cock. You will not need to turn the water off if you have a combi boiler, but you will if you have an F and E system.
@bilalraja6745
@bilalraja6745 6 ай бұрын
Make sure your radiators are cold when adding any chemicals into the system as you don't want to burn yourself
@dereton33
@dereton33 6 ай бұрын
Thanks.
@michaeldevlin2685
@michaeldevlin2685 3 жыл бұрын
Could you answer this quesion for me please ? I really liked the tutorial about introducing inhibitor into the central heating system through a radiator. My question is : Would it be possible just to use a syphon to drain off 500 to 100cls? Silverline do a syphon that looks ideal. Thanks for your interesting videos.
@dereton33
@dereton33 3 жыл бұрын
Yes that would be fine.
@michaeldevlin2685
@michaeldevlin2685 3 жыл бұрын
Sorry I wasn't too clear with my initial question. What I really meant was : Once that about a litre of water has been syphoned out of the radiator using the Silverline syphon. The Fernox could added to the system. I'm just curios to know if the syphon method would work.
@simonpage6549
@simonpage6549 3 жыл бұрын
Will this get rid of sludge that could be causing overflow from the f and e tank?
@dereton33
@dereton33 3 жыл бұрын
Best to use system cleaner first.
@simonpage6549
@simonpage6549 3 жыл бұрын
@@dereton33 ok...how do I do that? (Thanks!)
@barnbersonol
@barnbersonol 10 ай бұрын
The very first time i fitted rad I had the presence of mind to fit a valve with a drain tail. It happened to be right next to the back door too so I can drain the whole system easy peasy. Why isn't that standard practice?
@dereton33
@dereton33 10 ай бұрын
Nothing is standard in plumbing
@nsoper19
@nsoper19 2 жыл бұрын
My towel radiator is on the hot water circuit and not the heating circuit (regular system boiler). Will this method still work OK?
@dereton33
@dereton33 2 жыл бұрын
Yes it will
@ericward2260
@ericward2260 2 жыл бұрын
Dont think this should be done as the hotwater is what you use for pot washing ,and you dont want that it will make you sick.
@nsoper19
@nsoper19 2 жыл бұрын
@@ericward2260 it's just on the heating circuit for the hw, not heated with water from the tank. Still an odd setup though
@clairemc2256
@clairemc2256 3 жыл бұрын
How often do u need to add inhibitor ...don't think we've done ours for 10 years. Is that bad? 🙈
@dereton33
@dereton33 3 жыл бұрын
5 is best.
@Mr_Wanderlust1
@Mr_Wanderlust1 Жыл бұрын
Can i do the same and it will go to all my other radiators around the house ? Shall I switch boiler off when doing this ?
@dereton33
@dereton33 Жыл бұрын
You can but switch off heating before doing it.
@Mr_Wanderlust1
@Mr_Wanderlust1 Жыл бұрын
@dereton33 do I need a gas engineer to do this job as he's trying to charge me £80.00 to put the fluid in one radiator a litre and it will go around the whole system. He claims it will be £80 as its a 1 hr job. Don't seem like it. I can close one radiator take some water out and then after fluid is in check if the pressure is at 1.5 as that's where it said be around without heating on
@Mr_Wanderlust1
@Mr_Wanderlust1 Жыл бұрын
@@dereton33 do I need to switch boiler off
@kimfowler5997
@kimfowler5997 6 ай бұрын
Hi. I have a Gibraltar towel rail in my bathroom. I’d like to know what way do I turn the tap handle to turn radiator off
@dereton33
@dereton33 6 ай бұрын
Clockwise.
@kimfowler5997
@kimfowler5997 6 ай бұрын
@@dereton33 Had 2 new radiators fitted yesterday. I don’t seem to have much luck with plumbers. He was good but fiddled me out of lots of money. He said he put inhibitor in my towel rail. I don’t think he did and let him know that. So now I’m going to have to get another plumber ☹️
@kimfowler5997
@kimfowler5997 6 ай бұрын
Also. Last guy a few yrs ago avoided my towel rail and used radiator in loft
@kristofdecupere4994
@kristofdecupere4994 2 жыл бұрын
Can you add some inhibitor without draining the heating system?
