How To Replace Your HVAC System From Start To Finish

  Рет қаралды 69,147

The DIY HVAC Guy

The DIY HVAC Guy

Күн бұрын

#1 Source for HVAC equipment: hvacdirect.com
Use my discount code 1MJTDLG4GM70 for an extra 3% off!
All my favorite HVAC tools: www.amazon.com...
IF YOU ARE IN NEED OF GUIDANCE WITH YOUR HVAC SYSTEM, whether it is diagnosing a bad part, replacing your system, or help with sizing, check out our membership program here: / diyhvacguy
For a small fee of $200, you will get assistance from myself when it comes to your hvac needs, whether it's sizing, diagnosing, or locating the correct equipment.
Here Is Where I Order All My Air Filters:
filterbuy.com/...
Follow us for more diy hvac tips & to enter for our giveaways!
Instagram: @diy_hvac_guy
Tiktok: @diy.hvac.guy
⚠️ Disclaimer:
This video is for educational purposes. Any and all HVAC repair work is done at your own risk. Any person attempting to deal with any type of refrigerant MUST have their EPA 608 certificate. The DIY HVAC Guy channel is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
The DIY HVAC GUY is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
Jobber: The #1 operations management software for home service businesses - Free 14-day trial + Exclusive discount: go.getjobber.c...

Пікірлер: 145
@matthewprather7386
@matthewprather7386 10 ай бұрын
Your demonstration of how to build the transition, including your thought process, was great!
@garysilver718
@garysilver718 10 ай бұрын
Great sheet metal work, I’m impressed. I installed my own first air conditioner unit and didn’t do a goo job on the sheet metal. Years latter I had the professionals install a new unit and their sheet metal job sucked.
@tinysand3517
@tinysand3517 10 ай бұрын
Lots of respect to you friend, not only to your AC knowledge and skills but to your sheet metal as well. Well done!
@wilassguess
@wilassguess 3 ай бұрын
Bro, I don't know your name other than DIY HVAC Guy. Thank you. I was able to follow your advice/guidance and install a brand new Goodman HVAC unit. I chose the furnace and AC unit instead of the heat pump option. I had a Rheem system in my home for years. Nothing against Rheem. Don't think they are a terrible company. The darn thing never worked correct. After the original installer came to my home they could never figure out what was wrong with my unit. The evap coil would freeze up during summer use. The heat pump never quite heated the house during the winter. When the heat pump stopped, we use the emergency heat. Overtime the coils for the electric heat broke down and fell apart. We had the Rheem system since 1995. Good run for a half baked installed system.
@Garth2011
@Garth2011 10 ай бұрын
Nice clean install, bending copper lines is king, full no cut/seem on the foam insulation outside, Nice clean whip and electrical routing. Inside lines with nice clean bends, no torch burns on the painted cabinets, clean tape job on the ducting/sheet metal. What I prefer on HVAC filters is the return registers that have the filter located in them, as that keeps the return ducting clean as well plus its more convenient when changing them. Some installs won't allow for them but most will.
@rickdiego5
@rickdiego5 10 ай бұрын
Great job on the video. One thing I question is putting the thermostat wire through the conduit with the 240 volt line. I don't think you can put the low voltage line in the same conduit as a high voltage. If there's a short from the 240 volt to the low voltage someone's going to get a surprise at the thermostat.
@RetiredSignDude
@RetiredSignDude 10 ай бұрын
Not really. Those thermostat wires would burn out in a second when exposed to the 240v line.
@user-su5ft8lc9q
@user-su5ft8lc9q 10 ай бұрын
​@@RetiredSignDudeno the want they will carry high voltage short distance.
@benhonna
@benhonna 6 ай бұрын
I believe it is ok if they are 600v rated.
@richlikeg3722
@richlikeg3722 11 ай бұрын
I could watch installs all day, each one has its own set of challenges and ways to go about it😮
@richlikeg3722
@richlikeg3722 11 ай бұрын
What was the price the other contractor quoted?
