In this video I show some easy steps you can take to check if your Freon is low in your air-conditioning system. if your air conditioner is turned on but the air is warm coming out the vents this video may help you. If you are concerned that the Freon level in your air conditioner might be low this video can help you out. If you feel that your air conditioner is not working correctly this video may help you out.

Пікірлер: 37
@jordanferguson4158
@jordanferguson4158 2 ай бұрын
My suction line isn't cold or sweating and the air coming from the fan is cool.. thanks for the help.
@checkitout2468
@checkitout2468 2 ай бұрын
Can you hear the compressor running?
@Lastchance2030
@Lastchance2030 2 ай бұрын
@@checkitout2468 no
@illwillbo
@illwillbo 2 ай бұрын
@@checkitout2468I actually have the same issue as the original poster almost. My suction line gets ice cold and sweaty for a few seconds then goes to basically room temp after a few seconds. The hvac guy said the Freon levels were good according to the gauges. He’s suspecting an issue with the compressor even though we can hear it running. Thoughts?
@GoingNowhereFastBFL
@GoingNowhereFastBFL Ай бұрын
So over the last few weeks we've been having an air conditioner that seems to struggle to get below 79°. This morning it was 84 in the house and I turn the air conditioner on and the temperature out of the vents was 63°. So I would say that that's within a good range. Later in the day we noticed it still wasn't cooling and I went out there and checked and the compressor was off but the fan was running. So we shut down the system gave it a rest and I started to back up and it ran but the temperature coming out of the unit when the house is still luckily 84 was about 72 for a while and now it slowly been dropping and is about 67° which is not as good as before and below the 16 to 22° difference. I'm an electrician and often it's actually the run capacitor that fails. My understanding is that if it just sort of shuts off randomly and struggles it could be the run capacitor which I have a replacement that I could throw at it. But this unit every few years needs freon which means I'm sure it has a small leak. We've never had the money to be able to fix it I'm always either out of work and now I had two strokes so I'm not even working and this has to happen now. There's no ice build up on the line outside. And this morning when I noticed it wasn't cooling despite the cool temperature coming out I actually tore apart it's a split system so inside I cleaned out the coils but there was no ice buildup there was a little bit of mud and hair and stuff in there from dirt and I cleaned it all up nice and clean but in the past when it's low I've seen ice build up there restricting flow out of the vents but that does not seem to be a problem either. This almost would indicate to me that it is not a freon problem this time. I suspect I don't know when the compressor shut off potentially due to the run capacitor and we're in bed and it's just running and running. But there's no ice buildup and it's kind of randomly shutting off and not cooling. The amperage appears balanced no unusual voltage or anything like that. And as I sit here right now I just heard the compressor go out again but the fan is running outside so I think I'm going to throw a run capacitor at it right now and see if that helps Any ideas or suggestions on this?
@checkitout2468
@checkitout2468 Ай бұрын
good details, my friend. Change out the capacitor since you already have one on hand. Shouldn’t take more than 10 minutes. With that said I’m not sure that that’s your problem. when your system does run is the suction line/thicker copper line cold and have condensate on it? I’m guessing you’re low on Freon again. The majority of Freon leaks come from one of two places. The service valves or the service Schrader valves. be sure that the service valves are fully opened. Also make sure that the caps that go on the Schrader valves are closed tightly. You might even consider putting some Teflon tape on those brass caps. how old is your system? If your suction line is not getting ice cold, when the compressor is running, you probably need more Freon. Ask the technician if he will help to lock down those caps nice and tight for you. Again, Teflon tape helps a bunch. Good luck, my friend! Fingers crossed for you.
@dailodai9586
@dailodai9586 Ай бұрын
so if its not warmer than outside air, what does it mean?
@poundermonster
@poundermonster Ай бұрын
Can I relocate an AC unit condenser without draining the Freon
@maverickperson5443
@maverickperson5443 Жыл бұрын
Troubleshooting my HVAC system as AC is not working - have tested everything and no issues with compressor. Outdoor unit fan works, seems like compressor is not. Changed the capacitors(start and run), compressor pipe got cold for a few mins and then nothing(no condensation and not any more cold). Drain switch is not tripped, trap has been cleaned too. Thermostat is sending voltage(24VAC) and contactor is working well too. Any idea why compressor is not working and line is not getting cold? Thank you.
@yuyuyu9029
@yuyuyu9029 20 күн бұрын
New unit lol
@everfragoso-qo1qb
@everfragoso-qo1qb 17 күн бұрын
Try putting a hard start kit thats for a compressor is its not working it help it turn on and fet cold again u say u hear it turn on you never know try that first bfor buy a new ac unite!!!
@everfragoso-qo1qb
@everfragoso-qo1qb 17 күн бұрын
Ir u habe a leave check for low pressure
@johnnymata523
@johnnymata523 12 күн бұрын
I check the line and it is not extra cold it is just fresh cold. I can get the house to go below 80 only at night I am able to reach my set point 77. Will this be a low refrigerant?
@checkitout2468
@checkitout2468 11 күн бұрын
It’s possible that it is from low refrigerant. However, it could also be a dirty evaporative coil, dirty condensing coil, dirty filters, etc. check the easy stuff first.
@brooklyn7983
@brooklyn7983 Жыл бұрын
Blessed, What If The Air Is Coming Out Cold From The Outside Fan?
@checkitout2468
@checkitout2468 Жыл бұрын
It could be a few things, but the air conditioner is definitely not working correctly. Make sure your filters are clean, if not, it might be time to call the pro.
