No video

How To Wire a Hot Tub Pump Motor Correctly The Spa Guy

  Рет қаралды 154,812

Spa Guy

Spa Guy

7 жыл бұрын

hottubpartsofamerica.com/
In this video The Spa Guy shows you How To Read and understand a Hot Tub Pump Motor Wiring Schematic and wire your Hot Tub Pump motor.. Most Hot Tub Pump Motors do not come with a wire so this teaches you how to put the wire on the new motor... Subscribe for More Fun Stuff...

Пікірлер: 158
@ericpeysar2593
@ericpeysar2593 3 ай бұрын
You are the MAN man! Thank you so much for your explanations and all the different manufacturer samples. This was a HUGE help!
@SpaGuy
@SpaGuy 3 ай бұрын
Glad to help!
@rickwagner3797
@rickwagner3797 Жыл бұрын
Very helpful, I’m replacing an old pump with a new one and I now feel confident I’m doing it right. Thanks
@LPRacing12
@LPRacing12 3 жыл бұрын
Just bought 2 dual speed pumps and realized my hot tub has a 1 speed and a 2 speed. I almost freaked out on what to do until I came across this! Your videos are so freaking helpful you have no idea.
@jamesyates5191
@jamesyates5191 Жыл бұрын
Thank you. I paid attention to the old motor wiring but assumed the new motor would have the same arrangement. Your explanation was very clear. Especially all the variations.
@genebopp
@genebopp 4 жыл бұрын
Thanks. You answered my "how does it know" question. The white being hot all the time was exactly what I needed to know.
@ThatsHowIRoll
@ThatsHowIRoll 5 жыл бұрын
Thanks go out to The Spa Guy! I called my manufacturer for tech assistance and they were no help after 40 minutes on the phone Started searching KZfaq and came across The Spa Guy! gave him a call and left a message within a few minutes he called me back and diagnosed and helped me correct the problem over the phone!!!! He is now my Spa Guy!
@SpaGuy
@SpaGuy 5 жыл бұрын
Awesome Glad I could help!!
@danwoodard5884
@danwoodard5884 4 жыл бұрын
Thanks for clarifying the mislabeled colors, this had me confused when trying to wire up a new pump
@coralfallstead3189
@coralfallstead3189 2 жыл бұрын
The place to go with ANY questions about hot tubs. Spa Guy you are awesome, and will buy my parts from you because I know I'll get the right stuff and to help you pay for all this information you put out.
@jijoe4257
@jijoe4257 4 жыл бұрын
HUGE HELP!!!!! Thanks so much , much appreciated
@BrandonWaring
@BrandonWaring 2 жыл бұрын
Very helpful, thanks for making this. Now I have some confidence in what I need to consider when buying and installing.
@markmurphy6498
@markmurphy6498 4 жыл бұрын
Good information. Thank you for sharing!
@joshuadodson6874
@joshuadodson6874 4 жыл бұрын
Awesome info. Just what I needed!!
@jeffwinters7791
@jeffwinters7791 4 жыл бұрын
I have a waterway pump that went bad PF-40-2n22c 2"wetend 230v 2speed got a new one from amazon PF-30-2n22m and it works good the wiring was different but it is running was not sure of the wiring so I seen your video on diagrams thank you!
@dawnfrench8218
@dawnfrench8218 2 жыл бұрын
Thank you so much! You really helped me out alot!
@johnnyb2779
@johnnyb2779 Ай бұрын
this man gets me
@peterdaly2848
@peterdaly2848 5 жыл бұрын
Hi spa guys great video, I live in the UK just a quick question I have a 2 speed motor which has blown so I bought a 1 speed motor and wired it by putting the brown and black ( both 1 and 2 speed wires on previous motor) together but I'm not sure if it will blow the board? Can you please help! Thank you
@jaretsnow6300
@jaretsnow6300 5 жыл бұрын
this was very useful
@marsbars238
@marsbars238 7 жыл бұрын
Thanks for the video. My pump was seized and humming so i bought new pump, installed j & j style connector as shown on old motor red high white common black low. Pump will not even turn on now, showing flo error like before. Doesn't trip breaker, and breaker was turned off when uninstalling and reinstalling pump so shouldn't be fuse. At this point, only thing i can think of would be fuse blown some how.
@individuallywrapped5321
@individuallywrapped5321 7 жыл бұрын
Thought I understood, but im confused. Followed what you said about hooking up the grn, red, blk and wht wires. Have a Marathon 230, I put the red as the hi and black as the low and then you mentioned something about on a Balboa its different. I didnt understand that and I must have also missed what to look for on the motor that tells me its a 2 speed. Anyways,... I hooked it all up. Filled with a garden hose through the filter housing and opened the air valves. Just have no idea if the pumps got primed. I have the filters out. Didnt want them in till I get new ones. turn on the hot tub. Code comes on Pr. prime mode, then goes into std mode and flashes temperature and then std repeatedly. Highest temp was 70 degrees. Then mode changed to Dr. Pressed any button to reset. Then it went to SLP solid and then after a little while, 5 minutes, it went to OHH. I have put in a brand new system from Balboa. I just cant get this tub to function correctly.