@DomReacts
@DomReacts 10 ай бұрын
True that man
@user-eh3qz4zv1o
@user-eh3qz4zv1o 3 ай бұрын
Thanks for your video's. On soldering get yourself the Turbo Torch and B tank with the different size tips. Heat your fitting only once since they are only 3/8" and 3/4". Heat the bottom and feed the top. A smaller flame using a B tank is better and safer inside the house.
@mikec7289
@mikec7289 11 ай бұрын
When reusing the line set and changing from r22 to r410a, don't the lines need to be flushed out to remove residual oil from the prior charge?
@petersmart1999
@petersmart1999 11 ай бұрын
Yepper!
@diyhvacguy
@diyhvacguy 11 ай бұрын
I’ve done tons of system without the flush and never had a single problem. But you can use the little foam pigs and send it through the line and they do a good job. I just do that if I know the system had compressor burnout
@josephtran-day6281
@josephtran-day6281 11 ай бұрын
@@diyhvacguy no no my guy. Flush it out it doesnt take long. It helps prevent contamination and freon restriction in the line.
@MrMiniHoop22
@MrMiniHoop22 10 ай бұрын
Awesome! I love your videos. I'm getting ready to switch out the old 80% HVAC system in my woodworking shop and am changing from r22 to r410a. I already bought the foam pigs and Staybrite 8. The old furnace developed a crack in the heat exchanger last winter and need to get everything done in October before it gets to cold in Indiana! Your videos make everything so easy to follow along & understand each step!@@diyhvacguy
@06GOAT56943
@06GOAT56943 10 ай бұрын
@@diyhvacguy​​⁠so you don’t flush unless it was a burnout? That makes no sense. You should be using flush or the pigs considering mineral oil and Poe oil are not compatible. Why do you people have to be such hacks 🤦🏻‍♂️
@davidskaggs9914
@davidskaggs9914 10 ай бұрын
FYI...I have had issues where running the thermostat wires in conduit with 120/240v has caused issues. I appreciate your knowledge on doing the transitions. Very professional work
@spoonwings1981
@spoonwings1981 3 ай бұрын
Are you allowed to run high and low voltage together?
@Greg-McIver
@Greg-McIver 11 ай бұрын
If you ever do a fresh air heat exchanger, I'd love to see that. Love your videos.
@Eggrollofdoom
@Eggrollofdoom 11 ай бұрын
What's good about staybrite is you don't have to flow nitrogen when soldering.
@khoatran4841
@khoatran4841 7 ай бұрын
you do not use solders on hvac systems, because they run at higher pressures and vibrations. tin-lead is rated for 150 psi at 150F, tin-antimony is 400 psi at 150F. hvac systems can exceed 450 psi due to certain conditions. And that's not including the vibration while the systems are running, slowly putting crack on that solder. braze has stronger mechanical connection.
@konglin3126
@konglin3126 Ай бұрын
He used plumbing solder, not for the HVAC.
@williamfinnegan6673
@williamfinnegan6673 3 ай бұрын
Saved me a bunch. You da man! Took me about 20 minutes to move. Thanks.
@user-su5ft8lc9q
@user-su5ft8lc9q 10 ай бұрын
Back in the 80ds most all electrical whips came with low voltage wire in the whips with high voltage around Missouri area. Then the rules changed because of high voltage jumping into low voltage side because of close proximity to each other. I've actually seen T-stat s melt off the wall.
@diyhvacguy
@diyhvacguy 10 ай бұрын
Dang that’s crazy!
@homeauthorityllc
@homeauthorityllc 11 ай бұрын
Thank yo very much for another great vid. I can't even begin to count the number of filter housings I've seen that aren't sealed along the bottom and the back to the return plenum or the furnace cabinet! Easy enough to check with a flashlight.
