Worcester Bosch Greenstar. How to set up a Worcester bosch boiler. Today we have a Worcester bosch engineer and he is showing how advanced the Worcester Bosch CDI Boiler is.
Пікірлер: 191
@LordPlaythellSteele-er4qi6 ай бұрын
Brilliant video and Voiceover... Now that I understand my boiler I can now sort out what plumbers haven't managed to do. Huge thanks...
@thomasdavidowen16 Жыл бұрын
Really handy info about fan running time and sticking bearing plates, thanks Allen!
@brianwood52204 жыл бұрын
Great video once again Allen, i never get bored watching your channel. Thanks to both of you.
@AllenHart9994 жыл бұрын
Thank you so much
@tpmbe2 жыл бұрын
Great video , very helpful to run your system efficiently. Thank You
@adriatikqypi93564 жыл бұрын
Brilliant video. Love watching and learning from your videos Allan .
@AllenHart9994 жыл бұрын
Adriatik qypi this one is thanks to Paul 👍
@terryfitzsimmons41804 жыл бұрын
Thanks Allen and Paul, good info on what can get you perplexed with the codes!!👍👍🍻🥳
@AllenHart9994 жыл бұрын
Thanks for watching.
@philipsmith54552 жыл бұрын
Thanks for doing these vids, really interesting and helpful, they are helping me improve my knowledge please keep doing them 👍
@tommyblackman71194 жыл бұрын
Great vid, great tips on the Worcester Keep them coming ALLEN
@AllenHart9994 жыл бұрын
Thanks 👍
@stephenrowen94353 жыл бұрын
Great video, although I like many others do installs as well as boiler repairs it is still beneficial especially for those who only do installs to set up the boiler to optimal efficiency.
@AllenHart9993 жыл бұрын
Great point!
@nicksharp9122 Жыл бұрын
Very useful video, thanks for posting it.
@gwendolynshabka63287 ай бұрын
That was one of the best instructional videos Ive ever seen
@stevo0861 Жыл бұрын
Very informative once again. Thank you.
@paulrossiter95674 жыл бұрын
Quality output from you Alan 👍
@AllenHart9994 жыл бұрын
Thank you. VDI2035 coming soon
@robertjburns92066 ай бұрын
Hi, you've just saved me from buying a new boiler, the overrun 120 seconds for bearing plate condensation has fixed the problem 👍
@johnogrady63763 жыл бұрын
Many thanks Allen,for a well informed video
@AllenHart9992 жыл бұрын
Thank You
@DrAPHSomani2 жыл бұрын
Very useful information, thank you.
@jimmyclark82294 жыл бұрын
Top video keep them coming it well appreciated
@AllenHart9994 жыл бұрын
Thanks.
@MrReza21azer4 жыл бұрын
Thank you. Very informative 👌
@AllenHart9993 жыл бұрын
So nice of you
@garyking37113 жыл бұрын
Great video very helpful thanks.
@AllenHart9993 жыл бұрын
Glad it was helpful!
@jayhambleton58344 жыл бұрын
Thanks Alan great vid, I’ll be downloading that manual
@AllenHart9992 жыл бұрын
Thank You
@tommytanswell41874 жыл бұрын
They've defo got into you as some of your vids you've hit them hard. Lovely vid al x.
@AllenHart9994 жыл бұрын
tommy tanswell always honest in all my videos buddy. Thanks for watching 👍
@MuskMuskeeno3 жыл бұрын
Thank you for sharing... Very useful. 👍👍
@AllenHart9993 жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@richardhodgson74434 жыл бұрын
Really detailed video, thanks again
@AllenHart9992 жыл бұрын
Thank You
@abdulh634 жыл бұрын
Another great video 👍
@AllenHart9994 жыл бұрын
Thanks for watching.