@lucasjohnson1467
@lucasjohnson1467 7 жыл бұрын
I have an arctic spa tub. It had yellow pumps, white water I believe, from factory. My pump #2 single speed pump all of a sudden cracked the impeller. So I bought a new wet end and installed it, bang, cracked the impeller again. This time I noticed the pump shaft spinning backwards.. So my local tub place sold me a Galaxy pump. They took the pump power plug off my old pump and put it on new one. I installed the new pump and it was running on low speed instead of high (it is a two speed pump). I never took the cover off to see how it was wired, old J single. I took a pic and sent it to the tech and he said I changed the white and black wire and I never touched it. So I reversed them with the same result. I followed the diagram to wire for high speed using the white as the common because that's what he told me, and when I plugged it in to the controller box it arced out at the box and melted one of the little prongs on the plug. What in the hell is going on??
@zigzaks
@zigzaks Жыл бұрын
Excellent explanation . My Jacuzzi has old controls with contactors and pneumatic switches. Maybe 30 years old. That 110v power on white wire really confused me. JJ plug reversed speed. Replaced motor, but somehow no slow speed(motor OK). Will replace solid state contactor. Maybe this is the problem. Anny suggestions? Does pomp will run low speed without water? Does low speed still runs on 220, or 120. I guess 220 low mps. What component giving lower amps?
@bobbaltin2580
@bobbaltin2580 5 жыл бұрын
Great video.. just missed the set up I have.. A 2 spd century AC motor. Dealer sold it to me to replace the single (high) speed pump that died.. but of course the wiring set up is different.. I only want to hook up to the high speed but it isnt marked as C, H, L as some are. Any help? /Thanks
@dawnfrench8218
@dawnfrench8218 2 жыл бұрын
Spa guy! Have a used royal hot tub. I fixed the leaks and when I turn it on it was making a humming noise I turned the impeller and it was good so I put a new capacitor on it and that didn't fix it so put a new pump on it and it's exact pump that was on there and now it's making same noise but it's kicking off when I turn it on!
@NathanielJames-jk5td
@NathanielJames-jk5td 7 ай бұрын
@Spa Guy can you please help? I have a 1-speed motor in a 2004 caldera utopia geneva hot tub I'm replacing. The wiring diagram on the motor doesn't show where the black and white wires in the tub go. I know which 2 terminals on the motor, but it doesn't say which is which. One has a yellow wire with a black stripe attached to it, the other has a plain yellow wire. I look everywhere on google and can't find anything. This motor cost me $500 I don't want to ruin it by wiring it wrong. I figured out the other 2-speed motor and have wired it fine thanks to this video!
@lizardsza
@lizardsza 4 жыл бұрын
Would you be able to help me with the schematics or advice on how to wire a GC150-2XJ-B motor please. Any help is greatly apreciated. Thank you so much.
@michaelhagens5176
@michaelhagens5176 6 жыл бұрын
Hy spa guy. I have a mother here and don't know if it's a 1 speed or 2 speed. Its says voltage is 230/115 rpm- 3450 amps 8.0/16.0. It looks like its two speed but it only has 3 wires for power. Green, white and black on a amp plug. I need it to be a jj 2 speed plug. Is it possible to wire it like that? My tub is a vita spa l500 series it has two pumps.
@ashleypenaloza7177
@ashleypenaloza7177 7 жыл бұрын
thanks for this video
@SpaGuy
@SpaGuy 7 жыл бұрын
You are welcome thanks for watching.. Spa Guy
@billg7515
@billg7515 5 ай бұрын
Came across your very detailed video and appreciate your efforts. However, your suggested fix didn't quite work. I must be missing a step or two or three. Have a Waterway 48, Model # PF-10-2N11C4. Your video confirmed I had definitely had the pump wired wrong. I had black going to high and red going to low, which resulted in my pump only giving me low speed and a "clicking" sound when I attempt to switch to high with no result. I flipped the two wires, but now I only get high speed and the same "clicking" when attempting to switch to low. What gives? Could it be something else? Shouldn't be the pump since it's brand new. What am I doing wrong? Any help appreciated. Is it safe to assume that if I can't resolve this and leave the spa on high, it will chewing up more electric?
