In this video, we take a look at how to test a pool pump motor capacitor with a multi-meter. If your pool pump motor makes a humming sound when you try to turn it on, then following these steps can help you determine if you need a new capacitor or a new motor.
SUBSCRIBE for FREE swimming pool care and maintenance videos
every week: bit.ly/SubscribeINYO ****
VISIT our blog for weekly swimming pool tips, tricks, and more! bit.ly/InyoBlog
SHOP at our online store! bit.ly/InyoPools
LIKE us on FACEBOOK! / inyopools
FOLLOW us on TWITTER! / inyopools
FOLLOW us on INSTAGRAM! / inyopools

Пікірлер: 27
@poolmotorrepairguyFL
@poolmotorrepairguyFL 2 жыл бұрын
Jay the Florida pool pump motor bearing repair guy When Service Calls Longwood approved ! that was good info 👨‍🔧IPool
@ronaldedwards2465
@ronaldedwards2465 Жыл бұрын
Good video Thank-you
@StepUnclesStepCousin
@StepUnclesStepCousin 2 жыл бұрын
I’m a pool tech and see this issue all the time. I will get a volt meter that can test capacitors. Very helpful. Thanks!
@Inyopools
@Inyopools 2 жыл бұрын
Glad it helped!
@donhorvat1931
@donhorvat1931 10 ай бұрын
😀Thank you, you guys rock. Motor (~$600), the capacitor was $14 and available locally. (5 minutes 2 screws) I would have ordered it from INYO, but time was important in the case.
@Inyopools
@Inyopools 10 ай бұрын
The best kind of money is saved money. #Facts 😃
@freddurst4420
@freddurst4420 Жыл бұрын
Nice job and great video !!
@Inyopools
@Inyopools Жыл бұрын
Thank you very much!
@harryvon9275
@harryvon9275 24 күн бұрын
If my capacitor is rated 124-148 and I am getting 152, is that close enough or does it need to be replaced? It does not have a tolerance % printed on body.
@keithfadden7316
@keithfadden7316 Жыл бұрын
I found a flaw that caused the pump to burn. The yellow wire from what I believe is the starter cap caught on the flywheel. Luckily I was standing next to the pump and turned it off in time. I repaired it by soldering the wire back and added tie wraps to prevent a repeat. I just wanted to make you aware of this because it could happen to any pump and if the tie wraps were added in the factory, it could prevent this. Had I not been there, there would have been a fire. I have pictures if you are interested.
@mattsarnelli954
@mattsarnelli954 Ай бұрын
Thanks! Definitely a helpful video! Now, I have to see if the capacitance result being higher than the reference range is ok. Mine is 200-240 and the test shows it at 260?? Margin for error, perhaps.. 🤷🏻‍♂️
@Inyopools
@Inyopools Ай бұрын
There might be a +/- 5%; sometimes it is 6% or 10%; that would explain the difference.
@bigfish2544
@bigfish2544 Жыл бұрын
I have the exact capacitor in your video. Its reading 116. So im assuming it needs to be replaced??
@Inyopools
@Inyopools Жыл бұрын
If your capacitor is rated as 124 - 149 MFD like the one we show, then yes, you would need to replace it. Start Capacitor, 124-149 MFD - BC-124 - www.inyopools.com/Products/07501352014032.htm
@MurbyD.HealthTalk-vj3bk
@MurbyD.HealthTalk-vj3bk 5 ай бұрын
KI have a pump in which the start capacitor emits smoke as soon as I turn the power on. Replaced the capacitor , it does the sma thing. What coul be the cause?
@Inyopools
@Inyopools 5 ай бұрын
Your capacitor seems to be overheating, so I would presume there is an issue with the circuitry. My guess would be something is causing overcurrent. I suggest having a licensed electrician troubleshoot the circuit.
@rickchapman2733
@rickchapman2733 9 ай бұрын
My Pentair pump stopped working and nothing shows on the display either. A tech checked it and said there is power going to the unit so it’s not electrical. Would a bad capacitor cause these symptoms? Thx.