@jameshawkins52803 жыл бұрын
Well yet another great video
@AllenHart9992 жыл бұрын
Thank You
@Moocow99917034 жыл бұрын
Not keen on Worcester I'm a Baxi man but this video was really helpful for servicing, thanks Allen
@AllenHart9992 жыл бұрын
Thank You
@amcluesent Жыл бұрын
Just made the suggested adjustments to my GREENSTAR 30CDi
@32dartsking2 жыл бұрын
thankd as always very imformative
@cfgman121 күн бұрын
Nice one Allen useful video
@andyd80803 жыл бұрын
Brilliant video keep up good work 👍
@AllenHart9993 жыл бұрын
Thank You.
@andyd80803 жыл бұрын
@@AllenHart999 I had a watch of your electric check video the other day it was 100% spot on I was I senior break down engineer for scottishpower and they where drilled in to us and was the best learning point in my career 👍
@ryandow39544 жыл бұрын
Another great video! That info is really useful 😀
@AllenHart9994 жыл бұрын
Thanks
@AllenHart9994 жыл бұрын
Please give it a thumbs up if you can ❤️
@ryandow39544 жыл бұрын
@@AllenHart999 Done 👍
@AllenHart9994 жыл бұрын
@@ryandow3954 Thank You
@1mannik4 жыл бұрын
Great video 👌
@AllenHart9994 жыл бұрын
Thank You
@haccogas24984 жыл бұрын
Thanks Alan and Paul
@AllenHart9994 жыл бұрын
Thanks for watching.
@lukehodges45114 жыл бұрын
Thanks it always useful
@AllenHart9994 жыл бұрын
Thanks.
@ramramlal44433 жыл бұрын
Thank you for the information
@AllenHart9992 жыл бұрын
Thank You
@jaydunstan1618 Жыл бұрын
Great stuff.
@valentintrapkevic44964 жыл бұрын
thanks a lot Allen
@AllenHart9994 жыл бұрын
You are very welcome. Big thank you to Paul for doing these videos.
@zoe7674 Жыл бұрын
Useful video, thank you. Just wondering how to set the flow rate please?
@richardlyons75824 жыл бұрын
Nice one Allen
@AllenHart9992 жыл бұрын
Thank You
@annemweke96683 жыл бұрын
Thank you for information
@AllenHart9992 жыл бұрын
Thank You
@notoriousleo61878 ай бұрын
Helpful mate✔️
@AllenHart9998 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@Lizapendleton Жыл бұрын
Brilliant thanks
@neilcameron434 Жыл бұрын
Thanks for this
@johnboy12324 жыл бұрын
I always think a good visual demonstration is worth a lot more than reading about it . If increasing the fan overrun time dries out the bearing plate why is it not set to this as a factory default?.keep up the good work .
@AllenHart9992 жыл бұрын
Thank You
@briangraham49092 жыл бұрын
Thanks Paul
@simongeorge703 Жыл бұрын
Hi Allen Great Video - Any chance you know what the minimum flow rate for these boilers should be? Have a 40CDi Classic feeding one mains pressure hot water circuit off a two port valve and then two rad circuits (top and middle floor) each off their own 2port valves and then two underfloor manifolds, off another two 2port valves. All rads (except bathrooms) fitted with TRVS.... But i am struggling getting the boiler/circuit to manage all the pressure combinations and actually stay fired up when circuits are on/almost up to temp... Boiler keeps going up to 75 degrees (setpoint) and overshooting, turning off, pump continues and finally the boiler comes on again before repeating same. Effectively the boiler is not actually on that much :( I think it is related to flow issues so trying to decide what and how many auto bypass valves to fit (but need boiler flow rate to work this out)
@stevenhunter39282 жыл бұрын
Should the green burner light be lit up when the heating is turned on? My turns on when the hot water is running but not when the heating is on.
@ivandrozd82623 жыл бұрын
It will help me a lot on Worcester breakdown! Thanks Paul and Allen.
@AllenHart9993 жыл бұрын
Great to hear!
@ivandrozd82623 жыл бұрын
@@AllenHart999 can't see a link for Worcester Manual as mentioned in the video.