@jma24
@jma24 Ай бұрын
Hey there - NEC doesn’t allow for low voltage conductors to be run in a conduit with line voltage. Needs to be separate. Love the videos.
@nwellinghoff
@nwellinghoff 9 ай бұрын
Looks to be about 7k of work! You are a good friend.
@kw_boeing
@kw_boeing 11 ай бұрын
Great work, Dave! Excited to see you next week!
@johnskalski1033
@johnskalski1033 2 ай бұрын
Very good installation video, however I must take exception to a couple of things electrical that are not permitted by NEC. Thermostat wires are generally considered class 2 (low voltage 12-24V) wiring and can't be run in the same raceway as class 1 (power wiring). Like in life there are always exceptions, most class 1 wiring has insulation rating of 600V. If the thermostat wiring is also 600V insulation you could do it, not normally though. Also it is never permissible to use a disconnect means as a raceway, so running the thermostat wiring through the disconnect to get into the same raceway as the load side of the disconnect feeding the condenser is prohibited regardless of the insulation value of the thermostat wiring. Inside of manufacturers equipment is a different story I have seen some crazy stuff inside large air handlers and equipment but as long as it's UL listed, electrical inspectors can't say much about it
@Fatal_Error_Gaming
@Fatal_Error_Gaming 11 ай бұрын
Yo, really enjoy watching your vids man. Very therapeutic. Question, what do you guys do when someone has their airflow unit in the attic? I mean I have like a big one in my attic. And it sure isn't coming down through the attic door. What do y'all have to do? Cut a hole in the roof and pull it out that way? They apparently put it in when they were building the house. Anyways. Hope to hear your reply. Cheers. And awesome job on this vid.
@jeremykg1569
@jeremykg1569 Ай бұрын
excellent instructor
@christran419
@christran419 29 күн бұрын
How does one suck out the refrigerant from ac line if condenser does not work? Thanks. Great Video by the way?
@NickShoust
@NickShoust 11 ай бұрын
It's just crazy to me that that the heat can be that close up against the coil. I would have thought the air passing through would be separated.
@matthewprather7386
@matthewprather7386 10 ай бұрын
I think the output side of the furnace isn’t supposed to be super hot - best efficiency happens when there’s not too large a difference between the house temp and the outlet temp. One factor in achieving that is the fan must be running while the burner is on. The other thing is the coil probably isn’t super delicate - the pookie is probably more sensitive to the heat than the coil itself.
@percytsang8230
@percytsang8230 5 ай бұрын
Ho Sir, here is a question that Don't need to remove the Valve Core on the new machine before welding? I’m a beginner. Really asking about it. Thank you.
@user-kc3jz7oh4z
@user-kc3jz7oh4z 3 ай бұрын
Debatable since how he solders is so fast tbh
@francoispierrechanguion4128
@francoispierrechanguion4128 11 ай бұрын
Why not Staybrite 8 ? Thanks great content.
@bjkjoseph
@bjkjoseph 11 ай бұрын
That duct work you did was pretty good
@JNHEscapes
@JNHEscapes 22 күн бұрын
May be a dumb question, but why go to the trouble to angle the ductwork at all…why not just build a square box to connect the coil to the upper duct?
@ncooty
@ncooty Ай бұрын
@17:51: Mark that hot white conductor with red or black tape.
@billy2bob63
@billy2bob63 11 ай бұрын
Since you did a video for the surge protector for the ac condenser can you please do a video for a surge protector for the inside heating unit to protect that?
@petersmart1999
@petersmart1999 11 ай бұрын
Why not protect the whole house!
@billy2bob63
@billy2bob63 11 ай бұрын
@petersmart1999 My power from the electric company has a power surge protector on it but if I get a lightening strike on my house that will protect the utility company from the back flow but not my individual heating unit or ac condersor! That's why I need individual surge protection on each item.
@petersmart1999
@petersmart1999 11 ай бұрын
@@billy2bob63 You can install one in you Breaker Panel! It will protect the whole house!
