How to Repair Draeger Fabius Anesthesia Ventilator Fail problem.

  Рет қаралды 5,176

ROYSANTIK VLOG

ROYSANTIK VLOG

Күн бұрын

Medical Technology

Пікірлер: 15
@solomondivina6289
@solomondivina6289 11 ай бұрын
Tra nslate to ENGLISH
@iyklala-hs7hf
@iyklala-hs7hf Жыл бұрын
Ur camera is not showing what u are doing
@user-my5bu5mw4y
@user-my5bu5mw4y Жыл бұрын
Je peux pas comprendre votre longue est ce que vous pouvez faire la traduction?????
@TheCST1012
@TheCST1012 Жыл бұрын
Hi sir. Pump lang ba usualy nasisira pag.ventilator fail. Kung battery fail, pwd rin ba mag result to ventilator fail?
@roysantik
@roysantik Жыл бұрын
Pag sa pre use check nag fail ventilator yes sir may problema pump motor mo pag sa battery fail Naman po Walang kinalaman Ang vent. Syste me mag detect Ng battery.. mag palit kna Ng batt.
@TheCST1012
@TheCST1012 Жыл бұрын
Pre use sir, uma.andar naman ang pump. Kung i manual ko notor up, ayaw mag up.
@roysantik
@roysantik Жыл бұрын
@@TheCST1012 yes sir same din Po sa ginawa ko umaandar sandali tapos stuck na kaya Nung pinalitan Ng pump ayus na Wala Ng problema..
@TheCST1012
@TheCST1012 Жыл бұрын
Hi sir. Nag.taka lang ak sir kasi hindi pa nagagamit yung unit pero naka tambay lang yung machine for 3 years. 1 hour lang run ng machine sa testing lang. Kaya nag assume ak hindi pa siguro masisira yung pump.
@roysantik
@roysantik Жыл бұрын
Yun nga Po sir Ang problema sa akin din Kasi sa MRI sya naka standby very rare case Po sa MRI Ang pag gamit Ng intubation usually gamit lang sedition lang Po kaya Po nag stuck Ang biomed every 6 months ang check up..pero Po sa area Ng OR araw araw Po ginagamit Walang problema 5 years na.
@jeppysugue2445
@jeppysugue2445 2 жыл бұрын
Sir pwede ba lagyan nang lubricant yan sir?
@roysantik
@roysantik 2 жыл бұрын
Pwede sir basta non oil base lubricant.. pero sir Yung pump motor na Yan electronic control..parang stepper motor type sya ..
@RahulKumar-sz8fq
@RahulKumar-sz8fq 2 жыл бұрын
How can I contact u I have the same problem but in My machine peep Pump is working but Motor movement is not properly when we start peep calibration it takes a single up movement and then stop Can u please suggest me what should I do to resolve the
@roysantik
@roysantik 2 жыл бұрын
@@RahulKumar-sz8fq yes sir, the problem of your machine is the Pump, try to replaced the pump..
@iyklala-hs7hf
@iyklala-hs7hf Жыл бұрын
Can I have your email
Good to know about Fabius plus XL - What is what
4:47
Dräger Global
Рет қаралды 6 М.
Fabius- Comprobación de dispositivo
9:16
Dräger Global
Рет қаралды 12 М.
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 23 МЛН
女孩妒忌小丑女? #小丑#shorts
00:34
好人小丑
Рет қаралды 85 МЛН
Kids' Guide to Fire Safety: Essential Lessons #shorts
00:34
Fabiosa Animated
Рет қаралды 17 МЛН
КАКУЮ ДВЕРЬ ВЫБРАТЬ? 😂 #Shorts
00:45
НУБАСТЕР
Рет қаралды 3,5 МЛН
La machine d'anesthésie partie 1
8:50
France Parker
Рет қаралды 91 М.
Fabius plus XL Tutorial
11:14
Dräger Global
Рет қаралды 43 М.
Dräger Fabius GS premium - How to set-up
4:26
Dräger Global
Рет қаралды 18 М.
Dräger Fabius GS premium - Daily checkout procedure
3:43
Dräger Global
Рет қаралды 56 М.
03- Dräger Primus - device test
7:44
Dräger Global
Рет қаралды 12 М.
How to win a argument
9:28
ajaxkmr
Рет қаралды 480 М.
Advance Breathing System (ABS)- Disassembly, Cleaning, & Reassembly
12:44
Replacing pump motor and maintenance kit of Draeger MRI Anesthesia Machine.
1:07:31
MAQUINA DE ANESTESIA MINDRAY
8:05
CAPACITACIONES TECNOVIGILANCIA
Рет қаралды 15 М.
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 23 МЛН