This video highlights inexpensive tools to install electrical wiring and boxes into ICF walls. Also instructional video on techniques to make this job quick and easy.
Пікірлер: 88
@decarteaux Жыл бұрын
That soldering iron trick with the #9 wire is brilliant!
@selahman10744 жыл бұрын
Best icf tutorial I've come across so far! Thank you!
@briant70675 ай бұрын
Thank you so much for sharing!
@lowerloupprepper6 жыл бұрын
Thanks for taking the time to make the video. Exactly the perfect how to I needed to start the electrical in my first ICF construction basement. Much appreciated!
@carlosbusto7382 Жыл бұрын
Great home made tools
@grassroots9304 Жыл бұрын
Thank you for the time and effort to make this video. This is helpful.
@4philipp2 жыл бұрын
Much cleaner presentation and performance then the instruction video on the build block site. Nicely done. 👍
@larrydugan14412 жыл бұрын
Thanks. Absolutely excellent. Made my install so much easier. High five.
@elizabethbatten85145 жыл бұрын
Thank you, fantastic ideas!!
@dallascumming87505 жыл бұрын
Well done. Very smart!
@bruce7mail1226 жыл бұрын
Impressive technique.Thanks
@N-Scale6 жыл бұрын
Very Very cool ideas and certainly works and saves time. Love the video. Mike
@paulwerff6 жыл бұрын
Thanks for your effort. Realy worthwhile ideas!
@tomsterism7 жыл бұрын
Excellent presentation. Have wondered about these particular installation processes for several years. Beautiful, man!
@richardbrooks35696 жыл бұрын
Nice demo. Thanks.
@scottpoore80804 жыл бұрын
Getting ready to finish my basement and was wondering the most efficient way to do this. Thank you!
@kartiktraj2 жыл бұрын
Super helpful! Thank you!
@mktwatcher5 жыл бұрын
Great ideas, Nice work!
@mrg33846 жыл бұрын
Pretty slick brother! Thanks
@mcanning516 жыл бұрын
Great training for rough-in electrical on ICF, thanks for sharing. Yankee Ingenuity at it's best.
@StoneyRidgeFarmer5 жыл бұрын
Great video brotha! Thanks so much....we're getting ready to start a home build project for our dream home...I have an electrician background and was curious about installation of wiring in ICF walls
@jimsmyth77776 жыл бұрын
Great video! You saved me a bunch of money and time. Thanks
@robnaumoski88536 жыл бұрын
Thanks I'm in Australia and will use your suggestions.
@handyharris14695 жыл бұрын
Great ideas, thanks. Im a electrican but haven't worked with ICF yet.
@johnf90766 жыл бұрын
Great ideas. I would suggest you strip your cables before you insert the box.
@DaddyBear30006 жыл бұрын
John F good point. Especially on thicker gauge cable, can be a paint to muscle about.
@walterlessing29636 жыл бұрын
Awesome video. I don't think I'll ever use ICF but I LIKE your ideas. God Bless!!!
@TheMarpalm5 жыл бұрын
Great video!
@andrewbarker94475 жыл бұрын
Thanks! really helpful
@soglaten6 жыл бұрын
some good ideas there thanks.
@johnwarstler42922 жыл бұрын
Great video, thanks for the tips.
@jaysonstewart5962 жыл бұрын
Nice! Great ingenuity.
@danielgeng23064 жыл бұрын
Pretty clever stuff !
@michaelstella5771 Жыл бұрын
Well done sir.
@johnandlou6 жыл бұрын
Excellent thank you.
@cath4v6 жыл бұрын
Thanks very much. 👍🏻🇨🇦
@TrumpFan-yn2rj7 жыл бұрын
I love what you did and shared in this video. Much thanks.
@TrumpFan-yn2rj7 жыл бұрын
How do you handle 40 cables for say electric oven, etc. Your horizontal cut is so straight. Do you make two evenly spaced horizontal cuts for larger cables? How do you fill the foam afterwards? Is it required to cover installed wires w/ foam or glue before inspections or not because sheetrock would cover it? To maintain R ratings It would make sense to fill in cut insulations?
@cecandam7 жыл бұрын
Glad to help!