@SW-nq1bx
@SW-nq1bx 9 ай бұрын
Also need to protect your appliances & electronics. They all have computer boards, and power surges can ruin them. I've replaced 3 boards on my refrigerator at $100 each (at cost) not including install by repair service.
@ForgetU
@ForgetU 11 ай бұрын
Did I miss how you saved them $7000? Long day, good work.
@IvanHVAC
@IvanHVAC 11 ай бұрын
Same, probably someone else quoted them 7k more.
@Fatal_Error_Gaming
@Fatal_Error_Gaming 11 ай бұрын
Click Bait. When the title says something like his title says, a person that's interested in replacing their unit that's what they are gonna see..the save $7000 and in turn saves you from clicking on some other random ac install video. And that insures his video is more clickable than other vids. Make sense? Psychology and the KZfaq algorithm. Lol😂
@AF-O6
@AF-O6 11 ай бұрын
I thought you moved to staybrite. Perhaps codes or the customer demanded brazing, or dissimilar metals???
@Marco-qe5zw
@Marco-qe5zw 3 ай бұрын
@@AF-O6 was he not using staybrite8 when soldering??
@BryanTorok
@BryanTorok 10 ай бұрын
Sucking the refrigerant into the unit being replaces only works if the unit being replaced runs properly and doesn't leak. That then begs the question: Why replace a perfectly good working unit? Before someone says because the new unit is more efficient, there are other HVAC channels where they have done the math to show that the payback period is between 10 and 20 years. By the time the new unit saves enough to pay for itself, it will likely be shot and need replacement.
@diyhvacguy
@diyhvacguy 10 ай бұрын
Peace of mind plus efficiency. This is a 16 seer, so it’s not a huge price difference from standard efficiency. But mostly this customer wanted peace of mind knowing his system was new and not going to crap out in the middle of summer or winter. Cheers
@BryanTorok
@BryanTorok 10 ай бұрын
@@diyhvacguy Tnx for the reply.
@Luckingsworth
@Luckingsworth 8 ай бұрын
Mine is 100% fully functional. And it is from 1976 😂 I need to move the entire system to make the basement more usable when finished (currently the furnace is in the middle of the basement), move the condenser to be on the side of the house rather than the backyard where a patio is going to go, and yes I would like something more efficient. Not to mention the increased resale on the house will be more than enough to bump up that payback period.
@BryanTorok
@BryanTorok 8 ай бұрын
@@Luckingsworth Those are all good reasons. Often an improvement like that doesn't actually increase the selling price of the property, but makes it easier or faster to sell. That can be its own sort of payback.
@brucemadden1626
@brucemadden1626 10 ай бұрын
Another excellent "tutorial" video--many thanks!😀
@JLV-l4c
@JLV-l4c 9 ай бұрын
Thank you papa excellent jod!! Thank you for sharing!!
@hosocat1410
@hosocat1410 10 ай бұрын
Thanks for all your great videos. Do you have an online source youd recommend for purchase of complete units?
@diyhvacguy
@diyhvacguy 10 ай бұрын
Yes! Hvacdirect.com If you need help locating a system reach out to me at diyhvacguy@gmail.com and I’m happy to help. Cheers
@petersmart1999
@petersmart1999 11 ай бұрын
When you solder,its best practice to start at the bottom of the joint,and work your way up! 1,2,3 #1 Heat pipe,#2 Heat face of socket,#3 Move heat to back of socket.Bottom to top!
@JohnSmith-uy7sv
@JohnSmith-uy7sv 11 ай бұрын
🙄🙄🙄🙄🙄🙄🙄🙄🙄🙄🤣🤣🤣🤣🤣🤣🤣🤣🤣🤣
@trucle1859
@trucle1859 11 ай бұрын
Thank you Dave. Great video always
@CoreyRaines
@CoreyRaines Ай бұрын
@6:02 The size of them fuses is.. Copper pipe..