@landondavis2479
@landondavis2479 3 жыл бұрын
Hey Spa Guy. I have a new XP2 jet motor that will not push water. I've tested it off the spa and it turns. Hook it up and it gets loud and trips off. Do I have the pump wired backwards? Black on high, White on Common, and green on ground. What am I missing? Thanks
@steveshuss738
@steveshuss738 2 жыл бұрын
ok i have a old catalina spa i'm going from the older style pump to a newer one and you show my current pump with the diagram that's label H C L but on my old one i have only a black white and green wire with a white jumper wire that i'm assuming is taking place of the red wire? my current old motor is an A.O. Smith my new one is an US motor wish i could post pics hopefully i don't have to purchase a new wiring harness those things are salty..thanks
@JoePate-gx7gl
@JoePate-gx7gl 2 жыл бұрын
I have an older morgan spa... two issues, the second pump is dead and ihave a 110v pump that is in new condiditon - can i use the two speed 220 as my main pump, and the 110v as my second? of course i would need to tie the white lead back to grounding block on GFI. Second, the Gecko controller is in great shape, but the up and down buttons are not working correctly, any way to test? thanks and love your vidoes and help J
@LauraBrook
@LauraBrook 7 жыл бұрын
Thank you Spa Guy! I have an older, 2-speed system, air buttons, with a J+J plug, 230v. You mention that in some of these older systems, the red and black are reversed. Well... I removed the wires from the old pump without taking note of the location for the red and black wires, and there is no schematic on the old motor! So now I'm in a pickle because I don't know if red is high speed or low speed. Is there any way to test this? If I wire it incorrectly, do I risk ruining the motor?
@SpaGuy
@SpaGuy 7 жыл бұрын
Laura Hartzell there is no short term risk of damaging the motor if they are backwards you will overheat the tub.. if it is a digital system when the system first turns the pump on that should be low speed on an air button system the low speed should be the speed that turns off and on with the thermostat outside of timer mode.. Thanks, Spa Guy
@ronkloiber
@ronkloiber 2 ай бұрын
I have a Waterway Exec 56 220v 2sp like you show at 6:55. The pump works fine on low speed but most times when the spa switches to high speed, the pump will kick to high for a second and then stop, or it doesn't try kick to high at all, but there is still 220 volts between 1&2 (Common & High) so something inside the motor is an issue.. Could this be a CAP issue.. and would that be the one on the end (55-75uF) in the plastic casing, or the large one on top of the motor, or the centrifical switch? .. or something else..???
@kathrynschultz9500
@kathrynschultz9500 3 жыл бұрын
Is it possible to wire in a capacitor into my two-speed pump that has a switch?
@oursailingvoyage
@oursailingvoyage 28 күн бұрын
I'm working on my old Caldera with AO Smith 1081 dual voltage. I've got a three conductor wire going to each...BWG. That must mean it's wired for 115?
@markjohnson5116
@markjohnson5116 11 ай бұрын
I replaced my 2 speed pump with a new one and i followed the schematics on each one, and it is wired right acordingto your example in the video. The pumps doesn't turn on, it just clicks when I hit the jet button.
@jeffjohnson8594
@jeffjohnson8594 Жыл бұрын
Hi Spa Guy...I know this is an old video but..my pump 2 on my hot tub...the connection at the plug in the box failed and I had to get a new plug. IT is a J&J plug 3 wire, red black white and ground. I figued I could just get the same plug and put the connections where they were. The black wire is connected to the pump but not connected to the board, is that ok? It is just taped off. The plug was fried. This was a brand new spa, it is as it came from the dealer, but it is several years old. Thanks
@paulzajac3142
@paulzajac3142 2 жыл бұрын
Hi Spa Guy, Great videos. I have replumbed and fixed an old 80s spa based on your videos. Well done. My old spa has a retro fit Spa Builder AP-1400 control/heater (230v). Had an old Magnetek 2 speed pump that kept blowing the start capacitor. Just replaced it with an Emerson 2 speed pump (1 of the pumps in your video). It’s wired correctly but the pump just goes on and off non stop when turned on. I can see water flowing out of the jets but it just cycles and won’t stay on. This happens when its calling for heat or not. I think there is something in the control unit doing this. Any thoughts? Thanks
@sweaterwearingsquirrel9302
@sweaterwearingsquirrel9302 Жыл бұрын
I have this same problem
@JoseTorres-tl1zt
@JoseTorres-tl1zt 4 жыл бұрын
So I think I pug it in the mother broad backwards. It worked for a min then shut down. Do you know what I damaged?
@usecom1
@usecom1 6 жыл бұрын
I have a HotSprings tub and it has 2 blue 2 red and 1 white coming out of the control box. I have a conduit with a red and black a green and a blue and red wire running from a dual gfci panel 30/20 amp ; now what?
@leebeaulieu5276
@leebeaulieu5276 7 жыл бұрын
Good video spa guy, I'm swapping an Emerson motor and putting in a century laser motor, n the new one doesn't have a capacitor......I think.... lol , 2 blue wires and a red wire, am I supposed to swap that in the new motor?
