How to wire a Honeywell BDR91 Wireless Relay Box (230v low voltage wiring)

  Рет қаралды 58,322

MWPHS

MWPHS

Күн бұрын

Richard goes through how to wire a Honeywell BDR91 Wireless Relay Box as a Boiler Demand Relay.
You can use the same principle to wire to motorised zone valves (B terminal to brown wire of motorised zone valve will provide a 230 volt switched live to the valve).
If you need a new Honeywell BDR91 Wireless Relay Box, we sell these on MWPHS.co.uk - mwphs.co.uk/pr...
**PLEASE NOTE** There is serious danger of injury with any 230 volt electrical product. If you do not know what you are doing, please contact a suitably competent person.

Пікірлер: 29
@davidwilliams6334
@davidwilliams6334 2 жыл бұрын
Thanks, Richard - just about to replace an old Danfoss wireless thermostat with the Honeywell set and your wiring instructions were bang on! Brilliant, much appreciated, mate!
@user-sq9cp8qf4r
@user-sq9cp8qf4r 10 ай бұрын
You beauty - used to connect 550W IR panel and round thermostat. Resideo help desk seemed more interested in avoiding any liability than offering guidance
@MWPHS
@MWPHS 10 ай бұрын
No problem, glad my guidance helped! :)
@Roy1
@Roy1 5 жыл бұрын
thank you for the explanation. Pity the instructions don't mention the link wire for 240 v
@suheilhanna873
@suheilhanna873 Жыл бұрын
Very informative
@AdrianTuhut
@AdrianTuhut Жыл бұрын
I needed to do one more thing in order to make it work: add a bridge between the two L's. On my BDR91T they are not internally connected.
@MWPHS
@MWPHS Жыл бұрын
You do not need to bridge the two L's normally... As long as the BDR91 is not faulty, it will be linked on the PCB.
@duckula67
@duckula67 9 ай бұрын
Brilliant thanks. That helped me get it right.
@MWPHS
@MWPHS 9 ай бұрын
Glad it helped... If you haven't already, please like the video! :)
@micallef87
@micallef87 Жыл бұрын
I’m confused about the live link wire because in the manual page 41 it has the link wire connecting the two lives and room stat wires (2 of) running to A and B for a permanent live combi. Whereas you’re linking a live to A.
@MWPHS
@MWPHS Жыл бұрын
The ‘A’ terminal is the ‘common’ connection terminal on the BDR91 and ‘B’ is the ‘normally open’ terminal. In electronic circuits if you attach any voltage to a relay, it is normally attached to the ‘common’ terminal, hence on the video a 230v feed wire has been attached to ‘A’ from the second ‘L’ terminal. Please note that the video illustrates a 230V switching circuit. If the boiler is extra low voltage switching, you wouldn’t use a link wire from the second ‘L’ terminal and the connections from the boiler would be directly to the ‘A’ and ‘B’ terminal.
@damircengic8136
@damircengic8136 10 ай бұрын
@MWPHS Hi, I have recently purchased a new thermostat from your shop to upgrade my old Honeywell DT90 Thermostat. I have purchased the newer version of the Honeywell BDR91. In my old DT90 I had two wires. A brown wire that went into A (this is the electric wire as it had power) and a black wire that went into B (I assume this one was from the boiler?). And all worked well. How do I know connect the new relay of the BDR91. I tried different options but the reley just does not want to work and the two led lights are just not turning on. Maybe the relay is faulty? Any help would be much appreciated.
@MWPHS
@MWPHS 10 ай бұрын
Just for clarity the BDR91 requires a minimum of 3 wires plus an earth. The BDR91 requires a Permanent Live and Neutral and the switching wire back to the boiler. Some thermostats have two wires (Live and Switched Live), which means the BDR91 won't work as you would be missing the Neutral.