@zimpler8340
@zimpler8340 2 ай бұрын
“Beer can cold”😂😂😂😂
@robtorres5518
@robtorres5518 Ай бұрын
A one band-aid job. Not bad
@canyondan
@canyondan 11 ай бұрын
Thanks for the videos
@bignicnrg3856
@bignicnrg3856 11 ай бұрын
Crushing it!!!!
@daylbrinkman
@daylbrinkman 10 ай бұрын
Looks like they were using the old reliable "pieces of copper pipe" fuses. Very high capacity.
@Matts_Crafty
@Matts_Crafty 10 ай бұрын
Great sheet metal work my friend! I cringe every time you grab that crap with no gloves hahaaaaa!!!! Keep up the great content!!!
@diyhvacguy
@diyhvacguy 10 ай бұрын
Thanks brotha
@Verycrazychimken
@Verycrazychimken 4 ай бұрын
​@@diyhvacguyI. Need the high school diploma to graduate and start working
@garysgarage.2841
@garysgarage.2841 12 күн бұрын
What's a fair labor charge for a job like this.
@mrsayao
@mrsayao 5 ай бұрын
Can I use standard needle gauges for most of the testing?
@aaronwestbrook107
@aaronwestbrook107 10 ай бұрын
Why didn't you turn the condenser service ports facing outward for easier service? Because more brazing and wire? You took the easy route... well done overall though.
@sir-cloutt3417
@sir-cloutt3417 2 ай бұрын
why solder vs brazing just curious
@sebastiansanchez3248
@sebastiansanchez3248 3 ай бұрын
How do you know when to braze or solder?
@menimeni9825
@menimeni9825 10 ай бұрын
Hi Dave, thanks for all the great information. Question; toward the end of the video did you show the process on how to install the refrigerant from the old unit to the new unit. Do you have a separate video on that process?
@diyhvacguy
@diyhvacguy 10 ай бұрын
All new condensers are precharged so the old refrigerant stays in the old condenser and is not used in the new one 👍🏼 watch some of my other videos and it will make more sense
@menimeni9825
@menimeni9825 10 ай бұрын
👍@@diyhvacguy
@davecullum9631
@davecullum9631 3 ай бұрын
These are two different freons and would destroy the new system.
7 ай бұрын
Whats the difference between brazing and soldering? Both methods appear the same to me aside from different heating methods and melting materials used. Could I an entire lineset via soldering or is there some reason that wouldn't be advised?
@user-hk7qq2wo5m
@user-hk7qq2wo5m 10 ай бұрын
Love your video. Can you recommend any HVAC company in Boston, MA? I want to replace 2 forced hot air gas furnaces in a 2-family house. Many thanks.
@JimLarsen108
@JimLarsen108 Ай бұрын
How do you dispose of the old condenser unit that is filled with refrigerant?
@crissalamango41
@crissalamango41 Ай бұрын
I used a dolly, put the unit at the curb on garbage day. It was gone in 15 minutes, the scrappers took it. I’ve heard some folks will sell it.
@huskers993
@huskers993 6 ай бұрын
Noob here. Why did you not hook the gauges up after to check the super heat to see if it had the proper amount of r410a and instead looked at just the low pressure? I watched a different video and you were all about super heat being about 10 for that day.
@RyCorp77
@RyCorp77 11 ай бұрын
Those 'fuses' looked like just regular copper pipe. Kept blowing fuses and said f-it lets create a fire hazard.
@paulrozinski1488
@paulrozinski1488 10 ай бұрын
Glad that I wasn’t the only one who noticed this 👍👍
@user-su5ft8lc9q
@user-su5ft8lc9q 10 ай бұрын
Sure was ,kinda like putting a penny behind the old screw in glass Fuze back in the day B4 breakers come out.