@SpaGuy
@SpaGuy 7 жыл бұрын
I have no idea what you are talking about here.. The wiring is either black, red, white and green or black, white and green... The capacitor set up is different on different motors so that has no bearing on the installation.. Thanks for watching, Spa Guy
@kirkbrown3323
@kirkbrown3323 2 жыл бұрын
Hello I have a crazy question, my dog jump into my tub then jump out. When she jumped out she land on the wire plug that goes it the hot tub 240v. Now my hot tub was only going on the low circulation speed and no high speed. Now I'm hearing a grinding. The tub is on 2 years old a strong spa. The way you are describing this could my dog loosened the red high speed wire. Any help would be greatly appreciated. Thank you very much.
@johnpittman3613
@johnpittman3613 3 жыл бұрын
I bought a new motor and pump. It’s not coming on but it’s getting 120v to red and 120v to black should white wire be getting 120v also?
@jhusk574
@jhusk574 Жыл бұрын
Thanks for the info! One question: When powering these wires for high speed mode are both red and black powered simultaneously? Or does it switch the power from black to red when moving from low to high?
@SpaGuy
@SpaGuy Жыл бұрын
Low speed is usually white and black low speed both hot and then white and red high speed both hot..
@btrizzel
@btrizzel 6 жыл бұрын
I have an arctic spa 04' . Can I hook up a third pump? There is a plug for it but the current fuse/relay is for "heater/pump 3" together so would I need to upgrade the fuse or relay?
@SpaGuy
@SpaGuy 6 жыл бұрын
Juts because not is marked like that does not mean it will operate another pump.. There is a lot more information to that question than awe can go into here.. the main thing is if you are able to add another pump you will have to configure the system, to turn the heater off when the third pump comes on.. Also note if you have a blower it may actually be using the third pump circuit.. Thanks, Spa Guy
@thesearemyadventures6934
@thesearemyadventures6934 Жыл бұрын
Do I need to worry about capacitor when removing old pump?
@xtrememv
@xtrememv 3 жыл бұрын
Hi how I connect a Emerson electric motor model t55cxbhm-901 to high speed
@lyalljollota119
@lyalljollota119 Жыл бұрын
I have a question I replaced my pump motor with one with exact same specs except my motor has 2 capacitors on the motor body. Following the GE Wiring (got from you) The pump turns on and runs for about 4-5min then kicks the main breaker. Pump is not hot but one of the capacitors is very hot. Does the wiring change from 1 to 2 capacitors?
@SpaGuy
@SpaGuy Жыл бұрын
Capacitors do not matter.. Make sure you wired it right..
@hetzalwel1323
@hetzalwel1323 Жыл бұрын
I have a LX 2 speed pump, sadly the control panel button is broken. Can i make a extra switch for the high speed function? My worrie only is that the system will put low speed when i use high speed at the same time.
@hetzalwel1323
@hetzalwel1323 Жыл бұрын
Its a 230 volt system.
@steveneugenefyrehrt1108
@steveneugenefyrehrt1108 6 жыл бұрын
Ok so I had a 230v 8.0 amp Magnetek motor in a Alps Spa that went bad. I found another Magnetek that's 115v 12.4amps . There's no second number on the schematic so I'm guessing it's a one speed motor. I want to wire this as 230v. How do I proceed?
@SpaGuy
@SpaGuy 6 жыл бұрын
Hell Steven, You cannot wire it 230V if it is a 115V pump.. If it is the main pump it is supposed to be a 2 speed so the 115V one speed will not work.. If it is pump #1 a one speed you can use it just move the whole wire to the red AC leg on the board to make the circuit 115V.. Just know the 115V pump will be much more weak.. Thanks, Spa Guy
@pierrelabbe3173
@pierrelabbe3173 3 жыл бұрын
Love. Canada....✌👀🔥☺💯🆗
@nathanmciver6737
@nathanmciver6737 3 жыл бұрын
I just want to cry when I think about this country. All positive though. I will get better
@m.a.4829
@m.a.4829 2 жыл бұрын
Hey, hope you can help. I purchased a pool pump and it has a RED (H) BLACK (C) and YELLOW (L) wires. My power supply is 240V, I only have Red, Black and Ground, how will I wire up the system?
@SpaGuy
@SpaGuy 2 жыл бұрын
There is not such thing was Red , Black and Ground unless someone put the wrong wires in.. If each are 120v hot it would be C to H the polarity does not matter..
@brianmoran5392
@brianmoran5392 3 жыл бұрын
Hi Spa Guy, I replaced one of the pumps yesterday but now during the regular filter cycling of the hot tub, the pump runs at full speed? Did i get the wires switched?
@SpaGuy
@SpaGuy 3 жыл бұрын
Yes it sounds like you did..
