No video

How to test the Hall Effect Sensor or position sensor in a washer.

  Рет қаралды 122,311

Paramount Repair

Paramount Repair

Күн бұрын

This is a bench test of a rotor position sensor also known as a Hall effect switch. This sensor is used on most direct drive washers.
Power supply = www.amazon.com/...
Www.paramountrepair.co

Пікірлер: 59
@magic.marmot
@magic.marmot 15 күн бұрын
Excellent knowledge. I'm diagnosing a Fisher-Paykel throwing an RPS sensor fault.
@gustavorodriguez412
@gustavorodriguez412 6 жыл бұрын
Indeed helpful. I will certainly use this on certain errors. You can probably use a 9 volt battery to power the sensor on the field.
@washerdryeradvicechannel8041
@washerdryeradvicechannel8041 2 жыл бұрын
Exactly
@carguy1312
@carguy1312 Жыл бұрын
Knowing what should be at each pin is most of the problem - not sure if there’s a place to find that information??? This was extremely helpful. Thank you!
@RAMZABAR
@RAMZABAR 4 жыл бұрын
Great vid. It's thank to you and others like you that make KZfaq such a great place for info/help. Thanks again.
3 жыл бұрын
You video was instrumental to diagnose my LG hall sensor malfunction and repair. Thank you so very much!
@chrisecarius1837
@chrisecarius1837 2 жыл бұрын
Simple and easy to follow troubleshooting
@maxwillis3548
@maxwillis3548 4 жыл бұрын
Great Video, a big thank you. Le error on my machine led to a faulty sensor with your guidance. Fitted a new one and all is well. Thanks again.
@novalight8325
@novalight8325 2 жыл бұрын
Question, can the sensor accept more than 10 volts? Can the voltage be from 10 to 15 volts? Will that voltage damage it?
@DavidLopez-wy6xz
@DavidLopez-wy6xz 2 жыл бұрын
I found 5 to 1= 10.36 5 to 2= 19 5 to 4= 20 4 to 1 = 10 4 to 2 = 00 I already ordered, the patrt, ends 2002 A The washer ,..do not give codes, starts like spinning, and water pump, on and on, Thank you , waiting for the part GRACIAS, GRACIAS,
@rbrmcmb481
@rbrmcmb481 2 жыл бұрын
Thank You! Thumbs Up
@davedave2109
@davedave2109 4 жыл бұрын
Thanks for the video. Mine just like part sample #1 open 5 to 2. Done. part ordered thank you for your help
@amandachiu8462
@amandachiu8462 3 жыл бұрын
Excellent Video! Thanks!
@jerrysmith372
@jerrysmith372 4 жыл бұрын
I'm repurposing a drive motor for another use. My BLDC controller (manual is in Chinese) has H+, H-, HU, Hv, HW for hall sensor input. Can I use the factory hall sensor for my controller or do I need 3 separate sensors? I have sensors if need be, but the factory sensor would be a cleaner looking install. How would you recommend wiring up the factory sensor?
@olaoyesamson5363
@olaoyesamson5363 3 жыл бұрын
Thanks sir we'll like you channel sir
@davidlight2224
@davidlight2224 4 жыл бұрын
Very helpful, thank you, I'm gonna connect mine to the power supply and test it,, because i dont get 10K ohms between 2 and 5 so most likely bad
@thomo421
@thomo421 4 жыл бұрын
Hi I have a washing machine 7.5kg Fisher & Paykel top loader, I can hold the agitator with my hands when its going and stop it from moving the motor has no torque would a rotor position sensor cause this? any help would be appreciated. Good video
@peterjoseph7486
@peterjoseph7486 2 жыл бұрын
Thank you for this Video, especially the Test part, I tested my LG sensor with the Voltmeter, the readings are OK, but the Washing Machine still cannot spin. Can I have a faulty sensor with correct readings???
@washerdryeradvicechannel8041
@washerdryeradvicechannel8041 2 жыл бұрын
Noop if you follow the hall procedure. More likely your inverter will be damaged.
@I-AlphaLogic-I
@I-AlphaLogic-I 3 ай бұрын
@@washerdryeradvicechannel8041 Love the content on your channel! Do some english stuff man! :)
@alchemy1
@alchemy1 2 жыл бұрын
It is not clear unless I missed something. To start with before you approached the hall with the magnet, obviously it showed voltage ( rooughly 10 volts). Then when you approached the magnet against the hall, it erased the voltage. This is meaningless. By default there should be no voltage to my understanding. It is the presence of the magnet that should separate the charges in the sensor and cause voltage to appear. And up on second approach it should erase it. So there are three states or so it appears. 1. No magnet present ( should imply off state) Because there can only be two states. Either off or on. 2. magnet present ( on state) 3. Magnet present again. return the hall back to the first state ( off state)
@tinysousou
@tinysousou 2 жыл бұрын
Great video man but have a question i want to use the inverter direct drive motor in on /off way not on washing machine do i need to use the hall sensor and why they use the hall sensor in the DD motor?
@genarocabrera2869
@genarocabrera2869 3 жыл бұрын
Sooo useful video, thanks man!
@ashokkumarmotwani5192