@cecandam7 жыл бұрын
My electric oven require 3-10+ground (which is a large cable). I ran the chainsaw a second time right next to the first cut. I fill the cut in the ICF with canned spray foam (minimal expanding door and window version works well). I had Nudura spray foam left over from gluing the block together that I used for part of it. As long as the romex size matched the cut size snugly enough that the romex wasn't loose, the inspector passed it. If it could move easily, he wanted it secured into the cut with spray foam. I like the idea of securing it and , like you said filling the gap in the insulating envelope. As far as cutting a straight line, the key for me is having a visual guide. I usually cut directly on a seam in the ICF. If not, I make a line with a marker to follow.
@stephentaylor93664 жыл бұрын
Great Video!~!! I sent this to my electricians, and they loved it! (Didn’t cut their cost though (lol)
@Futurestone6 жыл бұрын
Great video
@tomtillman5 жыл бұрын
thanks! great tips. last job, I bought about 10 rolls of 250 ft. of wire. I coulda got a spool.
@NDcompetitiveshooter9 ай бұрын
Thanks for the video. If you get a chance, please let me know where can you get those specific electrical boxes at? Thanks!
@jubenning5 жыл бұрын
Love the converted soldering gun, just ordered one and will replicate your idea. Thx!
@bucmeister77133 жыл бұрын
He mentioned a #9 wire and lost me. Copper, steel, nichrome? I've heard of gauge numbered wire, but it is most always even numbers above #1.
@jubenning3 жыл бұрын
@@bucmeister7713 I used #10 copper and it was OK. Probably would have been better to use #8 copper, does not bend as easily as the gun hit a piece of concrete in the back of the wall. Also depends on what size your gun will accommodate.
@nickg37945 жыл бұрын
Sweet!
@ScottishNSRailFan6 жыл бұрын
ICF is a great product
@portaadonai6 жыл бұрын
Never seen a IFC wall before slick ideas though
@harleco16 жыл бұрын
I like it alot
@rubixholdingswithrubiconho40333 жыл бұрын
thank you for the video. Really appreciate it . Question, what do you use to protect the Romex once the drywall is installed, studs use nail plates what is proposed for ICF?
@charlesarmstrong35362 жыл бұрын
Good question.
@MrCharliechayna6 жыл бұрын
Just a question, when the sheet rock goes on , do they use screws to secure the sheets to the ICF? And if so what happens when they screw into the cabel. The cable needs mechanical protection. what has been your experiences?
@kareemt45266 жыл бұрын
Electrical forces as long as the wire is an inch and a half deep the screws won't hit it
@randyjohnson34124 жыл бұрын
is it safe to have the wires exposed to the foam?
@RJM10114 жыл бұрын
Some good ideas thank you for the video I am hoping to use ICF blocks but I am looking for another State to build in after being told I can not have a basement under the home in TN and the builder does not like ICF blocks.
@bucmeister77133 жыл бұрын
No basements, WOW, that's a new one for sure.
@RJM10113 жыл бұрын
@@bucmeister7713 Yes well I still hope to build with ICF and put my log home on top of them. Thank you.
@charlesarmstrong35362 жыл бұрын
@@RJM1011 I can see that if buying in a builder's subdivision. Kinda like other customers will see and want it also. Not smart in my opinion, could be a money maker for the builder. Did you find a place to build?
@RJM10112 жыл бұрын
@@charlesarmstrong3536 Yes thank you I have found a place to build but thanks to being messed about by the US Gov I will now be building in The Bahamas. Thank you
@cdnbacon20016 жыл бұрын
is "lumex/ romex" jacket OK for spray foam. I've heard that it can make the jacket brittle over time. also inspectors want to see a loop before going into the JB, ( here in Canada) have you had that come up? BTW great video
@dondonaldson16846 жыл бұрын
cdnbacon2001 turn the soldering gun wire vertically and whittle an opening for the loop, leave an inch before the box, one the flange side you have to move the whittled area a bit away from the box....inspectors want to see the loop within 6 inches of the box. This also helps in case more wire is need in the box.
@davidwooden41756 жыл бұрын
Here in the USA, I had an inspector have us remove the romex because we were installing the wires in a concrete styrofoam block. Had to replace the wire with an underground rated wire. Inspector said it was due to the lime in the block and nothing about the foam. No issues with foam on regular romex.
@charlesarmstrong35362 жыл бұрын
Spray foam insulation passes inspection everywhere. If you choose to you can use commercial grade wire that comes in flexible metal conduit.
