Derek in part 2 of the item g 11 unsafe situations quiz gives us more unsafe situations that engineers and trainees can classify as ID, AR OR NCS along with do we need to riddor. • ID, AR, NCS THE IGEM :... Link to part 1
Пікірлер: 70
@tomkatgastraining3 жыл бұрын
kzfaq.info/get/bejne/iceKiLxly86VYIE.html Link for part 1 if you haven’t seen it 👍🏻
@prsheating2 жыл бұрын
Excellent very helpful mate...been a Gas engineer for over 35 years...your ironing out these grey areas.
@azimkhan98623 жыл бұрын
Fantastic video Derek, highly appreciated the best videos out there for unsafe situations are your videos part 1 and 2. Hopefully part 3 soon 😋
@ryandow39543 жыл бұрын
Really enjoying these videos 👍 keep them coming!
@patrickoregan7102 Жыл бұрын
Great videos,thanks Derek , a big help with up and coming ACS 👍
@williamhoughton14842 жыл бұрын
Well done Derek , Keep them coming . It brings me up to speed!🤪
@Tony-sr7vq Жыл бұрын
Hi Derek just like to say a big thank you for all your time that you do it is a big help. Thank you
@aphroditenajad26032 жыл бұрын
Fantastic, Thank you, I love this questions and answer with explanations! Well done !
@hazelbulgin6383 жыл бұрын
Brilliant keep them coming 👏👍🏾
@leaturk113 жыл бұрын
Great stuff, keep them coming.
@mohammednadeem72743 жыл бұрын
Excellent video Derek on these unsafe situations. Its good to know what you will come across on jobs onsite. Thanks.👌👍👍😁😀
@kelvinjones19953 жыл бұрын
👍 Always something to learn from the Guru 😎
@hussaingonoo9593 жыл бұрын
Another fantastic Video
@vahidkaregar80493 жыл бұрын
Brilliant, really informative , please keep them coming🙏
@monikanader94542 жыл бұрын
Great video, very informative. Thank you👍👍👍
@msuk5957 Жыл бұрын
Thank you Derek , Mohamed Hassan
@timeintheuk8 ай бұрын
Helpfull ta
@martynlewis59013 жыл бұрын
Excellent, thanks. ACS due next year so this is all good prep. 👍🏻
@aghasahib47033 жыл бұрын
Brilliant video. Thanks alot mate
@saltnvinni12 жыл бұрын
Fantastic video
@jpfrench14963 жыл бұрын
Another great vid
@hamzaparvais39482 жыл бұрын
Brilliant thank really good mate
@chrisjones4500 Жыл бұрын
👍👍
@abchannel37373 жыл бұрын
Your are the best 🌹👍👌✌️
@thomasblades40592 жыл бұрын
Top video
@wallmackari3885 Жыл бұрын
the requirement of the equpotential bonding is clearly on the out let pipe from the meter , so I think it should be there to protect what ever inside the property regardless the inlet pipe or before the meter installation . if not there I think it should classify as AR and Not RIDDOR
@AnEyeScream2 жыл бұрын
Thank you, Nikola Ditsov
@lewisclarke4765 Жыл бұрын
👍🏻
@Neutron662 жыл бұрын
Ever since PME (protective multiple earthing or TNC-S) was utilised in the 80's, the risk of elevated voltages on different exposed conductive parts has increased. It is for this reason equipotential bonding is necessary. Neutral and Earth a marshalled together at the meter position (as well as the substation) and therefore the installation earth potential (that being the same as the neutral ) can be a number of volts different to true earth potential.
@suewarrington81552 жыл бұрын
👍Sue Warrington
@paigedarby4997 Жыл бұрын
Hi Derek Great videos. Would you be able to do more videos on Unsafe Situations and how to best classify them. Are there any techniques to better identify them or is it just literally a case of keep practicing and revising? I did well in this video but struggled on part 1. Any help would be great on how to best revise. Thanks for all your other video as they've helped loads.
@andyjones78363 жыл бұрын
👍
@jerzyszczachor724 Жыл бұрын
Interesting about bonding 18th edition amendment 2 dose not required bonding on incoming services to the building if they are plastic. However if no bonding on water mains any current leakage under ground could travel through water also so if no bonding current could be present on boiler body before travel through earthing from a spur but if you disconnected power supply and bonding the appliance body becomes live. Also there is a major issue where problem was found the nutreal on electricity supply become faulty the current found way through earthing path. So there was gas explosions cause by that and they found fault where on gas pipe 35A has been recorded .