@ashokkumarmotwani5192 6 жыл бұрын
What is the volt goes to stator after controller
@Nuttavoot
@Nuttavoot 3 жыл бұрын
I got 0 and 10V from pin 1 but 0 and 8V from pin 2, hope replacing it will solve the fault.
@Alprofight
@Alprofight 8 жыл бұрын
I appreciated your electrical test, TKS i was looking for that! Good Info!
@unknown2day2
@unknown2day2 5 жыл бұрын
Great video man!
@DavidLopez-wy6xz
@DavidLopez-wy6xz 2 жыл бұрын
I will try the 9 v Battery, and themagnet, voltimeter
@rickeykeeton71
@rickeykeeton71 4 жыл бұрын
What are the symptoms of a faulty sensor?
@jerrygarcia7747
@jerrygarcia7747 2 жыл бұрын
And to test the bad part, what will the reading show? you tested a new one correct & do i need a power supply to test it? I get OL with the new & old part.
@therealrollaz
@therealrollaz 3 жыл бұрын
Loved this video, but I have W10178988 part, do you know which pins to test on that one and what numbers I should get?
@mathieubrouillette5835
@mathieubrouillette5835 2 жыл бұрын
Same here, I have 6 pins RPS W10178988 and don’t know which one to test and what number to expect.
@therealrollaz
@therealrollaz 2 жыл бұрын
@@mathieubrouillette5835 so I tested all of them and then ordered a used one. The one I got tested nearly the same and of course didn’t fix the issue. Turned out my issue was a bad capacitor
@therealrollaz
@therealrollaz 2 жыл бұрын
@@mathieubrouillette5835 I still have the extra one and can share my numbers with you if you want
@therealrollaz
@therealrollaz 2 жыл бұрын
@@mathieubrouillette5835 holding the part with the arrow on top and pointing away from you. The pins I’ll number 1,2,3 on top and 4,5,6 on the bottom. 1 and 6 = 11.3k 2 and 3 = 1.5k 2 and 4 = 1.5k 2 and 5 = 1.5k 3 and 4 = 3k 3 and 5 = 3k 4 and 5 = 3k All the rest were OL
@mathieubrouillette5835
@mathieubrouillette5835 2 жыл бұрын
​@@therealrollaz Thx for sharing! I get similar numbers so I assume the sensor is ok. I've disassembled it and re-installed and the error code F51 disappeared ... I let you know if it let me down again and need to replace it.
@Bertzservice
@Bertzservice 7 жыл бұрын
channel Bertzservice youtube Brazil
@shanecody1737
@shanecody1737 7 жыл бұрын
What are the symptoms of a faulty position sensor on the washer?
@paramountrepair3129
@paramountrepair3129 5 жыл бұрын
Shane Cody, you might have rpm faults. But do continuity test between the board and the sensor. Broken wires are common.
@theblade9024
@theblade9024 7 жыл бұрын
Thanks. Very helpful.
@olaoyesamson5363
@olaoyesamson5363 3 жыл бұрын
Thanks sir
@shaileshparab3485
@shaileshparab3485 3 жыл бұрын
Do we see same hall effect change for pin 3 as we see for pin 1 & 2 ??
@xicath
@xicath 3 жыл бұрын
exellent! so thats called sensor, i just exploded the part of the motor and do know what this pin things do
@tee1922
@tee1922 3 жыл бұрын
What are you swiping and bumping with?
@kimtinal9353
@kimtinal9353 4 жыл бұрын
is this method work with samsung washing machine?
@DavidLopez-wy6xz
@DavidLopez-wy6xz 2 жыл бұрын
Do you have more videos ?
@randyrodriguez99
@randyrodriguez99 7 жыл бұрын
I hate two questions why is only 10 VDC? And your power supply could be set to both A/C and D/C ?
@paramountrepair3129
@paramountrepair3129 5 жыл бұрын
10 volts is what the sensor operates at, and no. It’s a dc power supply only.
@MrPounal
@MrPounal 7 жыл бұрын
i have a samsung with 4 connector why is it only two hall and not three isnt it a three phase motor so what trigger the third one?
@paramountrepair3129
@paramountrepair3129 7 жыл бұрын
kevin pounal Hey Kevin, Im not sure if I understand your question. But the Hall effect sensor is only used to detect the movement of the stator of the washer.
@judahappliance
@judahappliance 3 жыл бұрын
where did you get the power supply
@paramountrepair3129
@paramountrepair3129 3 жыл бұрын
Amazon
@maxwillis3548
@maxwillis3548 4 жыл бұрын
Max
@shaileshparab3485
@shaileshparab3485 3 жыл бұрын
Do we see same hall effect change for pin 3 as we see for pin 1 & 2 ??
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 108 МЛН
Fortunately, Ultraman protects me  #shorts #ultraman #ultramantiga #liveaction
00:10
Challenge matching picture with Alfredo Larin family! 😁
00:21
BigSchool
Рет қаралды 40 МЛН
How To: LG/Kenmore Washer Rotor Position Sensor Switch 6501KW2002A
6:28
AppliancePartsPros
Рет қаралды 347 М.
How To: Samsung Rotor Position Sensor DC31-00098A
7:47
AppliancePartsPros
Рет қаралды 46 М.
LG or Kenmore Washer Won't Run and Makes Noise - Solving the LG Error Code
10:08
Bens Appliances and Junk
Рет қаралды 16 М.
Secrets to Solving LG Washer LE Error: Stator & Sensor Guide
13:37
Online Appliance Tech
Рет қаралды 10 М.
How to Repair hall sensor washing machine lg
15:17
Hari service elektronik
Рет қаралды 80 М.
Why Is He Unhappy…?
00:26
Alan Chikin Chow
Рет қаралды 108 МЛН