@gilldanier4129 Жыл бұрын
Hi Allen, I'm just a consumer. Can you tell me please, does the pilot light need to be on all the time (ours isnt) or is it self ignition? Thanks for your support.
@mirzaamirbaig1046 Жыл бұрын
Thanks paul
@clarepickford83708 ай бұрын
Thankyou very interesting
@AllenHart9998 ай бұрын
Glad you enjoyed it
@dickie9972 жыл бұрын
Where is the section on connecting to the weather compensation BB ports?
@ThePharmaCoach2 жыл бұрын
Hi, what are all the other settings for?
@bhellsun2 жыл бұрын
Can you let me know which model of CDi boiler is this ?
@jayendraamlani8614 жыл бұрын
Very nice video.
@fakrulislam16523 жыл бұрын
Nice presentation of combi boiler. I need to put new Worcester 28cdi for 3 bed room and 1 bath room house.Can I have your contact number please. Fakrul from Sheffield thanks
@AllenHart9992 жыл бұрын
Thank You
@olympusplumbingheating5027Ай бұрын
Top video
@mgbroadsterJ Жыл бұрын
Does it lower the minimum kw ?
@kieranwims19764 жыл бұрын
After 5b to 120, go to 9d on 2nd level diagnostics. It is the fan speed, turn from 50 to 55 and this also helps to dry the bearing plate. Also, 6d on level 1 diagnostics will show the dhw flow rate.
@AllenHart9992 жыл бұрын
Thank You
@ci-ryder Жыл бұрын
How do you navigate to the 2nd level diagnostics menu?
@DaviNaizer-fo4pu Жыл бұрын
@@ci-ryder From the service manual: "To enter the second service level enter the first service level and then press the eco button and holiday button simultaneously for 3 seconds."
@michaelgiles95454 жыл бұрын
Great video Allen, any chance of paul doing a video of servicing a greenstar i boiler and sharing a few tips.
@leighcannon7644 жыл бұрын
Check out Geoff Needs Training. Like Allen he does some good videos. But Geoff specifically covers WB
@AllenHart9992 жыл бұрын
Thank You
@mgbroadsterJ Жыл бұрын
Can you range rate a Worcester 24i system boiler ?
@michaelhall7921 Жыл бұрын
Dear Allen I'm a very old commercial heating engineer but have fitted all brands and fuels of domestic postage stamp boilers as well as light commercials in Whitbread pubs 50 mile radius of and including Nottingham etc. I have been looking at and advising a very cleaver electricai designer and his wife our niece, a leak or two on their Worscester CDi 37 combi they have in their loft. It has good access but the system should have a few improvements done by someone qualified, who is very familiar with Worcester Combi's of this type. Please do you know if that boiler has a safety = water low pressure switch that should prevent the sequence , even the pump from rotating in addition to the overheat stat? The pressure gauge on an 8 year old boiler same as usual can stick as this one does so I've advised a new replacement. I said the pressure needs to be known! I managed to turn the plastic top to stop the auto air pressure switch as it was passing again a notorious regular possible fault. I advised due to him being electrical to fit a warning device re the water pressure if it looses pressure an easily seen light or sounder as the boiler is not visible from below. With not being able to see a low water pressure- switch within the boiler Installation instructions, I would think there is not one (shame on Worcester) but it would be most helpful that you may well confirm our thinking that indeed there is the lack of one. Best wishes ( I'm very please I don't now have to sort out these complex hard to work on nightmares of a boiler!) full of plastic components.
@mrt44093 жыл бұрын
Hi I've a Worcester 35cdi I've set the boiler control on no. 4 is that OK or should it be higher for a 3 bed house temp on thermostat is set to 20.5c
@AllenHart9992 жыл бұрын
Thank You
@princegrant22759 ай бұрын
Thank you
@AllenHart9999 ай бұрын
Thank You
@AllenHart9999 ай бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@bonestojanoski81783 жыл бұрын
i have a junker 30kw but i dont know how to adjustit the functions a1a2...can somone explain which is for what and should be standing on those?