@brooklyn7983
@brooklyn7983 Жыл бұрын
@@checkitout2468 Thank U
@vyger6336
@vyger6336 Жыл бұрын
Trying to troubleshoot my AC.....Suction line is cold and sweating and hot air is coming from fan on outside condenser but I still only have a 3 - 5 deg. drop in return air/temperature in my house ? I have flushed/cleaned the coils on the condenser but that didn't help.I checked the evaporator coil and it looks clean .I change the filter on the return regularly ..My unit is maybe 15 YRS old and the only thing I can't check is the Freon because I no longer have a set of gauges. I used to work as an HVAC Tech mostly heating and some A/C but that was 25 yrs ago and I have forgotten most of what I learned LOL. Am I missing something other than the Freon.
@checkitout2468
@checkitout2468 Жыл бұрын
Consider buying a cheap temperature air gun to determine how cold is the air coming out of the registers? Put your hand up to each register. How’s the volume of air? I’m wondering if some of the ductwork came apart in your attic or maybe dampeners are closed?
@vyger6336
@vyger6336 Жыл бұрын
@@checkitout2468 Thanks for the reply.I have checked the air coming from the ceiling (vents) and it is lower than the temp outside but not much maybe 4 deg.and it should be more of a drop in temp.. I checked the attic and all the flex duct is connected .I do have to balance the ceiling vents as my someone else did it and it looks like he opened ever one wide open...like the one in the bathroom does not need to be wide open ...I'll keep at it Thanks again...
@brentpalmer2577
@brentpalmer2577 2 ай бұрын
@@vyger6336 is the compressor running continuously if so you are low on freon
@wkrp10splayer19
@wkrp10splayer19 Ай бұрын
if your delta temperature is only 5F like you say: you need a service call. it *could* be that you are low on refrigerant, possibly because of a slow leak. a typical delta T is 20F. if the large refrigerant line coming from you compressor, as seen in the video, is not icy cold and sweaty then that is no good - service call is needed
@knoxtrail5412
@knoxtrail5412 3 ай бұрын
Good video so my line is not cold and the fan is blowing cool air outside Freon issue or condenser issue?
@checkitout2468
@checkitout2468 3 ай бұрын
Good question. Can you tell if the compressor is running? Most common reason for not to be running at this point would be a capacitor issue. Second, most common reason compressor issue. Third most common reason would be low or out of Freon. Usually If your system is low or out of Freon, there’s a leak.
@knoxtrail5412
@knoxtrail5412 Ай бұрын
@@checkitout2468 ty
@LygerTheCLaw
@LygerTheCLaw Ай бұрын
refigerant, not freon. instructors used to beat that into us at school.
@checkitout2468
@checkitout2468 Ай бұрын
Yes. However, this video if for the average home owner… they will likely think of refrigerant as “Freon”. 👍😎
@GoingNowhereFastBFL
@GoingNowhereFastBFL Ай бұрын
That looks like a Bryant
@mariagarcia3928
@mariagarcia3928 2 ай бұрын
I replaced the capacitor but the suction line still not sweating and of course not cold air inside the house , what could it be ?
@checkitout2468
@checkitout2468 2 ай бұрын
Can you hear the compressor coming on?
@manuelsalgado8510
@manuelsalgado8510 Ай бұрын
Same issue here , compressor seems to be working but air is not coming cooling inside the house, your thoughts?
@paulheard2370
@paulheard2370 Жыл бұрын
💪🏾💪🏾
@tbone6354
@tbone6354 3 ай бұрын
My wife says its a good idea is to add 50ml of sulphuric acid to the compressor before regassing
@brandongibson2185
@brandongibson2185 2 ай бұрын
Bruh
@wkrp10splayer19
@wkrp10splayer19 Ай бұрын
no
@poundermonster
@poundermonster Ай бұрын
Can I relocate an AC unit condenser without draining the Freon
@ghosthunter5100
@ghosthunter5100 18 күн бұрын
No. In order to Relocate AC condenser, refrigerant must be recovered from system. This would involve other things like relocating the line sets etc. big project which would require a hvac technician to do.
How to Check AC Freon Level
16:52
Word of Advice TV
Рет қаралды 2,1 МЛН
#1 Problem & Quick Fix with Central Air Conditioning Not Cooling
8:53
Silver Cymbal
Рет қаралды 4,2 МЛН
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 44 МЛН
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН
Gli occhiali da sole non mi hanno coperto! 😎
00:13
Senza Limiti
Рет қаралды 17 МЛН
❌Разве такое возможно? #story
01:00
Кэри Найс
Рет қаралды 2 МЛН
How To Add Refrigerant To Air Conditioner
22:08
Word of Advice TV
Рет қаралды 1,8 МЛН
3 Things HVAC Contractors Don't Want You To Know About.
13:17
The DIY HVAC Guy
Рет қаралды 2,2 МЛН
How To Add Refrigerant To Your Air Conditioner R410A & R22
10:15
The DIY HVAC Guy
Рет қаралды 741 М.
How I Add Refrigerant to an Air Conditioner
10:20
Fox Family Heating and Air Conditioning
Рет қаралды 379 М.
AC LOW on Refrigerant! How To Know!
7:16
HVAC Guide for Homeowners
Рет қаралды 83 М.
Goodman Air Conditioner Runs but Not Blowing Cold
5:48
Lex Vance
Рет қаралды 821 М.
Replacing capacitor on outdoor condensing unit. #diy #hvac
0:57
The Regular Network
Рет қаралды 195 М.
Low Refrigerant? Freon Leak? Check This First!
7:02
Sam
Рет қаралды 431 М.
Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps, Tips!
27:56
AC Service Tech LLC
Рет қаралды 1,5 МЛН
How To Diagnose A BAD Compressor | HVAC Troubleshooting
9:46
Quality HVACR
Рет қаралды 183 М.
小丑把天使丢游泳池里#short #angel #clown
00:15
Super Beauty team
Рет қаралды 44 МЛН