@Inyopools
@Inyopools 9 ай бұрын
When you say "display" are you referring to a IntelliFlo's motor mounted control/timer?
@thaddeusjohnson9109
@thaddeusjohnson9109 2 жыл бұрын
My pump is making a kinda loud noise but its working it didn't use to make that noise but water is flowing and the pump running. what's wrong with the pump
@Inyopools
@Inyopools 2 жыл бұрын
The most common cause would be bearings that are beginning to fail. The motor will continue to get louder until eventually, the shaft seizes up. The bearings can be replaced, if you are handy and have the correct tools. Most pool owners replace the motor once the noise gets too loud.
@BackpackandGear
@BackpackandGear Жыл бұрын
I have a well pump that won't start and I purchased a start capacitor that goes on the outside of the motor since the original capacitor tested at 205 micro farads when it should be in the range of 161-193 micro farads. The new capacitor tested at around 194 micro farads. The motor still won't start and just hums. Should the new capacitor be in the range or does it mean that it is bad being outside the range by just 1 micro farad? I was planning soon to open the end of the motor to see what is inside. I did not realize that there could be another capacitor. I just assumed the capacitor on the outside was the start capacitor. Maybe it is not!
@commieslayer8218
@commieslayer8218 Жыл бұрын
I had also not starting motor with run capacitor bad, start cap was good at the end of the motor shaft but run cap failed and didn't kick in. Did you try to spin the shaft by finger? Sometime the impeller gets clogged or the shaft in that area sticks in on older motors. I don't have burnt winding very much cause there is a thermal cutoff protection and the system is frequently turned off by the customer if it doesn't run.
@etmeyutub
@etmeyutub Жыл бұрын
I can't tell what that symbol is you are turning your meter too. Am I blind? I don't recognize it. It does not look like I have that on my meter. Can someone explain?
@Inyopools
@Inyopools Жыл бұрын
The meter you're using may not have the ability to test capacitance.
@etmeyutub
@etmeyutub Жыл бұрын
@@Inyopools yep. figured that out since the question
@jackietaylor5165
@jackietaylor5165 2 ай бұрын
What if there is no humming noise when u turn it on ...pump does not come on... silent
@bradolson3510
@bradolson3510 21 күн бұрын
Bad breaker?
How to Fix Pool Pump Capacitor
11:47
Mark Fauntleroy
Рет қаралды 392 М.
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 26 МЛН
DAD LEFT HIS OLD SOCKS ON THE COUCH…😱😂
00:24
JULI_PROETO
Рет қаралды 16 МЛН
MISS CIRCLE STUDENTS BULLY ME!
00:12
Andreas Eskander
Рет қаралды 18 МЛН
Unclog Your Pool Pump with This One Simple Trick!
8:36
Hallmark Pool Supplies
Рет қаралды 108 М.
How to Test a Capacitor
4:39
R.C. Worst & Co., Inc.
Рет қаралды 249 М.
how to test a RUN or START CAPACITOR the CORRECT way
7:35
Craft Customs
Рет қаралды 850 М.
Above Ground Pool Pump Won't Start or is Humming & How to Fix It
6:16
Above Ground Pros
Рет қаралды 1,3 МЛН
How to Tune Your Pool Skimmer
8:01
Swimming Pool Science
Рет қаралды 749 М.
Pool Motor Humming not starting. Replacing a start capacitor.
4:59
Pool Technicians
Рет қаралды 96 М.
How to Check a Pool Pump Capacitor.
3:17
True Light Pools, LLC
Рет қаралды 55 М.
Motor or Compressor Won’t Run? Capacitor Test, Troubleshooting
4:27
RepairClinic.com
Рет қаралды 2,6 МЛН
Changing Your Pump Capacitor-Humming Pool Pump
4:40
KrossberPools
Рет қаралды 88 М.
Finger Heart - Fancy Refill (Inside Out Animation)
00:30
FASH
Рет қаралды 26 МЛН