No video

inoRAC2 Overview - Racking of 15kv PowlVac Circuit Breaker

  Рет қаралды 93,120

inoLECT

inoLECT

Күн бұрын

inoLECT's universal Remote racking device, the inoRAC2, allows users to operate curcuit breakers from over 80 feet away from the dangers of electrical arc flash. The unit monitors torque and breaker position during the entire process, and displays data on a high-resolution color touchscreen. No switchgear modifications are needed.

Пікірлер: 22
@HighVoltageMadness
@HighVoltageMadness 3 жыл бұрын
This device looks really expensive but if it saves your life its definitelyy worth it
@michaelknight6387
@michaelknight6387 2 жыл бұрын
We had powervac equipment where I worked 12.5 kv primary switchgear. We just had a small motorized socket that mounted on the door and engaged the racking screw. It had about a hundred feet of cable running to a hand control with buttons for forward and reverse. This way we could stand on the outside of the room while doing this procedure.
@thet12king47
@thet12king47 7 жыл бұрын
I was hoping for the sound of 50hz running through a transformer starting up One of my favourite sounds
@510purple
@510purple 2 жыл бұрын
you from the uk?
@naifhaz3034
@naifhaz3034 7 ай бұрын
That is really useful full I hope the companies provide it it’s will makes high grantee of safety for person and switching device in case of any short circuit or such as cases
@fluke196c
@fluke196c 4 жыл бұрын
The user interface for this tool as shown is horrible, but I'm glad to see remote racking solutions on the market.
@ianmangham4570
@ianmangham4570 3 жыл бұрын
Bollocks
@user-fx9jd7eq5h
@user-fx9jd7eq5h 3 жыл бұрын
Высший класс подстанция .. Мастер инженер профессиональный все правильно сделал только по инструкции должно быть двое контролёров один снимает показания а второй страхует на расстоянии . но все равно шкаф отключать нужно и заземлять и на резиновый коврик вставать убедится что все отключил напряжения потом снимать показания
@7akm123
@7akm123 5 жыл бұрын
I usually rack in/out MV breakers by my hand and panel is open 🤚 Now I see the video. know My job not safe company doesn’t care about us
@inoLECT
@inoLECT 5 жыл бұрын
Sorry to hear that. Most companies aren't aware of the dangerous situations their employees face every day. Please forward our videos,website link to your supervisor. Maybe they just aren't aware that solutions like remote racking are out there. We're happy to call or demonstrate if they are willing to listen. Best of luck and safe racking to you.
@grahamman80
@grahamman80 Жыл бұрын
Looks like some Powell gear.
@1995jug
@1995jug 6 жыл бұрын
Wish we had one of those at work all hand crank.
@ShooterMcNut
@ShooterMcNut 5 жыл бұрын
Some audio would've been nice
@ciceroalcantara5793
@ciceroalcantara5793 2 жыл бұрын
Is this correct put our knees on the floor during the procedure?
@johnathanbell8404
@johnathanbell8404 2 жыл бұрын
I would buy it if it could also lift breaker out
@iareid8255
@iareid8255 3 жыл бұрын
That seems to be an expensive, slow and really uneccesary procedure. If a breaker is on the bars and closed the interlocks will not allow it to be racked down. It needs to be open to enable the racking mechanism.
@vasaricorridor7989
@vasaricorridor7989 3 жыл бұрын
U never ever use camera FLASH equipment in a active switchgear room
@MrKrisleatherman
@MrKrisleatherman 3 жыл бұрын
I have not heard about no camera flash before, and not that I doubt you but where is this information found?
@RH-ng9qm
@RH-ng9qm 2 жыл бұрын
@@MrKrisleatherman Good question. My answer is: on a placard posted on the ESS door, fence, or gear itself stating that the gear is equipped with arc flash sensing devices.
@FryChicken
@FryChicken 4 ай бұрын
The problem with these safety devices is they've gone a bit overboard and in turn are pain in the ass to use so nobody wants to use them.
@dicktits1884
@dicktits1884 5 ай бұрын
Ive yet to watch a video where a rubber mat is laid down on the ground where they kneel
INR3 Overview: Racking the GE Magneblast
13:42
inoLECT
Рет қаралды 77 М.
HOW TO RACK OUT VACUUM CIRCUIT BREAKER | ETO TROUBLESHOOTING
11:05
Joker can't swim!#joker #shorts
00:46
Untitled Joker
Рет қаралды 40 МЛН
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 209 МЛН
Cute kitty gadgets 💛
00:24
TheSoul Music Family
Рет қаралды 11 МЛН
Underwater Challenge 😱
00:37
Topper Guild
Рет қаралды 23 МЛН
Power Xpert UX 3D Demo Animation
4:59
Eaton
Рет қаралды 261 М.
Switching 11kV VCB Tamco
7:34
competence 33kv
Рет қаралды 2,5 МЛН
Siemens NX AIR VCB Insertion, Racking in & Closure
3:40
Power ai
Рет қаралды 8 М.
CURRENT TRANSFORMER, HOW TO RACK OUT AIR CIRCUIT BREAKER
8:22
Main electrical panel explained - Load center - service panel
10:19
The Engineering Mindset
Рет қаралды 1,2 МЛН
ACB Rack in Rack out Procedure.
6:36
The Rich Engineer
Рет қаралды 15 М.
Antipumping in Circuit Breaker | Why it is needed? Explained | TheElectricalGuy
19:04
Gaurav J - TheElectricalGuy
Рет қаралды 19 М.
inoRAC3 and the NEW ITE HK Accessory
8:07
inoLECT
Рет қаралды 624
Siemens GIS NXPlusC circuit-breaker panel
3:15
Siemens Knowledge Hub
Рет қаралды 452 М.
Joker can't swim!#joker #shorts
00:46
Untitled Joker
Рет қаралды 40 МЛН