I recently retired from the other large gen company (almost 25 years) and never saw a mouse in that series of set unless someone knocked out the rubber around the gas line (reseal with silicone) or left the front door off. Ants (and misc bugs) are another issue and they come for the heat in the control box. We used "ant bait traps" by the battery and I also found they don't like WD-40, which has the added benefit of keeping the aluminum nice and steel parts from rusting. I basically clean the unit, fog everything with WD-40, then wipe it down again. No rust, no crust, and way fewer bugs!
@johnbarton187810 ай бұрын
You forgot the most important part, checking the valve lash . The manual says every 2 yrs but I check and adjust yearly. Instant death to a air cooled engines are loose or misadjusted push rods.
@rickw4850 Жыл бұрын
I'm a master plumber by trade, you dont need the generator running to check for leaks. It will still leak without the unit running.
@jameskozlowski41395 ай бұрын
I thought the same.
@TinMan0555 Жыл бұрын
Just bought my first “standby” generator as a backup to a solar array. Thanks for the maintenance tips. 👍🏻
@jimpann Жыл бұрын
Great job guys! What about the valves?
@mathi9g398 Жыл бұрын
Great informative video! I'm a service technician for a dealer in Miami. I definitely need that oil drain extractor!
@jamiearellano890310 ай бұрын
To do a test before the oil change do I have to turn off the main breaker switches?
@LestonDr Жыл бұрын
1) Sand shovel under the oil filter is brilliant 2) 50/50 Borax and suger will take care of ant issues back to the nest 3) Agree with rupe53, Ant and mouse baits are a smart move. 4) Wires: To get around the poor design, Squirrels hate Cayenne pepper insect repellant. I apply twice a year especially the cars engine compartment. 5) Generac: I know two souls that have owned these generacs. Both had to change the circuit board a month past the 5-year extended warranty. And there is no way to mechanically work-around this board. Generac made sure you could not repair the board or components on the board. Rather than building like it like the time tested engine control board in your car. Generac had the whole control board cast in an acrylic like plastic, rendering another component useless and sent to the landfill.
@philliphall5198 Жыл бұрын
Yep they fk you just like China does
@sheepdog38284 ай бұрын
spray BiFen around base for ant, spiders and such. Use ear tags inside for spiders as well. Did not see plugs get replaced.
@robertmontgomery71583 ай бұрын
Is a valve clearance check part of maintenance?
@mtlhedz Жыл бұрын
You guys did an amazing installation job on this, inside and out.🎉🎉❤
@tonydavis49577 ай бұрын
Yall forgot to check valve lash needs to be between 3 and 4 thousands. Also LOCK the gen cover. My installer said several customers have had there cover blow up enough to get rain in it and damage controler when not locked. Put keys in breaker box on magnet inside so you don't lose them
@mikepatel63232 жыл бұрын
I know people who did not lock the top and hurricane came power went out and generator was destroyed while running with heavy wind and rain with the top torn off.
@Japplesnap Жыл бұрын
So he checked the oil sensors and the stepper motor with his hands, huh? No multimeter?
@litz132 жыл бұрын
You aren't wrong about those rodents. My parents own that exact model of Generac generator now because rodents had a Kohler dinner. Absolutely shredded the cable harness.
@abrahamyouwakim Жыл бұрын
why didn't you adjust the valves?
@pauld7309 Жыл бұрын
I have a 16 kw G force engine. Would you know when checking oil on the oil filler dip stick, is it checked with oil stick resting on thread's Or threaded all the way in?? Manual doesn't say, & have gotten a clear answer yet!! Thx.
@TheBlueveinthrobber Жыл бұрын
Whats your schedule for checking valve gap?....how many hours of run time...or is it based on when it wont start?
@scotts4125 Жыл бұрын
I have the newer style 22kw where you can't get to the battery from the front. You have to remove the side panel. What are the major differences in the units?
@billnelson3605 Жыл бұрын
I've also got the type you have, where you have to remove the side panel. I followed the instructions, but was unable to lift it straight up as the instructions say you should do. I'm looking through all these videos, looking for someone who's done it. With all the proper screws removed, I've been unable to removed the panel. Actually raised the generator and pad off the ground trying.
@scotts4125 Жыл бұрын
@@billnelson3605 There is a screw hole on the bottom does yours have the screw in it? Mine doesn't and the tech said they leave them out. I watched him do the service so I could pick up any tips.
@billnelson3605 Жыл бұрын
@@scotts4125 That will be my intention also. It appears you need a code to clear the alerts, too.
@sanitary103 Жыл бұрын
@@billnelson3605 hmm. I haven't done it for awhile but didn't have any problems. I'll take a look if you haven't solved the problem yet.