@dereton33
@dereton33 2 жыл бұрын
Yes if you just drain one rad out.
@DJBarnes1302
@DJBarnes1302 Жыл бұрын
Did this this afternoon, now my towel rail doesn’t work at all 😂 all other 7 radiators work fine though.
@dereton33
@dereton33 Жыл бұрын
Must have air in it or the valves are not turned on properly.
@grimegarage09isplop
@grimegarage09isplop 3 жыл бұрын
@Dereton33 I am going to post a comment on 1 of your videos from 7 years ago about compression fittings and pointing compound. I would leave the comment here but it may confuse some viewers. I just posted here so you would be aware of my intentions, I would like to know your opinion on a particular problem. Thanks.
@dereton33
@dereton33 3 жыл бұрын
Go ahead.
@martinleafe5688
@martinleafe5688 Жыл бұрын
Can i add inhibitor and leakage sealer at the same time ?
@dereton33
@dereton33 Жыл бұрын
No give them a gap of about a month.
@martinleafe5688
@martinleafe5688 Жыл бұрын
@@dereton33 right , nice one. Thanks for the reply 👍🏻👍🏻
@sean550
@sean550 Жыл бұрын
If you have a drain value downstairs why not just drain a little from upstairs .open air vent value and pour it in thier ,instead of opening valve in bottom.
@dereton33
@dereton33 Жыл бұрын
It really is up to what systems and ways that you like to do it.
@jamescrowther1234
@jamescrowther1234 3 жыл бұрын
Just for a layman, why would a central heating system need cleaning?
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
Corrosion black sludge (ferrous oxide)
@dereton33
@dereton33 3 жыл бұрын
Thanks Paul.
@paul_my_plumbs_uk
@paul_my_plumbs_uk 3 жыл бұрын
@@dereton33 i just started learning central heating at college 😃😃 in the geel squad
HOW TO DRAIN YOUR HEATING SYSTEM - Pressurised - PLUMBING TIPS
15:26
Best KFC Homemade For My Son #cooking #shorts
00:58
BANKII
Рет қаралды 69 МЛН
ЧУТЬ НЕ УТОНУЛ #shorts
00:27
Паша Осадчий
Рет қаралды 10 МЛН
Пранк пошел не по плану…🥲
00:59
Саша Квашеная
Рет қаралды 6 МЛН
How to put inhibitor in a central heating system
5:01
Noncey Builder
Рет қаралды 13 М.
How to Repair a Motorised Central Heating Valve
12:01
Skill Builder
Рет қаралды 461 М.
How to drain a central heating system
10:11
dereton33
Рет қаралды 75 М.
HOW TO DRAIN DOWN HEATING SYSTEMS - GRAVITY FED - Plumbing Tips
6:12
How to Remove and Refit a Towel Rail Radiator - Complete Tutorial
12:35
Justin Bailly JBTV
Рет қаралды 74 М.
How to drain down a central heating system | chemical flush | add inhibitor
10:13
哈哈这些娃娃可烦人了!#火影忍者 #佐助 #家庭
0:31
火影忍者一家
Рет қаралды 33 МЛН
Forming of goal foam || A2Z SKLLS
1:00
A2Z SKILLS
Рет қаралды 34 МЛН
ДОМАШНЕЕ ЭСКИМО//ПРОВЕРКА РЕЦЕПТА ТИК ТОК
0:22
ОЛЯ ПЕРЧИК
Рет қаралды 1,4 МЛН
A teacher captured the cutest moment at the nursery #shorts
0:33
Fabiosa Stories
Рет қаралды 52 МЛН
Giant balloon🤪 Subscribe to me👋🏻
0:27
Nazar S
Рет қаралды 9 МЛН