@trevorneufeld5038
@trevorneufeld5038 9 ай бұрын
hi, I haven't been able to find out what the name of the plastic part is inside the motor that the leads plug into (green white black red) Mine is cracked and I need to find a new one. Thanks! TN
@SpaGuy
@SpaGuy 9 ай бұрын
That is not a part you can usually buy.. this link is an example of one switch that is available..
@itisbigernie
@itisbigernie 4 жыл бұрын
Can you please clear a confusion? I am putting back a 2-speed pump (Aqua-flow XP2) on a 115V circuit. You mentioned on this video that the Black wire on the 3-wire should be connected to the High speed terminal. But on your one other video where you spin the motor to use as a lathe, the black wire is connected to the Low speed terminal. I take that either way is correct but which is preferable. Sorry, the old wiring before the pump got disconnected was lost.
@SpaGuy
@SpaGuy 4 жыл бұрын
You are confused I never said that.. The black wire is normally Low speed but there are exceptions.. Look at the wiring diagram inside the front cover of the board and it will show you where the pump wiring is and what color wire is low speed..
@itisbigernie
@itisbigernie 4 жыл бұрын
@@SpaGuy Thank you very much for the clarification.
@williambarnicle569
@williambarnicle569 2 жыл бұрын
Have a dead single speed 220, can I replace w a 2 spd ? If so , wiring? Since control is only on n off?
@SpaGuy
@SpaGuy 2 жыл бұрын
Yes just use high speed and you are back running.. We offer pumps on our site.. hottubpartsofamerica.com/pumps-and-related-parts/jet-pumps-complete/
@wpatters1229
@wpatters1229 2 жыл бұрын
I want to run the pump on high speed for about 8 hrs to make sure some fix a leak gets run through all the jet lines. This is a two-speed 240v system. Can I just use a jumper wire from the high-speed connector to the middle/neutral wire to push a full 240 v to the pump until I pull the jumper off. Will this hurt any circuitry on the board?
@SpaGuy
@SpaGuy 2 жыл бұрын
No just switch the high speed and low speed wire temporarily..
@wpatters1229
@wpatters1229 2 жыл бұрын
@@SpaGuy OK but won't that just change the speed when it starts its cycle? I want to run the pump for 6 to 8 hrs to fully circulate the fix a leak product as they suggest. I just want to force the pump on and not let the programming from the circuit board affect the length of time.
@Marketmagicdailypay
@Marketmagicdailypay 4 жыл бұрын
I bought a used Viking hot tub .. Viking spa how do I know what pump to buy to replace it ?
@SpaGuy
@SpaGuy 4 жыл бұрын
You send pictures to the Spa Guy.. parts@htpofa.com
@ftcthomas7849
@ftcthomas7849 4 жыл бұрын
Converting a 240v to 120v. L-60 vita spa. Switched the jumper and changed the setting on the spa side panel to s-0 for 110v operation. Pump goes slow and motor gets hot. Have a P1 fault on diagnosis test. Do I have to rewire the pump? Or install a 120 volt motor pump assy? Please help.
@SpaGuy
@SpaGuy 4 жыл бұрын
If the pump is 230V the tub has to run on 230V if it is 115V it can run on 115v or 230v..
@ftcthomas7849
@ftcthomas7849 4 жыл бұрын
I think what happened the original pump was 230/115v and the after market was 230v installed. So I need to replaced the pump or upgrade the service which will be about the same cost. I am leaning towards 230v gfci load center for better operation. Thank you for your help.
@AhciD
@AhciD 6 жыл бұрын
Question. My pump runs fine on low. When it kicks into high it humms and the board clicks into protection mode. I notice that the low and high wires are both energized at 120v when the pump is on high. I can take the low lead and put it on the high terminal and it runs in high just fine. But if both the low and high leads are connected at the same time and it switches to high it trips out... Any ideas?
@dh3930
@dh3930 4 жыл бұрын
Hey Spa guy, So my old executive 56 two speed motor had a white wire on #1, red wire on #2 and black on (it shows #3 or #4 on the same connector) My new executive 56 has H, C and L instead of numbers. I wired black on L, white on C and red on H. It only has a a single speed and runs on slow only. How should it be wired to get my two speeds back? Thanks. I just watched your video again and noticed you said if it’s 230v the white is hot. So there is is So if my new pump has H,C and L which wires go where?
@SpaGuy
@SpaGuy 4 жыл бұрын
Based on what you said you have it wired right so the issue is not the way you have it wired.. Check for 230 between the white and black for low and the white and red for high.. Spa Guy
@dh3930
@dh3930 4 жыл бұрын
Spa Guy great thanks!
@dh3930
@dh3930 4 жыл бұрын
Spa Guy hello again, I didn’t bleed the air out of the lines when i filled the hot tub. Would this be enough to cause a lower pressure than the older motor even though they are the exact same? Thanks!