@ddredd995 жыл бұрын
where did you get your electrical boxes from?
@davidwatson81425 жыл бұрын
Menards
@DavidCavanFraser7 жыл бұрын
Dude THANK YOU, just saved me hundreds of dollars, and gave me an excuse to buy another chainsaw!
@mistyman4116 жыл бұрын
love that sodering gun idea! ive done electric in this stuff .used router.what a mess it made.and there should be loops at the box incase drywallers cut a wire.what a nightmare to repair in the box
@nakedgijoestudios59016 жыл бұрын
Como learn facts first before posting "If the heat gets high enough to ignite the foam the entire room will be ablaze in a matter of seconds" Will the foam add fuel to the fire? The foams in ICFs are manufactured with flame-retardant additives. These prevent the foams from burning by themselves. If you hold a match to the material, it will melt away. www.forms.org/index.cfm/fireresistance
@mariovazquez38744 жыл бұрын
Thanks for sharing. Easy and cost effective approach, but I have a question. Is is not a safety hazard to do it that way? For what I understand house wires can get hot under load. In the Caribbean the concrete houses (not ICF) tubing is inserted in walls prior to pour the concrete, and electrical goes in there.
@charlesarmstrong35362 жыл бұрын
Yes and no is what I found in my research. Some will use absolute minimum on wire, which can be overloaded by a home owner. This can cause the wire to get hot. A good electrician ,in this situation, will put more circuits in or upsize the wire so it is at 75 percent or less operating rating under normal use. Wire should always be in conduit when in concrete. It is a good idea to install conduit for water lines also when in concrete.
@Drwild755 жыл бұрын
Did anyone go to sleep watching a little hole cut in styrofoam?
@russb29456 жыл бұрын
Refreshing to see guys that are creative and know what they are doing and not doing a Jessy with every project....
@_P0tat07_6 жыл бұрын
Hah, that's cool. I'm by no means a safety Nazi, but please, make some sort of guard for that chainsaw. And the soldering iron is cool, but it seems a tad bit slow. But still. Great ideas
@benningtoncamper28526 жыл бұрын
Interesting ideas. However there are a couple of code violations in doing it this way. 300.4 requires protection against physical damage - the intent being to prevent nails or screws from being driven into the cable when it is hidden. 334.30 requires that cable be secured within 12" of every outlet box - the intent is to prevent anything from pulling on other connections.
@kolbyskoien40546 жыл бұрын
Would foam work as a fastener? And you could still use nailing plates to protect studs, could you not?
@davidwooden41756 жыл бұрын
Kolby, depends on your electrical inspector and how relaxed he/she is with the codes. I have worked on projects that were different forms of ICF. My inspectors wanted to see if the cut channels were deep enough to meet code, then we had to secure the wire with 2" long staples since normal wire staples did not hold in the ICF, then low expanding foam was used to fill the gaps. The chain saw with a wheel for a depth gauge is a great idea.
@tecnolover26426 жыл бұрын
Code is going to be different from location to location. His video wasn't about addressing all the codes. You can do that yourself in different ways using conduit, anchor plates etc.
@SnowStarBlack5 жыл бұрын
yes. it would. as it secures it from movement.
@Searey075 жыл бұрын
If my inspector said it wasn't secured, I'd challenge him to pull it lengthwise through the foam...good luck with that! As for protected, a hanging wire between studs is no better protected. If the inspector insists, put 1" metal strapping into the grove to deflect any nails.
@Drwild755 жыл бұрын
A router works faster and cheaper.
@MyFortressConstruction5 жыл бұрын
What kind of router bit do you use? I put in a 1/4" drill bit and that can cut deep enough, but it can't cut through the plastic "studs". The chainsaw is perfect for this and the solder/hot knife is a great idea too.
@noname-oz2kk5 жыл бұрын
Looks like an environmental disaster to me...Shocking this ICF system can't be ordered based on plans so the system installs ready for wiring and plumbing and you don't have synthetic debris polluting the site...I'll pass.
@MyFortressConstruction5 жыл бұрын
You sweep and vacuum after. Disaster averted.
@specialestness3 жыл бұрын
Hope you don’t catch the cement truck cleaning his truck out at the end of the driveway before he leaves