@SuperWayneyb3 жыл бұрын
🤘🤓🤘
@mdillon19763 жыл бұрын
8 00 phone gas board 🤣🤣got one wrong derek cheers 👍
@viran81212 жыл бұрын
👍🏽
@M20DAN2 жыл бұрын
tomkat👍
@localtradesuk8572 Жыл бұрын
Hi Derek great videos, Can you make more videos like this as it does help. I got a questions does fly screen on a vent does that reduce air so you need a bigger vent or no? thanks
@tomkatgastraining Жыл бұрын
No you can’t use a vent with a fly screen because it can get blocked by insects and spiders webs.
@marcinmasalski41832 жыл бұрын
Marcin Masalski 👍
@rayc15033 жыл бұрын
Strange IET electrical regulations state that if there aren't any extraneous conductive parts on the incoming mains and the incoming underground pipe is of non conductive material then no equpotential bonding is required. However according to BS 7671 regulations differ stating PEB must be fitted within 600 mm and before the first T branch in pipework. I can't understand why regulations differ through both industries. I'm completely for the installation of PEB however other electricians would argue that IET regs differ 🤷♂️. If on the Ecv there's a red ring present this indicates no PEB required. If there's no red ring downstream of the ECV then install a PEB clamp. It should be just below the ECV in any case.
@mj0n4id363 жыл бұрын
Brilliant video. I did better in this one than I did in part 1 😎. At 14:15 when talking about the flueless space heater and how it should be at least 1 metre away from a vent, how about a door? I saw this type of flueless space heater installed in a hallway not to far away from the main door to the house. What are the requirements for that? Thanks Derek. Much appreciated 👍🏻 Asian Jon. Training.
@tomkatgastraining3 жыл бұрын
The door is not that much of a problem because it’s closed most of the time and it’s a big area. The ventilation being too close is a problem because it could stop the ASD shutting down and make the room vitiated.
@leaturk113 жыл бұрын
The meter had a open uncapped pipe, so I marked it as ID
@tomkatgastraining3 жыл бұрын
The question was about the meter being inside the property not the open end 😜
@craighurst35993 жыл бұрын
CH👍
@bryanwilliams38272 жыл бұрын
Bryan Williams
@mustafaakbari62312 жыл бұрын
Mustafa akbari
@jon-paulward45802 жыл бұрын
Jon-Paul Ward
@stevehouse39042 жыл бұрын
GSIUR REG 7(1), PIPEWORK SUITABLE FOR GAS BEING USED IN AN INAPPROPRIATE LOCATION, would that include being less the 25mm from light switch?
@stephenhumphreys40992 жыл бұрын
Stephen Humphreys
@richardhodgson74433 жыл бұрын
Great video again Derek, brilliant for revision. Would you mind being the first person to actually demonstrate / show the procedure of unsafe situations practically. Ie actually disconnecting appliance, capping off meter, etc. Thanks 🙏
@lazylady812 жыл бұрын
so paint on a flue or boiler is AR?
@danielriglin9333 Жыл бұрын
Dan Riglin
@steve250276 Жыл бұрын
steve ward
@danielcarragher66283 жыл бұрын
Daniel carragher
@secondchance44983 жыл бұрын
ChrisTaylor
@stevehouse39042 жыл бұрын
I meant socket!
@carlhutchinson34583 жыл бұрын
Medium pressure gas meter has an open end on outlet 🤔 is that no ID? 🤔
@tomkatgastraining3 жыл бұрын
The scenario was the medium pressure meter was installed inside not the open end that’s why I gave scenarios not just said what’s wrong but yes an open end is ID
@BrothersGrim20123 жыл бұрын
No Bonding
@tomkatgastraining3 жыл бұрын
Is that nor ID and riddor then
@BrothersGrim20123 жыл бұрын
@@tomkatgastraining no Earth bonding i would make a note on the cert, advise the customer to get a qualified electrician to get it done for them
@tomkatgastraining3 жыл бұрын
@@BrothersGrim2012 don’t you mean leave a bonding notice at the gas meter to advise the responsible person earth bonding could be required
@BrothersGrim20123 жыл бұрын
@@tomkatgastraining I’m only learning so far so just had a go without looking in book, if I’d of referred to book then I would of have a fuller answer
@tomkatgastraining3 жыл бұрын
@@BrothersGrim2012 a lot more training required joe but keep it up 👍🏻
@mattrowntree33599 ай бұрын
15 Min into vid the gas meter has open end and you've classed it as ar and not Id 😮... the medium pressure one ..
@tomkatgastraining9 ай бұрын
The question was about medium pressure inside a property not about an open end on a gas pipe. I said at the beginning of this section it represents not this is what you find so a medium pressure meter inside a property is AR. For your information there is a disk in the meter outlet also so still no open end.