@dlhaddix742
@dlhaddix742 2 жыл бұрын
I have a Cal Spa Hot tub with three pumps. Two in the front and one in the back. The back pump needed replacing and I acquired a new motor with four wires. Black, Red, white, and green. However the Cal Spa control panel cable provides only three wires. Black, white, and green. In this wiring scenario, is it white/white, red & black /black, and green/green? Thanks.
@SpaGuy
@SpaGuy 2 жыл бұрын
The answer is in the video.. It is easy use high speed only..
@dlhaddix742
@dlhaddix742 2 жыл бұрын
@@SpaGuy OK! Thanks for the quick reply.
@xtrememv
@xtrememv 3 жыл бұрын
I have a pool pump how I can put it to high speed
@nuckingfuts2012
@nuckingfuts2012 2 жыл бұрын
What happens to a 2 speed pump when the black and the white are switched? It’s suppose to be wired as black is high, red is low and white is common. Could there be damage to the pump?
@SpaGuy
@SpaGuy 2 жыл бұрын
Could yes.. That would be a dead short.. I have never done that so I don't know what happened..
@brettsigrist1797
@brettsigrist1797 4 жыл бұрын
do have any experience with BullFrog spas? I'm trying to figure out wiring a replacement circulation pump and the tub only has 3 wires. one is pink, one is black, and one is green. the pump I bought is not the exact same as what came out. however, it was sold to me as a direct replacement. The new pump wiring inputs are totally different than the oem.
@SpaGuy
@SpaGuy 4 жыл бұрын
The Pink wire is actually white and it is common or neutral.. Black is Hot or Load and green is ground.. If it is a circ pump it only has 2 spa hook ups and a ground..
@brettsigrist1797
@brettsigrist1797 4 жыл бұрын
@@SpaGuy Thanks so much for the response. The issue is that the pump has 4 inputs plus ground. its supposed to be able to be used as a 115v or 230 v but none of the wiring diagrams it came with show it with only 3 wires hooked up.
@SpaGuy
@SpaGuy 4 жыл бұрын
@@brettsigrist1797 If it has 4 wires it is not a circulation pump.. It is a jet pump those are two completely different things..
@brettsigrist1797
@brettsigrist1797 4 жыл бұрын
@@SpaGuy ok. Thanks for your help. I guess I'll be picking up another pump.
@cas951
@cas951 4 жыл бұрын
I just bought a new motor. The connections are numbered but the old one is marked C, H and L. How do I reference the old to the new?
@SpaGuy
@SpaGuy 4 жыл бұрын
Watch the video..
@shama144
@shama144 2 жыл бұрын
So I tried to replace my hot tub motor, but now neither the old or new one turn on. I hear the solenoid click and there are no error codes on the topside panel, but the motor does nothing. When I test with a multimeter, there is 240 going into the spa pack as expected, and at the motor, each of the three wires have 120v when tested with ground. Those values don't change at all no matter the setting the hot tub is set to. Any ideas?
@screamintwinkie9341
@screamintwinkie9341 2 жыл бұрын
I’m having the same problem! 😭😭😭
@kathrynschultz9500
@kathrynschultz9500 3 жыл бұрын
It is it possible to wire a two-speed capacitor Watkins pump into a two-speed Hayward pump
@SpaGuy
@SpaGuy 3 жыл бұрын
No..
@SuperBuskey
@SuperBuskey 3 жыл бұрын
Hi Spaguy My pump is a two speed but the power cord only has black and white. The old pump looks like it has a jumper to another terminal. Im confused at to what I should do. both pumps are Flo-master XP2 on a Thermospa. With all this crazy COVID nobody answers phones anymore
@SpaGuy
@SpaGuy 3 жыл бұрын
If it only has a black and white wire they are using the pump on high speed only..
@SuperBuskey
@SuperBuskey 3 жыл бұрын
@@SpaGuy Thanks, high speed it is!!! Thanks for getting back to me, super appreciative..
@chrisfoxwell4128
@chrisfoxwell4128 5 жыл бұрын
I have a Master Spa Concord 3 person from 2005. The motor is dying and according to Master Spa the replacement is $560 for a 3.6hp 2 speed motor. I can find plenty of other replacements but the original claims to be 400gpm and i can't find anything remotely close to that. Is 400gpm an actual thing or is that a misprint?
@SpaGuy
@SpaGuy 5 жыл бұрын
What brand pump Chris and what amperage?
@chrisfoxwell4128
@chrisfoxwell4128 5 жыл бұрын
@@SpaGuy ,the brand is Sta-Rite Dura-jet and the amperage is 8.9/3.0
@Atragichope1
@Atragichope1 5 жыл бұрын
I have a two speed motor as mentioned at 7:10. Can I use this motor to replace a one speed motor?
@SpaGuy
@SpaGuy 5 жыл бұрын
Yes just use high speed.