@AllenHart9992 жыл бұрын
Thank You
@davidgoodwin57973 жыл бұрын
Helpful video but no link to the manual. Searching the Worcester web site I can only find the service manual which doesn't cover the service menus. Can anyone point in the right direction?
@AllenHart9993 жыл бұрын
If you search for it in google it should come up. Thanks.
@halimahzaman68873 жыл бұрын
Are boilers usually wired on a spurred fuse and is this usually fitted by the plumber?
@AllenHart9992 жыл бұрын
Plumber normally connects to the spur. Thanks.
@jimmaxwell22598 ай бұрын
Must you do another Telegan flue anaysis once you finished with the settings changes? I assume range rating is affecting the combustion?
@AllenHart9998 ай бұрын
Yes, Always check manufacturer instructions.
@Kavanaghb Жыл бұрын
I’m having issues with a new green star Bosch 150. Showers run hot for 5 minutes then it goes Luke warm then gets hot again any ideas
@AllenHart9998 ай бұрын
i don,t know what that is.
@MrJwinne3 жыл бұрын
Great tutorial, the only issue as service technician and as a customer it gets very frustrating waiting for parts on on all these new combinations and tankless systems are . Way too many moving parts IMO . Every manufacturer makes these units so it’s kind of a nuisance when you have to wait for tech support , as well .
@AllenHart9993 жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@MrJwinne3 жыл бұрын
I sure will. Thank you for taking the time out to show us guys in the field .
@AllenHart9993 жыл бұрын
@@MrJwinne If you are a plumber or gas engineer please consider sending me your videos. Thanks. Whatsapp 07725 692699
@jamescampbell7780 Жыл бұрын
We have a 30 CDI but we were told on installation that the right hand side rotary control is redundant! This video shows it in use? So, is there a component missing in my boiler?
@stevelambert6689 Жыл бұрын
That's because yours is not a combi if it's not in use (i.e. Classic)
@jamescampbell7780 Жыл бұрын
@@stevelambert6689 So when I asked for the original quotation for this boiler, should I have been told at that stage that that component is not installed and is regarded as an extra and priced accordingly. If so, I would have had that component included within the quotation. So can that component be installed now?
@glynnwhittaker92662 жыл бұрын
Does anyone know....How do I get the pilot light back on? Reset many times and still no pilot light..
@AllenHart9992 жыл бұрын
They do not have a pilot light.
@maxamedcabdullahi36933 жыл бұрын
Tnx
@AllenHart9993 жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@Brijoolz4 жыл бұрын
If you use the range rate, does the boiler come down to the same ‘lowest’ rate? Essentially, the boiler will work between a closer band, ie, 6-16kw, rather than 6-30kw.
@AllenHart9994 жыл бұрын
Allen Hart it will work down to 6kw minimum, the 1A function is your maximum central heating output, lowest range doesn’t change
@harksjuttla98013 жыл бұрын
Hi allen, Is there anyway I can contact Paul? I have a problem with my Bosch CDI Combi boiler. Many people have come and gone but cannot fix it. Thanks
@AllenHart9992 жыл бұрын
Not really no. Sorry.
@jamiemorris87343 жыл бұрын
Great Video Allen. Could you advise so I could try and get maximum efficiency please? 1A = was set 100%, reduced to 70% to reduce max firing and cycling. Circa 17kw on DHW cylinder primary coil and estimated circa 20Kw heating required to house. Say allow 20Kw - 20/30 = 67% allow therefore 70%. 2B = Max CH temp currently set at 88C (factory default), could this be dropped to say 70C to allow cooler to touch rads, less cycling and slightly more efficient? Whilst also maintaining 70C to DHW coil (60C DHW set temp / 65C storage temp) I'm assuming the display temp on the boiler is the flow temp - therefore I'm thinking circa 70C out circa 50-60C return to allow maximum efficiency?