@fincocoffee5335
@fincocoffee5335 10 ай бұрын
Hi we have a Honeywell T3R programmable thermostat to a new Vaillant eco tec pro 28 boiler and we’ve wired it as we have always other boilers but it won’t work? Vaillant have suggested putting a link in like your video but it doesn’t work? Have got any suggestions please?
@MWPHS
@MWPHS 10 ай бұрын
Sorry I don't, as the T3R has a different wireless receiver to this one and I don't know enough about the Vaillant boiler to comment.
@fincocoffee5335
@fincocoffee5335 10 ай бұрын
@@MWPHS thanks for replying anyway my mate - all the best 👍👍
@54321kola
@54321kola 9 ай бұрын
Same problém With viessmann vitodens 111. Port 96 . Exact connections od Boiler and relaY. Attached unkversal Honeywell scheme dobe work … fail
@paulajay6879
@paulajay6879 3 жыл бұрын
Could you let me know how to remove the cover please once it’s on the wall?
@MWPHS
@MWPHS 3 жыл бұрын
Isolate the mains voltage and then insert a large flat bladed screw driver into the slot at the base of the BDR91. This will release the catch which will allow the BDR91 to release from the base and swing open.
@paulajay6879
@paulajay6879 3 жыл бұрын
@@MWPHS fantastic!😃thank you👍🏼
@bumblebee-mygt867
@bumblebee-mygt867 Жыл бұрын
So for a no volt switched contacts. Leave out the live link and connect the A and B to the thermostat zero volt connector on the boiler. These contacts will open and close depending on the thermostat setting . Think this is right. Please confirm
@MWPHS
@MWPHS Жыл бұрын
Yes you are correct. A & B are volt free contacts unless you physically put 230v onto them.
@markjones7025
@markjones7025 3 жыл бұрын
If I am replacing a bimetallic thermostat with this and only have a live and neutral wire to the boiler, how should I wire it?
@MWPHS
@MWPHS 3 жыл бұрын
3 core and earth cable is required. If you only have twin and earth it won’t work. Thermostats using two cores are normally live and switched live, but you still should have a protective earth conductor? If in doubt contact a competent electrician.
@MrPhilsson
@MrPhilsson 3 жыл бұрын
Does it matter which way round the A and B are when you wire them to the "two low vaultage switching terminals" on the boiler?
@MWPHS
@MWPHS 3 жыл бұрын
If it’s low voltage switching, then it shouldn’t matter which way round A and B are.
@AdydeAdy21
@AdydeAdy21 Жыл бұрын
Hellow sir....from boiler i put blue cable to A and brown cable to B,it is ok? Or doesnt matter
@MWPHS
@MWPHS Жыл бұрын
It shouldn’t matter (as long as the blue wire isn’t the ‘Neutral’ of course!) but always good practice to put the voltage feed from the boiler to the ‘common’ terminal ‘A’ and switched feed back to the boiler on the ‘B’ terminal.
@AdydeAdy21
@AdydeAdy21 Жыл бұрын
If i got some wrong,what it can happend? If i inverse A with B?
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 44 МЛН
Smart Sigma Kid #funny #sigma #comedy
00:40
CRAZY GREAPA
Рет қаралды 39 МЛН
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 51 МЛН
Explaining the BDR91 Boiler Relay LED indicators - Resideo
2:51
Resideo Customer Support
Рет қаралды 87 М.
Combi Boiler 2 Heating Zones Volt Free - 24V and Others
12:54
John Ward
Рет қаралды 22 М.
How to wire a room stat
6:01
CP Utility Solutions
Рет қаралды 7 М.
How to Wire a DPDT Relay for Chicken Door
21:05
Will Work For Liberty
Рет қаралды 45 М.
How to find a low voltage short HVAC Basics @EngineeringMindset
9:12
BDR91 ketelmodule toewijzen aan evohome Wi-Fi | Honeywell Home
4:06
Honeywell Home
Рет қаралды 86 М.
黑天使遇到什么了?#short #angel #clown
00:34
Super Beauty team
Рет қаралды 44 МЛН