@Atragichope1
@Atragichope1 5 жыл бұрын
Spa Guy thanks for the quick response
@ScreamingLemon
@ScreamingLemon 4 жыл бұрын
I have a 2 speed pump with 3 wires..... I bought my hot tub in 2001. Recently only one speed works.(the circulation) I have a Balboa MAS 500 controller. I am not sure how you get two speeds out of a 115 v 1.3 amp motor, but it has for the last 20 years. I have had after many arguments with suppliers. Is there a step down transformer or a switch within the board that gives it the second speed?
@SpaGuy
@SpaGuy 4 жыл бұрын
There is no such thing as a 2 speed pump with 3 wires.. It is a one speed pump.. based on the amps it is a circulation pump and there is another 2 speed pump plugged into jet 1 position on the board..
@ScreamingLemon
@ScreamingLemon 4 жыл бұрын
​@@SpaGuy what I mean is I have a 1speed motor that has 3 wires and runs as a two speed in the hot tub. It is the circulation pump on Lo and when you hit the Jet button it runs on Hi. I see what looks like a step down transformer in the circuit box. I'm wondering if that is used as Lo and the standard speed as Hi.
@SpaGuy
@SpaGuy 4 жыл бұрын
@@ScreamingLemon That does not exist.. You said you have been fighting with other vendors about this you are wrong.. The 2 speed pump is another pump.. I have not seen every hot tub but we have 9000 that we service and not one of them has a 3 wire circ pump that works as a 2 speed.. It does not exist.. Go to the tub and trace the wire from the pump1 circuit and you will find the pump that used to be a 2 speed.. It is funny you want help but you want to tell people who are trying to help you they don't know what they are talking about..
@ScreamingLemon
@ScreamingLemon 4 жыл бұрын
@@SpaGuy Found It. Every time I replaced the circulation pump, the two speed worked. So I thought they were one of the same. Around the back of the hot tub I found the 2nd pump. Water had leaked on the connections. Spliced new connectors on the "4 pin amp" connections and works. Thanks for your patients with me...... sometimes I need a kick in the head. :/
@dwrdyts
@dwrdyts 6 жыл бұрын
I have a 230 V two speed pump that keeps blowing start capacitors… I’m about to my wits end I can’t figure it out! Is it possible that my pump is bad?
@SpaGuy
@SpaGuy 6 жыл бұрын
Yes If the wire size to the tub is good and everything else works normally you can just have a bad motor.. If the wire to the tub is too small it can cause the amperage to spike and blow the cap..
@dwrdyts
@dwrdyts 6 жыл бұрын
Spa Guy The pump is only around 1 year old I guess it could be defectiveI know all of the wiring to the tub is good
@dwrdyts
@dwrdyts 6 жыл бұрын
And thank you for the quick reply I really appreciate it!
@allrock1238
@allrock1238 5 жыл бұрын
Is the centrifugal start switch opening when the motor spins up to speed ? is the replacement start Capacitor rated for the operating voltage or higher ? just because the motor clicks when it spins up does always not allways mean the contacts for the centrifugal start switch are opening if they don't open the motor will kill start caps and . If the motor has a run cap check it as well .. thoughts on these suggestions ?
@robplatt6422
@robplatt6422 3 жыл бұрын
Question: my pump is on the old j&j system but the wiring diagram on my panel says black is high and red is low. So I'm wondering which is correct
@robplatt6422
@robplatt6422 3 жыл бұрын
Also the pump wiring diagram is the same as the Century lansar AO pump wiring diagram from your video
@SpaGuy
@SpaGuy 3 жыл бұрын
As mentioned in the video some are backwards..
@robb2465
@robb2465 Жыл бұрын
So my pump question....I connected my 230v Waterway 3721621-1D Executive 4HP 2SP pump replacing a gecko pump. The Exec shows H on top C in the middle and L at the bottom. Under normal operation, my pump will turn on circulation on its own. Since I wired the Exec up when circulation comes on the high speed jets come on. In theory I can swap the red and black wires and it should work properly correct? I'm just paranoid of frying the $300+ pump or my spa board. I just want to make sure because I saved by doing this myself but it just goes to show that sometimes you should hire the professionals!! I was an avionics technician for four years way back in the day so I understand at least the basics of electronic and electricity.
@SpaGuy
@SpaGuy Жыл бұрын
The low speed needs to come on first and be the circ and filter cycle.. It could eventually harm the board if you leave it on high and also overheat the tub during hot weather..
@robb2465
@robb2465 Жыл бұрын
@@SpaGuy Thank you!!! I also verified with a very nice local spa guy and it is fixed now. Thank you again!!!
@anomesade
@anomesade 3 жыл бұрын
do you have wiring diagram for Marlow sd7 0038a?
@SpaGuy
@SpaGuy 3 жыл бұрын
Never heard of it.. The diagram for your motor is on the motor..
@eckardjoele
@eckardjoele 11 ай бұрын
Will it work at all if you wire it up wrong?