@ronb6182
@ronb6182 10 ай бұрын
​​@@user-su5ft8lc9q no worst penny can melt easier. I think the only time a penny was used is when Dad had the front porch planed, the planer kept blowing fuses during start up. The penny was removed after the job was done I think Mom asked me to remove the penny don't remember what I used to remove it probably a non conducting object. This reminds me of a cartoon in the local electric code book. It read: I been putting pennies in the fuse box for 20 years. It showed the house burned down. 73
@danmeyo
@danmeyo 5 ай бұрын
did you flush the existing lines? Did it go from R22 to R410a?
@hollidaydoc45
@hollidaydoc45 10 ай бұрын
When you pulled the vacuum with the blue hose, you said you pulled the core out of the service side suction line. Do you also pull the core out of the core removal tube port that connects to the vacuum? Thanks
@diyhvacguy
@diyhvacguy 10 ай бұрын
There is no core on a core removal tube. Just the one at the service port where the tool is connected 👍🏼
@jorgevillalpando4269
@jorgevillalpando4269 2 ай бұрын
How can we replace the system form r22 to a410
@hugomacias3348
@hugomacias3348 6 ай бұрын
Nice video do you flush line set ?
@stevesolt4036
@stevesolt4036 10 ай бұрын
When reusing pipe do you clean out old oil?
@ryanpowell9522
@ryanpowell9522 10 ай бұрын
So how does the warranty work with this for the hardware? I've you won't be able too.
@dallasdandy6276
@dallasdandy6276 10 ай бұрын
Just interested in this and I had a question. I'm not tech just an enthusiast. Can you replace the condenser only say upgrade it to lets say 2t to 3t without changing coil or os it mandatory to change both?
@wilassguess
@wilassguess 10 ай бұрын
I want to install my own ac unit with gas heat option what are my options and where do I purchase it? I'm leaning toward carrier. Any advice and guidance appreciated.
@Hooterzutoob
@Hooterzutoob 10 ай бұрын
Great videos as always, quick question, what watch are you wearing?
@diyhvacguy
@diyhvacguy 10 ай бұрын
Apple Watch ultra 🤘🏼
@wilassguess
@wilassguess 4 ай бұрын
where is your condensate drain and pan?
@bigdaddy4975
@bigdaddy4975 10 ай бұрын
Do you use the same gauges for all your jobs? I’m just asking and nobody can really answer me with a straight answer can you use the same gauges for r22 and 410 a?
@diyhvacguy
@diyhvacguy 10 ай бұрын
Yea I use the same gauges. Never had a problem. Just make sure you purge the lines if the last unit you hooked up to had a different refrigerant
@tinysand3517
@tinysand3517 10 ай бұрын
how many tons is the new unit? Will the 3/4 suction line can handle ?
@diyhvacguy
@diyhvacguy 10 ай бұрын
3 ton and yes 3/4 is generally good up to 3-3.5 ton anything above is typically 7/8
@CatholicBoy1957
@CatholicBoy1957 10 ай бұрын
I'm wondering if the homeowner got a 15,000 dollar quote on the same Ruud brand equipment or was it on a pricey brand like Carrier. .
@CatholicBoy1957
@CatholicBoy1957 10 ай бұрын
@@bluejay713 but would you still save 7000 dollars with Goodman? .
@daddygc5814
@daddygc5814 10 ай бұрын
Nice job,how did you clean your old r22 lines
@Wordwagon
@Wordwagon 4 ай бұрын
He didn't
@user-zy3qj2hb2s
@user-zy3qj2hb2s 10 ай бұрын
You saved them $7,000.00 dollars. How much did you charge them ?
@sumbamotor
@sumbamotor 4 ай бұрын
Why you did not deburr
@Jcewazhere
@Jcewazhere 10 ай бұрын
Know any trustworthy HVAC techs in Pueblo CO? Home builder screwed me and I need a heat pump replaced.
@InsidiousDr9
@InsidiousDr9 11 ай бұрын
Do you later reclaim the r22, or is there a place that takes the unit with r22 in it?