@AllenHart9992 жыл бұрын
Thank You
@eamonnhurst85773 жыл бұрын
How do you turn the boiler on once you have switched it off
@AllenHart9992 жыл бұрын
Thank You
@Mick5262 жыл бұрын
We've just had a smart meter fitted and the engineer switched the boiler off. Now the boiler (34CDI Classic) is running pre heat. I've downloaded the manual and read the instructions to deactive it but it doesn't seem to work. It says hold holiday button down but there's no response. No faults showing, just non responsive holiday and eco button
@AllenHart9992 жыл бұрын
did you sort it? Thanks
@Mick5262 жыл бұрын
@@AllenHart999 yes thanks, I couldn't see the green light on the eco button as it's very dim. The Mrs pressed it once and came on, she's shorter than me and could see the LED light that I couldn't 🤦🤦
@sas84038 ай бұрын
my output for the central heating is 77, will not go above this, going above this well set to back to 29
@runabegum53873 жыл бұрын
I have this My hot water is not running How do i get the hot water running again
@AllenHart9992 жыл бұрын
Thank You
@farooqahmed81182 ай бұрын
Can I have the link please
@jimmaxwell22598 ай бұрын
After finishing the adjustments with the chimney sweep function button, do you press the service menu key once or hold for 10 seconds to get out of that menu? Thanks
@AllenHart9998 ай бұрын
I would need to check instructions now, i haven’t t seen one for years.
@jimmaxwell22598 ай бұрын
@@AllenHart999 Its fine mate, found the info on another video. Regards.
@jasminewhittaker89193 жыл бұрын
How do you use the time dial?
@AllenHart9992 жыл бұрын
Thank You
@michaelconstantinides19393 жыл бұрын
Great video how do I turn up water temperature on my worcester cdi classic
@AllenHart9992 жыл бұрын
is it a combi?
@michaelconstantinides19392 жыл бұрын
@@AllenHart999 yes it is
@AllenHart9992 жыл бұрын
@@michaelconstantinides1939 Turn the dial on the front? Thanks.
@michaelconstantinides19392 жыл бұрын
I have on full temp
@AllenHart9992 жыл бұрын
@@michaelconstantinides1939 Maybe you have an issue with the boiler such as a blocked plate heat exchanger? Thanks.
@chazzdposh8 ай бұрын
Hi, how do you re-ignite the boiler?
@AllenHart9998 ай бұрын
Just turn it on.
@melanieeaton26262 жыл бұрын
I wonder if anyone can help...our reset button flashes and the number on the display gets very low, so we reset and everything gets back to normal -the number goes up to 60ish ,but then the number keeps dropping again... any ideas anyone?
@ENMW20112 жыл бұрын
It's broke mate
@lilynorstrand57008 ай бұрын
I’m still confused about having my heating on. If I would like my house to be set at 18°c how should I do that… I’m not really understanding 60 kW that makes any sense… 😢
@AllenHart9998 ай бұрын
Do you have a room thermostat?
@blessedmaris78062 жыл бұрын
Thanks so much
@alondon94213 жыл бұрын
Why Worcester is so complicated? Who agrees??
@AllenHart9992 жыл бұрын
Thank You
@thornhillplumbing Жыл бұрын
Why is none of this information in the service manual?
@jaydunstan1618 Жыл бұрын
Yes.
@mihaela12s2 жыл бұрын
How do i setup to have hot water all the time?! It only works sometimes … not sure how was set
@AllenHart9992 жыл бұрын
If its a combi it should work when you run the tap. Thanks.
@AllenHart9992 жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@mihaela12s2 жыл бұрын
Got it sorted , many thanks !
@AllenHart9992 жыл бұрын
@@mihaela12s That’s great news. Thanks.
@jaydunstan1618 Жыл бұрын
The manuals are as clear as mud.
@aryansx3 жыл бұрын
How can I join your group training
@AllenHart9993 жыл бұрын
facebook.com/groups/Gas999
@discobiscuits55644 жыл бұрын
Why does Worcester not put a 4inch hole on their templates