@SpaGuy
@SpaGuy 11 ай бұрын
Might.. Depends on how ti is wired..
@davidstinsman9694
@davidstinsman9694 2 жыл бұрын
So if my pump is 230v with the 4 wires how do I wire it if my board only has room for 3 wires at 240v
@SpaGuy
@SpaGuy 2 жыл бұрын
If there is only 3 wires you have a one speed pump and only need 3..
@davidstinsman9694
@davidstinsman9694 2 жыл бұрын
@@SpaGuy the pump has 4 but the board doesn't have a spot for 4 just 3
@jessicagrace8387
@jessicagrace8387 6 жыл бұрын
I had a pump that was 120/230 , you have to move two wires inthe motors panel.
@SpaGuy
@SpaGuy 6 жыл бұрын
A dual voltage pump is very rare on real hot tubs so this video is not about rare motors it is about things most will see..
@jessicagrace8387
@jessicagrace8387 6 жыл бұрын
Agree but they are out there.
@SpaGuy
@SpaGuy 6 жыл бұрын
Yes there are all kinds of pump configurations out there but they are not worth mentioning since they are rare and create confusion.. I have 9,000 service customers and out of those there are maybe 5 tubs with a dual voltage pump.. So not worth mentioning.. Thanks
@paulelgin9522
@paulelgin9522 7 жыл бұрын
hayward super pump 110 two speed???
@SpaGuy
@SpaGuy 7 жыл бұрын
What is the question?
@nancynipper4304
@nancynipper4304 7 жыл бұрын
Spa Guy will the motor get hot?
@paulelgin9522
@paulelgin9522 7 жыл бұрын
I have a hydro quip cs800 and a super pump3/4 diagram on motor not clear on two speed ..
@SpaGuy
@SpaGuy 7 жыл бұрын
Most super pumps are not 2 speeds... It is possible that yours is because the CS8000 is a inground hot tub controller... It usually has a diagram in the back of the motor under the cover and many show what the speeds are at the connections.. Send me pictures of the wiring diagram and the back of the motor open... That is really a pool pump and not spa pump... parts@htpofa.com
@rayfristrom7097
@rayfristrom7097 5 жыл бұрын
What is your phone #
@Chrisanova
@Chrisanova 2 ай бұрын
I have a new challenge for you if you want to except it. Maybe it would make for a great video too
@SpaGuy
@SpaGuy 2 ай бұрын
Ok what is it?
@Chrisanova
@Chrisanova 2 ай бұрын
I had a guy come over to fix my parents hot tub. He determined that the control panel was bad (and it was sooo bad). It was late in the day when he left for ace to pick up some parts and decided that he would finish first thing next morning. Never heard from him again. I went ahead and installed the new heater myself but have no idea how to do the wiring. Without the control panel. The hot tub AND pump company have BOTH gone out of business so they are no help. is there a way to hook this thing up without a control panel? can send you pics of what i have as soon as i figure out how to do that lol
@SpaGuy
@SpaGuy 2 ай бұрын
@@Chrisanova email pics parts@thespaguyinc.com
@samanthatellier6688
@samanthatellier6688 Жыл бұрын
Parler vous francais
@SpaGuy
@SpaGuy Жыл бұрын
Je ne sais pas mais je peux traduire..
@christopheramoroso6801
@christopheramoroso6801 Ай бұрын
I've got a flooded basement I'm just using a Jacuzzi pump and I just want to wire it on high-speed directly just plug it in and pump anybody know how
@zzsql
@zzsql Жыл бұрын
Hi. My spa pump is 2 years old and is loud so I'm replacing it. (56WUA400-2/6) Wanted to ask if I can leave the wet end pump section in place while replacing the motor end so I don't have to drain the hot tub. Seems possible to me. Any advice?
@SpaGuy
@SpaGuy Жыл бұрын
Bad Plan the problem is the pump that damaged the motor.. I have the pumps and parts here: hottubpartsofamerica.com/search.php?search_query=wua400
How to Wire any Hot Tub in 5 Mins or less
7:44
SPA MAN
Рет қаралды 40 М.
How To: Wavemaster Jet Pump Repair (10 Simple Steps)
8:32
backyardplus
Рет қаралды 237 М.
小宇宙竟然尿裤子!#小丑#家庭#搞笑
00:26
家庭搞笑日记
Рет қаралды 28 МЛН
HOT TUB Pump Not Working? 6 Common Problems & Fixes | Swim University
6:04
5 Common HOT TUB PROBLEMS and Solutions | Swim University
5:26
Swim University
Рет қаралды 600 М.
Wiring a two speed spa pump and installation #49
3:37
softcellelectrical
Рет қаралды 111 М.
Balboa Legacy Systems Series - Proper GFCI Wiring
4:47
balboawatergroup
Рет қаралды 163 М.