@diyhvacguy
@diyhvacguy 11 ай бұрын
Yea I reclaim it later on my trailer 👍🏼
@petersmart1999
@petersmart1999 11 ай бұрын
Recover,not reclaim!
@pilotboba
@pilotboba 10 ай бұрын
Nice. Why did they save $7000 ???
@JohnSmith-uy7sv
@JohnSmith-uy7sv 11 ай бұрын
You did it for free and the hvac was free too? How many ton was it?
@diyhvacguy
@diyhvacguy 11 ай бұрын
We did not do this for free but they were quoted 7000 more then our bid which is absolute insanity. It was a 3 ton system
@JohnSmith-uy7sv
@JohnSmith-uy7sv 10 ай бұрын
@@diyhvacguy yes, my bad. I commented before I watched the video and saw you replaced the furnace too. I'm always thinking in south flori duh heater terms with my heater coils in my Hvac mobile home system for $200+ super cheap and easy to replace. thanks 🙂
@user-tx4ts5vk5f
@user-tx4ts5vk5f 2 ай бұрын
I would definitely be wearing gloves. I even touch that crap I have 15 paper cuts. Then crying like a bitch all night. And hands hurt so bad can’t install the next day.
@danielvicente1051
@danielvicente1051 Ай бұрын
Those look like copper pipe not fuses!!😂😂
@9to5techs
@9to5techs 7 ай бұрын
Why would you replace a unit that's still working. Only rich elites can do that.
@JackofAllTrades1
@JackofAllTrades1 5 ай бұрын
Those fuses are copper pipes lol
@user-xo7gh4zi7l
@user-xo7gh4zi7l 7 ай бұрын
saved $7000? how
@diyhvacguy
@diyhvacguy 7 ай бұрын
She was going to pay 15000 and we did it for $8,000.
@actechBaDsHaKhAn
@actechBaDsHaKhAn 10 ай бұрын
@RW-to2fy
@RW-to2fy 8 ай бұрын
Wish Dave hadn’t sped up his voice can’t understand what he saying
@robbyphillips1758
@robbyphillips1758 10 ай бұрын
Can you come to my parents home? They are fighting heath issues, dad, dementia, mom Copd,
@jsa4864
@jsa4864 4 ай бұрын
Not ghetto, AmeriKan classic ;🤣🤣🤣🤣🤣🤣
@ryanslats6764
@ryanslats6764 10 ай бұрын
How much did this replacement cost?
@diyhvacguy
@diyhvacguy 10 ай бұрын
We charged $8000 for this install. Their quotes were $15k+
Is DIY'ing Your HVAC A Good Idea?
38:25
The DIY HVAC Guy
Рет қаралды 42 М.
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН
Happy birthday to you by Tsuriki Show
00:12
Tsuriki Show
Рет қаралды 10 МЛН
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 44 МЛН
Lehanga 🤣 #comedy #funny
00:31
Micky Makeover
Рет қаралды 30 МЛН
Full Air Conditioner Replacement Using Stay Brite 8 Solder!
35:04
The DIY HVAC Guy
Рет қаралды 33 М.
Save THOUSANDS Replacing Your Gas Furnace Yourself.
54:49
The DIY HVAC Guy
Рет қаралды 326 М.
How To Use AC Gauges
26:34
Benjamin Sahlstrom
Рет қаралды 1,2 МЛН
Did You Know You Can Replace Your Own Air Conditioner?   -SAVE THOUSANDS-
23:51
Condenser Install 3D
36:50
HVAC School
Рет қаралды 320 М.
Goodman Condenser Replacement - (start to finish)
20:44
Apartment Maintenance Pro
Рет қаралды 34 М.
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,8 МЛН
The Top 7 Things AC Companies Don't Want You To Know How To Do!
17:29
How To Replace Your HVAC System And Save THOUSANDS.
31:14
The DIY HVAC Guy
Рет қаралды 240 М.
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН