Рет қаралды 5,018
Here's the caps I used, please double check your board before you order.
Capacitor Replacement List:
All rated for 105C
C609--50V-1000uF (Problem Child) C606--50V-100uF
C608--50V-10uF (Problem Child) C912--50V-100uF
C913--100V-10uF C914--50V-100uF
C603--50V-220uF C620--50V-330uF
C711--50V-1uF C716--50V-1uF
C718--50V-47uF C761--250V-2.2uF
C730--50V-470uF C771--50V-1uF
C252--250V-2.2uF C251--100V-47uF
C723--50V-5.6uF(Large Body) C902--50V-47uF
C254--100V-1uF C951--50V-1uF
C301--50V-1uF
Today we'll be repairing an HP 54601A 4 channel, 100 MHz oscilloscope (or 54600A if you have the 2 channel model). This is a well known issue on many online forums, but as far as I know this is the first video of the screen repair out there.
I really think just replacing the two known troublemaking caps would make a good repair, but if possible I recommend recapping both boards. You'll also get to see a method of PCB trace repair that seems to work well.
Also if anyone can point me in the right direction for someone who might be interested in repairing the TDS 640 scope please let me know. I'd prefer someone who has a scope like this already the I can just send the acquisition board to.
All in all this is a really simple repair and if you can get a good deal on a broken scope it's well worth fixing.
As always, be safe, try this at your own risk, have fun, and thanks for watching! Oh and like, subscribe, and share! And you can now follow me on Instagram @bebsrepairbench. Go check it out!
Interested in some of the stuff I use in this video? Maybe you want some of that Flux Remover that worked great to clean up the scope? Follow these links or check out MG Chemicals website!
Flux Remover: www.amazon.com/MG-Chemicals-4...
Small Cleaning Brush: www.amazon.com/MG-Chemicals-8...
Hog Bristle Brush: www.amazon.com/MG-Chemicals-N...
Flux Pen: www.amazon.com/MG-Chemicals-R...
Solder: www.amazon.com/MG-Chemicals-L...